909 resultados para performance measurement sourcing


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Although 17β-estradiol (E2) deficiency has been linked to the development of osteoarthritis (OA) in middle-aged women, there are few studies relating other estrogens and estrogen metabolites (EMs) to this condition. We developed a high-performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) method to measure the levels of six EMs (i.e., estrone, E2, estriol, 2-hydroxyestrone, 2-hydroxyestradiol, and 16a-hydroxyestrone) in healthy pre- and postmenopausal women and women with OA. This method had a precision ranging from 1.1 to 3.1% and a detection limit ranging from 10 to 15 pg. Compared to healthy women, serum-free E2 was lower in the luteal and postmenopausal phases in women with OA, and total serum E2 was lower in postmenopausal women with OA. Moreover, compared to healthy women, total serum 2-hydroxyestradiol was higher in postmenopausal women with OA and total serum 2-hydroxyestrone was lower in both the luteal and follicular phases in women with OA. In conclusion, our HPLC-ESI-MS/MS method allowed the measurement of multiple biochemical targets in a single assay, and, given its increased cost-effectiveness, simplicity, and speed relative to previous methods, this method is suitable for clinical studies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In the accounting literature, interaction or moderating effects are usually assessed by means of OLS regression and summated rating scales are constructed to reduce measurement error bias. Structural equation models and two-stage least squares regression could be used to completely eliminate this bias, but large samples are needed. Partial Least Squares are appropriate for small samples but do not correct measurement error bias. In this article, disattenuated regression is discussed as a small sample alternative and is illustrated on data of Bisbe and Otley (in press) that examine the interaction effect of innovation and style of use of budgets on performance. Sizeable differences emerge between OLS and disattenuated regression

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents the performance of the ATLAS muon reconstruction during the LHC run with pp collisions at √s = 7–8 TeV in 2011–2012, focusing mainly on data collected in 2012. Measurements of the reconstruction efficiency and of the momentum scale and resolution, based on large reference samples of J/ψ → μμ, Z → μμ and ϒ → μμ decays, are presented and compared to Monte Carlo simulations. Corrections to the simulation, to be used in physics analysis, are provided. Over most of the covered phase space (muon |η| < 2.7 and 5 ≲ pT ≲ 100 GeV) the efficiency is above 99% and is measured with per-mille precision. The momentum resolution ranges from 1.7% at central rapidity and for transverse momentum pT ≅ 10 GeV, to 4% at large rapidity and pT ≅ 100 GeV. The momentum scale is known with an uncertainty of 0.05% to 0.2% depending on rapidity. A method for the recovery of final state radiation from the muons is also presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND The aim of newborn screening (NBS) for CF is to detect children with 'classic' CF where early treatment is possible and improves prognosis. Children with inconclusive CF diagnosis (CFSPID) should not be detected, as there is no evidence for improvement through early treatment. No algorithm in current NBS guidelines explains what to do when sweat test (ST) fails. This study compares the performance of three different algorithms for further diagnostic evaluations when first ST is unsuccessful, regarding the numbers of children detected with CF and CFSPID, and the time until a definite diagnosis. METHODS In Switzerland, CF-NBS was introduced in January 2011 using an IRT-DNA-IRT algorithm followed by a ST. In children, in whom ST was not possible (no or insufficient sweat), 3 different protocols were applied between 2011 and 2014: in 2011, ST was repeated until it was successful (protocol A), in 2012 we proceeded directly to diagnostic DNA testing (protocol B), and 2013-2014, fecal elastase (FE) was measured in the stool, in order to determine a pancreas insufficiency needing immediate treatment (protocol C). RESULTS The ratio CF:CFSPID was 7:1 (27/4) with protocol A, 2:1 (22/10) with protocol B, and 14:1 (54/4) with protocol C. The mean time to definite diagnosis was significantly shorter with protocol C (33days) compared to protocol A or B (42 and 40days; p=0.014 compared to A, and p=0.036 compared to B). CONCLUSIONS The algorithm for the diagnostic part of the newborn screening used in the CF centers is important and affects the performance of a CF-NBS program with regard to the ratio CF:CFSPID and the time until definite diagnosis. Our results suggest to include FE after initial sweat test failure in the CF-NBS guidelines to keep the proportion of CFSPID low and the time until definite diagnosis short.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

La transformación del concepto de medida en una sociedad interactiva y paramétrica.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Measurement of 8-hydroxy-2′-deoxyguanosine (8-OH-dGuo) in DNA by high-performance liquid chromatography/mass spectrometry (LC/MS) was studied. A methodology was developed for separation by LC of 8-OH-dGuo from intact and modified nucleosides in DNA hydrolyzed by a combination of four enzymes: DNase I, phosphodiesterases I and II and alkaline phosphatase. The atmospheric pressure ionization-electrospray process was used for mass spectral measurements. A stable isotope-labeled analog of 8-OH-dGuo was used as an internal standard for quantification by isotope-dilution MS (IDMS). Results showed that LC/IDMS with selected ion-monitoring (SIM) is well suited for identification and quantification of 8-OH-dGuo in DNA at background levels and in damaged DNA. The sensitivity level of LC/IDMS-SIM was found to be comparable to that reported previously using LC-tandem MS (LC/MS/MS). It was found that approximately five lesions per 106 DNA bases can be detected using amounts of DNA as low as 2 µg. The results also suggest that this lesion may be quantified in DNA at levels of one lesion per 106 DNA bases, or even lower, when more DNA is used. Up to 50 µg of DNA per injection were used without adversely affecting the measurements. Gas chromatography/isotope-dilution MS with selected-ion monitoring (GC/IDMS-SIM) was also used to measure this compound in DNA following its removal from DNA by acidic hydrolysis or by hydrolysis with Escherichia coli Fpg protein. The background levels obtained by LC/IDMS-SIM and GC/IDMS-SIM were almost identical. Calf thymus DNA and DNA isolated from cultured HeLa cells were used for this purpose. This indicates that these two techniques can provide similar results in terms of the measurement of 8-OH-dGuo in DNA. In addition, DNA in buffered aqueous solution was damaged by ionizing radiation at different radiation doses and analyzed by LC/IDMS-SIM and GC/IDMS-SIM. Again, similar results were obtained by the two techniques. The sensitivity of GC/MS-SIM for 7,8-dihydro-8-oxoguanine was also examined and found to be much greater than that of LC/MS-SIM and the reported sensitivity of LC/MS/MS for 8-OH-dGuo. Taken together, the results unequivocally show that LC/IDMS-SIM is well suited for sensitive and accurate measurement of 8-OH-dGuo in DNA and that both LC/IDMS-SIM and GC/IDMS-SIM can provide similar results.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Free drug measurement and pharmacodymanic markers provide the opportunity for a better understanding of drug efficacy and toxicity. High-performance liquid chromatography (HPLC)-mass spectrometry (MS) is a powerful analytical technique that could facilitate the measurement of free drug and these markers. Currently, there are very few published methods for the determination of free drug concentrations by HPLC-MS. The development of atmospheric pressure ionisation sources, together with on-line microdialysis or on-line equilibrium dialysis and column switching techniques have reduced sample run times and increased assay efficiency. The availability of such methods will aid in drug development and the clinical use of certain drugs, including anti-convulsants, anti-arrhythmics, immunosuppressants, local anaesthetics, anti-fungals and protease inhibitors. The history of free drug measurement and an overview of the current HPLC-MS applications for these drugs are discussed. Immunosuppressant drugs are used as an example for the application of HPLC-MS in the measurement of drug pharmacodynamics. Potential biomarkers of immunosuppression that could be measured by HPLC-MS include purine nucleoside/nucleotides, drug-protein complexes and phosphorylated peptides. At the proteomic level, two-dimensional gel electrophoresis combined with matrix-assisted laser desorption/ionisation time-of-flight (TOF) MS is a powerful tool for identifying proteins involved in the response to inflammatory mediators. (C) 2003 Elsevier Science B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The authors describe a reverse-phase high-performance liquid chromatography-electrospray-tandem mass spectrometry method for the measurement of nicotine in human plasma. Samples (500 muL) with added deuterium-labeled d(3)-nicotine as an internal standard (IS) were treated with a 2-step process of ether extraction (6 mL) followed by back-extraction into 0.1% formic acid (50 muL). Chromatography was performed on a phenyl Novapak column with a mobile phase consisting of 50% 10 mM ammonium fortriate (pH 3.3) and acetonitrile (50:50, vol/vol). A flow rate of 0.2 mL/min resulted in a total analysis time of 5 minutes per sample. Mass spectrometric detection was by selected reactant monitoring (nicotine m/z 163.2 --> 130.2; IS m/z 166.2 --> 87.2). The assay was linear from 0.5 to 100 mug/L (r > 0.993, n = 9). The accuracy and imprecision of the method for quality control sampleswere 87.5% to 113% and < 10.2%, respectively. Interday accuracy and imprecision at the limit of quantification (0.5 mug/L) was 113% and 7.2% (n = 4). The process efficiency for nicotine in plasma was > 75%. The method described has good process efficiency, stabilized nicotine, avoided concentration steps, and most importantly minimized potential contamination. Further, we have established that water-based standards and controls are interchangeable with plasma-based samples. This method was used successfully to measure the pharmacokinetic profiles of subjects involved in the development of an aerosol inhalation drug delivery system.