965 resultados para drainage water treatment
Resumo:
In order to enable the reuse of the large surplus volume of petroleum produced water for irrigation of crops inedible, the quality evaluation of this water is very important. This work aimed to evaluate the effectiveness of the diffusive gradient in thin films technique (DGT) for the determination of labile Cu (II), Mn (II) and Zn (II) in petroleum produced water destined to reuse in agriculture. Samples were collected at the exit of the wastewater treatment plant (WWTP) (after separation oil/water and flotation) of a Petrobrás onshore production region. Basically, the laboratory experiments with DGT devices involved the evaluation of the behavior of the main variables of the technique for determination of analytes in the samples (diffusion coefficients, immersion time, fractionation of organic and inorganic species, and performance of diffusion gels with different porosities, among others). Also, experiments were conducted based on the solid phase extraction (SPE) protocol with Chelex- 100 resin using previously established protocols to support the study. During the project the possibility of in situ immersions in water treatment plants was evaluated. The DGT technique presented satisfactory results for determination of Mn in produced water, and can be used for in situ determinations. However, the results obtained for Cu and Zn show the need of additional studies
Resumo:
The slugde from decanters in Water Treatment Plants (WTP) has different composition varying, according to the region, coagulant type and dosages, the plant layout. In this work, the physical characterization of the sludge generated from decenties (ETAII the municipality of Rio Claro, Brazil), the manufacture of bodies of evidence-sludge mixture of clay (with humidity of 8% and concentrations of sludge, 5, 15 and 30%) the testing technology after burning the mixture to a temperature of 950 ° C were investigated. The main aim assess the possibility of its use as raw material in the ceramic red production. For comparison of the obtained results it was used values of the testing technology of bodies of evidence only with clay, prepared under the same conditions. In general, the addition of sludge from ETA made worse the properties of the ceramic body, however, the values obtained from the tests on the concentration of 5% of sludge, still remain within the acceptable limits for the production of red pottery pieces.
Resumo:
This paper aimed to study the treatability of rainwater collected in Rio Claro, SP, using natural coagulant tannin based. The tannin was compared with other too primary coagulants, namely ferric chloride and corn starch. Assays were performed in laboratory scale using equipment known as Jarteste and aimed to study the conditions most suitable dosage and coagulation pH. First tests were conducted to compare the coagulating and determination of the conditions to be used in the following tests, taking as a criterion the greatest efficiency for water treatment. Also performed were performed tests to construct the tannin coagulation diagram, using the optimal concentration found in the previous phase, by varying the dosage of coagulant and the pH of clotting in order to determine the isoefficiency regions for apparent color and turbidity. Finally, tests were performed cyclically filtration with filter paper. Preliminary tests indicated that the vegetable tannin concentration 3% (m/m) from the commercial solution was presented the best set of results (84.3% removal of apparent color and 82.51% removal of turbidity) compared to ferric chloride (66.25% removal efficiency and apparent color of turbidity 67.82%) and starch (73.68% removal efficiency apparent color and turbidity to 67.19%). The coagulation diagrams indicate that the best region to work with vegetable tannin 3% is where the coagulant dosage ranges from 15 mg/L to about 37.5 mg/L and coagulation pH ranging from about 6.5 to 7.5. The cyclic filtration showed to be not efficient for the best dosage of coagulant, due to the process of clogging of the filter paper, but proved to be efficient for other dosages. Thus, for the waters studied, the results indicate that the natural coagulant based tannin is an alternative to conventional coagulants, possessing benefits of technical and environmental
Resumo:
The studies of this work aimed to determine the labile fractions of manganese (Mn) in natural and drainage water samples collected around the Osamu Utsumi uranium mine, located in the municipality of Caldas, south-central region of Poços de Caldas- MG, using the technique of diffusion gradient in thin films (DGT). The DGT devices were mounted with Chelex-100 resin, polyacrylamide-agarose hydrogel (conventional porosity) and cellulose acetate membrane. The device were deployed up to 48 hours in six water samples collected from different areas around the uranium mine (075, 076, 022-E, 025-E, 014, and 041). The DGT devices immersed in each sample were gradually removed after 4, 8, 12, 24 and 48 hours. The pH of the samples ranged from 3.0 to 10.5, which influenced the lability and the sampling of the analyte by the Chelex-100 resin. The results showed a linear relationship between accumulated mass and sampling time (immersion curve) for samples 014 and 025-E (pH between 6 and 8) suggesting the ability of the DGT technique for sampling the analyte. The results obtained for samples 075 and 076 (pH<5) and samples 041 and 022-E (pH around 10) were characterized by nonlinear relationships. The values obtained by DGT were compared with Solid Phase Extraction (SPE) technique using Chelex-100. For samples 014 and 025-E, there was a good agreement between the results obtained by both techniques
Resumo:
Currently exists a growing concern for the preservation of the environment Around the world, the environmental awareness in Brazil has strengthened during the past two decades. This concern in Brazil arises from the creation of mechanisms of supervision and punishment on the part of the environmental agencies. In order to meet the pertinent legislation many public and private companies have performed dehydration of waste generated in the process of treatment of industrial effluents, waste water and water treatment in order to reduce transport and disposal costs. The use of geotextile tubes has proven technically and economically feasible to be applied in various situations from water treatment to mining tailings. This work presents the solution adopted for an environmental liability in water treatment plant through the use of geotextile tubes to reduce the water content of the disposal. We evaluated the size distribution curves, Atterberg limits, and chemical composition of the residue. Found high concentrations of aluminum in the waste which would characterize environmental pollution if disposed off directly in nature with no treatment
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Educação - FFC
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
Pós-graduação em Química - IQ
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Maintaining the levels of fluoride ion in public water supply within the parameters of adequacy it becomes essential so the measure carries a greater impact on caries prevention and control, without increasing the prevalence of dental fluorosis. Thus, it is necessary a rigorous control of the process, avoiding the undesired effects at levels above recommended levels, as well as avoiding levels below the recommended that do not offer the highest benefit. The aim of this study was to analyze the content of fluoride in public water supply in the city of Birigui, SP, with different sources of supply, checking if the fluoride levels are within the recommended. The samples were collected monthly from points previously established, with the knowledge of the distribution network of water and identifying the amount and location of supply sources and water treatment plant. Analyses were performed in duplicate in the period from January to December of 2009, in the laboratory - NEPESCO - of the Dental School of Araçatuba, Univ Estadual Paulista – UNESP, using an ion analyzer coupled to a specific electrode for fluoride. Of the total samples (n = 512), 44% (n = 224) had adequate levels and 56% (n = 288) inadequate levels, 10% (n = 49) lower levels and 46% (n = 239) showed levels above the recommended. There were differences in results when comparing the analysis of different sources. The fluoride concentration in the majority of the samples from deep wells was classified as inadequate not offering the desired benefit, or exposing the population to the risk of dental fluorosis.