962 resultados para Pitot tube
Resumo:
Aeromonas genus is considered an emerging pathogen and its presence in drinking water supplies is a reason to public health concern. This study investigated the occurrence of Aeromonas in samples from collective reservoirs and wells used as drinking water sources in a peri-urban area. A total of 35 water samples were collected from collective reservoirs and 32 from wells bimonthly, from September 2007 to September 2008. Aeromonas spp determination was carried out using a Multiple-Tube Technique. Samples were inoculated into alkaline peptone water and the superficial film formed was transferred to blood agar plates amended with ampicillin. Typical Aeromonas colonies were submitted to a biochemical screening and then to biochemical tests for species differentiation. Aeromonas was detected in 13 (19%) of the 69 samples examined (6 from collective reservoirs and 7 from wells). Concentrations of Aeromonas in collective reservoirs ranged from <0.3 to 1.2 x10²MPN/100mL and, in wells, from <0.3 to 2.4 x10²MPN/100mL. The most frequent specie in the collective reservoir samples was Aeromonas spp (68%), followed by A. encheleia (14%) and A. allosaccharophila (8%) and A. hydrophila (8%). Aeromonas spp (87%) was the most frequent specie isolated from well samples, followed by A. allosacchariphila (8%), A. encheleia (2%) and A. jandaei (5%). These data show the presence and diversity of Aeromonas genus in the samples analyzed and highlight that its presence in drinking water poses a significant public health concern.
Resumo:
O objetivo do estudo foi realizar uma análise embriológica dos roedores histricomorfos (paca, cutia, preá e capivara), a fim de comparar com a de outros roedores e com a morfogênese humana um padrão embriológico. Utilizaram-se 8 espécimes de roedores sendo, 2 embriões para cada espécie coletada, ambas em inicio de gestação. Estes foram retirados dos úteros gestantes através de ovariosalpingohisterectomia parcial, seguido de fixação em solução de paraformaldeído 4%. Para as mensurações de Crow-Rump, adotou-se como referência a crista nucal numa extremidade e da última vértebra sacral na extremidade oposta. De forma geral, os embriões analisados mostraram as seguintes características morfológicas: divisão dos arcos branquiais, o não fechamento do neuróporo cranial em alguns embriões estudados, a curvatura cranial acentuada e os somitos delimitados e individualizados. O broto dos membros apresentava-se em desenvolvimento em formato de remo, além da impressão cardíaca e fígado. Na região caudal, visualizou-se a curvatura crânio-caudal, a vesícula óptica com e sem pigmentação da retina, a abertura do tubo neural na região do quarto ventrículo encefálico, a fosseta nasal e a formação das vesículas encefálicas. Concluímos que desenvolvimento embriológico dos roedores histricomorfos pode ser comparado à morfogênese de ratos, cobaios, coelhos e humanos nos diferentes estágios de desenvolvimento, tomando apenas o cuidado com as particularidades de cada espécie, além da implementação de tecnologias reprodutivas, especialmente a de embriões, a qual requer o conhecimento do desenvolvimento pré-implantação referente às fases de desenvolvimento.
Resumo:
We describe a case of a spontaneously established mixed colony of two species of stingless bees. The host colony of Scaptotrigona depilis, an aggressive bee that forms large colonies, was invaded by workers of Nannotrigona testaceicornis, a smaller bee that forms small colonies. The host colony and the invading species colony were maintained in next boxes about 1.5 m apart. The N. testaceicornis colony had been recently divided. Observations were made daily for 10 min, and every two weeks the colony was opened for observations within the nest. Initially the host colony bees repulsed the invading species, but as their numbers built up, they were no longer able to defend the entrance. An estimated 60-90 N. testaceicornis workers lived integrated into the colony of S. depilis for 58 days. During this period, they reconstructed and maintained the entrance tube, changing it to an entrance typical of N. testaceicornis. They also collected food and building material for the host colony. Nannotrigona testaceicornis tolerated transit of S. depilis through the entrance, but did not allow the host species to remain within the tube, though the attacks never resulted in bee mortality. Aggression was limited to biting the wings; when the bees fell to the ground they immediately separated and flew back. There have been very few reports of spontaneously occurring mixed stingless bee colonies. It is difficult to determine what caused the association that we found; probably workers of N. testaceicornis got lost when we split their colony, and then they invaded the colony of S. depilis.
Resumo:
In this work a simple and reliable method for the simultaneous determination of Cr, Fe, Ni and V in crude oil, using emulsion sampling graphite furnace atomic absorption spectrometry is proposed. Under the best conditions, sample masses around 50 mg were weighed in polypropylene tubes and emulsified in a mixture of 0.5% (v v(-1)) hexane + 6% (m v(-1)) Triton X-100 (R). Considering the compromised conditions, the pyrolysis an atomization temperatures for the simultaneous determination of Cr, Fe, Ni and V were 1400 degrees C and 2500 degrees C, respectively. Aliquots of 20 mu L of reference solution and sample emulsion were co-injected into the graphite tube with 10 mu L of 1.0 g L(-1) Mg(NO(3))(2) as chemical modifier. The detection limits (n = 10, 3 sigma) and characteristic masses were, respectively: 0.07 mu g g(-1) and 19 pg for Cr; 2.15 mu g g(-1) and 31 pg for Fe; 1.25 mu g g(-1) and 44 pg for Ni; and 1.15 mu g g(-1) and 149 pg for V. The reliability of the proposed method was checked by fuel oil Standard Reference Material (SRMTriton X-100 (R) 1634c - NIST) analysis. The concentrations found presented no statistical differences compared to the certified values at 95% confidence level.
Resumo:
Adults of Pseudopolydora rosebelae sp. nov. inhabit silty tubes on muddy bottoms in shallow water in southern Brazil, states of Sao Paulo and Rio de Janeiro. They are rare and extremely delicate, attaining 20 mm long for 55 chaetigers. The worms are distinctive by their colourful yellow and black pigmentation on the anterior part of body and palps, prominent transverse hood on the dorsal anterior edge of chaetiger 3, and lack of coloured respiratory pigment in blood. Of 12 examined individuals, all were females. Oogenesis is intraovarian; oocytes develop from chaetigers 14-15 to chaetigers 24-36. Recently laid oocytes were about 150 mu m in diameter, with embryos and developing larvae found in capsules inside female tubes in March-June. Broods comprised up to 23 capsules with 400 propagules. Capsules were joined to each other in a string and each attached by a single thin stalk to the inner wall of the tube. Larvae hatched at the 4-chaetiger stage and fed on plankton. Pelagic larvae are unique among Pseudopolydora in having large ramified mid-dorsal melanophores from chaetiger 3 onwards. Competent larvae are able to settle and metamorphose at the 15-chaetiger stage, but can remain planktonic up to 18 chaetigers. They have one pair of unpigmented ocelli and three pairs of black eyes in the prostomium, unpaired ramified mid-dorsal melanophores on chaetiger 1 and on the pygidium, ramified lateral melanophores on chaetigers 5-10, prominent yellow chromatophores in the prostomium, peristomium, on dorsal and ventral sides of chaetigers and in the pygidium. Branchiae are present on chaetigers 7-10, and gastrotrochs are arranged on chaetigers 3, 5, 7 and 12. Provisional serrated bristles are present in all notopodia, and hooks are present in neuropodia from chaetiger 8 onwards. Two pairs of provisional protonephridia are present in chaetigers 1 and 2, and adult metanephridia are present from chaetiger 4.
Resumo:
Pomegranate [Punica granatum (Punicaceae)] is characterized by having two types of flowers on the same tree: hermaphroditic bisexual flowers and functionally male flowers. This condition, defined as functional andromonoecy, can result in decreased yields resulting from the inability of male flowers to set fruit. Morphological and histological analyses of bisexual and male flowers were conducted using light and scanning electron microscopy (SEM) to characterize the different flower types observed in pomegranate plants and to better understand their developmental differences. Bisexual flowers had a discoid stigma covered with copious exudate, elongated stigmatic papillae, a single elongate style, and numerous stamens inserted on the inner wall of the calyx tube. Using fluorescence staining, high numbers of pollen tubes were observed growing through a central stylar canal. Ovules were numerous, elliptical, and anatropous. In contrast, male flowers had reduced female parts and exhibited shortened pistils of variable heights. Stigmatic papillae of male flowers had little exudate yet supported pollen germination. However, pollen tubes were rarely observed in styles. Ovules in male flowers were rudimentary and exhibited various stages of degeneration. Pollen from both types of flowers was of similar size, approximate to 20 mu m, and exhibited similar percent germination using in vitro germination assays. Pollen germination was strongly influenced by temperature. Maximal germination (greater than 74%) was obtained at 25 and 35 degrees C; pollen germination was significantly lower at 15 degrees C (58%) and 5 degrees C (10%).
Resumo:
Liquid-liquid microextraction without phase segmentation was implemented in a multicommuted flow system for determination of the anti-hypertensive diltiazem. The procedure was based on ion pair formation between the drug and the dye bromothymol blue at pH 3.5. The detection was performed without phase separation in a glass tube coupled to a fiber-optics spectrophotometer. The total volume of chloroform was reduced to 50 mu L in comparison with 10 mL consumed in batch. A linear response was observed between 9 and 120 mu mol L(-1), with a detection limit of 0.9 mu mol L(-1) (99.7% confidence level). The coefficient of variation (n = 10), sampling rate and extraction efficiency were estimated as 0.6%, 78 determinations per hour and 61%, respectively. About 30 mu g of bromothymol blue was consumed and the waste volume was 380 mu L per determination. The results for pharmaceutical samples agreed with those obtained by the reference procedure at the 95% confidence level. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
A method for simultaneous determination of Cr, Fe, Co, Ni, Cu, Zn, As e Pb in liquid chemical waste using Energy Dispersive X-Ray Fluorescence (EDXRF) technique was evaluated. A small sample amount (200 mu L) was dried on a 6.35 mu m thickness Mylar film at 60 degrees C and the analyses were carried out using an EDXRF spectrometer operated with an X-ray Mo tube (Zr filter) at 30 kV/20 mA. The acquisition time was 300 s and the Ga element was utilized as internal standard at 25 mg/L for quantitative analysis. The method trueness was assessed by spiking and the detection limit for those elements ranged from 0.39 to 1.7 mg/L. This method is notable because it assists the choice of the more appropriated waste treatment procedure, in which inter elemental interference is a matter of importance. In addition, this inexpensive method allows a non-destructive determination of the elements from (19)K to (92)U simultaneously.
Resumo:
Objective: To provide a detailed description of the nasopharyngeal intubation (NPI) technique and photographs, which should be helpful for those who may need to perform it for treating the airway obstruction in Robin sequence. Design: To describe and illustrate the NPI technique and the necessary considerations for its application. Setting: Hospital de Reabilitacao de Anomalias Craniofacial of University of Sao Paulo, Brazil. Result: The NPI procedure involves the use of a whitish, Portex, number 3.0 or 3.5, silicone tube, introduced 8 cm deep into the infant`s nostril and fixed with Micropore tape. The tube is to be removed at least twice a day for proper hygiene (with running water, detergent, and swabs) and should be changed every 7 days. This procedure is taught to the children`s parents or caretakers by the nurse during hospitalization. Conclusion: The technique is so simple that it can be performed by the parents themselves, allowing continuation of the treatment at home.
Resumo:
The discovery of superconductivity at 39 K in MgB(2) has been catching the attention of scientists due to the possibility of applying the material in magnets and electronic devices operating with cryocoolers (temperatures around 20 K). In the present work, a methodology to optimize the critical current densities of this material is described. MgB(2) bulk samples were prepared and analyzed with the addition of other diborides with the same C32 hexagonal structure as MgB(2) (TaB(2), ZrB(2), VB(2), and AlB(2)) and with simultaneous addition of SiC. Microstructural characterization, performed using SEM+EDS and XRD, was extremely important to determine the distribution and compositional characterization of the superconducting phase. Magnetic superconducting characterization using SQUID was performed to determine the best material addition. As a result we could analyze the behavior of each addition on the current transport capacity, including an analysis of the magnetic flux pinning mechanisms.
Resumo:
In the present study, quasi-diabatic two-phase flow pattern visualizations and measurements of elongated bubble velocity, frequency and length were performed. The tests were run for R134a and R245fa evaporating in a stainless steel tube with diameter of 2.32 mm, mass velocities ranging from 50 to 600 kg/m(2) s and saturation temperatures of 22 degrees C, 31 degrees C and 41 degrees C. The tube was heated by applying a direct DC current to its surface. Images from a high-speed video-camera (8000 frames/s) obtained through a transparent tube just downstream the heated sections were used to identify the following flow patterns: bubbly, elongated bubbles, churn and annular flows. The visualized flow patterns were compared against the predictions provided by Barnea et al. (1983) [1], Felcar et al. (2007) [10], Revellin and Thome (2007) [3] and Ong and Thome (2009) [11]. From this comparison, it was found that the methods proposed by Felcar et al. (2007) [10] and Ong and Thome (2009) [1] predicted relatively well the present database. Additionally, elongated bubble velocities, frequencies and lengths were determined based on the analysis of high-speed videos. Results suggested that the elongated bubble velocity depends on mass velocity, vapor quality and saturation temperature. The bubble velocity increases with increasing mass velocity and vapor quality and decreases with increasing saturation temperature. Additionally, bubble velocity was correlated as linear functions of the two-phase superficial velocity. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
The objective of the present paper is to thermally characterize a cross-flow heat exchanger featuring a new cross-flow arrangement, which may find application in contemporary refrigeration and automobile industries. The new flow arrangement is peculiar in the sense that it possesses two fluid circuits extending in the form of two tube rows, each with two tube lines. To assess the heat exchanger performance, it is compared against that for the standard two-pass counter-cross-flow arrangement. The two-part comparison is based on the thermal effectiveness and the heat exchanger efficiency for several combinations of the heat capacity rate ratio, C*, and the number of transfer units, NTU. In addition, a third comparison is made in terms of the so-called ""heat exchanger reversibility norm"" (HERN) through the influence of various parameters such as the inlet temperature ratio, T, and the heat capacity rate ratio, C*, for several fixed NTU values. The proposed new flow arrangement delivers higher thermal effectiveness and higher heat exchanger efficiency, resulting in lesser entropy generation over a wide range of C* and NTU values. These metrics are quantified with respect to the arrangement widely used in refrigeration industry due to its high effectiveness, namely, the standard two-pass counter-cross-flow heat exchanger. The new flow arrangement seems to be a promising avenue in situations where cross-flow heat exchangers for single-phase fluid have to be used in refrigeration units. (c) 2009 Elsevier Masson SAS. All rights reserved.
Resumo:
This paper presents an investigation of design code provisions for steel-concrete composite columns. The study covers the national building codes of United States, Canada and Brazil, and the transnational EUROCODE. The study is based on experimental results of 93 axially loaded concrete-filled tubular steel columns. This includes 36 unpublished, full scale experimental results by the authors and 57 results from the literature. The error of resistance models is determined by comparing experimental results for ultimate loads with code-predicted column resistances. Regression analysis is used to describe the variation of model error with column slenderness and to describe model uncertainty. The paper shows that Canadian and European codes are able to predict mean column resistance, since resistance models of these codes present detailed formulations for concrete confinement by a steel tube. ANSI/AISC and Brazilian codes have limited allowance for concrete confinement, and become very conservative for short columns. Reliability analysis is used to evaluate the safety level of code provisions. Reliability analysis includes model error and other random problem parameters like steel and concrete strengths, and dead and live loads. Design code provisions are evaluated in terms of sufficient and uniform reliability criteria. Results show that the four design codes studied provide uniform reliability, with the Canadian code being best in achieving this goal. This is a result of a well balanced code, both in terms of load combinations and resistance model. The European code is less successful in providing uniform reliability, a consequence of the partial factors used in load combinations. The paper also shows that reliability indexes of columns designed according to European code can be as low as 2.2, which is quite below target reliability levels of EUROCODE. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
This paper presents the experimental results of 32 axially loaded concrete-filled steel tubular columns (CFT). The load was introduced only on the concrete core by means of two high strength steel cylinders placed at the column ends to evaluate the passive confinement provided by the steel tube. The columns were filled with structural concretes with compressive strengths of 30, 60, 80 and 100 MPa. The outer diameter (D) of the column was 114.3 mm, and the length/diameter (L/D) ratios considered were 3, 5, 7 and 10. The wall thicknesses of the tubes (t) were 3.35 mm and 6.0 mm, resulting in diameter/thickness (D/t) ratios of 34 and 19, respectively. The force vs. axial strain curves obtained from the tests showed, in general, a good post-peak behavior of the CFT columns, even for those columns filled with high strength concrete. Three analytical models of confinement for short concrete-filled columns found in the literature were used to predict the axial capacity of the columns tested. To apply these models to slender columns, a correction factor was introduced to penalize the calculated results, giving good agreement with the experimental values. Additional results of 63 CFT columns tested by other researchers were also compared to the predictions of the modified analytical models and presented satisfactory results. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
In this paper results of tests on 32 concrete-filled steel tubular columns under axial load are reported. The test parameters were the concrete compressive strength, the column slenderness (L/D) and the wall thickness (t). The test results were compared with predictions from the codes NBR 8800:2008 and EN 1994-1-1:2004 (EC4). The columns were 3, 5, 7 and 10 length to diameter ratios (L/D) and were tested with 30MPa, 60MPa, 80MPa and 100MPa concrete compressive strengths. The results of ultimate strength predicted by codes showed good agreement with experimental results. The results of NBR 8800 code were the most conservative and the EC4 showed the best results, in mean, but it was not conservative for usual concrete-filled short columns.