998 resultados para Implante de Prótese
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to evaluate the behavior of reinforced composites with polyamide 6 fibers aligned (6000 rpm) and alignment (120 rpm) with or without CNT using the flexural strength test. After preparation of nanofibers aligned nylon 6 (6000 rpm) and alignment (120 rpm) with and without incorporation of nanotube carbon by the method of electrospinning, were performed one control group (n = 10) and 4 experimental groups (n = 40) G1: Control (just resin Charisma - Heraeus Kulzer) ;G2 Resin + N6 aligned (6000 rpm) + CNT; G3:Resin + N6 alignment (120 rpm) + CNT; G4: Resin + aligned ( 6000 rpm) N6. G5: Resin + N6 alignment (120 rpm). The fibers were cut to the dimensions of 0,3 x 15 mm and were applied an adhesive at the surface (Single Bond 2) for 5 min and cured. In the matrix, was added resin in the proximal box (Charisma A2, Heraeus Kulzer) and cured for 40 s. (power 1100 mW / cm²). A first layer of resin and on the resin was deposited. The resin layers specimens were light irradiated with three overlapping exposures delivered. For each resin layer were light irradiated for 40 sec. The samples were tested with a cross-speed of 1 mm / min, and a 50 Kgf at Universal testing machine (EMIC mod.DL2000). The Dunnet test showed that only the nanotube group was significantly different from the control group. The ANOVA two-way indicates that the nanotube factor was statistically significant (p < 0.05) and there is no interaction between factors and orientation nanotube. The presence of nanotube showed lower fracture resistance values for aligned and unaligned groups. The results of this study showed that the orientation of the fibers does not influence the strength of composite resins and the incorporation of nylon nanofibers with carbon nanotubes decreased the fracture resistance values. The presence of the fibers has not been able to improve the strength of the material in any of the...
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Dado o âmbito multidimensional do implante coclear, há crescente necessidade em avaliar não somente medidas clínicas de eficácia relacionadas às habilidades comunicativas, mas também aspectos mais genéricos envolvidos na efetividade do tratamento, como a qualidade de vida. OBJETIVOS: Tradução e adaptação de questionário internacional para o Português Brasileiro; análise das correlações entre fatores relacionados à qualidade de vida; análise das correlações entre qualidade de vida e medidas clínicas de resultado. MATERIAL E MÉTODO: Estudo prospectivo realizado com pais de crianças com implante coclear consistindo na aplicação de instrumentos validados para avaliar aspectos de qualidade de vida e habilidades comunicativas. RESULTADOS: A tradução e adaptação cultural do questionário foi satisfatoriamente realizada e este estudo proporciona a disponibilização do questionário em versão para o Português Brasileiro. Pelos dados obtidos, o implante coclear apresentou efeito positivo na qualidade de vida das crianças implantadas e de suas famílias. As correlações observadas para a variável comunicação demonstram uma relação direta entre comunicação oral e outras variáveis de qualidade de vida. CONCLUSÃO: Este estudo disponibiliza o questionário em versão para o Português Brasileiro. Para os pais de crianças brasileiras usuárias de implante coclear, a habilidade lexical (aquisição e uso das palavras) é a variável de maior impacto na qualidade de vida de seus filhos.
Resumo:
Pensando em melhorar a qualidade de vida dos pacientes com doenças do humor vítreo, os oftalmologistas começaram a utilizar recentemente implantes biodegradáveis com corticoide. Estes mesmos implantes podem ser uma alternativa no tratamento da RSC e, para isso, realizamos um estudo experimental em seios maxilares de coelhos. OBJETIVO: Avaliar histologicamente a mucosa de seio maxilar de coelhos após a colocação de implante biodegradável de prednisolona. MÉTODO: Dezoito coelhos foram divididos aleatoriamente em dois grupos: Grupo 1: no seio maxilar esquerdo foi inserido um implante biodegradável com prednisolona; Grupo 2: No seio maxilar esquerdo foi inserido um implante biodegradável sem medicação. Os seios maxilares do lado direito serviram como controle. Após 7, 14 e 28 dias foram escolhidos aleatoriamente três coelhos de cada grupo e a resposta tecidual inflamatória foi avaliada. RESULTADOS: Foi encontrada diferença não significativa de inflamação na mucosa, quando comparamos o grupo de coelhos que receberam implantes com e sem medicação com o grupo controle; ou quando comparamos o grupo que recebeu implante com prednisolona com o grupo que recebeu implante sem medicação. CONCLUSÃO: Não foram observados sinais de toxicidade ou inflamação na mucosa do seio maxilar do coelho à presença do implante com ou sem prednisolona.
Resumo:
From a recent perspective the morse-taper dental implants connections are increasingly being used as an alternative for replacement of a missing teeth. Nevertheless, there are a large variety of prosthetic components available on the market with some limitations regarding the final prothesis. This article demonstrated the difficulties and limitations of prosthesis implant-retained connections when using morse-taper implants (with a prosthetic index) case in which the surgical placement of the implant wasn’t successfully performed. The alternative to overcome this scenario was the technique using the tube screw over the top of a mini abutment component. It was possible to manufacture and to have satisfactory adaptation, achieving the satisfaction of the patient, restoring function and esthetics.
Resumo:
The use of cochlear implant (CI) in children enables the development of listening and communication skills, allowing the child's progress in school and to be able to obtain, maintain and carry out an occupation. However, the progress after the CI has different results in some children, because many children are able to interact and participate in society, while others develop limited ability to communicate verbally. The need for a better understanding of CI outcomes, besides hearing and language benefits, has spurred the inclusion of quality of life measurements (QOL) to assess the impact of this technology. OBJECTIVE: Identify the key aspects of quality of life assessed in children with cochlear implant. METHOD: Through a systematic literature review, we considered publications from the period of 2000 to 2011. CONCLUSION: We concluded that QOL measurements in children include several concepts and methodologies. When referring to children using CI, results showed the challenges in broadly conceptualizing which quality of life domains are important to the child and how these areas can evolve during development, considering the wide variety of instruments and aspects evaluated.
Resumo:
Purpose: To characterize the profile of patients with cochlear implant as proposed by the International Classification of Functioning, Disability and Health for Children and Youth (ICF-CY). Methods: This is a descriptive, crosssectional retrospective study, which examined 30 medical records of patients using the cochlear implant of Centro de Pesquisas Audiológicas. To characterize the profile of the patients, the ICF-CY was used. Regarding the assessment, researchers relied on procedures performed in clinical routine, besides information registered in the medical record. After reviewing the information, it was related to codes from the ICF-CY; with the addition of a qualifier afterwards. Results: Overall, 55 codes from the ICF were related to the instruments to characterize this population. Regarding the Body Functions field, most participants did not have disabilities related to reception and expression of oral language and auditory functions, with only written language disabilities being found. These same findings were observed in the Activity and Participation Field. Regarding environmental factors, noise and the non-availability of technology resources to assist in the auditory comprehension of noise were characterized as a barrier, as well as the absence of speech therapy. Conclusion: This study concluded that most of the participating children showed no deficiency in the body functions, with difficulties being only reported in relation to school performance. Environmental factors (noise, non-availability of technological resources, absence of speech therapy) were characterized as a barrier. The need to expand assessments in the clinical routine was also noted.
Resumo:
Este estudo teve como objetivo averiguar, antes e após o uso do implante coclear, a dimensão afetiva em pacientes adultos com surdez adquirida, no que diz respeito às modalidades dos sentimentos egoicos, sentimentos em relação ao próximo, sentimentos de temporalidade e estados de ânimo. Participaram 44 adultos que realizaram o implante coclear no Centro de Pesquisas Audiológicas do Hospital de Reabilitação de Anomalias Craniofaciais da Universidade de São Paulo de Bauru. Concluiu-se que, na vivência da surdez, houve predomínio de sentimentos negativos e de um clima afetivo de tensão e depressão, que levava o sujeito a uma vinculação negativa, de assintonia com o mundo. Entretanto, na vivência com o implante coclear, houve predomínio de sentimentos positivos e de um clima afetivo de tranquilidade e contentamento, observando-se uma vinculação positiva do sujeito e sintonia com o mundo.
Resumo:
OBJETIVO: avaliar e caracterizar o desempenho escolar de crianças com deficiência auditiva usuárias de implante coclear, entre 9 e 12 anos, assim como, verificar o tempo que a criança leva para acessar a informação fonológica e confrontar estes resultados de acordo com o gênero e série dos participantes. MÉTODO: participaram deste estudo 32 crianças, de ambos os gêneros, freqüentando da primeira a quinta séries do ensino fundamental, regularmente matriculadas no Centro de Pesquisas Audiológicas do Hospital de Reabilitação de Anomalias Craniofaciais, Universidade de São Paulo, na cidade de Bauru/SP. Os instrumentos utilizados foram o Teste de Desempenho Escolar (TDE) e o Teste de Nomeação Automática Rápida (RAN). RESULTADOS: os resultados mostraram que 74% das crianças apresentaram desempenho escolar geral abaixo do esperado, com maior dificuldade na escrita e dentro da média para o tempo que levam ao processar a informação. CONCLUSÕES: concluiu-se que 74% das crianças apresentaram desempenho escolar inferior nas avaliações e que não houve relação entre estes resultados com a nomeação rápida, já que este está dentro da média e é um pré-requisito para a leitura, e os participantes deste estudo apresentam habilidade satisfatória para a leitura.
Resumo:
OBJETIVO: Pacientes com lesão medular cervical alta em geral são dependentes de ventilação mecânica, que, embora salve vidas, está associada a complicações e redução da expectativa de vida devido a infecções respiratórias. A estimulação do diafragma por marca-passo, às vezes chamada de ventilação elétrica, induz a inspiração por estimulação dos músculos inspiratórios. Nosso objetivo foi destacar as indicações e alguns aspectos da técnica cirúrgica empregada no implante laparoscópico dos eletrodos, assim como descrever cinco casos de pacientes tetraplégicos submetidos à técnica. MÉTODOS: A seleção dos pacientes envolveu estudos de condução do nervo frênico por via transcutânea para determinar se os nervos estavam preservados. A abordagem cirúrgica foi laparoscopia clássica, com quatro trocartes. A técnica foi iniciada com o mapeamento elétrico para encontrar os "pontos motores" (pontos de contração máxima do diafragma). Se o mapeamento era bem-sucedido, dois eletrodos eram implantados na face abdominal de cada lado do diafragma para estimular ramos do nervo frênico. RESULTADOS: Dos cinco pacientes, três e um, respectivamente, eram capazes de respirar somente com o uso do marca-passo por períodos superiores a 24 e 6 h, enquanto um não era capaz. CONCLUSÕES: Embora seja necessário um acompanhamento mais longo para chegar a conclusões definitivas, os resultados iniciais são promissores, pois, no momento, a maioria dos nossos pacientes pode permanecer sem ventilação mecânica por longos períodos de tempo.
Resumo:
Dado o âmbito multidimensional do implante coclear, há crescente necessidade em avaliar não somente medidas clínicas de eficácia relacionadas às habilidades comunicativas, mas também aspectos mais genéricos envolvidos na efetividade do tratamento, como a qualidade de vida. OBJETIVOS: Tradução e adaptação de questionário internacional para o Português Brasileiro; análise das correlações entre fatores relacionados à qualidade de vida; análise das correlações entre qualidade de vida e medidas clínicas de resultado. MATERIAL E MÉTODO: Estudo prospectivo realizado com pais de crianças com implante coclear consistindo na aplicação de instrumentos validados para avaliar aspectos de qualidade de vida e habilidades comunicativas. RESULTADOS: A tradução e adaptação cultural do questionário foi satisfatoriamente realizada e este estudo proporciona a disponibilização do questionário em versão para o Português Brasileiro. Pelos dados obtidos, o implante coclear apresentou efeito positivo na qualidade de vida das crianças implantadas e de suas famílias. As correlações observadas para a variável comunicação demonstram uma relação direta entre comunicação oral e outras variáveis de qualidade de vida. CONCLUSÃO: Este estudo disponibiliza o questionário em versão para o Português Brasileiro. Para os pais de crianças brasileiras usuárias de implante coclear, a habilidade lexical (aquisição e uso das palavras) é a variável de maior impacto na qualidade de vida de seus filhos.
Resumo:
Considerando a indisponibilidade de equipamentos avançados de aquisição de imagens nos centros cirúrgicos da maioria dos centros hospitalares e a importância fundamental que têm para o cirurgião uma visualização imediata do implante coclear logo após sua inserção, uma boa opção é a utilização da radiografia convencional. OBJETIVO: Descrever um método radiográfico rápido prático e de baixo custo, que permita avaliar não só a posição, mas também a integridade dos eletrodos, na instalação do implante coclear. MATERIAL E MÉTODO: Foram analisadas radiografias de 262 pacientes submetidos à cirurgia de implante coclear entre Março/2005 e Outubro/2008, com radiografia transoperatória, logo após a inserção dos eletrodos. As radiografias foram analisadas pelo cirurgião no transoperatório e, posteriormente, pelo médico radiologista. RESULTADOS: Foram analisadas 524 radiografias das quais, 95,61% apresentavam técnica adequada, com posicionamento do paciente dentro da técnica descrita neste estudo e boa visualização dos eletrodos, sendo consideradas satisfatórias e 4,39% apresentavam técnica inadequada e/ou visualização insatisfatória dos eletrodos, sendo consideradas insatisfatórias. CONCLUSÃO: Apesar dos aparelhos de Raios X portáteis possuírem limitações, utilizando técnicas e acessórios adequados, é possível conseguir radiografias com resultados satisfatórios para visualização dos implantes cocleares.