912 resultados para wire


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The foraging strategies of two natural enemies of the peach-potato aphid Myzus persicae: the seven-spot ladybird Coccinella septempunctata and the parasitoid wasp Diaeretiella rapae, were investigated. Specifically the roles of plant semiochemicals in the location of plants infested with M. persicae by these natural enemies were examined. I investigated the olfactory responses of female C. septempunctata to volatiles collected from M. persicae and four Brassica cultivars; Brassica rapa, B. juncea, B. napus cultivar ‘Apex’ and B. napus cultivar ‘Courage’ and wild-type Arabidopsis thaliana that were: undamaged, previously infested by M. persicae and infested with M. persicae. C. septempunctata showed no attraction to volatiles from M. persicae alone. C. septempunctata significantly changed its searching behaviour in response to plant volatiles from B. rapa, B. napus cv. ‘Apex’ and Arabidopsis infested with M. persicae. C. septempunctata was also found to display a significant turning bias when foraging on a branching horizontal wire stem. A model was developed to investigate how turning biases affect the foraging efficiency of C. septempunctata in dichotomous branched environments. Simulations using this model indicated that turning biases could potentially increase searching efficiency. D. rapae showed a significant preference for volatiles from M. persicae infested wild-type Arabidopsis but no preference to volatiles from M. persicae alone or M. persicae honeydew. Volatile emissions by Arabidopsis were shown to be localised to the area of aphid-infestation rather than systemic. Using gas chromatography plants infested with M. persicae were shown to emit a quantitatively different volatile blend than undamaged plants. In experiments with jasmonate mutants of Arabidopsis the jasmonate (octadecanoid) wound response pathway was implicated as being important for the production of M. persicae induced volatiles, attractive to D. rapae. Other wound response pathways were also found to be involved in the production of the full blend of M. persicae induced volatiles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article contrasts the sense in which those whom Bernard Williams called ‘political realists’ and John Rawls are committed to the idea that political philosophy has to be distinctively political. Distinguishing the realist critique of political moralism from debates over ideal and non-ideal theory, it is argued that Rawls is more realist than many realists realise, and that realists can learn more about how to make a distinctively political vision of how our life together should be organised from his theorising, although it also points to a worrying tendency among Rawlsians to reach for inappropriately moralised arguments. G. A. Cohen’s advocacy of socialism and the second season of HBO’s The Wire are used as examples to illustrate these points.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background/Aims: The purpose of this study was to examine the cardiovascular effects of long-term ouabain treatment at different time points. Methods: Systolic blood pressure (SBP) was measured by tail-cuff method in male Wistar rats treated with ouabain (approx. 8.0 mu g.day(-1)) or vehicle for 5, 10 and 20 weeks. Afterwards, vascular function was assessed in mesenteric resistance arteries (MRA) using a wire myograph. ROS production and COX-1 and COX-2, TNF-alpha, and IL-6 protein expression were investigated. Results: SBP was increased by ouabain treatment up to the 6th week and remained stable until the 20th week. However, noradrenaline-induced contraction increased only in MRA in rats treated with ouabain for 20 weeks. NOS inhibition and endothelium removal increased the noradrenaline response, but to a smaller magnitude in MRA in the ouabain group. Moreover, inhibition of COX-2 or incubation with superoxide dismutase restores noradrenaline-induced contraction in the 20-week ouabain group to control levels. ROS production as well as COX-2, IL-6 and TNF-alpha protein expression increased in MRA in this group. Conclusion: Although ouabain treatment induced hypertension in all groups, a larger noradrenaline induced contraction was observed over 20 weeks of treatment. This vascular dysfunction was related to COX-2-derived prostanoids and oxidative stress, increased pro-inflammatory cytokines and reduced NO bioavailability. Copyright (C) 2011 S. Karger AG, Basel

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We explore a method for constructing two-dimensional area-preserving, integrable maps associated with Hamiltonian systems, with a given set of fixed points and given invariant curves. The method is used to find an integrable Poincare map for the field lines in a large aspect ratio tokamak with a poloidal single-null divertor. The divertor field is a superposition of a magnetohydrodynamic equilibrium with an arbitrarily chosen safety factor profile, with a wire carrying an electric current to create an X-point. This integrable map is perturbed by an impulsive perturbation that describes non-axisymmetric magnetic resonances at the plasma edge. The non-integrable perturbed map is applied to study the structure of the open field lines in the scrape-off layer, reproducing the main transport features obtained by integrating numerically the magnetic field line equations, such as the connection lengths and magnetic footprints on the divertor plate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the design and operation of a device for ac magnetic susceptibility measurements that can operate down to 1 mK. The device, a modification of the standard mutual inductance bridge, is designed with detailed consideration of the thermalization and optimization of each element. First, in order to reduce local heating, the primary coil is made with superconducting wire. Second, a low-temperature transformer which is thermally anchored to the mixing chamber of a dilution refrigerator, is used to match the output of the secondary coil to a high-sensitivity bridge detector. The careful thermal anchoring of the secondary coil and the matching transformer is required to reduce the overall noise temperature and maximize sensitivity. The sample is immersed in liquid (3)He to minimize the Kapitza thermal resistance. The magnetic susceptibility of several magnetic compounds, such as the well-known spin gap compound NiCl(2)-4SC(NH(2))(2) and other powdered samples, have been successfully measured to temperatures well below 10 mK.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We study the thermopower, thermal conductance, electric conductance and the thermoelectric figure of merit for a gate-defined T-shaped single quantum dot (QD). The QD is solved in the limit of strong Coulombian repulsion U -> infinity, inside the dot, and the quantum wire is modeled on a tight-binding linear chain. We employ the X-boson approach for the Anderson impurity model to describe the localized level within the quantum dot. Our results are in qualitative agreement with recent experimental reports and other theoretical researches for the case of a quantum dot embedded into a conduction channel, employing analogies between the two systems. The results for the thermopower sign as a function of the gate voltage (associated with the quantum dot energy) are in agreement with a recent experimental result obtained for a suspended quantum dot. The thermoelectric figure of merit times temperature results indicates that, at low temperatures and in the crossover between the intermediate valence and Kondo regimes, the system might have practical applicability in the development of thermoelectric devices. (c) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We show that the conductance of a quantum wire side-coupled to a quantum dot, with a gate potential favoring the formation of a dot magnetic moment, is a universal function of the temperature. Universality prevails even if the currents through the dot and the wire interfere. We apply this result to the experimental data of Sato et al. (Phys. Rev. Lett., 95 (2005) 066801). Copyright (C) EPLA, 2009

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hydrogen peroxide was determined in oral antiseptic and bleach samples using a flow-injection system with amperometric detection. A glassy carbon electrode modified by electrochemical deposition of ruthenium oxide hexacyanoferrate was used as working electrode and a homemade Ag/AgCl (saturated KCl) electrode and a platinum wire were used as reference and counter electrodes, respectively. The electrocatalytic reduction process allowed the determination of hydrogen peroxide at 0.0 V. A linear relationship between the cathodic peak current and concentration of hydrogen peroxide was obtained in the range 10-5000 mu mol L(-1) with detection and quantification limits of 1.7 (S/N = 3) and 5.9 (S/N = 10) mu mol L(-1), respectively. The repeatability of the method was evaluated using a 500 mu mol L(-1) hydrogen peroxide solution, the value obtained being 1.6% (n = 14). A sampling rate of 112 samples h(-1) was achieved at optimised conditions. The method was employed for the quantification of hydrogen peroxide in two commercial samples and the results were in agreement with those obtained by using a recommended procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A laboratory offset press has been developed over the last five years at PAPRO for testing print qualityon newsprint, as at present, there is no good way for the mills to test this issue. In this project a comparisonhas been made between a laboratory offset press and a commercial press to see if the laboratoryoffset press can be used as a reliable test method or if a further development is needed.To evaluate the method, similar papers have been printed in both presses and compared using imageanalysis techniques. All together eighteen samples were tested which is enough to give comparableresults. The print quality showed a high variation, the values from the laboratory offset press and thecommercial press were not following the same trends. At present time the laboratory offset press needsome further development before it can be used as a reliable test method for halftone prints. Even sosome conclusions were made.The newsprint that has been used came from Norske Skog Tasman Mill (Kawerau), since the otheraim of this project was to do a repeatability study of their three existing paper machines to distinguishpossible differences in the production. The paper samples were taken from each paper machine on sixdifferent dates to give a representative result. This also gave the opportunity to compare the machinesbetween themselves. Comparison between the machines shows that the wire side gives a better andmore even result than the topside on the prints from the laboratory offset press. According to the resultfrom the commercial press the wire side shows a higher degree of variability. Samples from papermachine 2 and 3 were less variable and had the lowest standard deviation of grey level for solid areas.This suggests that newsprints from PM 2 and PM 3 give a more even print quality with a better inkcoverage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The report examines the factors which may be a contributing cause to the problems that are present when ferritic stainless steel are eddy current tested in a warm condition. The work is carried out at Fagersta Stainless AB in Fagersta which manufactures stainless steel wire. In the rolling mill there is an eddy current equipment for detection of surface defects on the wire. The ferritic stainless steels cause a noise when testing and this noise complicates the detection of defects.Because of this, a study was made of how the noise related to factors such as steel grade, temperature, size and velocity. By observing the signal and with the possibilities to change the equipment settings the capability to let a signal filter reduce the noise level were evaluated. Theories about the material's physical properties have also been included, mainly the magnetic properties, electrical conductivity and the material's tendency to oxidize.Results from the tests show that a number of factors do not affect the inductive test significantly and to use a filter to reduce the noise level does not seem to be a viable option. The level of noise does not relate to the presence of superficial particles in form of oxides.The ferritic stainless steels showed some difference in noise level. Which noise level there was did match well with the steels probability for a precipitation of a second phase, and precipitation of austenite may in this case contribute to noise when using an eddy current instrument.The noise is probably due to some physical material property that varies within the thread.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Very often defects are present in rolled products. For wire rods, defects are very deleterious since the wire rods are generally used directly in various applications. For this reason, the market nowadays requires wire rods to be completely defect-free. Any wire with defects must be rejected as scrap which is very costly for the production mill. Thus, it is very important to study the formation and evolution of defects during wire rod rolling in order to better understand and minimize the problem, at the same time improving quality of the wire rods and reducing production costs. The present work is focused on the evolution of artificial defects during rolling. Longitudinal surface defects are studied during shape rolling of an AISI M2 high speed steel and a longitudinal central inner defect is studied in an AISI 304L austenitic stainless steel during ultra-high-speed wire rod rolling. Experimental studies are carried out by rolling short rods prepared with arteficial defects. The evolution of the defects is characterised and compared to numerical analyses. The comparison shows that surface defects generally reduce quicker in the experiments than predicted by the simulations whereas a good agreement is generally obtained for the central defect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis focuses on the tribological performance of tool surfaces in two steel working operations, namely wire drawing and hot rolling. In all forming operations dimensions and surface finish of the products are of utmost importance. Forming basically includes three parts – forming conditions excluded – that may be changed; work material, tool and (possibly) lubricant. In the interface between work material and tool, the conditions are very aggressive with – generally or locally – high temperatures and pressures. The surfaces will be worn in various ways and this will change the conditions in the process. Consequently, the surface finish as well as the dimensions of the formed product may change and in the end, the product will not fulfil the requirements of the customer. Therefore, research and development in regard to wear, and consequently tribology, of the forming tools is of great interest. The investigations of wire drawing dies focus on coating adhesion/cohesion, surface characteristics and material transfer onto the coated steel both in laboratory scale as well as in the wire drawing process. Results show that it in wire drawing is possible to enhance the tribological performance of drawing dies by using a lubricant together with a steel substrate coated by a polished, dual-layer coating containing both hard and friction-lowering layers. The investigations of hot rolling work rolls focus on microstructure and hardness as well as cracking- and surface characteristics in both laboratory scale and in the hot strip mill. Results show that an ideal hot work roll material should be made up of a matrix with high hardness and a large amount of complex, hard carbides evenly distributed in the microstructure. The surface failure mechanisms of work rolls are very complex involving plastic deformation, abrasive wear, adhesive wear, mechanical and thermal induced cracking, material transfer and oxidation. This knowledge may be used to develop new tools with higher wear resistance giving better performance, lower costs and lower environmental impact.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução. A endotelina-1, o mais potente vasoconstritor endógeno, atua através de dois receptores de afinidades distintas, conhecidos como ETA e ETB. Os receptores ETA estão localizados predominantemente na musculatura lisa vascular e são os principais mediadores do efeito vasoconstritor da endotelina-1. Diversos estudos demonstraram que a endotelina-1 exerce um papel importante na manutenção do tônus arterial basal. Entretanto, a contribuição da endotelina-1 para o tônus coronariano basal em seres humanos, especialmente em coronárias com lesões ateroscleróticas, permanece alvo de interesse. Objetivos. Os objetivos deste estudo foram avaliar a contribuição da endotelina-1 no tônus coronariano epicárdico e na microcirculação em coronárias livres de lesões obstrutivas e em coronárias com lesões ateroscleróticas e comparar o método da contagem TIMI com o Doppler intracoronário na detecção de alterações do fluxo sangüíneo em resposta à adenosina. Métodos. Um total de 16 pacientes, sendo oito destes no grupo com coronárias livres de lesões obstrutivas e oito pacientes com lesões coronarianas obstrutivas, foram incluídos neste estudo. Todos pacientes receberam a infusão seletiva intracoronária de BQ-123, um inibidor específico dos receptores ETA da endotelina-1, durante 60 minutos. Adenosina e nitroglicerina foram administradas em bolus no tronco da coronária esquerda. O efeito do BQ-123 no diâmetro coronário epicárdico foi avaliado por angiografia quantitativa realizada a cada 15 minutos ao longo da infusão da droga. O efeito na microcirculação coronária foi avaliado por variações no fluxo sangüíneo medido por guia-Doppler e pelo método da contagem TIMI. Resultados. A infusão de BQ-123 resultou em aumento de 7% do diâmetro coronário e de 19% no fluxo sangüíneo volumétrico em pacientes com artérias livres de lesões obstrutivas (P < 0,001 para comparação com basal). O aumento do calibre do vaso ocorreu de forma progressiva e uniforme ao longo do vaso. Os pacientes com lesão aterosclerótica apresentaram um aumento de 16% (P < 0,001 para comparação com artérias livres de lesões obstrutivas) no diâmetro coronário e 28% no local da estenose. A velocidade do fluxo sangüíneo em coronárias livres de lesões obstrutivas não se alterou significativamente tanto na medida por Doppler como pelo método de contagem TIMI. Houve uma correlação de 0,67 (P < 0,05) entre o método da contagem TIMI e o Doppler para detecção de alterações na velocidade do fluxo sangüíneo em resposta à adenosina. Conclusões. A infusão seletiva intracoronária do inibidor específico dos receptores ETA da endotelina-1 em seres humanos pode ser feita de maneira segura. A endotelina-1 exerce um papel importante na manutenção do tônus coronariano basal em artérias livres de lesões obstrutivas, sendo responsável pela quase totalidade do tônus constritor aumentado presente em coronárias com lesões ateroscleróticas. O método da contagem TIMI apresenta uma boa correlação com o Doppler para medida do fluxo sangüíneo em condições de hiperêmia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os experimentos tiveram como objetivo determinar a taxa de eclosão dos embriões vitrificados em volumes diferentes de 9,0 M de etileno glicol. Simultaneamente, testou-se dois procedimentos de estocagem dos fios de teflon, denominados caixa de aço inoxidável e globete/raque. No experimento I, os 881 embriões coletados foram distribuídos em 4 tratamentos: tratamento 1 (T1= controle): 307 embriões foram cultivados in vitro em meio PBSm, acrescido de 0,4% de BSA; tratamento 2 (T2): 292 embriões foram expostos à solução de glicerol 10% acrescida de 0,4% de BSA, envasados em palhetas de 0,25 mL e submetidos ao congelamento pelo método rápido em Biocool; tratamento 3 (T3): 138 embriões foram expostos durante 2 minutos à solução de desidratação (10% de EG + 6% BSA em PBSm) e então transferidos para a solução de vitrificação (50% de EG + 6% de BSA em PBSm), onde permaneceram por 30 segundos e foram colocados em volume de 1 μL no interior de um fio de teflon, medindo 0,4 mm de diâmetro, 2,0 cm de comprimento e 0,05 mm de espessura. Os fios foram acondicionados em uma caixa de aço inoxidável para serem armazenados em nitrogênio líquido; tratamento 4 (T4): 144 embriões foram expostos à solução de desidratação (10% de EG + 6% BSA em PBSm) e após 2 minutos, foram transferidos para a solução de vitrificação (50% de EG + 6% BSA em PBSm), onde permaneceram por 30 segundos, sendo após transferidos para um volume de 1 μL no interior do fio de teflon. Os fios de teflon foram estocados em globetes unidos às raques e mantidos em nitrogênio líquido. Após o aquecimento, os embriões foram cultivados em PBSm suplementado com 0,4% de BSA. As taxas de eclosão embrionária observadas foram: T1=76,29% (245/307); T2=41,05% (117/292); T3=37,98% (54/138) e T4=26,78% (37/144). No segundo experimento, 747 embriões foram distribuídos em 3 tratamentos: tratamento 1 (T1= controle): 80 embriões foram cultivados in vitro em meio KSOM acrescido de 0,4% de BSA; tratamento 2 (T2): 334 embriões expostos em solução de glicerol 10% acrescida de 0,4% de BSA, foram envasados em palhetas de 0,25 mL e submetidos ao congelamento pelo método rápido em Biocool; tratamento 3 (T3): 333 blastocistos foram expostos durante 2 minutos à solução de desidratação (10% de EG + 0,4% BSA em PBSm) e então transferidos para tubos eppendorf de 2,0 mL em contato com a solução de vitrificação (50% de EG + 0,4% BSA em PBSm). Após o cultivo in vitro, as taxas de eclosão embrionária observadas nos 3 tratamentos foram respectivamente: 88,75% (71/80), 40,44% (141/334) e 19,70% (66/333). Baseado nesses resultados conclui-se que embriões Mus domesticus domesticus submetidos à técnica de vitrificação após exposição à solução de 9,0 M de etileno glicol e envase em fios de teflon assegurou índices satisfatórios de sobrevivência embrionária. As taxas de sobrevivência dos embriões Mus domesticus domesticus foi independente do procedimento de estocagem em botijão de nitrogênio líquido. A vitrificação em solução de 9,0 M de etileno glicol com envase em tubos eppendorf não foi eficiente para promover altas taxas de sobrevivência embrionária, mas proporcionou segurança biológica aos embriões, durante o armazenamento.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since the 1980s, different devices based on superelastic alloys have been developed to fulfill orthodontic applications. Particularly in the last decades several researches have been carried out to evaluate the mechanical behavior of Ni-Ti alloys, including their tensile, torsion and fatigue properties. However, studies regarding the dependence of elastic properties on residence time of Ni-Ti wires in the oral cavity are scarce. Such approach is essential since metallic alloys are submitted to mechanical stresses during orthodontic treatment as well as pH and temperature fluctuations. The goal of the present contribution is to provide elastic stress-strain results to guide the orthodontic choice between martensitic thermal activated and austenitic superelastic Ni-Ti alloys. From the point of view of an orthodontist, the selection of appropriate materials and the correct maintenance of the orthodontic apparatus are essential needs during clinical treatment. The present work evaluated the elastic behavior of Ni-Ti alloy wires with diameters varying from 0.014 to 0.020 inches, submitted to hysteresis tensile tests with 8% strain. Tensile tests were performed after periods of use of 1, 2 and 3 months in the oral cavity of patients submitted to orthodontic treatment. The results from the hysteresis tests allowed to exam the strain range covered by isostress lines upon loading and unloading, as well as the residual strain after unloading for both superelastic and thermal activated Ni-Ti wires. Superelastic Ni-Ti wires exhibited higher load isostress values compared to thermal activated wires. It was found that such differences in the load isostress values can increase with increasing residence time.