926 resultados para thermal residual stress


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: This study evaluated the effect of quantity of resin composite, C-factor, and geometry in Class V restorations on shrinkage stress after bulk fill insertion of resin using two-dimensional finite element analysis.Methods: An image of a buccolingual longitudinal plane in the middle of an upper first premolar and supporting tissues was used for modeling 10 groups: cylindrical cavity, erosion, and abfraction lesions with the same C-factor (1.57), a second cylindrical cavity and abfraction lesion with the same quantity of resin (QR) as the erosion lesion, and then all repeated with a bevel on the occlusal cavosurface angle. The 10 groups were imported into Ansys 13.0 for two-dimensional finite element analysis. The mesh was built with 30,000 triangle and square elements of 0.1 mm in length for all the models. All materials were considered isotropic, homogeneous, elastic, and linear, and the resin composite shrinkage was simulated by thermal analogy. The maximum principal (MPS) and von Mises stresses (VMS) were analyzed for comparing the behavior of the groups.Results: Different values of angles for the cavosurface margin in enamel and dentin were obtained for all groups and the higher the angle, the lower the stress concentration. When the groups with the same C-factor and QR were compared, the erosion shape cavity showed the highest MPS and VMS values, and abfraction shape, the lowest. A cavosurface bevel decreased the stress values on the occlusal margin. The geometry factor overcame the effects of C-factor and QR in some situations.Conclusion: Within the limitations of the current methodology, it is possible to conclude that the combination of all variables studied influences the stress, but the geometry is the most important factor to be considered by the operator.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The increasing demand for electrical energy and the difficulties involved in installing new transmission lines presents a global challenge. Transmission line cables need to conduct more current, which creates the problem of excessive cable sag and limits the distance between towers. Therefore, it is necessary to develop new cables that have low thermal expansion coefficients, low densities, and high resistance to mechanical stress and corrosion. Continuous fiber-reinforced polymers are now widely used in many industries, including electrical utilities, and provide properties that are superior to those of traditional ACSR (aluminum conductor steel reinforced) cables. Although composite core cables show good performance in terms of corrosion, the contact of carbon fibers with aluminum promotes galvanic corrosion, which compromises mechanical performance. In this work, three different fiber coatings were tested (phenol formaldehyde resin, epoxy-based resin, and epoxy resin with polyester braiding), with measurements of the galvanic current. The use of epoxy resin combined with polyester braiding provided the best inhibition of galvanic corrosion. Investigation of thermal stability revealed that use of phenol formaldehyde resin resulted in a higher glass transition temperature. On the other hand, a post-cure process applied to epoxy-based resin enabled it to achieve glass transition temperatures of up to 200 degrees C. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to evaluate the application of early age thermal conditioning (TC) and dietary electrolyte balances (DEB) to minimize the effect of heat stress. A total of 240 Cobb 500 1-d-old male broiler chicks was randomly allocated to 24 floor pens with six replicates per treatment in a 2x2 factorial arrangement (with and without TC and with and without DEB). Dietary treatments consisted: (T1) a traditional diet without TC; (T2) traditional diet with TC; (T3) with the application of dietary electrolyte and without TC and (T4) application of dietary electrolyte with TC. The thermal conditioning was conducted at 5 d of age (36°C for 24 h), only half of the batch (120 birds). After this period, all birds were transferred to boxes of 1.5 x 3m (10 birds / box), with wood shavings reused as litter. Chicks were exposed to chronic heat stress (32°C) for 6 h from 35 to 39 d of age, in all treatments, being electronically monitored the temperature and humidity of the microclimate of the birds. Feed and water were provided ad libitum, even during periods of stress. Were measured performance data (weight gain, feed intake and feed conversion) and mortality rate. Data were subjected to ANOVA using the GLM procedures of SAS. The results of this study demonstrated no interaction effects of all evaluated parameters (performance and mortality). Therefore, no synergism occurred when both strategies (TC and DEB) were applied. Only the first week there was prejudice on broiler performance with the application of the TC and apparently the technique of early age thermal conditioning no improve the resistance of broilers to chronic heat stress. On the other hand, DEB had significantly favorable effects (P<0.05) on performance and minimized mortality immediately after application of the TC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The results obtained in the August and December 2003, August 2004 and January 2005 oceanographic campaigns in the northern region of the Todos os Santos Bay (lat. 12 degrees 44.5`S; long. 038 degrees 35.00`W) between the Madre de Deus and Mare islands are analyzed. Instruments of continuous and discrete samplings were used to measure hydrographic properties currents and tides. The water mass of the northern region of the bay is forced by semidiurnal and mesotides of form number 0.08 and the lunar component M(2) height was estimated at 91cm. The time series of the surface currents indicated movements in the N/S direction, forced by the tide with maximum magnitudes of 0.73 m.s(-1) on the December 2003 campaign. However, in August 2004 the currents were dominated by the wind stress forcing, with a maximum speed of 1.85 m.s(-1) and SE direction. Near the bottom, the influence of the tide is not as evident, with a decrease in intensity due to internal and bottom friction, with a maximum velocity of 0.17 m.s(-1). The thermal and haline structures were weakly horizontally, as well as vertically stratified, with extreme values varying in the intervals 23 degrees C (August, 2004) to 28 degrees C (December, 2003) and 31.0 psu (August, 2003) to 36.0 psu (December, 2003), respectively. Some conclusions may be drawn from these results: i) The signs of the dilution of the fresh water discharges of the Caipe, Mataripe and Sao Paulo rivers in the region under the influence of the RLAM were observed only during the winter periods, but in the summer the region was flooded by waters of oceanic origin and the salinities above 36.0 indicated TW mass intrusion; ii) The N-S circulation near the RLAM is strongly dominated by the tide, and the importance of the M(2) component was unequivocal, however, the E-W component presented some tidal modulation away from abrupt bottom topographical changes, and iii) The residual series, calculated as the difference between the original and modeled, is about 1/4 of the original and confirmed its semidiurnal character.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The current study aimed to determine the role of oxidants in cardiac and pulmonary toxicities induced by chronic exposure to ROFA. Eighty Wistar rats were divided into four groups: G1 (10 mu L Saline), G2 (ROFA 50 mu g/10 mu L), G3 (ROFA 250 mu g/10 mu L) and G4 (ROFA 500 mu g/10 mu L). Rats received ROFA by nasotropic instillation for 90 days. After that, they were euthanized and bronchoalveolar lavage (BAL) was performed for total count of leukocytes, protein and lactate dehydrogenase (LDH) determinations. Lungs and heart were removed to measure lipid peroxidation (MDA), catalase (CAT) and superoxide dismutase (SOD) activity. BAL presented an increase in leukocytes count in G4 in comparison to the Saline group (p = 0.019). In lung, MDA level was not modified by ROFA, while CAT was higher in G4 when compared to all other groups (p = 0.013). In heart, G4 presented an increase in MDA (p = 0.016) and CAT (p = 0.027) levels in comparison to G1. The present study demonstrated cardiopulmonary oxidative changes after a chronic ROFA exposure. More specifically, the heart tissue seems to be more susceptible to oxidative effects of long-term exposure to ROFA than the lung.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Statement of problem. The retention of an Aramany Class IV removable partial dental prosthesis can be compromised by a lack of support. The biomechanics of this obturator prosthesis result in an unusual stress distribution on the residual maxillary bone. Purpose. This study evaluated the biomechanics of an Aramany Class IV obturator prosthesis with finite element analysis and a digital 3-dimensional (3-D) model developed from a computed tomography scan; bone stress was evaluated according to the load placed on the prosthesis. Material and methods. A 3-D model of an Aramany Class IV maxillary resection and prosthesis was constructed. This model was used to develop a finite element mesh. A 120 N load was applied to the occlusal and incisal platforms corresponding to the prosthetic teeth. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis were expressed in MPa. Results. Under posterior load, tensile and compressive stresses were observed; the tensile stress was greater than the compressive stress, regardless of the bone region, and the greatest compressive stress was observed on the anterior palate near the midline. Under an anterior load, tensile stress was observed in all of the evaluated bone regions; the tensile stress was greater than the compressive stress, regardless of the bone region. Conclusions. The Aramany Class IV obturator prosthesis tended to rotate toward the surgical resection when subjected to posterior or anterior loads. The amount of tensile and compressive stress caused by the Aramany Class IV obturator prosthesis did not exceed the physiological limits of the maxillary bone tissue. (J Prosthet Dent 2012;107:336-342)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE. The objective of our study was to evaluate the effectiveness of MRI in the detection of possible residual lesions after radiofrequency ablation (RFA) in the treatment of breast cancer. SUBJECTS AND METHODS. We prospectively evaluated 14 patients who had undergone ultrasound-guided core biopsies diagnostic of invasive ductal carcinoma (IDC; range of diameters, 1.0-3.0 cm) and then ultrasound-guided percutaneous RFA with sentinel node biopsy as the primary treatment. Breast MRI was performed 1 week before RFA to evaluate tumor extension and again 3 weeks after RFA to verify the presence of possible residual lesions. Conventional surgical resection of the tumors was performed 1 week after RFA. The MRI findings were compared with histopathologic analyses to confirm the presence or absence of residual tumor. RESULTS. There was no residual enhancement in seven lesions on the postablation breast MRI scans. These findings were confirmed by negative histopathologic findings in the surgical specimens. The MRI scans of five patients showed small areas of irregular enhancement that corresponded to residual lesions. In the two remaining patients, we observed enhancement of almost the entire lesion, indicating that RFA had failed. CONCLUSION. Breast MRI is effective in detecting residual lesions after RFA in patients with IDC.