989 resultados para Sunday school buildings.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Epidemiological studies have shown an elevation in the incidence of asthma, allergic symptoms and respiratory infections among people living or working in buildings with moisture and mould problems. Microbial growth is suspected to have a key role, since the severity of microbial contamination and symptoms show a positive correlation, while the removal of contaminated materials relieves the symptoms. However, the cause-and-effect relationship has not been well established and knowledge of the causative agents is incomplete. The present consensus of indoor microbes relies on culture-based methods. Microbial cultivation and identification is known to provide qualitatively and quantitatively biased results, which is suspected to be one of the reasons behind the often inconsistent findings between objectively measured microbiological attributes and health. In the present study the indoor microbial communities were assessed using culture-independent, DNA based methods. Fungal and bacterial diversity was determined by amplifying and sequencing the nucITS- and16S-gene regions, correspondingly. In addition, the cell equivalent numbers of 69 mould species or groups were determined by quantitative PCR (qPCR). The results from molecular analyses were compared with results obtained using traditional plate cultivation for fungi. Using DNA-based tools, the indoor microbial diversity was found to be consistently higher and taxonomically wider than viable diversity. The dominant sequence types of fungi, and also of bacteria were mainly affiliated with well-known microbial species. However, in each building they were accompanied by various rare, uncultivable and unknown species. In both moisture-damaged and undamaged buildings the dominant fungal sequence phylotypes were affiliated with the classes Dothideomycetes (mould-like filamentous ascomycetes); Agaricomycetes (mushroom- and polypore-like filamentous basidiomycetes); Urediniomycetes (rust-like basidiomycetes); Tremellomycetes and the family Malasseziales (both yeast-like basidiomycetes). The most probable source for the majority of fungal types was the outdoor environment. In contrast, the dominant bacterial phylotypes in both damaged and undamaged buildings were affiliated with human-associated members within the phyla Actinobacteria and Firmicutes. Indications of elevated fungal diversity within potentially moisture-damage-associated fungal groups were recorded in two of the damaged buildings, while one of the buildings was characterized by an abundance of members of the Penicillium chrysogenum and P. commune species complexes. However, due to the small sample number and strong normal variation firm conclusions concerning the effect of moisture damage on the species diversity could not be made. The fungal communities in dust samples showed seasonal variation, which reflected the seasonal fluctuation of outdoor fungi. Seasonal variation of bacterial communities was less clear but to some extent attributable to the outdoor sources as well. The comparison of methods showed that clone library sequencing was a feasible method for describing the total microbial diversity, indicated a moderate quantitative correlation between sequencing and qPCR results and confirmed that culture based methods give both a qualitative and quantitative underestimate of microbial diversity in the indoor environment. However, certain important indoor fungi such as Penicillium spp. were clearly underrepresented in the sequence material, probably due to their physiological and genetic properties. Species specific qPCR was a more efficient and sensitive method for detecting and quantitating individual species than sequencing, but in order to exploit the full advantage of the method in building investigations more information is needed about the microbial species growing on damaged materials. In the present study, a new method was also developed for enhanced screening of the marker gene clone libraries. The suitability of the screening method to different kinds of microbial environments including biowaste compost material and indoor settled dusts was evaluated. The usability was found to be restricted to environments that support the growth and subsequent dominance of a small number microbial species, such as compost material.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Computer equipment, once viewed as leading edge, is quickly condemned as obsolete and banished to basement store rooms or rubbish bins. The magpie instincts of some of the academics and technicians at the University of Greenwich, London, preserved some such relics in cluttered offices and garages to the dismay of colleagues and partners. When the University moved into its new campus in the historic buildings of the Old Royal Naval College in the center of Greenwich, corridor space in King William Court provided an opportunity to display some of this equipment so that students could see these objects and gain a more vivid appreciation of their subject's history.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article examines operational Private Finance Initiative (PFI) school projects and reports the experiences of UK headteachers. It considers the impact of project size on value for money (VFM). Headteachers involved in small projects are more satisfied with costs than those involved in large projects, but headteachers involved in larger projects are more satisfied with affordability. Generally, heads are more satisfied with the buildings than with the services. The authors question the government’s recent policy changes to increase the size of PFI projects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is concerned with assessing the building’s the energy efficiency and qualities of a modular design for the education industry, in order assess the long economic benefits. The research includes a life-cycle energy and cost analysis of the school building design, predicting the impact on the operational cost of the building as a result of the addition of photovoltaic panels. The paper also includes a comparative study between the ECO Modular Solutions building, and a current standard prefabricated school building, quantifying the savings in CO2 emissions and savings in cost.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Public health risk communication during emergencies should be rapid and accurate in order to allow the audience to take steps to prevent adverse outcomes. Delays to official communications may cause unnecessary anxiety due to uncertainty or inaccurate information circulating within the at-risk group. Modern electronic communications present opportunities for rapid, targeted public health risk communication. We present a case report of a cluster of invasive meningococcal disease in a primary school in which we used the school's mass short message service (SMS) text message system to inform parents and guardians of pupils about the incident, to tell them that chemoprophylaxis would be offered to all pupils and staff, and to advise them when to attend the school to obtain further information and antibiotics. Following notification to public health on a Saturday, an incident team met on Sunday, sent the SMS messages that afternoon, and administered chemoprophyaxis to 93% of 404 pupils on Monday. The use of mass SMS messages enabled rapid communication from an official source and greatly aided the public health response to the cluster.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Orange Union High School in Orange, California, ca. 1915. Elongated postcard image shows bird's-eye view looking southeast toward the campus. The original academic building in the center was designed by local architect C.B. Bradshaw and completed in July 1905 [now Wilkinson Hall]. The "Twins," identical buildings officially known as the Science and Commercial Buildings[now Reeves Hall and Smith Hall], flank the academic building on the north and south, forming a "U." They were added in 1913 and designed by Santa Ana architect Fred Eley. The 300 block of North Glassell Street runs in front of the buildings and East Palm Avenue is on the south side. Residences can be seen in front and behind the campus. The campus was purchased by Chapman College in 1954.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Orange Union High School in Orange, California, ca. 1915. Elongated postcard image shows bird's-eye view looking southeast toward the campus. The original academic building in the center was designed by local architect C.B. Bradshaw and completed in July 1905 [now Wilkinson Hall]. The "Twins," identical buildings officially known as the Science and Commercial Buildings[now Reeves Hall and Smith Hall], flank the academic building on the north and south, forming a "U." They were added in 1913 and designed by Santa Ana architect Fred Eley. The 300 block of North Glassell Street runs in front of the buildings and East Palm Avenue is on the south side. Residences can be seen in front and behind the campus. The campus was purchased in 1954 by Chapman College.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Orange Union High School, located at 333 N. Glassell Street, Orange, California, 1905. Constructed in 1905 and designed by local architect, C.B. Bradshaw, image shows main building, now called Wilkinson Hall, which moved north prior to 1921. Acquired in 1954 and currently operated by Chapman University; it was renamed Wilkinson Hall in honor of J. E. Wilkinson, a former trustee, chairman of the board, and acting president. View shows front and south elevations across North Glassell Street.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The United Kingdom is committed to a raft of requirements to create a low-carbon economy. Buildings consume approximately 40% of UK energy demand. Any improvement on the energy performance of buildings therefore can significantly contribute to the delivery of a low-carbon economy. The challenge for the construction sector and its clients is how to meet the policy requirements to deliver low and zero carbon (LZC) buildings, which spans broader than the individual building level, to requirements at the local and regional levels, and wider sustainability pressures. Further, the construction sector is reporting skills shortages coupled with the need for ‘new skills’ for the delivery of LZC buildings. The aim of this paper is to identify, and better understand, the skills required by the construction sector and its clients for the delivery of LZC buildings within a region. The theoretical framing for this research is regional innovation system (RIS) using a socio-technical network analysis (STNA) methodology. A case study of a local authority region is presented. Data is drawn from a review of relevant local authority documentation, observations and semi-structured interviews from one (project 1) of five school retrofit projects within the region. The initial findings highlight the complexity surrounding the form and operation of the LZC network for project 1. The skills required by the construction sector and its clients are connected to different actor roles surrounding the delivery of the project. The key actors involved and their required skills are: project management and energy management skills required by local authority; project management skills (in particular project planning), communication and research skills required by school end-users; and a ‘technical skill’ relating to knowledge of a particular energy efficient measure (EEM) and use of equipment to implement the EEM is required by the EEM contractors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Demand for good indoor air quality is increasing as people recorgnise the risks to their health and productivity from indoor pollutants. There is a tendency to reduce ventilation rates to ensure energy conservation in buildings; in this instance schools. However, evidence reviewed shows that this can be detrimental to health and wellbeing in schools because of the learner density within a small area (1.8 - 2.4m2/person); eventually indicating that carbon dioxide (CO2) levels can rise to very high levels in classroom occupancy periods. A preliminary study to investigate the impact of indoor environmental parameters has been performed in a secondary school classroom in Pretoria, South Africa. Factors monitored include temperature, relative humidity, lighting, air velocities and CO2 concentrations. From the results low air velocities are recorded (i.e. 0.1-0.3m/s) impacting on the retention of CO2 build-up in the classroom. Results presented in this paper are the initial findings of ongoing research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Actor Network Theory (ANT) is explored as a useful tool in researching the intersection of English teaching and Information Communication Technologies (ICTs), to understand the complex interaction of influences, both human and non-human, that combine to achieve a particular outcome, in this case the uptake of ICTs by English teachers in an Australian school. What this means is that alongside interviewing the teachers, administrators and technical support people, recognition is given to the influence of inanimate objects such as computers, bluestone walls and curriculum documents. This constructs a more complex picture of the change process accounting both for the invisible ideology of teacher beliefs as well as the technical capacity and incapacity of machines, buildings and policies. At the heart of ANT lies the metaphor of the heterogeneous network which is made up of diverse, not simply human, materials. Often these networks become consolidated as single point actors e.g. the English curriculum, the computer laboratory, the library, which are then seen as fixed entities rather than an amalgamation of parts prone to change. ANT allows for the constituent parts to be investigated, and following Bruno Latour's Aramis, (1996) this can be done creatively by literally giving voice to inanimate objects such as computers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Buildings have a significant impact on the environment due to the energy required for the manufacture of construction materials. The method of assessing the energy embodied in a product is known as energy analysis. Detailed office building embodied energy case studies are very rare. However, there is evidence to suggest that the energy requirements for the construction phase of commercial buildings, including the energy embodied in materials, is a significant component of the life cycle energy requirements. This thesis sets out to examine the current state of energy analysis, determine the national average energy intensities < i.e. embodied energy rates < for building materials and assess the significance of using national average energy intensities for the energy analysis of a case study office building. Likely ranges of variation in the building material embodied energy rates from the national averages are estimated and the resulting distribution for total embodied energy in the case study building simulated. Strategies for improving the energy analysis methods and data are suggested. Detailed energy analysis is shown to be a useful indicative method of quantifying the energy required for the construction of buildings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis demonstrates a strong relationship between life cycle energy and life cycle cost based on an analysis of thirty recent Melbourne buildings. Embodied energy (initial cost) can be reliably modelled by construction cost (initial cost) and thus be readily available as early design advice, enabling more sustainable development.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Initial findings indicated that the curved relationships of height-cost of residential buildings in Shanghai and Hong Kong exhibit different profiles. The differences suggest that, Hong Kong contractors have more expertise in multi-story and high-rise construction than contractors in Shanghai. The dissimilarities also imply that different sets of criteria should be applied in the judgement of height affects on cost in different locations.