1000 resultados para Análises de rede


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper provides a review on the latest advances and applications of the luminescence spectroscopy for the development of pharmaceuticals analyses methods, basically based on the photo- and chemiluminescence. The different forms of the drugs determination on pharmaceuticals through the fluorescence and chemiluminescence are discussed. The analyses include the drugs native fluorescence (liquid and solid-phases); the fluorescence from the oxidizing or reducing forms of the drug; the fluorescence from the chemical derivatization and their photochemistry and hydrolysis reactions. The quenching of luminescence and chemiluminescence generation for the pharmaceutical quantification are also shown. Finally, the trends and future perspectives of the luminescence spectroscopy in the field of the pharmaceutical research are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chromatographic methods are commonly used for analysis of small molecules in different biological matrices. An important step to be considered upon a bioanalytical method's development is the capacity to yield reliable and reproducible results. This review discusses validation procedures adopted by different governmental agencies, such as Food and Drug Administration (USA), European Union (EU) and Agência Nacional de Vigilância Sanitária (BR) for quantification of small molecules by bioanalytical chromatographic methods. The main parameters addressed in this review are: selectivity, linearity, precision, accuracy, quantification and detection limits, recovery, dilution integrity, stability and robustness. Also, the acceptance criterions are clearly specified.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

KSr2Nb5O15 is a ferroelectric material. The sintering process of the KSr2Nb5O15 ceramic doped with different amounts of CuO was investigated in this research. It was found that CuO is effective as promoter of the densification process of the KSN ceramic. The developed microstructures were different due to the amount of CuO and secondary phases were observed in the microstructures. However, the results of X - ray diffraction showed that only the tetragonal tungsten bronze (TTB) structure was identified in all the investigated ceramic systems. The thermal behavior of CuO and also of the CuO - KSN phase mixture was investigated by thermal analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work describes a low-cost electrochemical "wall-jet" detector for flow analysis. The electrolytic solution enters into the cell through a tube of stainless steel (200 to 300 µm i.d), reaching to the center of the working electrode perpendicularly and then being mixed to the remaining solution in the cell, which flows under atmospheric pressure into a waste reservoir. The proposed electrochemical detector can be used with any type of working electrode, from commercial to home-made, such as glassy carbon and metallic electrodes (modified or unmodified), which enlarge the applications of the electrochemical detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A computational method to simulate the changes in the electronic structure of Ga1-xMn xN was performed in order to improve the understanding of the indirect contribution of Mn atoms. This periodic quantum-mechanical method is based on density functional theory at B3LYP level. The electronic structures are compared with experimental data of the absorption edge of the GaMnN. It was observed that the indirect influence of Mn through the structural parameters can account for the main part of the band gap variation for materials in the diluted regime (x<0.08), and is still significant for higher compositions (x~0.18).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents the optimization of the microwave-assisted hydrothermal synthesis of [Zn(BDC)(H2O)2]n . The reactions were carried out at the fixed temperature of 120 ºC for 10, 20, 30 and 40 min. Pure crystalline [Zn(BDC)(H2O)2]n was obtained in high yield (ca. 90%) with a reaction time of 10 min. The phase obtained and its purity was confirmed by Rietveld refinement, with a final value for Rwp/Rexp equal to 1.48. Increased reaction times (20, 30 and 40 min) favored the formation of unwanted by products, resulting in mixtures of several crystalline phases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow system based on the sandwich technique is proposed for the sequential determination of ascorbic acid, dipyrone, acetylcysteine, captopril and paracetamol. The procedure is based on the reduction of Cu(II) by the analytes followed by the spectrophotometric measurement of the complex of Cu(I) with 2,2'-biquinoline 4,4'-dicarboxylic acid. Linear responses were achieved in the µmol L-1 range, with coefficients of variation better than 1.7%. Sampling rate was estimated as 60 determinations per hour, consuming 230 µg of BQA and generating 2.5 mL of waste per determination. Results for commercial samples agreed with those obtained by procedures recommended by the American and European pharmacopeias at the 95% confidence level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a multivariate statistical analysis as a valuable tool for educational management applied to public high school chemistry teacher formation. From 2003 to 2007, a decrease of 10% in the number of public high schools was seen, as well as a reduction of 7% in the number of teachers. Contrarily, there was an increase in the number of university graduate teachers. Principal Component Analyses reveal that in 2003, most chemistry teachers were not university graduates. In 2007, eight Regional Offices of Education reported teachers holding academic degrees, qualifying them as chemistry teacher in the school system

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the context of quality and good laboratory practices, the article recovers some historical data. From a specific Institutional situation (CPQBA/UNICAMP), is presented an experience of establishing and implementing a standard (NIT-DICLA-035) for good laboratory practice according to definitions of the Brazilian authority (INMETRO) responsible for regulating, monitoring, supervising and recognition in this area. The issue aims to focus on studies of pesticide residues in GLP parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to evaluate the effects of environmental factors on the content of secondary metabolites, the chemical profiles of infusions from leaves of seven genotypes of Lippia gracilis Schauer, sourced from two locations (Sergipe and Bahia state) and collected during different seasons: summer (with and without irrigation) and winter, were determined by HPLC-DAD. The fingerprint chromatograms were analyzed by PCA to evaluate similarities and differences among the samples. Results revealed differences among genotypes collected and cultivated under the same conditions, suggesting that three genotypes have greater resistance to drought conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study validated a simple and applied method for determining mycotoxins aflatoxin B1, aflatoxin B2, ochratoxin A, zearalenone and deoxynivalenol, in water from the rice production chain. Five solvent combinations for extraction were tested, with quantification performed by TLC/HPTLC and confirmation by LC-MS/MS. Mycotoxins in water from field and rice industries were evaluated. Mycotoxin recovery levels were around 90%. Two samples from rice parboiling waste were contaminated (deoxynivalenol/aflatoxin B1, 110/9 ng mL-1; and deoxynivalenol, 100 ng mL-1). Zearalenone, deoxynivalenol and ochratoxin A (36, 30 and 28%) were carried to soaking water during parboiling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multi-commuted flow system was developed to determine propylthiouracil (PTU) based on the reaction of its thiol form with iminoquinone radical generated by the oxidation of N,N-dimethyl-p-phenylenediamine in an alkaline medium. PTU can be found in tautomeric forms and the tautomeric equilibrium was displaced to enhance the thiol form. However, the reaction product is unstable and its residence time in the flow path was carefully investigated. The proposed procedure showed good precision (< 1.5%) and a limit of detection (3s) of 0.11 mg L-1. High recoveries were obtained in the validation test. The procedure was employed for propylthiouracil determination in medications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The need for effective and reliable quality control in products from pharmaceutical industries renders the analyses of their active ingredients and constituents of great importance. This study presents the theoretical basis of ¹H NMR for quantitative analyses and an example of the method validation according to Resolution RE Nº 899 by the Brazilian National Health Surveillance Agency (ANVISA), in which the compound paracetamol was the active ingredient. All evaluated parameters (selectivity, linearity, accuracy, repeatability and robustness) showed satisfactory results. It was concluded that a single NMR measurement provides structural and quantitative information of active components and excipients in the sample.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two methods using headspace solid-phase microextraction and gas chromatography - mass spectrometry were developed for the determination of polycyclic aromatic hydrocarbons (PAH) and BTEX. Best results were obtained using DVB/CAR/PDMS fiber, with 10 min extraction at 25 °C and 0.15 min desorption at 260 °C (BTEX), and PDMS/DVB fiber, with 60 min extraction at 90 °C, 10% NaCl and 5 min desorption at 270 °C (PAH). LOD intervals were 3x10-2 - 5x10-2 µg L-1 (BTEX) and 1.6x10-3 - 1.4 µg L-1 (PAH). The methods were applied to forty-five groundwater samples from monitoring wells of gas stations and only benzene level exceeded the limit established by Brazilian regulations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes the use of the open source hardware platform, denominated "Arduino", for controlling solenoid valves for solutions handling in flow analysis systems. System assessment was carried out by spectrophotometric determination of iron (II) in natural water. The sampling rate was estimated as 45 determinations per hour and the coefficient of variation was lower than 3%. Per determination, 208 µg of 1-10-phenanthroline and ascorbic acid were consumed, generating 1.3 mL of waste. "Arduino" proved a reliable microcontroller with low cost and simple interfacing, allowing USB communication for solenoid device switching in flow systems.