972 resultados para Blood volume expansion
Resumo:
The thesis aims to define further the biometric correlates in anisometropic eyes in order to provide a structural foundation for propositions concerning the development of ametropia.Biometric data are presented for 40 anisometropes and 40 isometropic controls drawn from Caucasian and Chinese populations.The principal finding was that the main structural correlate of myopia is an increase in axial rather than equatorial dimensions of the posterior globe. This finding has not been previously reported for in vivo work on humans. The computational method described in the thesis is a more accessible method for determination of eye shape than current imaging techniques such as magnetic resonance imaging or laser Doppler interferometry (LDI). Retinal contours derived from LDI and computation were shown to be closely matched. Corneal topography revealed no differences in corneal characteristics in anisometropic eyes, which supports the finding that anisometropia arises from differences in vitreous chamber depth.The corollary to axial expansion in myopia, that is retinal stretch in central regions of the posterior pole, was investigated by measurement of disc-to-fovea distances (DFD) using a scanning laser ophthalmoscope. DFD was found to increase with increased myopia, which demonstrates the primary contribution made by posterior central regions of the globe to axial expansion.The ocular pulse volume and choroidal blood flow, measured with the Ocular Blood Flow Tonograph, were found to be reduced in myopia; the reductions were found to be significantly correlated with vitreous chamber depth. The thesis includes preliminary data on whether the relationship arises from the influx of a blood bolus into eyes of different posterior volumes or represents actual differences in choroidal blood flow.The results presented in this thesis show the utility of computed retinal contour and demonstrate that the structural correlate of myopia is axial rather than equatorial expansion of the vitreous chamber. The technique is suitable for large population studies and its relative simplicity makes it feasible for longitudinal studies on the development of ametropia in, for example, children.
Resumo:
An HPLC method has been developed and validated for the rapid determination of mercaptopurine and four of its metabolites; thioguanine, thiouric acid, thioxanthine and methylmercaptopurine in plasma and red blood cells. The method involves a simple treatment procedure based on deproteinisation by perchloric acid followed by acid hydrolysis and heating for 45min at 100 degrees C. The developed method was linear over the concentration range studied with a correlation coefficient >0.994 for all compounds in both plasma and erythrocytes. The lower limits of quantification were 13, 14, 3, 2, 95pmol/8 x 10(8) RBCs and 2, 5, 2, 3, 20ng/ml plasma for thioguanine, thiouric acid, mercaptopurine, thioxanthine and methylmercaptopurine, respectively. The method described is selective and sensitive enough to analyse the different metabolites in a single run under isocratic conditions. Furthermore, it has been shown to be applicable for monitoring these metabolites in paediatric patients due to the low volume requirement (200microl of plasma or erythrocytes) and has been successfully applied for investigating population pharmacokinetics, pharmacogenetics and non-adherence to therapy in these patients.
Resumo:
Objective: To characterize the population pharmacokinetics of canrenone following administration of potassium canrenoate (K-canrenoate) in paediatric patients. Methods: Data were collected prospectively from 37 paediatric patients (median weight 2.9 kg, age range 2 days–0.85 years) who received intravenous K-canrenoate for management of retained fluids, for example in heart failure and chronic lung disease. Dried blood spot (DBS) samples (n = 213) from these were analysed for canrenone content and the data subjected to pharmacokinetic analysis using nonlinear mixed-effects modelling. Another group of patients (n = 16) who had 71 matching plasma and DBS samples was analysed separately to compare canrenone pharmacokinetic parameters obtained using the two different matrices. Results: A one-compartment model best described the DBS data. Significant covariates were weight, postmenstrual age (PMA) and gestational age. The final population models for canrenone clearance (CL/F) and volume of distribution (V/F) in DBS were CL/F (l/h) = 12.86 × (WT/70.0)0.75 × e [0.066 × (PMA - 40]) and V/F (l) = 603.30 × (WT/70) × (GA/40)1.89 where weight is in kilograms. The corresponding values of CL/F and V/F in a patient with a median weight of 2.9 kg are 1.11 l/h and 20.48 l, respectively. Estimated half-life of canrenone based on DBS concentrations was similar to that based on matched plasma concentrations (19.99 and 19.37 h, respectively, in 70 kg patient). Conclusion: The range of estimated CL/F in DBS for the study population was 0.12–9.62 l/h; hence, bodyweight-based dosage adjustment of K-canrenoate appears necessary. However, a dosing scheme that takes into consideration both weight and age (PMA/gestational age) of paediatric patients seems more appropriate.
Resumo:
In the Light Controlled Factory part-to-part assembly and reduced weight will be enabled through the use of predictive fitting processes; low cost high accuracy reconfigurable tooling will be made possible by active compensation; improved control will allow accurate robotic machining; and quality will be improved through the use of traceable uncertainty based quality control throughout the production system. A number of challenges must be overcome before this vision will be realized; 1) controlling industrial robots for accurate machining; 2) compensation of measurements for thermal expansion; 3) Compensation of measurements for refractive index changes; 4) development of Embedded Metrology Tooling for in-tooling measurement and active tooling compensation; and 5) development of Software for the Planning and Control of Integrated Metrology Networks based on Quality Control with Uncertainty Evaluation and control systems for predictive processes. This paper describes how these challenges are being addressed, in particular the central challenge of developing large volume measurement process models within an integrated dimensional variation management (IDVM) system.
Resumo:
Background/Aims: Extracellular vesicles (EVs) are spherical fragments of cell membrane released from various cell types under physiological as well as pathological conditions. Based on their size and origin, EVs are classified as exosome, microvesicles (MVs) and apoptotic bodies. Recently, the release of MVs from human red blood cells (RBCs) under different conditions has been reported. MVs are released by outward budding and fission of the plasma membrane. However, the outward budding process itself, the release of MVs and the physical properties of these MVs have not been well investigated. The aim of this study is to investigate the formation process, isolation and characterization of MVs released from RBCs under conditions of stimulating Ca2+ uptake and activation of protein kinase C. Methods: Experiments were performed based on single cell fluorescence imaging, fluorescence activated cell sorter/flow cytometer (FACS), scanning electron microscopy (SEM), atomic force microscopy (AFM) and dynamic light scattering (DLS). The released MVs were collected by differential centrifugation and characterized in both their size and zeta potential. Results: Treatment of RBCs with 4-bromo-A23187 (positive control), lysophosphatidic acid (LPA), or phorbol-12 myristate-13 acetate (PMA) in the presence of 2 mM extracellular Ca2+ led to an alteration of cell volume and cell morphology. In stimulated RBCs, exposure of phosphatidylserine (PS) and formation of MVs were observed by using annexin V-FITC. The shedding of MVs was also observed in the case of PMA treatment in the absence of Ca2+, especially under the transmitted bright field illumination. By using SEM, AFM and DLS the morphology and size of stimulated RBCs, MVs were characterized. The sizes of the two populations of MVs were 205.8 ± 51.4 nm and 125.6 ± 31.4 nm, respectively. Adhesion of stimulated RBCs and MVs was observed. The zeta potential of MVs was determined in the range from - 40 mV to - 10 mV depended on the solutions and buffers used. Conclusion: An increase of intracellular Ca2+ or an activation of protein kinase C leads to the formation and release of MVs in human RBCs.
Resumo:
Three-Dimensional (3-D) imaging is vital in computer-assisted surgical planning including minimal invasive surgery, targeted drug delivery, and tumor resection. Selective Internal Radiation Therapy (SIRT) is a liver directed radiation therapy for the treatment of liver cancer. Accurate calculation of anatomical liver and tumor volumes are essential for the determination of the tumor to normal liver ratio and for the calculation of the dose of Y-90 microspheres that will result in high concentration of the radiation in the tumor region as compared to nearby healthy tissue. Present manual techniques for segmentation of the liver from Computed Tomography (CT) tend to be tedious and greatly dependent on the skill of the technician/doctor performing the task. ^ This dissertation presents the development and implementation of a fully integrated algorithm for 3-D liver and tumor segmentation from tri-phase CT that yield highly accurate estimations of the respective volumes of the liver and tumor(s). The algorithm as designed requires minimal human intervention without compromising the accuracy of the segmentation results. Embedded within this algorithm is an effective method for extracting blood vessels that feed the tumor(s) in order to plan effectively the appropriate treatment. ^ Segmentation of the liver led to an accuracy in excess of 95% in estimating liver volumes in 20 datasets in comparison to the manual gold standard volumes. In a similar comparison, tumor segmentation exhibited an accuracy of 86% in estimating tumor(s) volume(s). Qualitative results of the blood vessel segmentation algorithm demonstrated the effectiveness of the algorithm in extracting and rendering the vasculature structure of the liver. Results of the parallel computing process, using a single workstation, showed a 78% gain. Also, statistical analysis carried out to determine if the manual initialization has any impact on the accuracy showed user initialization independence in the results. ^ The dissertation thus provides a complete 3-D solution towards liver cancer treatment planning with the opportunity to extract, visualize and quantify the needed statistics for liver cancer treatment. Since SIRT requires highly accurate calculation of the liver and tumor volumes, this new method provides an effective and computationally efficient process required of such challenging clinical requirements.^
Resumo:
Decellularized adipose tissue (DAT) is a promising biomaterial for soft tissue regeneration, and it provides a highly conducive microenvironment for human adipose-derived stem/stromal cell (ASC) attachment, proliferation, and adipogenesis. This thesis focused on developing techniques to fabricate 3-D bioscaffolds from enzymatically-digested DAT as platforms for ASC culture and delivery in adipose tissue engineering and large-scale ASC expansion. Initial work investigated chemically crosslinked microcarriers fabricated from pepsin-digested DAT as injectable adipo-inductive substrates for ASCs. DAT microcarriers highly supported ASC adipogenesis compared to gelatin microcarriers in a CELLSPIN system, as confirmed by glycerol-3-phosphate dehydrogenase (GPDH) enzyme activity, lipid accumulation, and endpoint RT-PCR. ASCs cultured on DAT microcarriers in proliferation medium also had elevated PPARγ, C/EBPα, and LPL expression which suggested adipo-inductive properties. In vivo testing of the DAT microcarriers exhibited stable volume retention and enhanced cellular infiltration, tissue remodeling, and angiogenesis. Building from this work, non-chemically crosslinked porous foams and bead foams were fabricated from α-amylase-digested DAT for soft tissue regeneration. Foams were stable and strongly supported ASC adipogenesis based on GPDH activity and endpoint RT-PCR. PPARγ, C/EBPα, and LPL expression in ASCs cultured on the foams in proliferation media indicated adipo-inductive properties. Foams with Young’s moduli similar to human fat also influenced ASC adipogenesis by enhanced GPDH activity. In vivo adipogenesis accompanied by a potent angiogenic response and rapid resorption showed their potential use in wound healing applications. Finally, non-chemically crosslinked porous microcarriers synthesized from α-amylase-digested DAT were investigated for ASC expansion. DAT microcarriers remained stable in culture and supported significantly higher ASC proliferation compared to Cultispher-S microcarriers in a CELLSPIN system. ASC immunophenotype was preserved for all expanded groups, with reduced adhesion marker expression under dynamic conditions. DAT microcarrier expansion upregulated ASC expression of early adipogenic (PPARγ, LPL) and chondrogenic (COMP) markers without inducing a mature phenotype. DAT microcarrier expanded ASCs also showed similar levels of adipogenesis and osteogenesis compared to Cultispher-S despite a significantly higher population fold-change, and had the highest level of chondrogenesis among all groups. This study demonstrates the promising use of DAT microcarriers as a clinically relevant strategy for ASC expansion while maintaining multilineage differentiation capacity.
Resumo:
The soybean is the grain in which greater food dependency has Mexico, reason why as of 2008, the government has promoted his culture, granting excellent subsidies, as much to producers as to buyers of the grain, thus contributing to a recent process of expansion in certain states, as it happens in Campeche. The objetive of this article is the analysis of the characteristics and effects of those supports, as well as of the rest of factors that until today they have taken to the producers of the mentioned state to initiate or to expand the cultivation of the soybean. The findings of the investigation reveal that although the producers have improved their levels of income, the process is vulnerable, as it depends on variables like the governmental supports, the international prices of the soybean and exchange rate. Although the study of the negative effects of genetically modified soybeans (GM) in other areas (environment, biodiversity, deforestation, human and animal health) is not the purpose of this investigation, some information will be provided, as on the conflict between soybean producers and beekeepers in the state of Campeche.
Resumo:
AZEVEDO, George Dantas de et al. Raloxifene therapy does not affect uterine blood flow in postmenopausal women: a transvaginal Doppler study. Maturitas, Amsterdam, v.47, n.3, p.195-200, 2004
Resumo:
Rationale Self-titration is well documented in the tobacco literature. The extent to which ecigarette users (vapers) self-titrate is unknown. Objective This study explored the effects of high and low nicotine strength liquid on puffing topography, nicotine delivery and subjective effects in experienced vapers. Methods Eleven experienced male vapers completed 60 minutes of ad libitum vaping under low (6 mg/mL) and high (24 mg/mL) nicotine liquid conditions in two separate sessions. Measurements included: puffing topography (puff number, puff duration, volume of liquid consumed); and changes in: plasma nicotine levels, craving, withdrawal symptoms, selfreported hit, satisfaction and adverse effects. Results Liquid consumption and puff number were higher, and puff duration longer, in the low nicotine strength condition (all ps < 0.01). The mean difference in nicotine boost from baseline in the low condition was 8.59 (7.52) ng/mL, 16.99 (11.72) ng/mL and 22.03 (16.19) ng/mL at 10, 30 and 60 minutes respectively. Corresponding values for the high condition were 33.77 (34.88) ng/mL, 35.48 (28.31) ng/mL and 43.57 (34.78) ng/mL (ps < 0.05). There were no statistically significant differences between conditions in self-reported craving, withdrawal symptoms, satisfaction, hit or adverse effects. Conclusions Vapers engaged in compensatory puffing with lower nicotine strength liquid, doubling their consumption. Whilst compensatory puffing was sufficient to reduce craving and withdrawal discomfort, self-titration was incomplete with significantly higher plasma nicotine levels in the high condition.
Resumo:
A three-dimensional finite volume, unstructured mesh (FV-UM) method for dynamic fluid–structure interaction (DFSI) is described. Fluid structure interaction, as applied to flexible structures, has wide application in diverse areas such as flutter in aircraft, wind response of buildings, flows in elastic pipes and blood vessels. It involves the coupling of fluid flow and structural mechanics, two fields that are conventionally modelled using two dissimilar methods, thus a single comprehensive computational model of both phenomena is a considerable challenge. Until recently work in this area focused on one phenomenon and represented the behaviour of the other more simply. More recently, strategies for solving the full coupling between the fluid and solid mechanics behaviour have been developed. A key contribution has been made by Farhat et al. [Int. J. Numer. Meth. Fluids 21 (1995) 807] employing FV-UM methods for solving the Euler flow equations and a conventional finite element method for the elastic solid mechanics and the spring based mesh procedure of Batina [AIAA paper 0115, 1989] for mesh movement. In this paper, we describe an approach which broadly exploits the three field strategy described by Farhat for fluid flow, structural dynamics and mesh movement but, in the context of DFSI, contains a number of novel features: a single mesh covering the entire domain, a Navier–Stokes flow, a single FV-UM discretisation approach for both the flow and solid mechanics procedures, an implicit predictor–corrector version of the Newmark algorithm, a single code embedding the whole strategy.
Resumo:
AZEVEDO, George Dantas de et al. Raloxifene therapy does not affect uterine blood flow in postmenopausal women: a transvaginal Doppler study. Maturitas, Amsterdam, v.47, n.3, p.195-200, 2004
Resumo:
Background: Thrombocytopenia has been shown to predict mortality. We hypothesize that platelet indices may be more useful prognostic indicators. Our study subjects were children one month to 14 years old admitted to our hospital. Aim: To determine whether platelet count, plateletcrit (PCT), mean platelet volume (MPV) and platelet distribution width (PDW) and their ratios can predict mortality in hospitalised children. Methods: Children who died during hospital stay were the cases. Controls were age matched children admitted contemporaneously. The first blood sample after admission was used for analysis. Receiver operating characteristic (ROC) curve was used to identify the best threshold for measured variables and the ratios studied. Multiple regression analysis was done to identify independent predictors of mortality. Results: Forty cases and forty controls were studied. Platelet count, PCT and the ratios of MPV/Platelet count, MPV/PCT, PDW/Platelet count, PDW/PCT and MPV x PDW/Platelet count x PCT were significantly different among children who survived compared to those who died. On multiple regression analysis the ratio of MPV/PCT, PDW/Platelet count and MPV/ Platelet count were risk factors for mortality with an odds ratio of 4.31(95% CI, 1.69-10.99), 3.86 (95% CI, 1.53-9.75), 3.45 (95% CI, 1.38-8.64) respectively. In 67% of the patients who died MPV/PCT ratio was above 41.8 and PDW/Platelet count was above 3.86. In 65% of patients who died MPV/Platelet count was above 3.45. Conclusion: The MPV/PCT, PDW/Platelet count and MPV/Platelet count, in the first sample after admission in this case control study were predictors of mortality and could predict 65% to 67% of deaths accurately.
Resumo:
Objectives: To investigate opposition to standardised tobacco packaging in the UK. To increase understanding of how transnational corporations are adapting to changes in their access to policymakers precipitated by Article 5.3 of the Framework Convention on Tobacco Control (FCTC). Design: Case study web-based documentary analysis, using NVivo V.10. Examination of relationships between opponents of standardised packaging and transnational tobacco companies (TTCs) and of the volume, nature, transparency and timing of their activities. Setting: UK standardised packaging policy debate 2011-2013. Participants: Organisations selected on basis of opposition to, or facilitation thereof, standardised tobacco packaging in the UK; 422 associated documents. Results: Excluding tobacco manufacturing and packaging companies (n=12), 109 organisations were involved in opposing standardised packaging, 82 (75%) of which had a financial relationship with 1 or more TTC. These 82 organisations (43 actively opposing the measure, 39 facilitating opposition) were responsible for 60% of the 404 activities identified, including the majority of public communications and research production. TTCs were directly responsible for 28% of total activities, predominantly direct lobbying, but also financially underwrote third party research, communication, mass recruitment and lobbying. Active organisations rarely reported any financial relationship with TTCs when undertaking opposition activities. Conclusions: The multifaceted opposition to standardised packaging was primarily undertaken by third parties with financial relationships with major tobacco manufacturers. Low levels of transparency regarding these links created a misleading impression of diverse and widespread opposition. Countries should strengthen implementation of Article 5.3 of the FCTC by systematically requiring conflict of interest declarations from all organisations participating in political or media debates on tobacco control.
Resumo:
Oscillometric blood pressure (BP) monitors are currently used to diagnose hypertension both in home and clinical settings. These monitors take BP measurements once every 15 minutes over a 24 hour period and provide a reliable and accurate system that is minimally invasive. Although intermittent cuff measurements have proven to be a good indicator of BP, a continuous BP monitor is highly desirable for the diagnosis of hypertension and other cardiac diseases. However, no such devices currently exist. A novel algorithm has been developed based on the Pulse Transit Time (PTT) method, which would allow non-invasive and continuous BP measurement. PTT is defined as the time it takes the BP wave to propagate from the heart to a specified point on the body. After an initial BP measurement, PTT algorithms can track BP over short periods of time, known as calibration intervals. After this time has elapsed, a new BP measurement is required to recalibrate the algorithm. Using the PhysioNet database as a basis, the new algorithm was developed and tested using 15 patients, each tested 3 times over a period of 30 minutes. The predicted BP of the algorithm was compared to the arterial BP of each patient. It has been established that this new algorithm is capable of tracking BP over 12 minutes without the need for recalibration, using the BHS standard, a 100% improvement over what has been previously identified. The algorithm was incorporated into a new system based on its requirements and was tested using three volunteers. The results mirrored those previously observed, providing accurate BP measurements when a 12 minute calibration interval was used. This new system provides a significant improvement to the existing method allowing BP to be monitored continuously and non-invasively, on a beat-to-beat basis over 24 hours, adding major clinical and diagnostic value.