765 resultados para procurement measuring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

It has been shown that people of all ages can benefit from the topical and systemic effects of water fluoridation. However, the increase in consumption of bottled water, either to substitute for or supplement consumption of water from public sources, has implications for safe fluoride supplementation. Taking that into consideration, in 1995 we analyzed the fluoride content in 31 commercial brands of mineral water in the region of Araraquara, state of Sao Paulo, Brazil. Fluoride concentration as determined by our analysis was compared to the concentration of fluoride specified on each label. Only 25% of the products studied listed the fluoride concentration on their labels. In addition, among 31 mineral water brands, 26 listed the date when the chemical analysis to determine chemical composition had been performed. Of these, 20 had not been put through the annual chemical analysis determined by Brazilian law. Based on these results, if the mineral waters tested had been the only source of drinking water, fluoride supplementation would have been necessary in 69% of the samples analyzed. In the case of children up to 6 years of age who use products containing fluoride, such as topical gels, mouthwashes or toothpastes, supplementation should be recommended only if commercially bottled water is the only source of water used, not only for drinking but for cooking as well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pulsed electric acoustic technique, PEA, has been usually applied to probe space charge profiles in polymers. Preliminary PEA results using a ferroelectric ceramic are presented. If the reverse applied electric field i of the order of the coercive field the switching polarization process occurs in a period larger than hundreds of seconds. Such a slow process allows one to use the PEA setup to follow the polarization switching dynamics and determine the electric field profile. The PEA signal obtained in the lead zirconate-titanate doped with niobium ceramic, PZTN, indicates that the polarization distribution and field are not uniform during the switching period. We were also able to observe that the acoustic wave velocity and attenuation depends on the stage of the polarization switching, which agrees with results obtained using the ultrasonic method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pulsed electric acoustic technique, PEA, have been usually applied to probe space charge profiles in polymers. In this work we show preliminary results obtained with lead zirconate-titanate and niobium, PZTN, ferroelectric ceramic samples. Experiments showed that induced charge densities on sample electrodes are mainly due to the ferroelectric polarization of the sample. We present results of the typical PEA response and the procedure to deconvolute the signal in order to obtain the charge densities and the electric field profiles. The PEA setup allows us to show a non-uniform polarization during ferroelectric switching.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel instrument for measurement of X-ray intensity from mammography consists of a sensitive pyro-electric detector, a high-sensitivity, low-noise current-to-voltage converter, a microcontroller and a digital display. The heart of this device, and what makes it unique is the pyro-electric detector, which measures radiation by converting heat from absorbed incident X-rays into an electric current. This current is then converted to a voltage and digitised. The detector consists of a ferro-electric crystal; two types were tested; lithium tantalate and lithium niobate. X-ray measurement in mammography is challenging because of its relatively low photon energy range, from 11 keV to 15 keV equivalent mean energy, corresponding to a peak tube potential from 22 to 36 kV. Consequently, energy fluence rate or intensity is low compared with that of common diagnostic X-ray. The instrument is capable of measuring intensities as low as 0.25 mWm -2 with precision greater than 99%. Not only was the instrument capable of performing in the clinical environment, with high background electromagnetic interference and vibration, but its performance was not degraded after being subjected to 140 roentgen (3.6 × 10 -2 C kg -2 air) as measured by piezo-electric (d 33) or pyro-electric coefficients. © IFMBE 2005.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Outsourcing is related to the action which an organization deals with its suppliers through a kind of business contract where a specific activity or service has been hired to be made. The outsourcing of some activities has become a common practice in the industry, nowadays. It reduces costs, significantly, in the production process and, at the same time, adds some values to the business organization. However it is necessary to measure the performance of these activities. Data Envelopment Analysis (DEA) is a non-parametric method useful to measure comparative performance. It has a wide range of applications measuring comparative efficiency. The Analytic Hierarchy Process (AHP) is a multiple criteria decision-making method that uses hierarchic structures to represent a decision problem and then develops priorities for the alternatives based on the decision-maker's judgments. This paper presents an integrated application based on DEA and AHP to evaluate the efficiency of subcontracted companies in a Brazilian aerospace factory. © 2007 Springer-Verlag London Limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies on the distribution of plantar pressure between the sole of the foot and the ground were developed before the 19th century. Currently, the most often employed plantar pressure measurement systems are Pedar® and FScan®, which have restrictions such as operational difficulty and high cost. In the present study, a device was constructed from two pressure plates capable of measuring plantar forces in discreet areas of the feet at a low cost, using strain-gages attached to sixteen strategic points of the mechanical elements. Sixteen prismatic beams were soldered to each frame, for which the free extremity of each beam represented a specific point of the foot. Two strain gauges were attached to each beam - one near the upper fixed extremity and the other near the lower fixed extremity. Using a Wheatstone bridge electric circuit, the gauges were used to measure the force acting on the extremity of the beam. Precision and accuracy of the prototype was about 10%. In some measurements, accuracy was 2%. The low precision and accuracy were mainly due to the restrictions of the available equipment, which only permitted four measurements at a time. Thus, it was necessary for participants to stand on the plates four separate times, which signified possible changes in the position of the feet on the pressure plates. Despite some limitations, the aim was achieved. The prototype has been used in some studies and represents a contribution to biomechanics, demonstrating the viability of using strain gauges.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

the aim of this study was to validate the Alternate Current Biosusceptometry (ACB) for monitoring gastric contractions in rats. In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed on rats with magnetic markers and SGs previously implanted under the gastric serosa. The effects of the prandial state in gastric motility profiles were obtained. The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation between the ACB and SG signal amplitude was higher in the postprandial than in the fasting state. Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation for fasting-state recordings. The contraction frequencies using ACB were 0.068 ± 0.007 Hz (postprandial) and 0.058 ± 0.007 Hz (fasting) and those using SG were 0.066 ± 0.006 Hz (postprandial) and 0.059 ± 0.008 Hz (fasting) (P < 0.003). When a magnetic tracer was ingested, there was a strong correlation and a small phasedifference between techniques. We conclude that ACB provides an accurate and sensitive technique for studies of GI motility in the rat. © 2010 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This paper aims to perform an empirical investigation about the constructs and indicators of the supply chain management practices framework. Design/methodology/approach: The measuring framework proposed is based on a survey that was carried out on 107 Brazilian companies. Statistical techniques were employed to verify, validate, and test the reliability of the constructs and their indicators. To validate this framework principal component analysis and structural equation modeling techniques were used. Findings: In general, previous studies suggest six constructs for measuring the supply chain management practices framework. However, in this study a framework was achieved with four constructs of supply chain management practices, namely, supply chain (SC) integration for production planning and control (PPC) support, information sharing about products and targeting strategies, strategic relationship with customer and supplier, and support customer order. This framework has adequate levels of validity and reliability. Research limitations/implications: The main limitation of this study was that only a small sample of companies in a single sector and country were surveyed, and therefore there needs to be further research considering the special conditions in other countries. Originality/value: This study investigated statistically set indicators to discuss the topic supply chain management practices. The framework obtained has good quality of validity and reliability indicators. Thus, an alternative framework has been added to measure supply chain management practices, which is currently a popular topic in the supply chain mainstream literature. Both defined constructs and the validated indicators can be used in other studies on supply chain management. © Emerald Group Publishing Limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present paper deals with numerical corrections factors proposed as a function of the clearness index in order to correct the diffuse solar irradiance measured with the Melo-Escobedo Shadowring Measuring Method (ME shadowring). The global irradiance was measured by an Eppley - PSP pyranometer ; direct normal irradiance by an Eppley-NIP pyrheliometer fitted to a ST-3 sun tracking device and the diffuse irradiance by an Eppley-PSP pyranometer fitted to a ME shadowring. The validations were performed by the MBE and RMSE statistical indicators. The results showed that the numerical correction factors were appropriate to correct the shadowring diffuse irradiance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Albumin concentrations in female Bronze turkeys were compared using agarose gel electrophoresis (AGE) and the bromocresol green (BCG) dye-binding method. The correlation coefficient observed for albumin in the BCG and AGE methods was low, and statistical differences were observed at paired t test (p < 0. 0001). Compared with electrophoresis, the BCG-binding method yielded significantly lower albumin values for female turkeys during laying season. © 2011 Springer-Verlag London Limited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to compare albumin concentrations in ring-necked pheasants (Phasianus colchicus) using two different dye-binding methods: the bromocresol green (BCG) and bromocresol purple (BCP). High positive correlation was observed for albumin in BCG and BCP methods. Compared to BCP, the BCG-binding method yielded significantly higher (p < 0. 0001) albumin values for adult female ring-necked pheasants. © 2012 Springer-Verlag London Limited.