909 resultados para measurement and metrology


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau Mestre em Engenharia Biomédica

Relevância:

80.00% 80.00%

Publicador:

Resumo:

RESUMO: Um dos principais resultados das intervenções de Fisioterapia dirigidas a utentes com Dor Lombar Crónica (DLC) é reduzir a incapacidade funcional. A Quebec Back Pain Disability Scale (QBPDS) é um instrumento amplamente aceite a nível internacional na medição do nível de incapacidade funcional reportada pelos indivíduos com DLC. O objetivo deste estudo é dar um contributo para a adaptação cultural da versão portuguesa da QBPDS (QBPDS-VP) e investigar o poder de resposta e interpretabilidade da escala. Metodologia: Realizou-se um estudo metodológico, multicentro, baseado num coorte prospetivo de 132 utentes com DLC. Os utentes foram recrutados a partir da lista de espera de 16 serviços de Medicina Física e de Reabilitação/Fisioterapia de várias áreas geográficas de Portugal. A QBPDS- VP foi administrada 3 vezes, em 3 momentos de recolha de dados distintos: T0 - momento inicial (utentes em lista de espera); T1 - 1 semana de intervalo (início dos tratamentos de Fisioterapia); e T2 - 6 semanas de intervalo (pós-intervenção de Fisioterapia). Os dados recolhidos em T0 foram utilizados para a análise fatorial e para o estudo da consistência interna (n=132); os dados da amostra emparelhada de T0 e T1 (n=132) para a fiabilidade teste-reteste; e os dados da amostra emparelhada de T0 e T2 (n=120) para a análise do poder de resposta e interpretabilidade. A âncora externa utilizada foi a perceção global de mudança, neste caso a PGIC- VP, que foi respondida em T1 e T2. O nível de significância para o qual os valores se consideraram satisfatórios foi de p≤ 0,05. O tratamento dos dados foi realizado no software IBM SPSS Statistics (versão 20). Resultados: A QBPDS- VP é uma escala unidimensional, que revela uma excelente consistência interna (α de Cronbach= 0,95) e uma fiabilidade teste-reteste satisfatória (CCI= 0,696; IC 95%: 0,581–0,783). Esta escala demonstrou um poder de resposta moderado, quando aplicada em utentes com DLC ( = 0,426 e AAC= 0,741; IC 95%: 0,645 – 0,837). A Diferença Mínima Detetável (DMD) estimada foi de 19 pontos e as estimativas da Diferença Mínima Clinicamente Importante (DMCI) variaram entre 7 (pelo método curva ROC) e 8 pontos (pelo método “diferença média de pontuação”). A estimativa pela curva ROC deriva do ponto ótimo de corte de 6,5 pontos, com Área Abaixo da Curva (AAC)= 0,741, sensibilidade de 72%, e especificidade de 71%. Uma análise complementar da curva ROC baseada nas diferenças de pontuações da QBPDS, expressa em percentagem, revelou um ponto ótimo de corte de - 24% (AAC= 0,737, sensibilidade de 71%, e especificidade de 71%). Para pontuações iniciais da QBPDS- VP mais altas (≥34 pontos), foi encontrado um ponto ótimo de corte de 10,5 pontos (AAC= 0,738, sensibilidade de 73%, e especificidade de 67%). Conclusão: A QBPDS-VP demonstrou bons níveis de fiabilidade e poder de resposta, recomendando-se o seu uso na medição e avaliação da incapacidade funcional de utentes com DLC. A DMD estimada, de 19 pontos, determinou uma amplitude válida da QBPDS-VP de 19 a 81 pontos. Este estudo propõe estimativas de DMCI da QBPDS- VP numa aplicação específica da escala (em utentes com DLC que são referidos para a intervenção de Fisioterapia). A pontuação inicial da QBPDS- VP deve ser considerada na interpretação de mudanças de pontuação, após a intervenção de Fisioterapia.------------ ABSTRACT: One of the main results of physiotherapy interventions for patients with Chronic Low Back Pain (CLBP) is decrease the functional disability. The Quebec Back Pain Disability Scale (QBPDS) is an instrument widely accepted internationally, in measuring the level of disability reported by individuals with CLBP. The purpose of this study is to contribute to the cultural adaptation of the Portuguese version of QBPDS (QBPDS - PV) and investigate the Responsiveness and Interpretability of QBPDS-PV. Methodology: This was a methodological and multicenter study, based on a sample of 132 subjects with CLBP. The patients were recruited from the waiting lists of 16 medicine rehabilitation service, in many Portugal districts. The Quebec Back Pain Disability Scale was administered in three different moments: T0 – baseline (patients in the waiting list); T1- one week after T0 (the beginning of treatment); and T2 – six weeks after T1 (the posttreatment). The data collected at T0 were used for factor analysis and to study the internal consistency (n = 132); paired sample data of T0 and T1 (n=132) were used for test-retest reliability, and sample data paired for T0 and T2 (n=120) used for responsiveness and interpretability analysis. The external anchor was the global perception of change, measured by the Portuguese version of Patient’s Global Impression of Change (PGIC) Scale. The minimal level of significance established was p ≤ 0,05. Data analysis was performed using the IBM SPSS Statistics software (version 20). Results: The QBPDS-PV is a unidimensional scale, demonstrates an excellent internal consistency (Cronbach's α=0.95) and satisfactory test-retest reliability (ICC= 0.696, 95% CI: 0.581–0.783). The scale revealed moderate responsiveness when applied to patients with CLBP ( = 0.426 and AUC= 0.741, 95% CI: 0.645 - 0.837). The Smallest Detectable Change (SDC) was 19 points, whereas the Minimal Clinically Important Change (MCIC) ranged between 7 (ROC curve method) and 8 points (by the "mean difference score"). The estimate was derived from the ROC curve by an optimal cutoff point of 6.5 points, with Area Under the Curve (AUC)= 0.741, sensitivity 72%, and specificity of 71%. A complementary analysis of the ROC curve based on differences in QBPDS scores from baseline, expressed in percentage, revealed an optimal cutoff point of -24% (AUC= 0.737, sensitivity of 71%, and specificity of 71%). For the highest initial scores of QBPDS-PV (≥ 34 points) was found an optimal cutoff of 10.5 points (AUC= 0.738, sensitivity of 73%, and specificity 67%). Conclusion: The QBPDS-PV demonstrated good levels of reliability and responsiveness, being recommended its use in the measurement and evaluation of disability of patients with CLBP. The SDC of 19 points determined the QBPDS‟ scale width of 19 to 81. This study proposes MCIC values for QBPDS –PV for this specific setting (in CLBP patients who are referred for physiotherapy intervention). The QBPDS –PV baseline score have to be taken into account while interpreting the score change after physiotherapy intervention.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics

Relevância:

80.00% 80.00%

Publicador:

Resumo:

ABSTRACT:C-reactive protein (CRP) has been widely used in the early risk assessment of patients with acute pancreatitis (AP), but unclear aspects about its prognostic accuracy in this setting persist. This project evaluated first CRP prognostic accuracy for severity, pancreatic necrosis (PNec), and in-hospital mortality (IM) in AP in terms of the best timing for CRP measurement and the optimal CRP cutoff points. Secondly it was evaluated the CRP measured at approximately 24 hours after hospital admission (CRP24) prognostic accuracy for IM in AP individually and in a combined model with a recent developed tool for the early risk assessment of patients with AP, the Bedside Index for Severity in AP (BISAP). Two single-centre retrospective cohort studies were held. The first study included 379 patients and the second study included 134 patients. Statistical methods such as the Hosmer-Lemeshow goodness-of-fit test, the area under the receiver-operating characteristic curve, the net reclassification improvement, and the integrated discrimination improvement were used. It was found that CRP measured at approximately 48 hours after hospital admission (CRP48) had a prognostic accuracy for severity, PNec, and IM in AP better than CRP measured at any other timing. It was observed that the optimal CRP48 cutoff points for severity, PNec, and IM in AP varied from 170mg/l to 190mg/l, values greater than the one most often recommended in the literature – 150mg/l. It was found that CRP24 had a good prognostic accuracy for IM in AP and that the cutoff point of 60mg/l had a negative predictive value of 100%. Finally it was observed that the prognostic accuracy of a combined model including BISAP and CRP24 for IM in AP could perform better than the BISAP alone model. These results might have a direct impact on the early risk assessment of patients with AP in the daily clinical practice.--------- RESUMO: A proteina c-reactiva (CRP) tem sido largamente usada na avaliação precoce do risco em doentes com pancreatite aguda (AP), mas aspectos duvidosos acerca do seu valor prognóstico neste contexto persistem. Este projecto avaliou primeiro o valor prognóstico da CRP para a gravidade, a necrose pancreática (PNec) e a mortalidade intra-hospitalar (IM) na AP em termos do melhor momento para efectuar a sua medição e dos seus pontos-de-corte óptimos. Em segundo lugar foi avaliado o valor prognóstico da proteína c-reactiva medida aproximadamente às 24 horas após a admissão hospitalar (CRP24) para a IM na AP isoladamente e num modelo combinado, que incluiu uma ferramenta de avaliação precoce do risco em doentes com AP recentemente desenvolvida, o Bedside Index for Severity in Acute Pancreatitis (BISAP). Dois estudos unicêntricos de coorte retrospectivo foram realizados. O primeiro estudo incluiu 379 doentes e o segundo estudo incluiu 134 doentes. Metodologias estatísticas como o teste de Hosmer-Lemeshow goodness-of-fit, a area under the receiver-operating characteristic curve, o net reclassification improvement e o integrated discrimination improvement foram usadas. Verificou-se que a CRP medida às 48 horas após a admissão hospitalar (CRP48) teve um valor prognóstico para a gravidade, a PNec e a IM na AP melhor do que a CRP medida em qualquer outro momento. Observou-se que os pontos de corte óptimos da CRP48 para a gravidade, a PNec e a IM na AP variaram entre 170mg/l e 190mg/l, valores acima do valor mais frequentemente recomendado na literatura – 150mg/l. Verificou-se que a CRP medida aproximadamente às 24 horas após a admissão hospitalar (CRP24) teve um bom valor prognóstico para a IM na AP e que o ponto de corte 60mg/l teve um valor preditivo negativo de 100%. Finalmente observou-se que o valor prognóstico de um modelo combinado incluindo o BISAP e a CRP24 para a IM na AP pode ter um desempenho melhor do que o do BISAP isoladamente. Estes resultados podem ter um impacto directo na avaliação precoce do risco em doentes com AP na prática clínica diária.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics

Relevância:

80.00% 80.00%

Publicador:

Resumo:

RESUMO: A gestão de ocorrências, sendo um requisito, quer legal, ao nível da regulação, quer normativo, tal como surge na ISO 9001, é um componente crítico para garantir a melhoria contínua um Serviço de Sangue, dado ter como objetivo a satisfação contínua dos requisitos dos dadores e recetores. A gestão eficaz, mas com eficiência, depende, também da eficácia da abordagem para gestão de ocorrência, nomeadamente, através da geração de correções, ações corretivas e ações preventiva eficazes. Esta dissertação discute a relevância, propondo um modelo de abordagem de gestão da qualidade conforme com os requisitos da lei fundamental da regulação de Serviços de Sangue, DL 267/2007, e com a norma global para sistemas de gestão da qualidade, ISO 9001. Esta abordagem usada descreve as várias etapas para a gestão eficaz de ocorrências, desde o seu relato, à sua classificação, tratamento com medição e análise risco associado e verificação da eficácia das ações tomadas. A eficácia do modelo teórico proposto foi verificado através da sua passagem para algoritmo informático num software comercial. Foi evidenciado neste software o cumprimento dos requisitos da abordagem teórica, pelo que a aplicação informática está conforme com os requisitos estabelecidos num procedimento documentado. Foi evidenciado, também, a rastreabilidade dos dados ao longo e toda a metodologia. A utilização de uma ferramenta informática também acrescentou valor ao modelo teórico, dado o acesso a toda a informação ser mais célere e de fácil acesso, quando comparado com o uso em suporte de papel.---------ABSTRACT: The issues management is a law requirement intended for regulation of “Blood Banks” and a quality management global requirement from ISO 9001. It is a critical activity, intended to to ensure continuous improvement on “Blood Bank”. Its goal is the continuous satisfaction of blood donors and transfusion recipients. Effective management and efficiency also depend on the effectiveness of the management of occurrence approach, namely in successful corrections, corrective actions and preventive actions. This paper discusses the relevance and it proposes a model approach to quality management according to the requirements of the fundamental law of regulation of “Blood Bank”, DL 267/2007, and according to the global standard for quality management systems, ISO 9001. This approach describes the various steps for effective management of incidents, such as his account, its classification, measurement and treatment using risk analysis and verification of the effectiveness of actions taken. The efficiency of the proposed theoretical model was verified through its transition to a computer algorithm trading software. It was demonstrated in this software that the requirements of the theoretical approach has been fulfilled by the computer application, which complies with the requirements established in a documented procedure. It was also evident that traceability of data across the methodology. The use of a software tool also added value to the theoretical model due to the access to all information to be faster and more easily accessible, when compared to paper.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

HMC08 - 1st Historical Mortars Conference: Characterization, Diagnosis, Conservation, Repair and Compatibility, LNEC, Lisbon, 24-26 September 2008

Relevância:

80.00% 80.00%

Publicador:

Resumo:

When assessing investment options, investors focus on the graphs of annual reports, despite lack of auditing. If poorly constructed, graphs distort perceptions and lead to inaccurate decisions. This study examines graph usage in all the companies listed on Euronext Lisbon in 2013. The findings suggest that graphs are common in the annual reports of Portuguese companies and that, while there is no evidence of Selectivity Distortion, both Measurement and Orientation Distortions are pervasive. The study recommends the auditing of financial graphs, and urges preparers and users of annual reports to be wary of the possibility of graph distortion.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

As intervenções arqueológicas concretizadas entre 1999-2001 permitiram o reconhecimento de contextos referentes ao Hospital Real de Todos-os-Santos, nomeadamente o claustro NE, bem como uma estrutura hidráulica no seu perímetro interno. A identificação do espólio cerâmico e vítreo aqui descartado permite, numa primeira fase, a aferição cronológica e tipológica destes e, consequentemente, do perfil funcional (utilitário, de cozinha e medicinal), numa tentativa de padronização do conjunto arte factual no edifício hospitalar e na cidade de Lisboa. Num segundo estágio, pretendese obter uma leitura concreta no que concerne ao período de utilização desta estrutura, indo de encontro às distintas áreas a vigorar no espaço claustral.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Stents are rigid and perforated tubular structures, which are inserted into blood vessels in order to prevent or inhibit the constriction of blood flow, restoring the normal blood flow, when blood vessels are clogged, being used in 70% of angioplasties. These medical devices assume great importance in the treatment of cardiovascular diseases (CVD) which are the leading cause of death worldwide. In the European Union CVD account for 40% of deaths and assume an estimated annual cost of 196 billion euros[1]. Stents must possess certain requirements, in order to, adequately, perform its function, such as biocompatibility (so that its use does not c ause damage on the health of its user), mechanical strength, radiopacity (so that it is easy to view), longitudinal flexibility, ease of handling, corrosion resistance and having high strength and high radial expansion ability to recover. Stents can be made of different materials, but metals, particularly stainless steel, are the most common. However, metallic stents present several dRawbacks such as corrosion and restenosis, leading to health complications for the patient, or even death. In order to minimize these disadvantages, new materials, like fibrous materials, have been used [2]. Monofilaments present high potential for stents development because, in addition to its biocompatibility, these materials allow the application of various surface treatments, such as antibacterial coatings. Furthermore, monofilament exhibit excellent mechanical properties, like greater stiffness and good results when subjected to compression, tensile and bending forces, since these forces will be directly supported by the monofilament [3]. To minimize the reaction of the human body and Limit the adhesion of microorganisms to the stent surface, some coatings have been developed, including the use of novel metals with antimicrobial properties, like silver. The main objective of this study was the development of fibrous stents, incorporation of silver oxide nanocoating. For the development of the stent, polyester monofilaments with 0.27mm of diameter were used in braiding technology, with a mandrel diameter of 6mm and a braiding angle of 35⁰. The mechanical behaviour of the stent were evaluated by mechanical testing under longitudinal and radial compression, bending. The results of compressive strength tests are according with value from literature: 1.13 to 2.9 N for radial compression and 0. 16-5.28N to longitudinal compression. From literature is also possible to verify that stents must present 75% of unchanged diameter during the bending test and must possess a porosity between 70% and 80% [4]. The produced polyester stent presents values of 1.29N for radial compression, 0.23N for longitudinal compression, 80% of porosity and 85.5% of unchanged diameter, during bending tests. For the antibacterial functionalization, silver oxide nanocoatings were prepared, through reactive magnetron g, with an Ag target in an Ar +O2 atmosphere. In order to evaluate the nanostructure and morphology of the coatings, d ifferent technique s like X-ray diffraction (XRD), scanning electron microscopy (SEM) and and X- ray photoelectron spectroscopy (XPS were used. From the analyses of XRD it is possible to verify that the peaks corresponds to planes of Ag2 O and MATERIAIS 2015 Porto, 21-23 June, 2015 characterize a cubic phase. The presence of Ag2 O is corroborated by XPS spectrum, where it is possible to observe silver, not only, in oxide state, but a lso in mettalic state, and it is possible to verify the presence of silver clusters, confirmed by SEM analysis. Films’ roughness and topography, parameters influencing the wettability of the surface and microorganism adhesion, were measured by Atomic Force Microscopy (AFM), and it was observed that the roughness is very low (under 10 nm). Coatings’ hydrophobicity and surface tension parameters were determined by contact angle measurement, and it was verified the hydrophobic behavior of the coatings. For antibacterial tests were used Staphylococcus epidermidis strain (IE186) and Staphylococcus aureus(ATCC 6538), and halo inhibition zone tests were realized. Ag+release rates were studied by means of inductively coupled plasma mass spectrometry (ICP -MS). The obtained results suggest that silver oxide coatings do not modify significantly surface properties of the substrate, like hydrophobicity and roughness, and present antimicrobial properties for both bacteria used.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Relatório de estágio de mestrado em Contabilidade

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Dissertação de mestrado em Engenharia e Gestão da Qualidade

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O presente trabalho de investigação avalia a situação atual relativa à adoção do disposto na IAS 38 e suas consequências no reconhecimento, mensuração e divulgação obrigatória, e à divulgação voluntária, interna e externa, dos intangíveis nas empresas brasileiras cotadas na BM&FBOVESPA. Adotando a perspectiva positivista e uma abordagem quantitativa, foi utilizado o inquérito por questionário como método de recolha de dados. O questionário foi elaborado de raiz, suportado pelo arcabouço teórico. Os resultados são interpretados à luz dos argumentos da teoria dos stakeholders e da teoria institucional, que revelaram um bom potencial explicativo para o fenômeno em análise. Com a adoção das IAS/IFRS para elaboração dos balanços consolidados de empresas cotadas e não cotadas, o Brasil passa a utilizar a IAS 38, para o registro das operações envolvendo os ativos intangíveis, obrigatoriamente no exercício de 2010. A adoção deste normativo se deu essencialmente por pressões legais. No entanto, as empresas que adotaram a IAS 38 de forma voluntária validaram as razões apresentadas na literatura. Constatou-se que existe concordância quanto à nova forma de contabilização dos intangíveis prevista, sendo o grau de satisfação relativamente ao tratamento contábil dos ativos intangíveis de acordo com o novo modelo contábil adotado no Brasil (IAS 38 e CPC 04) elevado. Como principais dificuldades no reconhecimento contábil dos ativos intangíveis segundo o normativo em vigor, foram confirmados os problemas evidenciados na literatura, tais como incerteza quanto aos benefícios econômicos futuros e falta de medida com confiabilidade suficiente para o registro das transações. As empresas brasileiras acreditam ser importante que haja uma expansão da divulgação sobre intangíveis, no entanto a divulgação interna e externa está ainda em fase embrionária, não sendo uma prática generalizada. Contudo, os objetivos apresentados na literatura para a divulgação interna e externa de informações sobre intangíveis encontram suporte empírico no estudo desenvolvido. No que diz respeito aos stakeholders, conclui-se que as empresas brasileiras têm grande preocupação em atendê-los quando se trata de divulgação voluntária sobre intangíveis, entendendo que todos eles poderão beneficiar com estas informações.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Heart failure with preserved ejection fraction (HFPEF) is the most common form of heart failure (HF), its diagnosis being a challenge to the outpatient clinic practice. Objective: To describe and compare two strategies derived from algorithms of the European Society of Cardiology Diastology Guidelines for the diagnosis of HFPEF. Methods: Cross-sectional study with 166 consecutive ambulatory patients (67.9±11.7 years; 72% of women). The strategies to confirm HFPEF were established according to the European Society of Cardiology Diastology Guidelines criteria. In strategy 1 (S1), tissue Doppler echocardiography (TDE) and electrocardiography (ECG) were used; in strategy 2 (S2), B-type natriuretic peptide (BNP) measurement was included. Results: In S1, patients were divided into groups based on the E/E'ratio as follows: GI, E/E'> 15 (n = 16; 9%); GII, E/E'8 to 15 (n = 79; 48%); and GIII, E/E'< 8 (n = 71; 43%). HFPEF was confirmed in GI and excluded in GIII. In GII, TDE [left atrial volume index (LAVI) ≥ 40 mL/m2; left ventricular mass index LVMI) > 122 for women and > 149 g/m2 for men] and ECG (atrial fibrillation) parameters were assessed, confirming HFPEF in 33 more patients, adding up to 49 (29%). In S2, patients were divided into three groups based on BNP levels. GI (BNP > 200 pg/mL) consisted of 12 patients, HFPEF being confirmed in all of them. GII (BNP ranging from 100 to 200 pg/mL) consisted of 20 patients with LAVI > 29 mL/m2, or LVMI ≥ 96 g/m2 for women or ≥ 116 g/m2 for men, or E/E'≥ 8 or atrial fibrillation on ECG, and the diagnosis of HFPEF was confirmed in 15. GIII (BNP < 100 pg/mL) consisted of 134 patients, 26 of whom had the diagnosis of HFPEF confirmed when GII parameters were used. Measuring BNP levels in S2 identified 4 more patients (8%) with HFPEF as compared with those identified in S1. Conclusion: The association of BNP measurement and TDE data is better than the isolated use of those parameters. BNP can be useful in identifying patients whose diagnosis of HF had been previously excluded based only on TDE findings.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pensado en un ámbito de tecnología médica, el propósito principal es el de realizar un seguido de medidas en diferentes partes del cuerpo para establecer unos valores máximos que nos permitan detectar cuando un paciente empieza a padecer estrés. Para ello se necesita un proceso de medición y otro de transmisión de los datos. Es aquí donde aparece el trabajo realizado en el proyecto. “ZigBee aplicado a la transmisión de datos de sensores biomédicos” está pensado para realizar la tarea de transmisión de los datos desde que el sensor realiza la medida hasta que los datos son monitorizados y almacenados. En la memoria del proyecto podremos encontrar el estudio realizado al medio de transmisión inalámbrico utilizado (ZigBee), el análisis del kit eZ430-RF2500 compatible con el medio, y finalmente la implementación del proyecto. Todo este trabajo finalizará con la recepción satisfactoria de los datos medidos por nuestro sensor biomédico (oxímetro) en el aplicativo personal programado con Visual Basic.