987 resultados para Metal-films


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biofilm adhesion to metals (copper, aluminium and brass) was studied at two different velocities and pH values of 7 and 9. Both bacteria and metals showed negative surface charges at those values of pH, which tends to slow down adhesion. Film densities increased with the fluid velocity and were also affected by the pH and by the growth rate of the bacteria. Long duration tests based on heat transfer measurements were run at five different fluid velocities and at pH = 7, showing in general an asymptotic behaviour and a control of deposition by adhesion and growth phenomena.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FUNDAMENTO: O benefício clínico de intervenção coronária percutânea (ICP) para lesões coronárias longas é incerto; além disso, foram levantadas dúvidas questões sobre a sua segurança. OBJETIVO: Avaliar os preditores de eventos cardíacos adversos maiores (ECAM) associados à ICP utilizando Full Metal Jacket (FMJ), definido como a sobreposição de stents farmacológicos (SF) medindo >60 mm de comprimento, para lesões muito longas. MÉTODOS: Foram incluídos 136 pacientes consecutivos com lesões coronárias longas, requerendo FMJ em nosso cadastro de centro único. O desfecho primário incluiu a ocorrência combinada de todas as causas de morte, infarto do miocárdio (IM) e revascularização do vaso alvo (RVA). Variáveis demográficas, clínicas, angiográficas e de procedimento foram avaliadas por meio de análise de regressão de Cox para determinar os preditores independentes de desfecho. RESULTADOS: O comprimento médio do stent por lesão foi de 73,2 ± 12,3 mm e o diâmetro médio do vaso de referência foi de 2,9 ± 0,6 mm. O sucesso angiográfico foi de 96,3%. A ausência de ECAM foi de 94,9% em 30 dias e 85,3% em um ano. No acompanhamento de um ano, a taxa de mortalidade por todas as causas foi de 3,7% (1,5% por mortes cardíacas), a taxa de IM foi de 3,7%, e a incidência de trombose de stent (TS) definitiva ou provável foi de 2,9%. O gênero feminino [risco relativo (RR), 4,40; intervalo de confiança de 95% (IC), 1,81-10,66, p = 0,001) e ICP de artéria coronária não direita (RR, 3,49; p = 0,006; IC 95%, 1,42-8,59) foram preditores independentes de ECAM em um ano. A ausência de eventos adversos em um ano foi maior em pacientes com angina estável submetidos à ICP (RR, 0,33; IC 95% 0,13-0,80, p = 0,014). CONCLUSÕES: A ICP utilizando FMJ com SF para lesões muito longas foi eficaz, mas associada a uma alta taxa de TS em acompanhamento de um ano. No entanto, a taxa de mortalidade cardíaca, IM não relacionado a procedimento, e ECAM foi relativamente baixa. ICP de vaso coronário alvo, apresentação clínica, e gênero feminino são novos fatores clínicos contemporâneos que parecem apresentar efeitos adversos sobre o resultado da ICP utilizando FMJ para lesões longas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background:Long-term outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI) remain uncertain.Objective:To investigate long-term outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in patients with ST-segment elevation myocardial infarction (STEMI).Methods:We performed search of MEDLINE, EMBASE, the Cochrane library, and ISI Web of Science (until February 2013) for randomized trials comparing more than 12-month efficacy or safety of DES with BMS in patients with STEMI. Pooled estimate was presented with risk ratio (RR) and its 95% confidence interval (CI) using random-effects model.Results:Ten trials with 7,592 participants with STEMI were included. The overall results showed that there was no significant difference in the incidence of all-cause death and definite/probable stent thrombosis between DES and BMS at long-term follow-up. Patients receiving DES implantation appeared to have a lower 1-year incidence of recurrent myocardial infarction than those receiving BMS (RR = 0.75, 95% CI 0.56 to 1.00, p= 0.05). Moreover, the risk of target vessel revascularization (TVR) after receiving DES was consistently lowered during long-term observation (all p< 0.01). In subgroup analysis, the use of everolimus-eluting stents (EES) was associated with reduced risk of stent thrombosis in STEMI patients (RR = 0.37, p=0.02).Conclusions:DES did not increase the risk of stent thrombosis in patients with STEMI compared with BMS. Moreover, the use of DES did lower long-term risk of repeat revascularization and might decrease the occurrence of reinfarction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The autonomic nervous system plays a central role in cardiovascular regulation; sympathetic activation occurs during myocardial ischemia. Objective: To assess the spectral analysis of heart rate variability during stent implantation, comparing the types of stent. Methods: This study assessed 61 patients (mean age, 64.0 years; 35 men) with ischemic heart disease and indication for stenting. Stent implantation was performed under Holter monitoring to record the spectral analysis of heart rate variability (Fourier transform), measuring the low-frequency (LF) and high-frequency (HF) components, and the LF/HF ratio before and during the procedure. Results: Bare-metal stent was implanted in 34 patients, while the others received drug-eluting stents. The right coronary artery was approached in 21 patients, the left anterior descending, in 28, and the circumflex, in 9. As compared with the pre-stenting period, all patients showed an increase in LF and HF during stent implantation (658 versus 185 ms2, p = 0.00; 322 versus 121, p = 0.00, respectively), with no change in LF/HF. During stent implantation, LF was 864 ms2 in patients with bare-metal stents, and 398 ms2 in those with drug-eluting stents (p = 0.00). The spectral analysis of heart rate variability showed no association with diabetes mellitus, family history, clinical presentation, beta-blockers, age, and vessel or its segment. Conclusions: Stent implantation resulted in concomitant sympathetic and vagal activations. Diabetes mellitus, use of beta-blockers, and the vessel approached showed no influence on the spectral analysis of heart rate variability. Sympathetic activation was lower during the implantation of drug-eluting stents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ferroelectrics, liquid delivery, MOCVD, lead zirconate titanate, strontium bismuth tantalate

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quenching process, TRIP, J2-plasticity theory, phase transition, distortion

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Naturwiss., Diss., 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Verfahrens- und Systemtechnik, Diss., 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Maschinenbau, Diss., 2013

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Naturwiss., Diss., 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ucides cordatus (Linnaeus, 1763) is a hypo-hyper-regulating mangrove crab possessing gills for respiratory and osmoregulatory processes, separated in anterior and posterior sections. They also have hepatopancreas, which is responsible for digestion and absorption of nutrients and detoxification of toxic metals. Each of these organs has specific cells that are important for in vitro studies in cell biology, ion and toxic metals transport. In order to study and characterize cells from gills and hepatopancreas, both were separated using a Sucrose Gradient (SG) from 10 to 40% and cells in each gradient were characterized using the vital mitochondrial dye DASPEI (2-(4-dimethylaminostyryl)-N- ethylpyridinium iodide) and Trichrome Mallory's stain. Both in 20 and 40% SG for gill cells and 30% SG for hepatopancreatic cells, a greater number of cells were colored with DASPEI, indicating a larger number of mitochondria in these cells. It is concluded that the gill cells present in 20% and 40% SG are Thin cells, responsible for respiratory processes and Ionocytes responsible for ion transport, respectively. For hepatopancreatic cells, the 30% SG is composed of Fibrillar cells that possess larger number of membrane ion and nutrient transporters. Moreover, the transport of toxic metal cadmium (Cd) by isolated hepatopancreatic cells was performed as a way of following cell physiological integrity after cell separation and to study differences in transport among the cells. All hepatopancreatic cells were able to transport Cd. These findings are the first step for further work on isolated cells of these important exchange epithelia of crabs, using a simple separation method and to further develop successful in vitro cell culture in crabs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En aplicaciones como la conformación en frío, donde los metales duros recubiertos con películas de naturaleza cerámica son ampliamente empleados, la existencia de un contacto mecánico repetitivo induce tensiones Hertzianas y origina el fallo por fatiga. En este trabajo, se investigan diversos recubrimientos cerámicos depositados por deposición física desde fase vapor sobre calidades diferentes de metal duro y un acero rápido pulvimetalúrgico para evaluar sus respectivas respuesta al contacto y comportamiento a fatiga. El trabajo experimental incluye la caracterización de los sistemas mediante ensayos de rayado y nanoindentación y la evaluación de las curvas tensión-deformación de indentación esférica de los sustratos, tanto desnudos como recubiertos, poniendo especial atención en determinar las tensiones de contacto críticas asociadas a la deformación plástica y a la aparición de grietas circulares en la superficie recubierta. A este estudio, le siguen numerosos ensayos a fatiga a cargas inferiores a aquéllas identificadas como críticas bajo carga monotónica y para un número de ciclos comprendido entre 1.000 y 1.000.000 de ciclos. Los resultados experimentales indican que las películas cerámicas no parecen desempeñar un papel relevante en la aparición de la cedencia plástica, siendo la deformación plástica global controlada por la deformación del sustrato. No obstante, para tensiones elevadas de indentación durante el régimen plástico, existe la aparición de grietas circulares en los recubrimientos cerámicos. Además, la aparición de las mismas es sensible a la fatiga por contacto. Este análisis mecánico se complementa con una inspección detallada del daño generado en profundidad y superficie.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study the existence of solutions to general measure-minimization problems over topological classes that are stable under localized Lipschitz homotopy, including the standard Plateau problem without the need for restrictive assumptions such as orientability or even rectifiability of surfaces. In case of problems over an open and bounded domain we establish the existence of a “minimal candidate”, obtained as the limit for the local Hausdorff convergence of a minimizing sequence for which the measure is lower-semicontinuous. Although we do not give a way to control the topological constraint when taking limit yet— except for some examples of topological classes preserving local separation or for periodic two-dimensional sets — we prove that this candidate is an Almgren-minimal set. Thus, using regularity results such as Jean Taylor’s theorem, this could be a way to find solutions to the above minimization problems under a generic setup in arbitrary dimension and codimension.