945 resultados para tablet compression
Resumo:
Objectives: The purpose of this study was to measure the intraobserver and interobserver reliability of magnetic resonance detection of cervical spondylotic myelopathy with and without operational guidelines. Methods: Seven radiologists examined images from 10 patients with cord signal abnormalities and clinical signs of myelopathy. Radiologist examined films twice, with and without operational guidelines designed to define stenotic changes, while blinded to the clinical findings of the patients. Analyses included a Fleiss kappa assessment of intraobserver and interobserver reliability. Results: Results demonstrated high percentage of agreement and strong intraobserver reliability and variable Fleiss kappa, values for interobserver assessment. Operational guidelines did not improve the intraobserver or interobserver agreement. Conclusion: Although the percentage of agreement was high in some cases, the kappa agreement was low-most likely a result of the base rate problem of a kappa analysis. Sample bias toward severe degenerative changes resulted in highly prevalent selections and kappa adjusted values. Nonetheless, the results do suggest that substantial intraobserver kappa agreement and a wide range of interobserver kappa agreement exists among trained radiologists during detection of stenotic changes associated with cervical spondylotic myelopathy.
Resumo:
A free-piston driver that employs entropy-raising shock processes with diaphragm rupture has been constructed, which promises significant theoretical advantages over isentropic compression. Results from a range of conditions with helium and argon driver gases are reported. Significant performance gains were achieved in some test cases. Heat losses are shown to have a strong effect on driver processes. Measurements compare well with predictions from a quasi-one-dimensional numerical code.
Resumo:
Objectives-This study adopted a concurrent task design and aimed to quantify the efficiency and smoothness of voluntary movement in Tourette's syndrome via the use of a graphics tablet which permits analysis of movement profiles. In particular, the aim was to ascertain whether a concurrent task (digit span) would affect the kinematics of goal directed movements, and whether patients with Tourette's syndrome would exhibit abnormal functional asymmetries compared with their matched controls. Methods-Twelve patients with Tourette's syndrome and their matched controls performed 12 vertical zig zag movements, with both left and right hands (with and without the concurrent task), to large or small targets over long or short extents. Results-With short strokes, controls showed the predicted right hand superiority in movement time more strongly than patients with Tourette's syndrome, who instead showed greater hand symmetry with short strokes. The right hand of controls was less force efficient with long strokes and more force efficient with short strokes, whereas either hand of patients with Tourette's syndrome was equally force efficient, irrespective of stroke length, with an overall performance profile similar to but better than that of the controls' left hand. The concurrent task, however, increased the force efficiency of the right hand in patients with Tourette's syndrome and the left hand in controls. Conclusions-Patients with Tourette's syndrome, compared with controls, were not impaired in the performance of fast, goal directed movements such as aiming at targets; they performed in certain respects better than controls. The findings clearly add to the growing literature on anomalous lateralisation in Tourette's syndrome, which may be explained by the recently reported loss of normal basal ganglia asymmetries in that disorder.
Resumo:
Our aim was to analyze the influence of subtle cochlear damage on temporal auditory resolution in tinnitus patients. Forty-eight subjects (hearing threshold <= 25 dB HL) were assigned to one of two experimental groups: 28 without auditory complaints (mean age, 28.8 years) and 20 with tinnitus (mean age, 33.5 years). We analyzed distortion product otoacoustic emission growth functions (by threshold, slope, and estimated amplitude), extended high-frequency thresholds, and the Gaps-in-Noise test. There were differences between the groups, principally in the extended high-frequency thresholds and the Gaps-in-Noise test results. Our findings suggest that subtle peripheral hearing impairment affects temporal resolution in tinnitus, even when pure-tone thresholds as conventionally measured appear normal. Copyright (C) 2010 S. Karger AG, Basel
Resumo:
A 74 year old patient, EW, with dorsolateral frontal cortical compression due to hyperostosis frontalis interna, in the absence of the Morgagni or Stewart-Morel syndromes, is described. In addition to conventional neuropsychological measures EW was administered one nonspatial and two spatial self ordered working memory tasks, as well as a standard measure of fluid intelligence or g. She showed impaired performance on all three self ordered working memory tasks compared with a normal control group of 10 subjects matched for age, education, sex, and IQ. By contrast, her performance on the fluid intelligence test was comparable with that of the controls. It is concluded that the compression of dorsolateral frontal cortex accompanying hyperostosis frontalis interna may produce selective cognitive impairment.
Resumo:
Introduction: Current advances in frame modeling and computer software allow stereotactic procedures to be performed with great accuracy and minimal risk of neural tissue or vascular injury. Case Report: In this report we associate a previously described minimally invasive stereotactic technique with state-of-the-art 3D computer guidance technology to successfully treat a 55-year-old patient with an arachnoidal cyst obstructing the aqueduct of Sylvius. We provide 1 detailed technical information and discuss how this technique deals with previous limitations for stereotactic manipulation of the aqueductal region. We further discuss current advances in neuroendoscopy for treating obstructive hydrocephalus and make comparisons with our proposed technique. Conclusion: We advocate that this technique is not only capable of treating this pathology but it also has the advantages to enable reestablishment of physiological CSF flow thus preventing future brainstem compression by cyst enlargement.
Resumo:
PURPOSE: To compare the ability of Fourier-domain (FD) optical coherence tomography (3D OCT-1000; Top, con, Tokyo, Japan) and time domain (TD) OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA) to detect axonal loss in eyes with band atrophy (BA) of the optic nerve. DESIGN: Cross-sectional study. METHODS: Thirty-six eyes from 36 patients with BA and temporal visual field (VF) defect from chiasmal compression and 36 normal eyes were studied. Subjects were submitted to standard automated perimetry and macular and retinal nerve fiber layer (RNFL) measurements were taken using 3D OCT-1000 and Stratus OCT. Receiver operating characteristic (ROC) curves were calculated for each parameter. Spearman correlation coefficients were obtained to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss. Measurements from the two devices were compared. RESULTS: Regardless of OCT device, all RNFL and macular thickness parameters were significantly lower in eyes with BA compared with normal eyes, but no statistically significant difference was found with regard to the area under the ROC curve. Structure-function relationships were also similar for the two devices. In both groups, RNFL and macular thickness measurements were generally and in some cases significantly smaller with 3D OCT-1000 than with Stratus OCT. CONCLUSIONS: The introduction of FD technology did not lead to better discrimination ability for detecting BA of the optic nerve compared with TD technology when using the software currently provided by the manufacturer. 3D OCT-1000 FD OCT RNFL and macular measurements were generally smaller than TD Stratus OCT measurements. Investigators should be aware of this fact when comparing measurements obtained with these two devices. (Am J Oplathalmol 2009;147: 56-63. (c) 2009 by Elsevier Inc. All rights reserved.)
Resumo:
Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.
Resumo:
Objective: To standardize an experimental model of spinal cord injury in Wistar rats, computerized weight fall impact equipment were used and the parameters were used determined by the multicenter animal spinal cord injury study - MASCIS. Methods: Thirty rats were used, with age varying between 20 and 25 weeks, and weight ranging from 200 to 300g for females, and from 232 to 430g for males. The impacts were done with weights of 10g starting from 12.5, 25 and 50 mm of height, and the impact speed and compression coefficient were obtained. The impact occurred on the surface of the spinal cord at the level of the tenth thoracic vertebra after laminectomy. Vital signs were monitored and gas analysis was made before and after the spinal cord injury. The lesion volume was evaluated by the quantitative analysis of sodium and potassium ions. Results: Statistically significant correlations were verified among the lesion volume and the mechanical parameters. The lesion volume caused by the fall from 50mm height was superior to that of the 12.5 and 25mm, which didn`t differ from each other. Conclusion: The model demonstrated itself to be effective and capable of generating standard spinal cord injuries on Wistar rats.
Resumo:
Objective Traumatic spinal Cord injuries are common in patients with high energy trauma and have significant morbidity and mortality rates as well as high psychological and social costs causing a major impact on public health To date the treatment of such lesions remains controversial with various studies in the literature comparing the results of non surgical treatment with immediate early or late surgical decompression The objective of the present study is to compare the results of immediate and early (within 1 hour) spinal Cord decompression Methods In the belief that the surgical treatment obtains the best result this experimental study has a case control design with histopathological and functional analysis of the results of surgical treatment of 25 Wistar mice submitted to posterior laminectomy immediately or after one hour of spinal Cord compression Results in terms of functional and neurological deficit the responses were better in the mice treated with immediate surgical decompression than in those treated one hour after the lesion (p=0 036) Conclusion The earlier the decompression of spinal Cord injuries is performed the better the end results in terms of the function and presence of neurological deficit
Resumo:
Objective: Acrylic cement has been used for years on orthopaedic surgeries, especially on knee arthroplasties, deserving special attention when added to antibiotics (for treatment of deep bone infections) or stains (to facilitate its removal). The present study was conducted in order to evaluate potential mechanical differences between the orthopaedic cement itself and when this is added to antibiotic and/or stains. Methods: Surgical bone cement Simplex@P Stryker, vancomycin and methylene blue were used, and the mixtures were submitted to physical and mechanical tests according the ABNT NBR ISO 5833 rule. The parameters studied here were: time for mass formation, intrusion capability, resistance to compression, resistance to flexion and maximum temperature reached by the mixtures. Results: The evaluated mixtures were approved as to mass formation, maximum temperature, intrusion capability and resistance to compression. Only the one containing pure cement was approved on the flexion essay. Conclusion: The addition of vancomycin and/or methylene blue to Surgical Simplex@P Stryker bone cement reduces its resistance to flexion, being unacceptable by the ABNT NBR ISO 5833 rule.
Resumo:
Objective To evaluate the effect of the addition of methyltestosterone to estrogen and progestogen therapy on postmenopausal sexual energy and orgasm. Methods Sixty postmenopausal women in a stable relationship with a partner capable of intercourse, and presenting sexual complaints that appeared after menopause, were randomly divided into two groups: EP (n=29) received one tablet of equine estrogens (CEE) 0.625mg plus medroxyprogesterone acetate (MPA) 2.5mg and one capsule of placebo; EP+A (n=31) received one tablet of CEE 0.625mg plus MPA 2.5mg and one capsule of methyltestosterone 2.0mg; The treatment period was 12 months. The effects of treatment on sexual energy were assessed using the Sexual Energy Change Scale. The ability to reach orgasm in sexual relations with the partner was verified through monthly calendars and by calculating the ratio between monthly frequency of orgasms in sexual relations and monthly sexual frequency. Results There was a significant relationship between improvement in level of sexual energy and the addition of methyltestosterone to CEE/MPA treatment (p=0.021). No significant effect on orgasmic capacity was noted after the treatment period. Conclusion Addition of methyltestosterone to CEE/MPA therapy may increase sexual energy, but might not affect the ability to obtain orgasm in sexual relations.
Resumo:
Objective: To investigate clinical and MRI findings that are predictive of both visual loss in patients with pituitary adenomas and visual recovery after treatment. Design: Cohort study. Participants: Thirty patients (60 eyes) with pituitary adenoma. Methods: Patients underwent neuro-ophthalmic examination and MRI before and after optic chiasm decompression. Visual field (VF) was assessed using the mean deviation in standard automated perimetry (SAP) and temporal mean defect, the average of 22 temporal values of the total deviation plot. Tumour size was measured on sagittal and coronal cuts. Results: Visual loss was found in 47 eyes; 35 had optic atrophy (subtle in 9, moderate in 14, and severe in 12). Before treatment, the average SAP mean deviation and temporal mean defect were -11.78 (SD 8.56) dB and -18.66 (SD 11.20) dB, respectively. The chiasm was 17.3 (SD 6.2, range 10-34) mm above the reference line on the sagittal and 21.8 (SD 8.3, range 12-39) mm on the coronal images. Tumour size correlated with the severity of VF defect. VF improvement occurred in 80% of eyes after treatment. The degree of optic atrophy, visual loss, and tumour size were significantly associated with improvement after treatment. Conclusions: The best predictive factor for visual loss was tumour size, and factors related to visual recovery were the degree of optic atrophy, the severity of VF defect, and the tumour size. Diagnosing pituitary adenomas before optic atrophy becomes severe may be related to a better prognosis in such patients.
Resumo:
P>Background There is good evidence for the use of compression for some clinical indications but little is known about dosimetry in compression. Objective The aim of this work was to evaluate whether or not the use of compression stockings during part of the day would help in the reduction of evening oedema in patients with clinical, epidemiological, anatomical and physiopathological (CEAP) classifications C0 and C1. Methods The effects of elastic compression stockings on volumetric variations during the working day were evaluated for the legs of two men and 18 women (40 legs). The inclusion criterion was classification as C0 (10 legs) or C1 (30 legs) according to the CEAP criteria. Participants used three-quarter-length elastic compression stockings (20-30 mmHg) on three consecutive days for the entire day or only for the morning or they did not use the stockings at all. Volumetry using the water displacement technique was performed in the morning and in the evening. When the patients wore the stockings only during the morning, volumetry was also performed at 13:00 h. Results Significant increases in volume were observed for both legs when stockings were not used compared with the use of stockings in the morning only. After removing the stockings, both legs had significant increases in volume in the afternoon. However, use for half the day was better than not using the stockings at all. Conclusions The use of elastic compression stockings can reduce volumetric variations during working hours, with the use of stockings for the entire day being better than for just half the day.