986 resultados para mitral valve regurgitation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Transapical transcatheter valve procedures are performed through a left minithoracotomy and require apical sutures to seal the apical access site. The use of large-calibre devices compromises any attempt to fully perform the procedure with a thoracoscopic approach or percutaneously. We report our preliminary experience in animals with a new sutureless self-expandable apical occluder, engineered to perform transapical access site closure in a minimally invasive setting with large-size introducer sheaths. METHODS: The apical occluder with extendable waist was implanted in six young pigs during an acute animal study. Under general anaesthesia, animals (mean weight: 62 ± 8 kg) received full heparinization (heparin: 100 UI/kg; activated clotting time above 250 s). Through a median sternotomy, a 21-Fr Certitude? introducer sheath (outer diameter: 25 Fr) was placed over the wire into the cardiac apex. The delivery catheter carrying the constrained apical plug was inserted into the sheath and deployed under fluoroscopic control, whereas the Certitude? was retrieved. After protamine infusion, we observed and recorded the 1-h bleeding with standard haemodynamic parameters. Animals were sacrificed, and hearts analysed. RESULTS: Six apical closure devices were successfully introduced and deployed in six pig hearts through large-size apical sheaths at first attempt. In all animals, the plugs guaranteed immediate apical sealing and traces of blood were collected in the pericardium during the 1-h observational period (mean of 16 ± 3.4 ml of blood loss per animal). Haemodynamic parameters remained stable during the entire study period and no plug dislodgement was detected with normal systemic blood pressure (mean arterial mean blood pressure: 65 ± 7 mmHg). Post-mortem analysis confirmed the full deployment and good fixation of all plugs, without macroscopic damages to the surrounding myocardium. CONCLUSIONS: This sutureless self-expandable apical occluder is a simple device capable of sealing large-size apical access sites (20-35 Fr) in an acute animal study. This approach is a step further towards less invasive transapical valve procedures in the clinical setting, and further animal tests will be performed to confirm the long-term efficacy and safety of this device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The impact of early valve surgery (EVS) on the outcome of Staphylococcus aureus (SA) prosthetic valve infective endocarditis (PVIE) is unresolved. The objective of this study was to evaluate the association between EVS, performed within the first 60 days of hospitalization, and outcome of SA PVIE within the International Collaboration on Endocarditis-Prospective Cohort Study. METHODS: Participants were enrolled between June 2000 and December 2006. Cox proportional hazards modeling that included surgery as a time-dependent covariate and propensity adjustment for likelihood to receive cardiac surgery was used to evaluate the impact of EVS and 1-year all-cause mortality on patients with definite left-sided S. aureus PVIE and no history of injection drug use. RESULTS: EVS was performed in 74 of the 168 (44.3%) patients. One-year mortality was significantly higher among patients with S. aureus PVIE than in patients with non-S. aureus PVIE (48.2% vs 32.9%; P = .003). Staphylococcus aureus PVIE patients who underwent EVS had a significantly lower 1-year mortality rate (33.8% vs 59.1%; P = .001). In multivariate, propensity-adjusted models, EVS was not associated with 1-year mortality (risk ratio, 0.67 [95% confidence interval, .39-1.15]; P = .15). CONCLUSIONS: In this prospective, multinational cohort of patients with S. aureus PVIE, EVS was not associated with reduced 1-year mortality. The decision to pursue EVS should be individualized for each patient, based upon infection-specific characteristics rather than solely upon the microbiology of the infection causing PVIE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although surgical aortic valve replacement has been the standard of care for patient with severe aortic stenosis, transcatheter aortic valve implantation (TAVI) is now a fair standard of care for patients not eligible or high risk for surgical treatment. The decision of therapeutic choice between TAVI and surgery considers surgical risk (estimated by the Euro-SCORE and STS-PROM) as well as many parameters that go beyond the assessment of the valvular disease's severity by echocardiography: a multidisciplinary assessment in "Heart Team" is needed to assess each case in all its complexity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During transapical transcatheter aortic valve replacement (TA-TAVR), the apical closure remains a challenge for the surgeon, having the risk for ventricular tear and massive bleeding. Apical closure devices are already under clinical evaluation, but only a few can lead to a full percutaneous TA-TAVR. We describe the successful use of a 9-mm myocardial occluder (ventricular septal defect occluder) that was used to seal the apex after a standard TA-TAVR (using the Sapien XT 23-mm transcatheter valve and the Ascendra + delivery system). The placement of the nonmodified myocardial occluder was performed through the Ascendra + delivery system, with a very small amount of blood loss and an acceptable sealing of the apical tear. This approach is feasible and represents a further step toward true-percutaneous transapical heart valve procedures. Modified apical occluders are under evaluation in animal models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulmonary artery sarcomas are uncommon intracardiac tumours with poor prognosis. We report the case of a 69-year-old woman in good health presenting with rapidly progressive dyspnoea and an unfamiliar systolic murmur. Echocardiography revealed pulmonary valve stenosis due to an obstructing mobile mass. Imaging studies confirmed the presence of a contrast-enhancing lesion adherent to the valve, extending into the pulmonary trunk and right ventricular outflow tract, and suggestive of malignancy. Endovascular biopsy was attempted with no success. Surgical resection with autologous graft valve replacement and pulmonary artery reconstruction was performed. Postoperative histological examination confirmed the diagnosis of an undifferentiated pleomorphic sarcoma. Pulmonary artery sarcoma should be considered as a rare differential diagnosis in patients presenting with dyspnoea and a crescendo-decrescendo systolic murmur increasing with inspiration. Echocardiography is a useful first diagnostic approach but multi-imaging assessment is almost always necessary for definite diagnosis. Our case provides insights into the challenges met by cardiologists, radiologists and cardiac surgeons in the management of such cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the work is to study fluid flow behavior through a pinch valve and to estimate the flow coefficient (KV ) at different opening positions of the valve. The flow inside a compressed valve is more complex than in a straight pipe, and it is one of main topics of interest for engineers in process industry. In the present work, we have numerically simulated compressed valve flow at different opening positions. In order to simulate the flow through pinch valve, several models of the elastomeric valve tube (pinch valve tube) at different opening positions were constructed in 2D-axisymmetric and 3D geometries. The numerical simulations were performed with the CFD packages; ANSYS FLUENT and ANSYS CFX by using parallel computing. The distributions of static pressure, velocity and turbulent kinetic energy have been studied at different opening positions of the valve in both 2D-axisymmetric and 3D experiments. The flow coefficient (KV ) values have been measured at different valve openings and are compared between 2D-axisymmetric and 3D simulation results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: avaliar as áreas das válvulas atrioventriculares (tricúspide e mitral) de fetos normais por meio da ultrassonografia tridimensional (US3D) utilizando o método STIC (spatiotemporal image correlation). MÉTODOS: realizou-se estudo de corte transversal com 141 mulheres entre a 18ª e a 33ª semana de gestação. As medidas dos volumes cardíacos foram obtidas por um transdutor volumétrico transabdominal acoplado ao aparelho Voluson 730 Expert. Utilizou-se como referência o plano de quatro câmaras com a ROI (região de interesse) posicionada a partir dos ventrículos, sendo a área das valvas delimitada manualmente. Para conhecer a correlação das áreas valvulares com a idade gestacional, foram construídos diagramas de dispersão e calculou-se o coeficiente de correlação de Pearson (r). Foram calculadas médias, medianas, desvios padrão (DP), valores máximo e mínimo. Para se determinar intervalos de referência das áreas valvulares em função da idade gestacional, seguiu-se o modelo de regressão linear simples, utilizando o método de Altman, com nível de significância de p<0,05. Para o cálculo da reprodutibilidade intraobservador, utilizou-se o coeficiente de correlação intraclasse (CCI) e o gráfico de Bland-Altman. RESULTADOS: as áreas valvulares tricúspide e mitral se correlacionaram com a idade gestacional (r=0,80 para a tricúspide e r=0,79 para a mitral), sendo que a média aumentou da válvula tricúspide e mitral, respectivamente, de 0,22±0,10 cm² e de 0,23±0,10 cm² na 18º semana para 0,92±0,29 cm² e para 1,08±0,41 cm² na 33º semana de gestação. A reprodutibilidade intraobservador resultou em CCI=0,993 (IC95% 0,987; 0,996), com diferença média de 0,01 cm² (DP±0,2 cm² e IC95%±0,4 cm²). CONCLUSÃO: intervalos de referência para a área das valvares mitral e tricúspide entre a 18ªe a 33ª semana de gestação foram determinados pela US3D e se mostraram altamente reprodutíveis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Luettelo Kansalliskirjastossa olevan Kaarlo Väinö Valveen arkiston sisällöstä

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé - Les données concernant la prise en charge chirurgicale de la maladie tricuspidienne reposent sur des études de cohortes à petite échelle et peu d’entre elles se sont intéressées aux résultats échocardiographiques et aux facteurs de risque de mortalité et de morbidité. Une étude de cohorte rétrospective descriptive et analytique fut effectuée pour analyser l’expérience de l’Institut de Cardiologie de Montréal concernant la chirurgie de la VT. Les données ont été récoltées à l’aide des dossiers médicaux. Durant la période 1977-2008, 792 PVT et 134 RVT furent effectués (âge médian : 62 ans). La mortalité opératoire était de 13,8%. Les taux de survie actuarielle à 5, à 10 et à 15 ans étaient respectivement de 67±2%, de 47±2% et de 29±2%. Au dernier suivi, de l’IT ≥3/4 était présente chez 31% des patients du groupe PVT et chez 12% des patients du groupe RVT (p<0,001). La classe fonctionnelle NYHA s’est améliorée significativement au dernier suivi par rapport à la période pré-opératoire (p<0,001). L’analyse de propension montre que par rapport à une PVT, un RVT est associé significativement à des taux de mortalité opératoire et tardive accrus, mais à moins d’IT ≥2/4 ou ≥3/4 lors du suivi. Cette étude montre que malgré le risque chirurgical substantiel associé à la chirurgie de la VT, les patients bénéficient d’une amélioration fonctionnelle significative. Les facteurs de risque de mortalité et de morbidité sont décrits et des études de sous-groupes sur la chirurgie tri-valvulaire et la chirurgie isolée de la VT sont exposées.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: La surcharge de pression ventriculaire augmente à l’exercice chez les patients avec une sténose de valve aortique (SVA). Lorsqu’il n’y a aucun symptôme apparent, il est cependant difficile d’indiquer l’intervention chirurgicale en utilisant seulement les indices de surcharge de pression ventriculaire. D’autres paramètres, tels que la dispersion de la repolarisation ventriculaire (d-QT), qui augmentent avec le gradient de pression transvalvulaire (GPT), n’ont pas été étudiés dans la SVA. L’objectif de l’étude était de déterminer le modèle de réponse du segment QT et de la d-QT à l’épreuve d’effort chez des enfants avec une SVA congénitale modérée afin d’évaluer l’impact de la surcharge de pression ventriculaire selon une perspective électrophysiologique. Matériel et méthodes: 15 patients SVA modérés ont été comparés à 15 sujets contrôles appariés pour l’âge (14.8±2.5 ans vs. 14.2±1.5 ans) et pour le sexe (66,7% de sujets mâles). Tous les sujets ont fait une épreuve d’effort avec enregistrement électrocardiographique à 12 dérivations. Le segment QT a été mesuré à partir du début du complexe QRS jusqu’à l’apex de l’onde T (QTa) au repos, à l’effort maximal ainsi qu’après 1 et 3 minutes de récupération. La longueur du segment QT a été corrigée selon l’équation de Fridericia et la d-QT a été calculée. Résultats: La longueur du segment QT corrigée (QTc) était similaire au repos entre les groupes d’étude, mais était significativement élevée chez les SVA en comparaison avec le groupe contrôle à l’effort maximal (p=0.004) ainsi qu’après 1 (p<0.001) et 3 (p<0.001) minutes de récupération. Une interaction significative a été identifiée entre les groupes pour la d-QT (p=0.034) et les tests post hoc ont révélé une différence significative seulement au repos (p=0.001). Conclusions: Les anomalies de repolarisation ventriculaire peuvent être révélées par l’évaluation de la repolarisation électrique lors de l’épreuve d’effort chez les SVA modérées asymptomatiques. L’utilisation de la réponse du QT à l’effort pourrait être bénéfique pour l’optimisation de la stratification du risque chez ces patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: L’utilisation clinique de biomarqueurs pour prédire la progression de la sténose valvulaire aortique (SVA) n’est pas encore validée à ce jour. Nous voulons évaluer des prédicteurs de la progression de la SVA d’étiologie dégénérative sur la valve aortique tricuspide. Méthodes: Nous avons identifié 126 cas avec SVA et ≥ 2 échocardiogrammes post-recrutement et 126 témoins appariés recrutés par la Biobanque de l’Institut de Cardiologie de Montréal. Nous avons collecté des données cliniques, échocardiographiques et génétiques de base et nous avons mesuré des biomarqueurs plasmatiques. L’évolution de la SVA a été établie par l’analyse des échocardiogrammes sériés et définie comme la variation moyenne par an des paramètres suivants: vitesse transvalvulaire aortique maximale, gradient transvalvulaire aortique moyen (GTAM), aire valvulaire aortique et aire valvulaire aortique indexée. Nous avons évalué l’association des données cliniques/échocardiographiques/génétiques (polymorphisme LPA rs10455872) avec la progression de la SVA et des biomarqueurs plasmatiques avec la présence et la progression de la SVA. Résultats: La durée moyenne de suivi a été de 2,4 ans. Selon des analyses multivariées concernant les données cliniques/échocardiographiques/LPA rs10455872, une fréquence cardiaque plus élevée (pour les patients plus agés et les hommes), le diabète (pour les hommes), et un plus grand GTAM au premier échocardiogramme sont associés à une évolution plus rapide de la SVA. La présence de régurgitation aortique au premier échocardiogramme est associée à une évolution plus lente de la SVA. L’analyse des biomarqueurs plasmatiques versus la présence et la progression de la SVA est en cours. Conclusion: Nos résultats indiquent que une fréquence cardiaque plus élevée, le diabète, et un plus grand GTAM au premier échocardiogramme sont associés avec une progression plus rapide de la SVA. Les résultats de cette étude pourraient contribuer à une approche plus personnalisée du suivi et du traitement de la SVA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La sténose valvulaire aortique (SVA) est la maladie des valves cardiaques la plus répandue dans les pays développés qui touche les personnes âgées. La SVA est un processus actif caractérisé par des dépôts de lipides, de l’inflammation, de la fibrose et une calcification active des feuillets qui progresse vers un épaississement et durcissement de la valve aortique et une diminution de l’aire de la valve aortique. Nous avons émis l’hypothèse que la pathogénèse de la SVA modifie progressivement l’endothélium de la valve aortique, ce qui engendre l’expression de biomarqueurs spécifiques aux tissus et à la maladie. On rapporte dans cet étude, l’utilisation de la technique de sélection in vivo par phage display d’une librairie de peptides aléatoires afin de trouver de nouveaux peptides candidats qui se lieraient à des biomarqueurs spécifiques à la valve aortique malade d’une souris. Des souris ATX (LDLr-/-;Tg(hApoB+/+)) âgées atteintes de la SVA ont été utilisées pour la sélection in vivo d’une librairie de peptides aléatoires de 7 acides aminés contraints ou linéaires. Après 4 tours de criblage, on a caractérisé 14 phages différents qui ont été séparés en 5 motifs consensus pour la librairie linéaire et 11 phages différents qui représentent 5 différents motifs consensus pour la libraire de peptides contraints. La spécificité de 4 phages candidats de la librairie linéaire et de 5 phages de la librairie contrainte a été étudiée par l’immunomarquage des peptides d’intérêt exprimés par les phages sur les coupes de tissus de la valve aortique malade par rapport aux tissus contrôles du foie, du rein, de la rate, du ventricule et du poumon. Parmi eux, 6 phages représentent des peptides candidats intéressants qui ont besoin d’être testés davantage pour évaluer leur spécificité in vivo à la valve. Bien qu’il reste encore de la validation à effectuer, les peptides candidats spécifiques trouvés peuvent représenter des agents moléculaires d’imagerie utiles ou des transporteurs dans la livraison de drogue qui ciblent la valve aortique malade.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rotary valve is a widely used mechanical device in many solids-handling industrial processes. However, it may also be responsible for most of the attrition effects occurring in a typical process. In this study, the attrition effects occurring in a rotary valve operating as a stand-alone device and as part of a pneumatic conveying system were investigated. In the former case granular attrition was carried out at three different rotary valve speeds and the experimental results obtained were found to be in good agreement with the Gwyn correlation. In the latter case three typical air flow rates were used in the pneumatic conveying system. The size distribution of the attrition product obtained at the lowest air flow rate used was not adequately described by the Gwyn correlation. The attrition process and mechanisms involved were analysed and the minimum size of the attrition product obtained from both modes of operations was found to be similar.