935 resultados para High Performance


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Over the last two decades, high performance work systems (HPWSs) research has been dominated by examining the effects of these systems on firm performance. Research on the impact of HPWSs on employees has been marginalised. This study examines the impact of HPWSs on two psychological outcomes for employees, namely, subjective well-being (SWB) and workplace burnout, by utilising data collected from 1488 physicians and nurses in 25 Chinese hospitals. It also examines the moderating effects of employees' organisational based self-esteem (OBSE), as an individual intervention and physician–nurse relationships, as an organisational intervention, on the relationship between HPWSs and employee outcomes. HPWS is found to increase employees' SWB and decrease burnout. Such well-being-enhancing and burnout-relieving effects are stronger when employees have high OBSE. The positive effect of HPWS on SWB is also stronger when there is a collaborative relationship among employees in an organisation. The major contribution of this study is to unpack the ‘black box’ of how HPWS influences employee well-being in the Chinese healthcare sector context.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To achieve the greatest peak capacity in two-dimensional high performance liquid chromatography (2D-HPLC) a gradient should be operated in both separation dimensions. However, it is known that when an injection solvent that is stronger than the initial mobile phase composition is deleterious to peak performance, thus causing problems when cutting a portion from one gradient into another. This was overcome when coupling hydrophilic interaction with reversed phase chromatography by introducing a counter gradient that changed the solvent strength of the second dimension injection. It was found that an injection solvent composition of 20% acetonitrile in water gave acceptable results in one-dimensional simulations with an initial composition of 5% acetonitrile. When this was transferred to a 2D-HPLC separation of standards it was found that a marked improvement in peak shape was gained for the moderately retained analytes (phenol and dimethyl phthalate), some improvement for the weakly retained caffeine and very little change for the strongly retained n-propylbenzene and anthracene which already displayed good chromatographic profiles. This effect was transferred when applied to a 2D-HPLC separation of a coffee extract where the indecipherable retention profile was transformed to a successful application multidimensional chromatography with peaks occupying 71% of the separation space according to the geometric approach to factor analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Australia is viewed as leader in the field of sports science, with Australian sports scientists highly sought after and respected worldwide. However, despite the important contribution of sports scientists to the development of professional sport in Australia, we know little about these sport professionals who play an important role in the development and success of athletes, teams and sport organisations.
This report provides a more formal understanding of the high performance and sports science workforce with the purpose of informing the policy development of Australia’s sport governing bodies and education providers to inform sport management practices that will enhance the support and development of current and future high performance managers and sports scientists. The data presented in this report provides valuable insight about the scope of the profession to enable further development of strategic plans for the industry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

High performance liquid chromatography (HPLC) is an enabling science with application in all scientific disciplines requiring analysis or purification. The research described here details performance aspects of the chromatography column, which lead to a new design concept in the chromatography column. Studies were also undertaken to characterise selectivity leading to new stationary phases. Research on fluid dynamics in packed beds showed how a mismatch in solvent viscosities between the injection plug and mobile pahse influences the performance of on-line multidimentional HPLC. Selectivity id detection was also examined in an effort to better understand sample analysis. 

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The synthesis and chromatographic behavior of an analytical size mixed-mode bonded silica monolith was investigated. The monolith was functionalized by an in situ modification process of a bare silica rod with chloro(3-cyanopropyl)dimethyl silane and chlorodimethyl propyl phenyl silane solutions. These ligands were selected in order to combine both resonance and nonresonance π-type bonding within a single separation environment. Selectivity studies were undertaken using n-alkyl benzenes and polycyclic aromatic hydrocarbons in aqueous methanol and acetonitrile mobile phases to assess the methylene and aromatic selectivities of the column. The results fit with the linear solvent strength theory suggesting excellent selectivity of the column was achieved. Comparison studies were performed on monolithic columns that were functionalized separately with cyano and phenyl ligands, suggesting highly conjugated molecules were able to successfully exploit both of the π-type selectivities afforded by the two different ligands on the mixed-mode column.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A position sensorless Surface Permanent Magnet Synchronous Motor (SPMSM) drive based on flux angle is presented in this paper. The motor equations are written in rotor fixed d-q reference frame. A PID controller is used to process the speed error to generate the reference torque current keeping the magnetizing current fixed. The estimated stator flux using Recurrent Neural Network (RNN) is used to find out the rotor position. The flux angle and the reference current phasor angle are used in vector rotator to generate the reference phase currents. Hysteresis current controller block controls the switching of the 3-phase inverter to apply voltage to the motor stator. Simulation studies on different operating conditions indicate the acceptability of the drive system. The drive system only requires a speed transducer and is free from position sensor requirement. The proposed control scheme is robust under load torque disturbances and motor parameter variations. It is also simple and low cost to implement in a practical environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As an electrical double layer capacitor, dry-spun carbon nanotube yarn possesses relatively low specific capacitance. This can be significantly increased as a result of the pseudocapacitance of functional groups on the carbon nanotubes developed by oxidation using a gamma irradiation treatment in the presence of air. When coated with high-performance polyaniline nanowires, the gamma-irradiated carbon nanotube yarn acts as a high-strength reinforcement and a high-efficiency current collector in two-ply yarn supercapacitors for transporting charges generated along the long electrodes. The resulting supercapacitors demonstrate excellent electrochemical performance, cycle stability, and resistance to folding-unfolding that are required in wearable electronic textiles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sandwich-type hybrid carbon nanosheets (SCNMM) consisting of graphene and micro/mesoporous carbon layer are fabricated via a double template method using graphene oxide as the shape-directing agent and SiO2 nanoparticles as the mesoporous guide. The polypyrrole synthesized in situ on the graphene oxide sheets is used as a carbon precursor. The micro/mesoporous strcutures of the SCNMM are created by a carbonization process followed by HF solution etching and KOH treatment. Sulfur is impregnated into the hybrid carbon nanosheets to generate S@SCNMM composites for the cathode materials in Li-S secondary batteries. The microstructures and electrochemical performance of the as-prepared samples are investigated in detail. The hybrid carbon nanosheets, which have a thickness of about 10-25 nm, high surface area of 1588 m2 g-1, and broad pore size distribution of 0.8-6.0 nm, are highly interconnected to form a 3D hierarchical structure. The S@SCNMM sample with the sulfur content of 74 wt% exhibits excellent electrochemical performance, including large reversible capacity, good cycling stability and coulombic efficiency, and good rate capability, which is believed to be due to the structure of hybrid carbon materials with hierarchical porous structure, which have large specific surface area and pore volume.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In-silico optimised two-dimensional high performance liquid chromatographic (2D-HPLC) separations of a model methamphetamine seizure sample are described, where an excellent match between simulated and real separations was observed. Targeted separation of model compounds was completed with significantly reduced method development time. This separation was completed in the heart-cutting mode of 2D-HPLC where C18 columns were used in both dimensions taking advantage of the selectivity difference of methanol and acetonitrile as the mobile phases. This method development protocol is most significant when optimising the separation of chemically similar chemical compounds as it eliminates potentially hours of trial and error injections to identify the optimised experimental conditions. After only four screening injections the gradient profile for both 2D-HPLC dimensions could be optimised via simulations, ensuring the baseline resolution of diastereomers (ephedrine and pseudoephedrine) in 9.7 min. Depending on which diastereomer is present the potential synthetic pathway can be categorized.