708 resultados para graphite-polyurethane composite electrode
Resumo:
Prediction of variety composite means was shown to be feasible without diallel crossing the parental varieties. Thus, the predicted mean for a quantitative trait of a composite is given by: Yk = a1 sigmaVj + a2sigmaTj + a3 - a4, with coefficients a1 = (n - 2k)/k²(n - 2); a2 = 2n(k - 1)/k²(n - 2); a3 = n(k - 1)/k(n - 1)(n - 2); and a4 = n²(k - 1)/k(n - 1)(n - 2); summation is for j = 1 to k, where k is the size of the composite (number of parental varieties of a particular composite) and n is the total number of parent varieties. Vj is the mean of varieties and Tj is the mean of topcrosses (pool of varieties as tester), and and are the respective average values in the whole set. Yield data from a 7 x 7 variety diallel cross were used for the variety means and for the "simulated" topcross means to illustrate the proposed procedure. The proposed prediction procedure was as effective as the prediction based on Yk = - ( -)/k, where and refer to the mean of hybrids (F1) and parental varieties, respectively, in a variety diallel cross. It was also shown in the analysis of variance that the total sum of squares due to treatments (varieties and topcrosses) can be orthogonally partitioned following the reduced model Yjj = mu + ½(v j + v j) + + h j+ h j, thus making possible an F test for varieties, average heterosis and variety heterosis. Least square estimates of these effects are also given
Resumo:
A new protocol is described for immunization of outbred Swiss mice. The procedure is based on subcutaneous implantation of antigen-coupled polyester-polyurethane sponges cut into disks of 10 mm in diameter vs 2 mm in thickness. Antigen coupling was performed by overnight incubation of the sponge with a solution of ovalbumin (Ova) (2 mg/ml) diluted in sodium carbonate buffer, pH 9.6. The amount of ovalbumin that was taken up by the sponge was between 71.4 to 82.5 µg. This was estimated by comparing the Ova absorbance at 280 nm in coating buffer solutions before and after incubation. To compare the efficiency of the proposed method, experimental groups immunized with the antigen in the presence of adjuvants (10 µg in Al(OH)3 or 100 µg in complete Freund's adjuvant (CFA)) were run in parallel. The data obtained after the 3rd week of immunization indicate that both cellular and humoral immune responses were achieved. These were assayed by antigen-induced footpad swelling and ELISA (specific antibodies), respectively. The levels of both immune responses elicited were similar to the responses observed in mice immunized with ovalbumin in the presence of Al(OH)3. The method might represent an advantage when immunizing with pathogenic antigens. Preliminary experiments have suggested that the antigen remains immobilized or bound to the sponge for a long period of time, since there is an increment on the cell population inside the sponges after boosting the animals. If so, the undesirable effects of immunization would be reduced.
Resumo:
Graphene is a material with extraordinary properties. Its mechanical and electrical properties are unparalleled but the difficulties in its production are hindering its breakthrough in on applications. Graphene is a two-dimensional material made entirely of carbon atoms and it is only a single atom thick. In this work, properties of graphene and graphene based materials are described, together with their common preparation techniques and related challenges. This Thesis concentrates on the topdown techniques, in which natural graphite is used as a precursor for the graphene production. Graphite consists of graphene sheets, which are stacked together tightly. In the top-down techniques various physical or chemical routes are used to overcome the forces keeping the graphene sheets together, and many of them are described in the Thesis. The most common chemical method is the oxidisation of graphite with strong oxidants, which creates a water-soluble graphene oxide. The properties of graphene oxide differ significantly from pristine graphene and, therefore, graphene oxide is often reduced to form materials collectively known as reduced graphene oxide. In the experimental part, the main focus is on the chemical and electrochemical reduction of graphene oxide. A novel chemical route using vanadium is introduced and compared to other common chemical graphene oxide reduction methods. A strong emphasis is placed on electrochemical reduction of graphene oxide in various solvents. Raman and infrared spectroscopy are both used in in situ spectroelectrochemistry to closely monitor the spectral changes during the reduction process. These in situ techniques allow the precise control over the reduction process and even small changes in the material can be detected. Graphene and few layer graphene were also prepared using a physical force to separate these materials from graphite. Special adsorbate molecules in aqueous solutions, together with sonic treatment, produce stable dispersions of graphene and few layer graphene sheets in water. This mechanical exfoliation method damages the graphene sheets considerable less than the chemical methods, although it suffers from a lower yield.
Resumo:
The aim of this research is to examine the pricing anomalies existing in the U.S. market during 1986 to 2011. The sample of stocks is divided into decile portfolios based on seven individual valuation ratios (E/P, B/P, S/P, EBIT/EV, EVITDA/EV, D/P, and CE/P) and price momentum to investigate the efficiency of individual valuation ratio and their combinations as portfolio formation criteria. This is the first time in financial literature when CE/P is employed as a constituent of composite value measure. The combinations are based on median scaled composite value measures and TOPSIS method. During the sample period value portfolios significantly outperform both the market portfolio and comparable glamour portfolios. The results show the highest return for the value portfolio that was based on the combination of S/P & CE/P ratios. The outcome of this research will increase the understanding on the suitability of different methodologies for portfolio selection. It will help managers to take advantage of the results of different methodologies in order to gain returns above the market.
Resumo:
We developed an efficient method to prepare a hybrid inorganic-organic composite based on polyvinyl alcohol (PVA) and polysiloxane using the sol-gel disc technique. Antigen obtained from Yersinia pestis was covalently immobilized onto these discs with glutaraldehyde and used as solid phase in ELISA for antibody detection in serum of rabbits experimentally immunized with plague. Using 1.25 µg antigen per disc, a peroxidase conjugate dilution of 1:4,000 and a serum dilution of 1:200 were adequate for the establishment of the procedure. These values are similar to those used for PVA-glutaraldehyde discs, plasticized filter paper discs and the polyaniline-Dacron composite discs. This procedure is comparable to that which utilizes the adsorption of the antigen to conventional PVC plates, with the amount of antigen being one fourth that employed in conventional PVC plates (5 µg/well). In addition to the performance of the polysiloxane/PVA-glutaraldehyde disc as a matrix for immunodetection, its easy synthesis and low cost are additional advantages for commercial application.
Resumo:
Non-metallic implants made of bioresorbable or biostable synthetic polymers are attractive options in many surgical procedures, ranging from bioresorbable suture anchors of arthroscopic surgery to reconstructive skull implants made of biostable fiber-reinforced composites. Among other benefits, non-metallic implants produce less interference in imaging. Bioresorbable polymer implants may be true multifunctional, serving as osteoconductive scaffolds and as matrices for simultaneous delivery of bone enhancement agents. As a major advantage for loading conditions, mechanical properties of biostable fiber-reinforced composites can be matched with those of the bone. Unsolved problems of these biomaterials are related to the risk of staphylococcal biofilm infections and to the low osteoconductivity of contemporary bioresorbable composite implants. This thesis was focused on the research and development of a multifunctional implant model with enhanced osteoconductivity and low susceptibility to infection. In addition, the experimental models for assessment, diagnostics and prophylaxis of biomaterial-related infections were established. The first experiment (Study I) established an in vitro method for simultaneous evaluation of calcium phosphate and biofilm formation on bisphenol-Aglycidyldimethacrylate and triethylenglycoldimethacrylate (BisGMA-TEGDMA) thermosets with different content of bioactive glass 45S5. The second experiment (Study II) showed no significant difference in osteointegration of nanostructured and microsized polylactide-co-glycolide/β-tricalcium phosphate (PLGA /β-TCP) composites in a minipig model. The third experiment (Study III) demonstrated that positron emission tomography (PET) imaging with the novel 68Ga labelled 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) CD33 related sialic-acid immunoglobulin like lectins (Siglec-9) tracer was able to detect inflammatory response to S. epidermidis and S. aureus peri-implant infections in an intraosseous polytetrafluoroethylene catheter model. In the fourth experiment (Study IV), BisGMATEGDMA thermosets coated with lactose-modified chitosan (Chitlac) and silver nanoparticles exhibited antibacterial activity against S. aureus and P. aeruginosa strains in an in vitro biofilm model and showed in vivo biocompatibility in a minipig model. In the last experiment (Study V), a selective androgen modulator (SARM) released from a poly(lactide)-co-ε-caprolactone (PLCL) polymer matrix failed to produce a dose-dependent enhancement of peri-implant osteogenesis in a bone marrow ablation model.
Resumo:
Tässä työssä tavoitteena oli selvittää selluloosageelien soveltuvuutta superkondensaattorien elektrodimateriaaliksi. Superkondensaattoreiden elektrodit valmistetaan yleensä hyvin huokoisesta hiilimateriaalista. Näin ollen selluloosageeliin joukkoon sekoitettiin sähkönjohtavuutta parantamaan hiilimustaa. Kirjallisessa osassa keskityttiin superkondensaattorin toimintaperiaatteeseen, rakenteeseen ja yleisimmin käytössä oleviin elektrodimateriaaleihin. Yksityiskohtaisemmin paneuduttiin selluloosan käyttöön superkondensaattorien rakennemateriaalina. Kokeellisessa osassa valmistettiin erilaisia selluloosageelejä ja tämän jälkeen elektrodeja hiilimusta-selluloosageeli-seoksesta. Eri sekoitustapojen vaikutusta elektrodin sähköisiin ominaisuuksiin tarkasteltiin sekoittamalla hiilimustaa selluloosageeliin kahdella eri tavalla; korkeapainehajottajalla ja sekoittimella. Tämän lisäksi selvitettiin myös eri kuivaustapojen ja kuivauslämpötilojen vaikutusta elektrodiarkkien ominaisuuksiin. Arkkien sähköiset ominaisuudet määritettiin syklistä voltammetriaa (SV) käyttäen. Saavutetut tulokset osoittivat, että selluloosageelin valmistus on yksi kriittisimmistä kohdista elektrodimateriaalin valmistuksessa. Riittävä entsyymikäsittely vaaditaan, jotta saadaan muodostettua sopiva geeli, johon hiilimusta-partikkelit saadaan takertumaan. Hiilimustan sekoitustavalla sekä elektrodiarkin kuivauslämpötilalla ja – tavalla on myös suuresti vaikutusta elektrodin sähköisiin ominaisuuksiin.
Resumo:
The objective of the present study was to determine the reliability of the Brazilian version of the Composite International Diagnostic Interview 2.1 (CIDI 2.1) in clinical psychiatry. The CIDI 2.1 was translated into Portuguese using WHO guidelines and reliability was studied using the inter-rater reliability method. The study sample consisted of 186 subjects from psychiatric hospitals and clinics, primary care centers and community services. The interviewers consisted of a group of 13 lay and three non-lay interviewers submitted to the CIDI training. The average interview time was 2 h and 30 min. General reliability ranged from kappa 0.50 to 1. For lifetime diagnoses the reliability ranged from kappa 0.77 (Bipolar Affective Disorder) to 1 (Substance-Related Disorder, Alcohol-Related Disorder, Eating Disorders). Previous year reliability ranged from kappa 0.66 (Obsessive-Compulsive Disorder) to 1 (Dissociative Disorders, Maniac Disorders, Eating Disorders). The poorest reliability rate was found for Mild Depressive Episode (kappa = 0.50) during the previous year. Training proved to be a fundamental factor for maintaining good reliability. Technical knowledge of the questionnaire compensated for the lack of psychiatric knowledge of the lay personnel. Inter-rater reliability was good to excellent for persons in psychiatric practice.
Resumo:
Tämän työn tarkoitus on seuloa oleelliset prosessiparametrit superkondensaattoreiden elektrodikomposiittien valmistuksessa, jotka vaikuttavat kondensaattorin laatuun. Tarkoitus on tutkia parametreja, joiden avulla prosessia on mahdollista optimoida. Työn tarkoituksena on tutkia myös itse komponenttimateriaalien valmistusvaiheen sekoitusprosessia mitatulla ja laskennallisella seokseen siirtyvällä tehonkulutuksella. Työn kirjallisuusosassa esitetään superkondensaattoreiden rakennetta, toimintamekanismia ja ominaisuuksia sähköenergian varastoijana. Lisäksi tarkastellaan tavallisimpia kondensaattoreihin sisältyviä materiaaleja, erityisesti hiilinanoputkia ja selluloosakuituja. Sekoitusprosesseista tarkastellaan kokeellisessa osassa käytettävien sekoituslaitteita ja niiden toimintamekanismeja komponenttien sekoitusprosesseissa. Kokeellisessa osassa tutkimuskysymyksiksi asetettiin eri sekoitusparametrien (materiaalin määrä ja laatu sekä sekoitusajat) vaikutus superkondensaattorien elektrodiarkkien ominaiskapasitansseihin. Testit suoritettiin LUT Prosessien laboratoriossa, ja testeissä massojen sekoitukseen käytettiin roottoristaattoria ja ultraäänisekoitinta. Lisäksi tutkittiin prosessin skaalausta varten skaalatulla laitteistolla sekoitettuja massanäytteitä. Sekoitusprosessin riittävyyttä varten tutkittiin kokeellisesti käytettyjen sekoituslaitteiden tehonkulutusta. Lisäksi roottoristaattorille tehtiin laskentaohjelmalla virtaussimulaatio paikallisen tehonkulutuksen selvittämiseksi Testeissä todettiin tutkittujen parametrien vaikutus, mutta tulosten perusteella varsinaista optimointia ei kyetty tekemään. Tulokset kuitenkin antavat suunnan, johon prosessia voi optimointia varten kehittää. Myös sekoitukseen todettiin siirtyvän suuri määrä tehoa tutkituilla laitteilla, mitä voidaan pitää mahdollisesti riittävänä käytettyjen komponenttien sekoitukseen.
Resumo:
Lappeenranta University of Technology School of Technology Technical Physics Evgenii Zhukov MAGNETIZATION STUDIES OF POLYSTYRENE/MULTIWALL CARBON NANOTUBE COMPOSITE FILMS Master’s thesis 2015 55 pages, 41 pictures, 9 Tables. Examiners: Professor Erkki Lähderanta D.Sc. Ivan Zakharchuk Keywords: polystyrene, multi-walled carbon nanotubes, MWCNT, composite, magnetization, SQUID. In this thesis magnetic properties of polystyrene/multiwall carbon nanotube (MWCNT) composites are investigated with Quantum Design SQUID magnetometer (MPMS XL). The surface of the composite films is studied via BRUKER Multimode 8 Atomic Force Microscope, as well. The polystyrene/MWCNT composites have been prepared by the group of professor Okotrub (Physics Chemistry of Nanomaterials laboratory, Nikolaev Institute of Inorganic Chemistry, Russia). The composite films have been prepared by solution processing and stretching method. The approximate length and inner diameter of the MWCNTs used in fabrication are 260 μm and 10 nm, respectively. The content of MWCNTs is 1 and 2.5 contents percent (wt%) for studied samples. The stretching of the samples is 30% for samples with 1 and 2.5 wt% content, and one sample with 1 wt% loading of MWCNTs is 100% stretched. MWCNTs aligned perpendicular to a silicon substrate are used as a reference sample. The magnetization field dependencies of the samples exhibit hysteresis behavior. The values of saturation magnetization of composite films are much less compared to that of the reference sample. The saturation magnetization coercitivity field value drops with decrease of MWCNT content. At high magnetic fields strong presence of diamagnetism is observed. Measurements in magnetic field parallel and perpendicular to the composite plate display anisotropy with respect to the direction of stretching. Temperature dependences of magnetization for all samples display difference between zero-field cooled and field-cooled curves of magnetization. This divergence confirms the presence of magnetic interactions in the material. The atomic force microscopy study of the composites’ surfaces revealed that they are relatively smooth and the nanotubes are aligned with the axis of stretching to some extent.
Resumo:
The main objective of this thesis is to study the impact of different mineral fillers and fire retardants on the reaction-to-fire properties of extruded/coextruded wood-plastic composites (WPCs). The impact of additives on the flammability properties of WPCs is studied by cone calorimetry. The studied properties are ignition time, peak heat release rate, total heat release, total smoke production, and mass loss rate. The effects of mineral fillers and fire retardants were found to vary with the type of additive, the type of additive combinations, the amount of additives, as well as the production method of the WPCs. The study shows that talc can be used to improve the properties of extruded WPCs. Especially ignition time, peak heat release rate and mass loss rate were found to be improved significantly by talc. The most significant improvement in the fire retardancy of coextruded WPCs was achieved in combinations of natural graphite and melamine. Ignition time, peak heat release rate and total smoke production were improved essentially. High increase in smoke production was found in samples where the amount of ammonium polyphosphate was 10% or higher. Coextrusion as a structural modification was found as a promising way to improve the flammability properties of composite materials in a cost-effective way.
Resumo:
In a serial feature-positive conditional discrimination procedure the properties of a target stimulus A are defined by the presence or not of a feature stimulus X preceding it. In the present experiment, composite features preceded targets associated with two different topography operant responses (right and left bar pressing); matching and non-matching-to-sample arrangements were also used. Five water-deprived Wistar rats were trained in 6 different trials: X-R®Ar and X-L®Al, in which X and A were same modality visual stimuli and the reinforcement was contingent to pressing either the right (r) or left (l) bar that had the light on during the feature (matching-to-sample); Y-R®Bl and Y-L®Br, in which Y and B were same modality auditory stimuli and the reinforcement was contingent to pressing the bar that had the light off during the feature (non-matching-to-sample); A- and B- alone. After 100 training sessions, the animals were submitted to transfer tests with the targets used plus a new one (auditory click). Average percentages of stimuli with a response were measured. Acquisition occurred completely only for Y-L®Br+; however, complex associations were established along training. Transfer was not complete during the tests since concurrent effects of extinction and response generalization also occurred. Results suggest the use of both simple conditioning and configurational strategies, favoring the most recent theories of conditional discrimination learning. The implications of the use of complex arrangements for discussing these theories are considered.
Resumo:
We compared two electroretinography (ERG) electrodes in dogs using ERG standards of the International Society for Clinical Electrophysiology of Vision (ISCEV). Ten healthy Yorkshire terrier dogs (mean age, 2.80 ± 1.42 years; 6 females) weighing 5.20 ± 1.56 kg were evaluated using an ERG system for veterinary use. Dark- and light-adapted ERG responses were recorded using an ERG-Jet electrode and a fiber electrode prototype. The examinations were performed during 2 visits, 3 weeks apart. Both electrodes (ERG-Jet or fiber prototype) were used on each animal and the first eye to be recorded (OD × OS) was selected randomly. Three weeks later the examination was repeated on the same animal switching the type of electrode to be used that day and the first eye to be examined. The magnitude and waveform quality obtained with the two electrode types were similar for all ERG responses. ERG amplitudes and implicit times obtained from dogs using the fiber electrode prototype were comparable to those obtained with the ERG-Jet electrode for rod, maximal rod-cone summed, cone, and 30-Hz flicker responses. The fiber electrode prototype is a low-cost device, available as an alternative instrument for clinical veterinary ERG recording for retinal function assessment.
Resumo:
Fiber-reinforced composite fixed dental prostheses – Studies of the materials used as pontics University of Turku, Faculty of Medicine, Institute of Dentistry, Department of Biomaterials Science, Finnish Doctoral Program in Oral Sciences – FINDOS, Annales Universitatis Turkuensis, Turku, Finland 2015 Fiber-reinforced composites (FRC), a non-metallic biomaterial, represent a suitable alternative in prosthetic dentistry when used as a component of fixed dental prostheses (FDPs). Some drawbacks have been identified in the clinical performance of FRC restorations, such as delamination of the veneering material and fracture of the pontic. Therefore, the current series of studies were performed to investigate the possibilities of enhancing the mechanical and physical properties of FRC FDPs by improving the materials used as pontics, to then heighten their longevity. Four experiments showed the importance of the pontic design and surface treatment in the performance of FRC FDPs. In the first, the load-bearing capacities of inlay-retained FRC FDPs with pontics of various materials and thicknesses were evaluated. Three different pontic materials were assessed with different FRC framework vertical positioning. Thicker pontics showed increased load-bearing capacities, especially ceramic pontics. A second study was completed investigating the influence of the chemical conditioning of the ridge-lap surface of acrylic resin denture teeth on their bonding to a composite resin. Increased shear bond strength demonstrated the positive influence of the pretreatment of the acrylic surfaces, indicating dissolution of the denture surfaces, and suggesting potential penetration of the monomer systems into the surface of denture teeth. A third study analyzed the penetration depth of different monomer systems on the acrylic resin denture teeth surfaces. The possibility of establishing a durable bond between acrylic pontics and FRC frameworks was demonstrated by the ability of monomers to penetrate the surface of acrylic resin denture teeth, measured by a confocal scanning type microscope. A fourth study was designed to evaluate the load-bearing capacities of FRC FDPs using the findings of the previous three studies. In this case, the performance of pre-shaped acrylic resin denture teeth used as pontics with different composite resins as filling materials was evaluated. The filling material influenced the load-bearing capacities, providing more durable FRC FDPs. It can be concluded that the mechanical and physical properties of FRC FDPs can be improved as has been shown in the development of this thesis. The improvements reported then might provide long lasting prosthetic solutions of this kind, positioning them as potentially permanent rehabilitation treatments. Key words: fiber-reinforced composite, fixed dental prostheses, inlay-retained bridges, adhesion, acrylic resin denture teeth, dental material.
Resumo:
The Graphite furnace atomic absorption spectrometry (GF AAS) was the technique chosen by the inorganic contamination laboratory (INCQ/ FIOCRUZ) to be validated and applied in routine analysis for arsenic detection and quantification. The selectivity, linearity, sensibility, detection, and quantification limits besides accuracy and precision parameters were studied and optimized under Stabilized Temperature Platform Furnace (STPF) conditions. The limit of detection obtained was 0.13 µg.L-1 and the limit of quantification was 1.04 µg.L-1, with an average precision, for total arsenic, less than 15% and an accuracy of 96%. To quantify the chemical species As(III) and As(V), an ion-exchange resin (Dowex 1X8, Cl- form) was used and the physical-chemical parameters were optimized resulting in a recuperation of 98% of As(III) and of 90% of As(V). The method was applied to groundwater, mineral water, and hemodialysis purified water samples. All results obtained were lower than the maximum limit values established by the legal Brazilian regulations, in effect, 50, 10, and 5 µg.L-1 para As total, As(III) e As(V), respectively. All results were statistically evaluated.