936 resultados para Reliability in automation


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Includes bibliography.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Bibliography: leaves 41-43.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to analyze the psychometric properties of the Spanish translation of the List of Social Situation Problems (LSSP; S. H. Spence, 1980). The questionnaire was administered to a sample of 388 adolescents between the ages of 12 and 18. Exploratory factor analysis identified four factors: Social Anxiety, Adult Oppositional, Assertiveness, and Making Friends, which accounted for 26.64% of the variance. Internal consistency of the total scale was high (alpha = .86). Correlations between the LSSP and two self-report measures of social anxiety, the Questionnaire about Interpersonal Difficulties for Adolescents (r = .45) and the Social Phobia and Anxiety Inventory (r = .48), were statistically significant. A significant difference was found between LSSP total scores for adolescents with and without social anxiety (d = 1.14), supporting the construct validity of the scale.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Most of the modem developments with classification trees are aimed at improving their predictive capacity. This article considers a curiously neglected aspect of classification trees, namely the reliability of predictions that come from a given classification tree. In the sense that a node of a tree represents a point in the predictor space in the limit, the aim of this article is the development of localized assessment of the reliability of prediction rules. A classification tree may be used either to provide a probability forecast, where for each node the membership probabilities for each class constitutes the prediction, or a true classification where each new observation is predictively assigned to a unique class. Correspondingly, two types of reliability measure will be derived-namely, prediction reliability and classification reliability. We use bootstrapping methods as the main tool to construct these measures. We also provide a suite of graphical displays by which they may be easily appreciated. In addition to providing some estimate of the reliability of specific forecasts of each type, these measures can also be used to guide future data collection to improve the effectiveness of the tree model. The motivating example we give has a binary response, namely the presence or absence of a species of Eucalypt, Eucalyptus cloeziana, at a given sampling location in response to a suite of environmental covariates, (although the methods are not restricted to binary response data).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective. To assess the reliability of physical examination of the osteoarthritic (OA) knee by rheumatologists, and to evaluate the benefits of standardization. Methods. Forty-two physical signs and techniques were evaluated using a 6 X 6 Latin square design. Patients with mild to severe knee OA, based on physical and radiographic signs, were examined in random order prior to and following standardization of techniques. For those signs with dichotomous scales, agreement among the rheumatologists was calculated as the prevalence-adjusted bias-adjusted kappa (PABAK), while for the signs with continuous and ordinal scales, a reliability coefficient (R-c) was calculated using analysis of variance. A PABAK of >0.60 and an Re of >0.80 were considered to indicate adequate reliability. Results. Adequate poststandardization reliability was achieved for 30 of 42 physical signs/techniques (71%). The most highly reliable signs identified by physical examination of the OA knee included alignment by goniometer (R-c = 0.99), bony swelling (R-c = 0.97), general passive crepitus (R-c = 0.96), gait by inspection (PABAK = 0.78), effusion bulge sign (R-c = 0.97), quadriceps atrophy (R. = 0.97), medial tibiofemoral tenderness (R-c = 0.94), lateral tibiofemoral tenderness (R-c = 0.85), patellofemoral tenderness by grind test (R-c = 0.94), and flexion contracture (R-c = 0.95). The standardization process resulted in substantial improvements in reliability for evaluation of a number of physical signs, although for some signs, minimal or no effect of standardization was noted. After standardization, warmth (PABAK = 0.14), medial instability at 30degrees flexion (PABAK = 0.02), and lateral instability at 30degrees flexion (PABAK = 0.34) were the only 3 signs that were highly unreliable. Conclusion. With the exception of physical examinations for instability, a comprehensive knee examination can be performed with adequate reliability. Standardization further improves the reliability for some physical signs and techniques. The application of these findings to future OA studies will contribute to improved outcome assessments in OA.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Accurate monitoring of prevalence and trends in population levels of physical activity (PA) is a fundamental public health need. Test-retest reliability (repeatability) was assessed in population samples for four self-report PA measures: the Active Australia survey (AA, N=356), the short International Physical Activity Questionnaire (IPAQ, N=104), the physical activity items in the Behavioral Risk Factor Surveillance System (BRFSS, N=127) and in the Australian National Health Survey (NHS, N=122). Percent agreement and Kappa statistics were used to assess reliability of classification of activity status as 'active', 'insufficiently active' or 'sedentary'. Intraclass correlations (ICCs) were used to assess agreement on minutes of activity reported for each item of each survey and for total minutes. Percent agreement scores for activity status were very good on all four instruments, ranging from 60% for the NHS to 79% for the IPAQ. Corresponding Kappa statistics ranged from 0.40 (NHS) to 0.52 (AA). For individual items, ICCs were highest for walking (0.45 to 0.78) and vigorous activity (0.22 to 0.64) and lowest for the moderate questions (0.16 to 0.44). All four measures provide acceptable levels of test-retest reliability for assessing both activity status and sedentariness, and moderate reliability for assessing total minutes of activity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The reliability of measurement refers to unsystematic error in observed responses. Investigations of the prevalence of random error in stated estimates of willingness to pay (WTP) are important to an understanding of why tests of validity in CV can fail. However, published reliability studies have tended to adopt empirical methods that have practical and conceptual limitations when applied to WTP responses. This contention is supported in a review of contingent valuation reliability studies that demonstrate important limitations of existing approaches to WTP reliability. It is argued that empirical assessments of the reliability of contingent values may be better dealt with by using multiple indicators to measure the latent WTP distribution. This latent variable approach is demonstrated with data obtained from a WTP study for stormwater pollution abatement. Attitude variables were employed as a way of assessing the reliability of open-ended WTP (with benchmarked payment cards) for stormwater pollution abatement. The results indicated that participants' decisions to pay were reliably measured, but not the magnitude of the WTP bids. This finding highlights the need to better discern what is actually being measured in VVTP studies, (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Awareness of optimal behaviour states of children with profound intellectual disability has been reported in the literature as a potentially useful tool for planning intervention within this population. Some arguments have been raised, however, which question the reliability and validity of previously published work on behaviour state analysis. This article sheds light on the debate by presenting two stages of a study of behaviour state analysis for eight girls with Rett syndrome. The results support Mudford, Hogg, and Roberts' (1997, 1999) concerns with the pooling of participant data. The results of Stage 2 also suggest, however, that most categories of behaviour state can be reliably distinguished once definitions of behaviours for each state are clearly defined.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We have used an animal model to test the reliability of a new portable continuous-wave Doppler ultrasonic cardiac output monitor, the USCOM. In six anesthetized dogs, cardiac output was measured with a high-precision transit time ultrasonic flowprobe placed on the ascending aorta. The dogs' cardiac output was increased with a dopamine infusion (0-15 mug (.) kg(-1) (.) min(-1)). Simultaneous flowprobe and USCOM cardiac output measurements were made. Up to 64 pairs of readings were collected from each dog. Data were compared by using the Bland and Altman plot method and Lin's concordance correlation coefficient. A total of 319 sets of paired readings were collected. The mean (+/-SD) cardiac output was 2.62 +/- 1.04 L/min, and readings ranged from 0.79 to 5.73 L/min. The mean bias between the 2 sets of readings was -0.01 L/min, with limits of agreement (95% confidence intervals) of -0.34 to 0.31 L/min. This represents a 13% error. In five of six dogs, there was a high degree of concordance, or agreement, between the 2 methods, with coefficients >0.9. The USCOM provided reliable measurements of cardiac output over a wide range of values. Clinical trials are needed to validate the device in humans.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives: The study was designed to show the validity and reliability of scoring the Physical Mobility Scale (PMS). PMS was developed by physiotherapists working in residential aged care to specifically show resident functional mobility and to provide information regarding each resident's need for supervision or assistance from one or two staff members and equipment during position changes, transfers, mobilising and personal care. Methods: Nineteen physiotherapists of varying backgrounds and experience scored the performances of nine residents of care facilities from video recordings. The performances were compared to scores on two 'gold standard' assessment tools. Four of the physiotherapists repeated the evaluations. Results: The PAIS showed excellent content validity and reliability. Conclusions: The PAIS provides graded performance of physical mobility, including level of dependency on staff and equipment. This is a major advantage over existing functional assessment tools. There is no need for specific training for physiotherapists to use the tool.

Relevância:

40.00% 40.00%

Publicador: