991 resultados para Food preservation technique
Resumo:
Dissertação apresentada para a obtenção do grau de doutor em Bioquímica pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
Visceral larva migrans (VLM) is a clinical syndrome caused by infection of man by Toxocara spp, the common roundworm of dogs and cats. Tissue migration of larval stages causes illness specially in children. Because larvae are difficult to detect in tissues, diagnosis is mostly based on serology. After the introduction of the enzyme-linked immunosorbent assay (ELISA) using the larval excretory-secretory antigen of T. canis (TES), the diagnosis specificity was greatly improved although cross-reactivity with other helminths are still being reported. In Brazil, diagnosis is routinely made after absorption of serum samples with Ascaris suum antigens, a nematode antigenicaly related with Ascaris lumbricoides which is a common intestinal nematode of children. In order to identify T. canis antigens that cross react to A. suum antigens we analyzed TES antigen by SDS-PAGE and Western blotting techniques. When we used serum samples from patients suspected of VLM and positive result by ELISA as well as a reference serum sample numerous bands were seen (molecular weight of 210-200 kDa, 116-97 kDa, 55-50 kDa and 35-29 kDa). Among these there is at least one band with molecular weight around 55-66 kDa that seem to be responsible for the cross-reactivity between T. canis e A. suum once it disappears when previous absorption of serum samples with A. suum antigens is performed
Resumo:
No dia-a-dia, os organismos vivos estão sujeitos a vários tipos de agressões de origem endógena e exógena. A produção endógena exagerada de agentes oxidantes que ocorre nos processos metabólicos dos seres vivos está intimamente associada ao aparecimento e desenvolvimento de várias patologias. Por outro lado, e devido às atividades antropogénicas, muitos agentes oxidantes de origem ambiental e alimentar entram por via exógena no organismo dos seres vivos provocando igualmente danos a nível celular. De modo a protegerem-se dos efeitos pejorativos provocados por estes compostos, os organismos vivos desenvolveram mecanismos complexos de defesa antioxidante. Este trabalho consistiu no estudo eletroquímico do dano oxidativo induzido por agentes oxidantes (PAH (hidrocarbonetos aromáticos policíclicos), H2O2, NO• e HClO) e do efeito protetor, ao dano oxidativo, promovido por antioxidantes no material baseado no ADN recorrendo à utilização de um biossensor de bases púricas, adenina-EPC (elétrodo pasta de carbono) e dA20-EPC, utilizando a voltametria de onda quadrada (VOQ) como técnica de deteção. A aplicação da eletroquímica apresenta várias vantagens para a quantificação da capacidade antioxidante total (CAT) pois, permite a redução da quantidade de reagentes e amostra em análise, elimina a etapa de remoção de cor (a cor é um interferente nos métodos óticos) e não requer equipamentos dispendiosos. Foram seguidas diferentes abordagens para a construção dos biossensores. A primeira consistiu na construção de um adenina-EPC em três etapas: i) condicionamento do EPC, ii) eletrodeposição da adenina no EPC e iii) leitura do sinal eletroquímico. Assim, foram otimizados diversos parâmetros: concentração de adenina (150,0 mg/L), potencial de condicionamento (Ec) (+ 1,80 V), potencial de deposição (Ed) (+ 0,40 V), tempo de condicionamento (tc) (180 s) e tempo de deposição (td) (240 s). Foi aplicado o adenina-EPC no estudo do dano oxidativo provocado por PAH (benzo (g,h,i) perileno) e constatou-se que era necessário transformar o benzo (g,h,i) perileno num radical para se possível observar danos oxidativos induzidos no biossensor. A nova estratégia consistiu na construção de um dA20-EPC, através da adsorção física de uma gota de dA20 na superfície do EPC, com posterior secagem e leitura do sinal eletroquímico. Neste procedimento foi otimizada a concentração de dA20 (100,0 mg/L). O dano oxidativo provocado pelo H2O2, NO• e HClO foi estudado sobre o dA20-EPC e verificou-se que os três agentes oxidantes induziam dano oxidativo no dA20-EPC. Confirmou-se a capacidade do ácido ascórbico (AA) em proteger o dA20-EPC do dano oxidativo induzido por H2O2 e NO•. O biossensor desenvolvido (dA20-EPC) foi aplicado na avaliação da CAT de diferentes amostras reais (café, sumo de laranja e água aromatizada de laranja) usando-se como agentes oxidantes o H2O2 e NO•. Todas as amostras analisadas apresentaram ter capacidade antioxidante. Quando se utilizou o dA20-EPC na presença de H2O2, verificou-se que as amostras de café apresentam valores mais elevados de CAT (1130-1488 mg AAE/L) do que as amostras de bebidas (110 mg AAE/L em água aromatizada e 775 mg AAE/L em sumo). Os valores de CAT obtidos para amostras de sumo e água aromatizada na presença de NO• indicam que a amostra de sumo possui maior teor de CAT (871 mg AAE/L) conforme era esperado, do que a amostra de água aromatizada (172 mg AAE/L). Na presença de HClO, o valor de CAT mais elevado pertence a uma amostra de sumo (513 mg AAE/L) mas, o valor de CAT da amostra de sumo natural é muito mais baixa do que o esperado (17 mg AAE/L). Foram estudados outros antioxidantes para além do AA (ácido cumárico, ácido gálico e ácido cafeico), e constatou-se que cada um deles promove proteção ao dA20-EPC na presença de cada um dos diferentes contaminantes (H2O2, NO• e HClO).
Resumo:
We report an adaptation of a technique for the blood sample collection (GFM) as well as for the extraction and amplification of Plasmodium DNA for the diagnosis of malaria infection by the PCR/ELISA. The method of blood sample collection requires less expertise and saves both time and money, thus reducing the cost by more than half. The material is also suitable for genetic analysis in either fresh or stored specimens prepared by this method.
Resumo:
Dissertation presented at Faculdade de Ciências e Tecnologia from Universidade Nova de Lisboa to obtain the degree of Master in Chemical and Biochemical Engineering
Resumo:
Three GST fusion recombinant antigen of Treponema pallidum, described as GST-rTp47, GST-rTp17 and GST-rTp15 were analyzed by Western blotting techniques. We have tested 53 serum samples: 25 from patients at different clinical stages of syphilis, all of them presenting anti-treponemal antibody, 25 from healthy blood donors and three from patients with sexually transmitted disease (STD) other than syphilis. Almost all samples from patients with syphilis presented a strong reactivity with GST-rTp17 antigen. Some samples were non-reactive or showed a weak reaction with GST-rTp47 and/or GST-rTp15, and apparently there was no correlation with the stage of disease. There was no seropositivity among blood donors. No sample reacted with purified GST. We concluded that due to their specificity these recombinant antigens can be used as GST fusion protein for development of syphilis diagnostic assays.
Resumo:
The RID assay is one of the in vitro methods used for in-process control in the production of rabies vaccines for veterinary use. It has been shown to be very useful for determining antigen concentration in the final bulk product. The work presented in this paper, including the production and standardization of candidate standard reagents for use in the Radial Immunodiffusion Assay (RID) was carried out at the Pan American Institute for Food Protection and Zoonoses (INPPAZ/PAHO/WHO). The study was completed with the cooperation of the Faculty of Veterinary Sciences, National University of La Plata (NULP), Argentina, where the validation of the proposed standards and the quality control of samples from 28 different batches of rabies vaccines produced with Pasteur strain rabies virus (PV) in BHK cells were performed. The activity of the vaccines was determined by in vivo (NIH) and in vitro (RID)assays. The results of the candidate reagents for the reagent standardization tests showed stability, sensitivity and reproducibility. The Relative Potency the 1.2 between the problem vaccines and the reference vaccine was estimated by variance and regression analysis. The results of our validation study show that the INPPAZ (PAHO/WHO) is capable of producing and distributing the above-mentioned standard reagents, as well as of providing support for the incorporation of the RID technique (sensitive, rapid and inexpensive) to the laboratories that manufacture rabies vaccines in Latin America and the Caribbean.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Conservação e Restauro
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Conservação e Restauro, especialização em pintura sobre tela
Resumo:
Laboratory investigation of botulism from 1982 to 2001 confirmed the occurrence of eight positive outbreaks/cases of botulism in Brazil. From those, type A botulism was observed in seven of them. Biological material of one case (serum and feces) was positive in the first step of the bioassay, but the amount of sample was not sufficient for typification. One of the outbreaks that occurred in 2001 was negative for botulinum toxin in samples of serum, gastric washing and feces, collected eight days before the onset of the symptoms in the affected person who was clinically diagnosed as presenting the disease. Other two cases presenting compatible clinical diagnoses presented negative results. However, in those cases, the collection of samples was (1) after antiserum administration or (2) later than eight days of the onset of symptoms. Investigation was performed by mouse bioassay, as described in the Compendium of Methods for the Microbiological Examination of Foods (compiled by American Public Health Association - APHA)11, using specific antiserum from Centers for Disease Control (CDC), USA.
Resumo:
272 isolates of Salmonella Enteritidis (111 isolated from frozen broiler chicken carcasses, 126 from human food and other biological materials involved in food poisoning outbreaks and 35 from different poultry materials) were selected for phage typing. From these, 111 were phage typed, 57.65% being classified as phage type 4, 32.43% as phage type 4a, 3.60% as phage type 6a and 0.90% as phage type 7, whereas 5.40% samples were not phage typeable. The predominance of phage type 4 is in agreement with the results published worldwide, and reinforces the need for studies related to the epidemiological meaning of these findings.
Resumo:
The formalin-Tween sedimentation method was compared with the formalin-ether sedimentation for parasitic detection. Of a total 297 fecal specimens examined, 72.1% were positive. The formalin-tween technique was effective for ascertaining helminths, particularly Ascaris lumbricoides, Trichuris trichiura and hookworm eggs; however it has less capability for protozoa detection. This method is simple, inexpensive, less time consuming and highly sensitive when detecting the parasitic infection, particularly when focusing on helminth eggs.
Resumo:
A rapid test based on an immunochromatography assay - Determine Syphilis TP (Abbott Lab.) for detecting specific antibodies to Treponema pallidum was evaluated against serum samples from patients with clinical, epidemiological and serological diagnosis of syphilis, patients with sexually transmitted disease other than syphilis, and individuals with negative serology for syphilis. The Determine test presented the sensitivity of 93.6%, specificity of 92.5%, and positive predictive value and negative predictive value of 95.2% and 93.7%, respectively. One serum sample from patient with recent latent syphilis showed a prozone reaction. Determine is a rapid assay, highly specific and easy to perform. This technique obviates the need of equipment and its diagnostic features demonstrate that it may be applicable as an alternative assay for syphilis screening under some emergency conditions or for patients living in remote localities.
Resumo:
Progressive disseminated histoplasmosis (PDH) is an increasingly common cause of infection in patients with acquired immune deficiency syndrome (AIDS). We report 21 cases of PDH associated with AIDS diagnosed by lysis-centrifugation blood culture method. The most prevalent clinical findings were fever, weight loss, respiratory symptoms, and mucocutaneous lesions. Chest roentgenogram showed diffuse pulmonary infiltrates in 13 of 21 patients (62%). Brochoalveolar fluid has yelded positive culture in four patients only in medium with cycloheximide.
Resumo:
A gold nanoparticle-coated screen-printed carbon electrode was used as the transducer in the development of an electrochemical immunosensor for Ara h 1 (a major peanut allergen) detection in food samples. Gold nanoparticles (average diameter=32 nm) were electrochemically generated on the surface of screen-printed carbon electrodes. Two monoclonal antibodies were used in a sandwich-type immunoassay and the antibody–antigen interaction was electrochemically detected through stripping analysis of enzymatically (using alkaline phosphatase) deposited silver. The total time of the optimized immunoassay was 3 h 50 min. The developed immunosensor allowed the quantification of Ara h 1 between 12.6 and 2000 ng/ml, with a limit of detection of 3.8 ng/ml, and provided precise (RSD <8.7%) and accurate (recovery >96.6%) results. The immunosensor was successfully applied to the analysis of complex food matrices (cookies and chocolate), being able to detect Ara h 1 in samples containing 0.1% of peanut.