951 resultados para Mismatch repair
Resumo:
The aim of this study was to analyze the effect of successive TIG (tungsten inert gas) welding repairs on the reverse bending fatigue strength of AISI 4130 steel, which is widely used in components critical to the flight-safety. In order to simulate the abrupt maneuvers, wind bursts, motor vibration and helixes efforts, which generate cyclic bending loadings at the welded joints of a specific aircraft component called motor cradle, experimental reverse bending fatigue tests were carried out on specimens made from hot-rolled steel plate, 1.10 mm (0.043 in) thick, by mean of a SCHENK PWS equipment, with load ratio R = -1, under constant amplitude, at 30 Hz frequency and room temperature. It was observed that the bending fatigue strength decreases after the TIG (Tungsten Inert Gas) welding process application on AISI 4130 steel, with subsequent decrease due to re-welding sequence as well. Microstructural analyses and microhardness measurements on the base material, heat-affected zone (HAZ) and weld metal, as well as the effects of the weld bead geometry on the obtained results, have complemented this study.
Resumo:
Structures critical to the flight-safety are commonly submitted to several maintenance repairs at the welded joints in order to prolong the in-service life of aircrafts. The aim of this study is to analyze the effects of Tungsten Inert Gas (TIG) welding repair on the structural integrity of the AISI 4130 aeronautical steel by means of experimental fatigue crack growth tests in base-material, heat-affected zone (HAZ) and weld metal. The tests were performed on hot-rolled steel plate specimens, 0.89 mm thick, with load ratio R = 0.1, constant amplitude, at 10 Hz frequency and room temperature. Increase of the fracture resistance was observed in the weld metal but decreasing in the HAZ after repair. The results were associated to microhardness and microstructural changes with the welding sequence. (C) 2010 Published by Elsevier Ltd.
Resumo:
OBJETIVO: Comparar duas técnicas de tratamento da hérnia incisional em coelhos utilizando a tela de polipropileno apoiando um reforço peritônio - aponeurótico ou suturada nas bordas do anel herniário 'em ponte . MÉTODOS: Foram operados 60 coelhos para a produção de hérnia incisional, em uma incisão mediana de 4 centímetros. Após 30 dias, metade dos animais foram operados com o fechamento primário da parede, com colocação de uma tela de polipropileno apoiando o reforço e a outra metade dos animais com a colocação da tela suturada nas bordas do anel herniárioem ponte . Os animais foram avaliados com 30 (M1), 60 (M2)e 90 (M3) dias de pós-operatório. Os parâmetros analisados foram a evolução clínica, análise da força de ruptura da cicatriz, estudo macroscópico, análise microscópica e morfométrica. RESULTADOS: Não foram observadas diferenças significantes com relação a força de ruptura e estudos histológicos nos dois grupos e vários momentos estudados. Não houve diferença estatística com relação às complicações, embora os animais que receberam a telaem ponte tiveram aderências mais firmes e intensas à parede abdominal. CONCLUSÕES: As duas técnicas utilizadas para correção da hérnia incisional em coelhos não mostraram diferenças significantes quanto a força de ruptura, análise histológica e morfométrica. O número de complicações foi semelhante, porém a aderência de órgãos da cavidade abdominal à área de cicatriz foi muito mais intensa no grupo em que a tela foi colocadaem ponte .
Resumo:
We placed spheres of synthetic hydroxyapatite (calcium chloride combined with sodium phosphate) in the eviscerated or enucleated orbital cavity of rats in order to evaluate the biocompatibility of this material with the orbital cavity. The study was conducted on 50 albino rats, 25 of which were submitted to enucleation and 25 to evisceration of one eye. The animals were sacrificed 7, 15, 21, 30 and 60 days after surgery and the orbital content was submitted to histopathological examination. A reaction of the young granulation tissue type was observed first. The hydroxyapatite was gradually surrounded by a granulomatous macrophage inflammatory response and covered with dense connective tissue that formed a sort of mesh septating and supporting progressively smaller blocks of the substance. The same type of reaction was observed in the enucleated and eviscerated cavities. We conclude that synthetic hydroxyapatite is an inert nonallergenic material which is appropriate for volume replacement in the anophthalmic cavity
Resumo:
Background: An experimental study was done to assess the ability of the vegetal polymer miniplates and screws to repair defects of the orbital floor.Methods: An artificial standard-sized defect was created in the bony floor of right orbit of 45 albino rabbits. The animals were divided into three experimental groups: control group (G1) involving animals with orbital floor defect and no treatment; titanium group (G2) containing animals with orbital floor defect repaired by titanium miniplates and screws; vegetal polymer group (G3) composed of animals with similar orbital floor defects repaired by vegetal polymer miniplates and screws. Throughout the course of the experiment, the animals were clinically evaluated. At 15, 30 and 60 days after surgery, the animals were killed. They were X-rayed immediately after the floor defect and at the moment of sacrifice. Histological and morphometric evaluation of inflammatory reaction and bone healing was done. Data were statistically evaluated.Results: No implants were extruded. Bone consolidation was similar in G2 and G3 and better than in G1 group animals. Inflammatory reaction was most pronounced in animals of G3 15 days after surgery, and it subsided over time.Conclusion: Vegetal polymer miniplates and screws induces small inflammatory reaction and had the ability to stimulate bone growth with good integration in the orbital floor defect allowing to consider the vegetal polymer adequate option to treat orbital floor defects. Future studies involving long-term follow-up and biomechanical tests to evaluate material resistance to traction are needed.
Resumo:
Background: Barrier materials as cellulose membranes are used for guided tissue repair. However, it is essential that the surrounding tissues accept the device. The present study histologically evaluated tissue reaction to a microbial cellulose membrane after subcutaneous implantation in mice. Furthermore, the interaction between mesenchymal stem cells and the biomaterial was studied in vitro to evaluate its ability to act as cellular scaffold for tissue engineering.Methods: Twenty-five Swiss Albino mice were used. A 10 x 10 mm cellulose membrane obtained through biosynthesis using Acetobacter xylinum bacteria was implanted into the lumbar subcutaneous tissue of each mouse. The mice were euthanatized at seven, 15, 30, 60, and 90 days, and the membrane and surrounding tissues were collected and examined by histology.Results: A mild inflammatory response without foreign body reaction was observed until 30 days post-surgery around the implanted membrane. Polarized microscopy revealed that the membrane remained intact at all evaluation points. Scanning electron microscopy of the cellulose membrane surface showed absence of pores. The in vitro evaluation of the interaction between cells and biomaterial was performed through viability staining analysis of the cells over the biomaterial, which showed that 95% of the mesenchymal stem cells aggregating to the cellulose membrane were alive and that 5% were necrotic. Scanning electron microscopy showed mesenchymal stem cells with normal morphology and attached to the cellulose membrane surface.Conclusion: The microbial cellulose membrane evaluated was found to be nonresorbable, induced a mild inflammatory response and may prove useful as a scaffold for mesenchymal stem cells.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Two birds were presented with malunion fractures. The first was a young toco toucan (Ramphastos toco) with malunion of the tarsometatarsus that was treated by an opening-corrective osteotomy and an acrylic-pin external skeletal fixator (type II) to stabilize the osteotomy. The second bird was m adult southern caracara (Caracara plancus) with radial and ulnar malunion that was treated by closing-wedge osteotomies. Stabilization of the osteotomy sites was accomplished through 1 bone plate fixed cranially on the ulna with 6 cortical screws and an interfragmentary single wire in radius. In both cases, the malunion was corrected, but the manus of the southern caracara was amputated because of carpal joint luxation that induced malposition of the feathers.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJECTIVE: The aim of this study was to evaluate histomorphometrically the effect of alveolex (Propolis 10%) on the repair of bone cavities in the calvaria of rats. MATERIALS and METHODS: A 5 mm diameter bone defect was made in the calvaria of male Wistar rats using the drill-type trephine. The defects were filled with rhBMP-21Alveolex, rhBMP-2, Alveolex, or coagulum. Twenty-eight animals with seven subjects on each were sacrificed 30 days after surgery and samples were fixed and embedded in paraffin. Histological sections stained by HE (hematoxylin and eosin) were obtained from the calvaria bone defect and analyzed by a differential point-counting method. RESULTS: Group I and II, rhBMP-21Alveolex and rhBMP-2, respectively, presented higher levels of newly formed bone than other groups (P < 0.001). There were not significant differences between groups I and II (P > 0.05). In addition, there was not significant difference between groups III and IV, Control-Coagulum and Alveolex, respectively (P > 0.05). CONCLUSION: Alveolex has increased the bone repair in calvaria defects of rats when associated to rhBMP-2, however without significant differences for rhBMP-2 isolated group; Alveolex isolated group showed the lowest levels of newly formed bone with no significant differences to coagulum group (control). Microsc. Res. Tech. 75: 36-41, 2012. (C) 2011 Wiley Periodicals, Inc.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objective:This study investigated the efficacy of different techniques for the union of fragments of a denture before repair and on the accuracy of the reposition.Materials and methods:For this study, 20 maxillary dentures made with Lucitone 550 heat-cured resin were used. Points were determined with a scanner on the cusp of the teeth, as a measurement of the segments. After digitisation, each model was exported to the AUTOCAD R 14 program and two-dimensional measurements of the distances between the marked points were made. After the initial analysis, the dentures were fractured into two segments using an impact test machine. For the repair, maxillary dentures were divided into two groups; in the first, the repair was carried out using Kerr's sticky wax and in the second group, Super Bonder was used to join the fragments, with subsequent inclusion of DENTSPLY((R)) Repair Material resin. After the repair, the points of the maxillary dentures were measured again. The numerical values obtained were tabulated to compare the measurements before fracture and after the repair. For statistical analysis, analysis of variance was employed, using a single factor and double factor, followed by the Tukey test with a reliability of 95%.Results:The results demonstrated a statistically significant difference between the materials used to join the dentures for repair, where the dentures were joined with sticky wax presented a larger variation in the distances between the points.Conclusion:The variation in distances between the points is influenced by the agent of repair.