840 resultados para 4D Dosimetry


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The thermoluminescence (TL) response of Dy and Li doped 20CaB(4)O(7)-80CaB(2)O(4) (Wt%) glass-ceramic irradiated with ultraviolet (UV) radiation was studied. In order to act as TL activator ions, the Dy and Li ions were included in the matrix during the melting process to increase its TL efficiency. A single crystalline CaB2O4 phase was present in the glass-ceramic as determined by X-ray diffraction (XRD). The glass-ceramic 20CaB(4)O(7)-80CaB(2)O(4):Dy,Li wt% (named 20CBO7:Dy,Li) is a newly prepared TL material. Its thermoluminescent dosimetric characteristics have shown a linear response under UV radiation exposure and a good TL signal reproducibility, thus proving to be a promising material for using as an ultraviolet radiation dosimeter. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliação de condições dos equipamentos e dosimetria em setores de tomografia computadorizada utilizando protocolos de cabeça, abdome e coluna lombar em pacientes adultos (em três equipamentos distintos) e pediátricos com até um ano e meio de vida (em um dos equipamentos avaliados). MATERIAIS E MÉTODOS: Foram estimados o índice de dose em tomografia computadorizada e a dose média em cortes múltiplos, em exames com pacientes adultos, em três distintos equipamentos. Ainda foram estimadas as doses na superfície de entrada e as doses absorvidas em exame de cabeça para pacientes adultos e pediátricos em um dos equipamentos avaliados. RESULTADOS: Foram realizados testes de controle de qualidade, mecânicos, demonstrando que os equipamentos satisfazem as especificações de uso estabelecidas pelas normas vigentes. Os resultados da dosimetria mostraram que valores de dose média em cortes múltiplos excederam em até 109,0% os valores de níveis de referência, apresentando consideráveis variações entre os equipamentos avaliados neste estudo. As doses absorvidas obtidas com protocolos pediátricos são inferiores aos de pacientes adultos, apresentando redução de até 51,0% na tireoide. CONCLUSÃO: Neste estudo foram avaliadas as condições de operação de três equipamentos tomográficos, estabelecendo quais parâmetros devem ser trabalhados para a implantação de um programa de controle de qualidade nas instituições onde esta pesquisa foi desenvolvida.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CONTEXTUALIZAÇÃO: O Ultrassom (US) é um dos recursos físicos amplamente utilizado e pesquisado nos tratamentos de fisioterapia. Sabe-se que diante de uma escassa literatura sobre efeitos do US em tecidos sadios, muitos profissionais fisioterapeutas acabam realizando aplicações infundadas de métodos e parâmetros. OBJETIVO: Avaliar possíveis alterações histológicas e morfométricas do tecido sadio in vivo de ratos Wistar irradiados com diferentes intensidades de US. MÉTODOS: Trinta ratos da linhagem Wistar, distribuídos aleatoriamente em cinco grupos de seis animais cada foram tratados na região dorsal do lado direito numa área de 4cm². O lado esquerdo serviu como controle. O tratamento foi feito durante quatro dias com 2 minutos de irradiação. Verificou-se a intensidade de saída com dosímetro de precisão antes das aplicações. Analisou-se a histologia e a morfometria por meio do software Image Tool. RESULTADOS: Observou-se um discreto infiltrado inflamatório e adelgaçamento das fibras da derme, principalmente dos grupos irradiados com 1.5 e 2W/cm². Notou-se também um aumento na espessura da epiderme nas amostras dos animais irradiados. Para avaliar os resultados quantitativos, utilizou-se como análise estatística ANOVA one way e o teste post hoc de Tukey. Na espessura da epiderme, obtiveram-se diferenças significativas entre grupo controle e os grupos irradiados com 1.0, 1.5 e 2.0W/cm². CONCLUSÃO: Sob ação do US nas doses maiores houve alterações na epiderme e derme, respectivamente, o aumento da espessura e proliferação com adelgaçamento das fibras colágenas, o que alerta para possíveis implicações do uso do US em estética.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In vivo determination of the incorporated activity of Tc-99(m)-MDP (methylene diphosphonate) in bone tissue by means of a scintillation camera requires calibration of the device. This can be carried out by using an anthropomorphic physical phantom. In this work, a new human tibia and fibula phantom is presented to estimate incorporated activity to bone tissue. A tibia and a fibula, taken from a real skeleton, were used to develop the phantom. Images were acquired of the legs of 65 volunteers at different times of incorporation (minimum of 120 and maximum of 2500 min after injection) and count rates of such a region were obtained by means of a computer program. The calibration factor obtained was then used to assess the activity in the two bents. The final result is 0.4995 kBq per cpm for technetium. The proposed method can be used both for radiation protection purposes and for metabolism studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aims to determine the entrance surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence (TL) dosimetry. Twenty seven radiologic exams of dogs of different breed and sizes were performed. The radiation doses were assessed using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO(4):Dy) produced at Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN). The entrance surface skin dose range evaluated in this type of procedure was between 0.43 mGy to small size dogs and 4.22 mGy to big size dogs with repeated exams. The obtained results indicate that is extremely important the assessment of radiation doses involved in veterinary diagnostic radiology procedures, to evaluate the delivered doses to the animals, to be used as a parameter in the individual monitoring of pet's owners, who assist the animal positioning, and to protect occupationally exposed workers at the Veterinary Radiology Clinics. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the general relativistic description of gravitation, geometry replaces the concept of force. This is possible because of the universal character of free fall, and would break down in its absence. on the other hand, the teleparallel version of general relativity is a gauge theory for the translation group and, as such, describes the gravitational interaction by a force similar to the Lorentz force of electromagnetism, a non-universal interaction. Relying on this analogy it is shown that, although the geometric description of general relativity necessarily requires the existence of the equivalence principle, the teleparallel gauge approach remains a consistent theory for gravitation in its absence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste trabalho é descrever a síntese e a caracterização óptica de uma solução sólida de óxido de zircônio contendo ítrio e lantânio. Foram misturados citrato de zircônio, nitrato de ítrio e nitrato de lantânio nas proporções 94 mol% ZrO2-6 mol% Y2O3 e 92 mol% ZrO2-6 mol % Y2O3-2 mol % La2O3. A análise de espectroscopia de absorção no infravermelho com tranformada de Fourier mostra material orgânico em decomposição e a análise térmica mostra a transformação de fases da zircônia tetragonal para monoclínica, a perda de água e a desidroxilação do zircônio. A análise por difração de raios X mostra formação de fases homogênea de ZrO2-Y2O3-La2O3 demonstrando que a adição de lantânio não provoca formação de fases, promovendo uma solução sólida baseada em zircônia cúbica. Os espectros de fotoluminescência mostram bandas de absorção em 562 nm e 572 nm (350 ºC) e bandas de absorção específicas em 543 nm, 561 nm, 614 nm e 641 nm (900 ºC). O efeito fotoluminescente a baixas temperaturas é causado por defeitos como (Y Zr,Y O)', (2Y Zr,V O)'' e V O. As emissões em 614 nm e 641 nm são causadas pela transição O-2p -> Zr-4d. Uma emissão em 543 nm pode ser atribuída a centros LaO8 com transição O-2p -> La-5d.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The free action for massless Ramond-Ramond fields is derived from closed superstring field theory using the techniques of Siegel and Zwiebach. For the uncompactified Type IIB superstring, this gives a manifestly Lorentz-covariant action for a self-dual five-form field strength. Upon compactification to four dimensions, the action depends on a U(1) field strength from 4D N = 2 supergravity. However, unlike the standard Maxwell action, this action is manifestly invariant under the electromagnetic duality transformation which rotates F-mn into epsilon(mnpq)F(pq).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, we present an approach for neutron fluence measurements based on natural thorium thin films and natural uranium-doped glasses calibrated through natural uranium thin films to be used for dating with the Fission-Track Method (FTM). This neutron dosimetry approach allows the employment of FTM even when dating is carried out using low neutron themalization facilities. Besides, it makes possible the determination of the Th/U ratio of the mineral to be dated. Durango apatite which is often employed in FTM as an age standard was analyzed. This apatite presented a fairly high Th/U ratio, 29.9 +/- 1.7. Th fissions were 18%, 12% and 10% of the total for irradiations where thermal to fast neutron flux ratios were 2.4, 4.4 and 5,2, respectively. These results show that Th fission must be considered for this apatite, when not well-thermalized irradiation facilities are used. The ratio between spontaneous and induced track length, L(S)/L(1), close to 0.89, indicates a certain amount of rejuvenation of the age of Durango apatite. Therefore, its apparent age should be corrected, the application of a technique based on track-length measurements produced a corrected age of 29.7 +/- 1.1 Ma, consistent with the independent reference age of this apatite (31.4 +/- 0.5 Ma). This result represents a support for viability of the neutron dosimetry approach studied in this work for FTM.(C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Groups of Wistar rats were fed with ration doped with uranyl nitrate at concentration A ranging from 0.5 to 100 ppm, starting after the weaning period and lasting until the postpuberty period when the animals were sacrificed. Uranium in the ashes of bones was determined by neutron activation analysis. It was found that the uranium concentration in the bones. as a function of A, exhibits a change in its slope at similar to20 ppm-a probable consequence of the malfunctioning of kidneys. The uranium transfer coefficient was obtained and an analytical expression was fitted into the data. thus allowing extrapolation down to low doses. Internal and localized doses were calculated. Absorbed doses exceeded the critical dose. even for the lowest uranium dosage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The 2,4-dichlorophenoxyacetic acid (2,4-D) is one of the most applied herbicides around the world to control broad leave herbs in many crops: In this study, a method was developed for simultaneous extraction and determination of 2,4D and its major transformation product, i.e., the 2,4-dichlorophenol (2,4-DCP), in soil samples. The herbicide and its degradation product were extracted twice from soil samples, after acidification, by dichloromethane on ultrasound system for 1 h. Both extracts were combined and filtrated in qualitative filter paper and Celitee. The total extract was concentrated in rotatory evaporator, dried under N-2 and finally dissolved in 1 ml of methanol. High Performance Liquid Chromatography with UV detection at 230 nm was used for analysis. Recoveries were obtained from soil samples fortified at 0.1, 1.0, 2.0, 3.0 and 4.0 mg kg(-1) levels and the results varied from 85 to 111% (for 2,4-D) and from 95 to 98% (for 2,4-DCP). For both compounds, the limits of quantification were 0.1 mg kg(-1), which were the loss level at which the accuracy and the precision were studied. Nevertheless, the limits of detection, calculated by considering the blank standard deviation and the minimum concentration level, were 0.03 and 0.02 mg kg for 2,4-D and 2,4-DCP, respectively. This proposed method was applied to soil samples of eucalyptus crops, which was previously treated with the herbicide. Despite that, neither 2,4-D nor its degradation product were detected 30 days after the herbicide application. (C) 2003 Elsevier B.V. B.V. All rights reserved.