991 resultados para Satisfaction measurement,


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new respiratory impedance estimator to minimize the error due to breathing. Its practical reliability was evaluated in a simulation using realistic signals. These signals were generated by superposing pressure and flow records obtained in two conditions: 1) when applying forced oscillation to a resistance- inertance- elastance (RIE) mechanical model; 2) when healthy subjects breathed through the unexcited forced oscillation generator. Impedances computed (4-32 Hz) from the simulated signals with the new estimator resulted in a mean value which was scarcely biased by the added breathing (errors less than 1 percent in the mean R, I , and E ) and had a small variability (coefficients of variation of R, I, and E of 1.3, 3.5, and 9.6 percent, respectively). Our results suggest that the proposed estimator reduces the error in measurement of respiratory impedance without appreciable extracomputational cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT. A dual-wavelength digital holographic microscope to measure absolute volume of living cells is proposed. The optical setup allows us to reconstruct two quantitative phase contrast images at two different wavelengths from a single hologram acquisition. When adding the absorbing dye fast green FCF as a dispersive agent to the extracellular medium, cellular thickness can be univocally determined in the full field of view. In addition to the absolute cell volume, the method can be applied to derive important biophysical parameters of living cells including osmotic membrane water permeability coefficient and the integral intracellular refractive index (RI). Further, the RI of transmembrane flux can be determined giving an indication about the nature of transported solutes. The proposed method is applied to cultured human embryonic kidney cells, Chinese hamster ovary cells, human red blood cells, mouse cortical astrocytes, and neurons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The estimation of blood pressure is dependent on the accuracy of the measurement devices. We compared blood pressure readings obtained with an automated oscillometric arm-cuff device and with an automated oscillometric wrist-cuff device and then assessed the prevalence of defined blood pressure categories. METHODS: Within a population-based survey in Dar es Salaam (Tanzania), we selected all participants with a blood pressure >/= 160/95 mmHg (n=653) and a random sample of participants with blood pressure <160/95 mmHg (n=662), based on the first blood pressure reading. Blood pressure was reassessed 2 years later for 464 and 410 of the participants, respectively. In these 874 subjects, we compared the prevalence of blood pressure categories as estimated with each device. RESULTS: Overall, the wrist device gave higher blood pressure readings than the arm device (difference in systolic/diastolic blood pressure: 6.3 +/- 17.3/3.7 +/- 11.8 mmHg, P<0.001). However, the arm device tended to give lower readings than the wrist device for high blood pressure values. The prevalence of blood pressure categories differed substantially depending on which device was used, 29% and 14% for blood pressure <120/80 mmHg (arm device versus wrist device, respectively), 30% and 33% for blood pressure 120-139/80-89 mmHg, 17% and 26% for blood pressure 140-159/90-99 mmHg, 12% and 13% for blood pressure 160-179/100-109 mmHg and 13% and 14% for blood pressure >/= 180/110 mmHg. CONCLUSIONS: A large discrepancy in the estimated prevalence of blood pressure categories was observed using two different automatic measurement devices. This emphasizes that prevalence estimates based on automatic devices should be considered with caution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: en oncologie apparaissent sur le marché depuis quelques années de nouveaux traitements en formulation orale facilitant l'administration et améliorant la qualité de vie du patient mais augmentant le risque de non adhésion et d'erreurs de posologie. L'observation par MEMS® (Medication Event Monitoring System) permet le suivi et l'encadrement du traitement oral et par le biais d'entretiens semi structurés menés par le pharmacien, ouvre la discussion sur les problèmes révélés par cette prise en charge. Méthode: étude non randomisée prospective uni centrique regroupant 50 patients inclus dans 3 groupes de traitements oncologiques oraux courants (capecitabine, letrozole/exemestane, imatinib/sunitinib) bénéficiant d'un suivi oncologique classique et équipés d'un MEMS® pour un an maximum. La persistance et la qualité d'exécution sont les deux paramètres mesurés grâce aux données récoltées électroniquement. Les entretiens sont dédiés à la prévention de la non adhésion et à la gestion des effets secondaires médicamenteux. La satisfaction est évaluée par un questionnaire à la fin du suivi. Résultats: à ce jour 38 patients ont été inclus dans l'étude. Les données complètes sont disponibles pour les 19 premiers patients dont 10 sous capecitabine et 9 sous letrozole/exemestane. Dans ce collectif l'âge médian est de 66 ans avec une majorité de femmes (11:8). La persistance à 10 jours est de 85% et la qualité d'exécution de 99%. Les toxicités observées supérieures à grade 1 sont 1 syndrome mains-pieds (G3) et 1 syndrome coronarien aigu (G3). Le questionnaire de fin de suivi relève une satisfaction de 85% des patients pour les entretiens proposés (57% utiles, 28% très utiles, 15% inutiles) et le succès quant à l'intégration du MEMS® dans leur quotidien (57% très facile, 43% facile). Conclusion: la persistance et la qualité d'exécution observées dans notre collectif sont excellentes. La satisfaction retrouvée auprès des patients reflète le besoin d'un soutien complémentaire face à la complexité de la maladie oncologique. La gestion pluridisciplinaire profite tant aux patients qu'au binôme médecin-pharmacien par l'amélioration de la communication globale entre les divers acteurs et par l'identification précoce des risques de non adhésion. La poursuite de cette étude et l'analyse des futures données permettra de mesurer le réel impact de notre intervention et de justifier le bénéfice pour des patients sous traitement similaire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The advances of the semiconductor industry enable microelectromechanical systems sensors, signal conditioning logic and network access to be integrated into a smart sensor node. In this framework, a mixed-mode interface circuit for monolithically integrated gas sensor arrays was developed with high-level design techniques. This interface system includes analog electronics for inspection of up to four sensor arrays and digital logic for smart control and data communication. Although different design methodologies were used in the conception of the complete circuit, high-level synthesis tools and methodologies were crucial in speeding up the whole design cycle, enhancing reusability for future applications and producing a flexible and robust component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new approach to the local measurement of residual stress in microstructures is described in this paper. The presented technique takes advantage of the combined milling-imaging features of a focused ion beam (FIB) equipment to scale down the widely known hole drilling method. This method consists of drilling a small hole in a solid with inherent residual stresses and measuring the strains/displacements caused by the local stress release, that takes place around the hole. In the presented case, the displacements caused by the milling are determined by applying digital image correlation (DIC) techniques to high resolution micrographs taken before and after the milling process. The residual stress value is then obtained by fitting the measured displacements to the analytical solution of the displacement fields. The feasibility of this approach has been demonstrated on a micromachined silicon nitride membrane showing that this method has high potential for applications in the field of mechanical characterization of micro/nanoelectromechanical systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we show that the orthorhombic phase of FeSi2 (stable at room temperature) displays a sizable anisotropy in the infrared spectra, with minor effects in the Raman data too. This fact is not trivial at all, since the crystal structure corresponds to a moderate distortion of the fluorite symmetry. Our analysis is carried out on small single crystals grown by flux transport, through polarization-resolved far-infrared reflectivity and Raman measurements. Their interpretation has been obtained by means of the simulated spectra with tight-binding molecular dynamics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Positional therapy that prevents patients from sleeping supine has been used for many years to manage positional obstructive sleep apnea (OSA). However, patients' usage at home and the long term efficacy of this therapy have never been objectively assessed.¦METHODS: Sixteen patients with positional OSA who refused or could not tolerate continuous positive airway pressure (CPAP) were enrolled after a test night study (T0) to test the efficacy of the positional therapy device. The patients who had a successful test night were instructed to use the device every night for three months. Nightly usage was monitored by an actigraphic recorder placed inside the positional device. A follow-up night study (T3) was performed after three months of positional therapy.¦RESULTS: Patients used the device on average 73.7 ± 29.3% (mean ± SD) of the nights for 8.0 ± 2.0 h/night. 10/16 patients used the device more than 80% of the nights. Compared to the baseline (diagnostic) night, mean apnea-hypopnea index (AHI) decreased from 26.7 ± 17.5 to 6.0 ± 3.4 with the positional device (p<0.0001) during T0 night. Oxygen desaturation (3%) index also fell from 18.4 ± 11.1 to 7.1 ± 5.7 (p = 0.001). Time spent supine fell from 42.8 ± 26.2% to 5.8 ± 7.2% (p < 0.0001). At three months (T3), the benefits persisted with no difference in AHI (p = 0.58) or in time spent supine (p = 0.98) compared to T0 night. The Epworth sleepiness scale showed a significant decrease from 9.4 ± 4.5 to 6.6 ± 4.7 (p = 0.02) after three months.¦CONCLUSIONS: Selected patients with positional OSA can be effectively treated by a positional therapy with an objective compliance of 73.7% of the nights and a persistent efficacy after three months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paracaspase MALT1 is a Cys-dependent, Arg-specific protease that plays an essential role in the activation and proliferation of lymphocytes during the immune response. Oncogenic activation of MALT1 is associated with the development of specific forms of B-cell lymphomas. Through specific cleavage of its substrates, MALT1 controls various aspects of lymphocyte activation, including the activation of transcriptional pathways, the stabilization of mRNAs, and an increase in cellular adhesion. In lymphocytes, the activity of MALT1 is tightly controlled by its inducible monoubiquitination, which promotes the dimerization of MALT1. Here, we describe both in vitro and in vivo assays that have been developed to assess MALT1 activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of pavement roughness has been the concern of highway engineers for more than 70 years. This roughness is referred to as "riding quality" by the traveling public. Pavement roughness evaluating devices have attempted to place either a graphical or numerical value on the public's riding comfort or discomfort. Early graphical roughness recorders had many different designs. In 1900 an instrument called the "Viagraph" was developed by an Irish engineer.' The "Viagraph" consisted of a twelve foot board with graphical recorder drawn over the pavement. The "Profilometer" built in Illinois in 1922 was much more impressive. ' The instrument's recorder was mounted on a frame supported by 32 bicycle wheels mounted in tandem. Many other variations of profilometers with recorders were built but most were difficult to handle and could not secure uniformly reproducible results. The Bureau of Public Roads (BPR) Road Roughness Indicator b u i l t in 1941 is the most widely used numerical roughness recorder.' The BPR Road Roughness Indicator consists of a trailer unit with carefully selected springs, means of dampening, and balanced wheel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is common knowledge that patients' satisfaction influences their compliance with the proposed treatment and their future use of health services, and that the therapeutic alliance represents a recognised factor in the success of psychotherapeutic management. In May and June 2011 we conducted an enquiry in all the paedopsychiatric outpatient units of the Canton of Vaud in Switzerland, from which we gathered 1261 questionnaires from consulting children and their parents. The questions covered inter alia overall satisfaction concerning the quality of the care on off er, perception of the therapeutie alliance and the helpfulness of the varions types of treatment. The instruments used are recognised and validated internationally (HAQII and CSQS). The results reve al a high degree of satisfaction and a good perception of the therapeutic alliance's quality: an average of 4.9 for children and 5.9 for parents concerning the therapeutic alliance, on a scale from 1 (totally disagree) to 6 (totally agree), and concerning patient satisfaction an average of 3.2 for children and 3.4 for parents on a scale of 1 to 4. Regarding perception of the benefit derived from different forms of treatment, individual and family interviews were overwhel~ningly approved (3.2 out of 4), while compliance with drug treatment was less recognised as helpful to children (2.3 out of 4).