1000 resultados para COMUNIDAD ANDINA-CAN


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Adequate energy provision and nitrogen losses prevention of critically ill patients are essentials for treatment and recovery. The aims of this study were to evaluate energy expenditure (EE) and nitrogen balance (NB) of critically ill patients, to classify adequacy of energy intake (El), and to verify adequacy of El capacity to reverse the negative NB. Methods: Seventeen patients from an intensive care unit were evaluated within a 24-hour period. Indirect calorimetry was performed to calculate patient`s EE and Kjeldhal for urinary nitrogen analysis. The total El and protein intake were calculated from the standard parenteral and enteral nutrition infused. Underfeeding was characterized as El 90% or less and overfeeding as 110% or greater of EE. The adequacy of the El (El EE(-1) x 100) and the NB were estimated and associated with each other by Spearman coefficient. Results: The mean EE was 1515 +/- 268 kcal d(-1) and most of the patients (11/14) presented a negative NB (-8.2 +/- 4.7 g.d(-1)). A high rate (53%) of inadequate energy intake was found, and a positive correlation between El EE(-1) and NB was observed (r = 0.670; P = .007). Conclusion: The results show a high rate of inadequate El and negative NB, and equilibrium between El and EE may improve NB. Indirect calorimetry can be used to adjust the energy requirements in the critically ill patients. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have used an experimental model of aorta stenosis, with a Plexiglas plug, simulating a stable atheromatous plaque that promotes local turbulence and thrombosis. With animal survival of more than 24 h, we followed the partial fibrinolysis of the thrombus as well as its posterior organization and incorporation to the arterial wall as a neointima for up to 30 days. The mushroom plug form permitted the development of recirculation and stasis areas around it, favouring this evolution. Despite noted limitations, this study demonstrates that thrombus incorporation can contribute to plaque extension, as it can promote recirculation and stasis areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Association between insulin resistance (IR) and non-alcoholic fatty liver disease (NAFLD) has been reported. This prompted us to evaluate the power of the insulin sensitivity index (ISI) in association with IGFBP-1 to identify IR early in obese children/adolescents. OGTT was performed in 34 obese/overweight children/adolescents. Glucose, insulin and IGFBP-1 were measured in serum samples and ISI was calculated. Considering the presence of three or more risk factors for IR as a criterion for IR, ISI <4.6 showed 87.5% sensitivity and 94.5% specificity in diagnosing IR. IGFBP-1 was lower in the group with ISI <4.6 (p <0.01). In this group, three patients had higher than expected IGFBP-1, suggesting hepatic IR, while three patients with ISI >4.6 showed very low IGFBP-1 levels. Conclusion: ISI <4.6 is a good indicator of early peripheral IR and, associated with IGFBP-1, can identify increased risk of hepatic IR. Low IGFBP-1 levels among non-IR children may indicate increased portal insulin levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study evaluated the immediate and 6-month resin-dentin mu-bond strength (mu TBS) of one-step self-etch systems (Adper Prompt L-Pop [AD] 3M ESPE; Xeno III [XE] Dentsply De Trey; iBond [iB] Heraeus Kulzer) under different application modes. Materials and methods: Dentin oclusal surfaces were exposed by grinding with 600-grit SiC paper. The adhesives were applied according to the manufacturer`s directions [MD], or with double application of the adhesive layer [DA] or following the manufacturer`s directions plus a hydrophobic resin layer coating [HL]. After applying the adhesive resins, composite crowns were built up incrementally. After 24-h water storage, the specimens were serially sectioned in ""x"" and ""y"" directions to obtain bonded sticks of about 0.8 mm 2 to be tested immediately [IM] or after 6 months of water storage [6M] at a crosshead speed of 0.5 mm/min. The data from each adhesive was analyzed by a two-way repeated measures ANOVA (mode of application vs. storage time) and Tukey`s test (alpha = 0.05). Results: The adhesives performed differently according to the application mode. The DA and HL either improved the immediate performance of the adhesive or did not differ from the MD. The resin-dentin bond strength values observed after 6 months were higher when a hydrophobic resin coat was used than compared to those values observed under the manufacturer`s directions. Conclusions: The double application of one-step self-etch system can be safety performed however the application of an additional hydrophobic resin layer can improve the immediate resin-dentin bonds and reduce the degradation of resin bonds over time. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical success of fiber posts has been attributed to their lower elastic modulus. The tested hypothesis was that fiber posts could lead to lower risk of post debonding and lower risk of root fracture, despite an increase in root stresses. Stress analyses were carried out with a 3D finite element model of a premolar restored with a metallic or a fiber post. Bonded and non-bonded post/cement interface conditions were simulated. We calculated risk-of-fracture indices by determining the highest principal stress values divided by the tensile strength. Shear stresses along the post/cement interface were analyzed for the bonded models. Compared with the premolar restored with a metallic post, the fiber post generated lower stresses along the interface and higher stresses in the root. However, with the fiber post, fracture was less likely to occur in the root, since its core and post fracture indices were higher.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of adding thickening agents on the penetration of a sunscreen benzophenone-3 through epidermal and a high-density polyethylene membrane was studied using both very thick (infinite dose) and thin tin use) applications. Contradictory results were obtained. Thickening agents retard skin penetration, in a manner consistent with a diffusional resistance in the formulation, when applied as an infinite dose. In contrast, when applied as in thin (in use) doses, thickening agents promote penetration, most likely through greater stratum corneum diffusivity arising from an enhanced hydration by the thicker formulations. The two key implications from this work are (i) a recognition of the danger in the potential extrapolation of infinite dosing to in use situations, and (ii) to recognize that thicker formulations may sometimes enhance the penetration of other topical agents when applied in use.