943 resultados para fixed point method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We used a slide culture technique to detect tubercle bacilli surviving in sputum smears (n=46) after conventional heat fixation and Ziehl-Neelsen staining. In all heat-fixed sputum smears, tubercle bacilli survived after time 0 (n=22), 24 h (n=7), 48 h (n=7), 72 h (n=4), and seven days (n=6). None of the stained sputum smears showed growth on slide cultures. Viable tubercle bacilli remaining in heat-fixed sputum smears for at least seven days may present an infection risk to laboratory staff. Thus, sputum smears should be stained immediately by the Ziehl-Neelsen method or stored in a safe container to avoid transmission of tuberculosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

iii. Catheter-related bloodstream infection (CR-BSI) diagnosis usually involves catheter withdrawal. An alternative method for CR-BSI diagnosis is the differential time to positivity (DTP) between peripheral and catheter hub blood cultures. This study aims to validate the DTP method in short-term catheters. The results show a low prevalence of CR-BSI in the sample (8.4%). The DTP method is a valid alternative for CR-BSI diagnosis in those cases with monomicrobial cultures (80% sensitivity, 99% specificity, 92% positive predictive value, and 98% negative predictive value) and a cut-off point of 17.7 hours for positivity of hub blood culture may assess in CR-BSI diagnosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fourteen hepatitis C virus (HCV) chronically infected patients were submitted to routine liver biopsy for histological evaluation. Liver samples were assayed to HCV-RNA by in situ hybridization, using digoxigenin labeled probe. HCV genotypes were found to be predominantly type 1 (71.4%), followed by genotype 3 (21.4%), and genotype 2 (7.2%). Alanine-aminotransferase levels were raised in 10 patients. The histopathological scores were minimal (21.4%), mild (57.2%), and moderate (21.4%). Viral RNA was detected in liver cells from nine patients (64.3%). ISH method provides localization and poor confirmation of HCV RNA in the liver tissue of HCV chronic patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. Methods: This randomized controlled double-blind study included to date 31 patients: the gait signatures of 12 patients with mobile-bearing were compared to the gait signatures of 19 patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. Results: Better relative differences between pre-operative and post-operative 3 months and 6 months KSS (122% vs 34% at 3 months, 138% vs 36% at 6 months) and KSS function (154% vs 8% at 3 months, 183% vs 42% at 6 months) scores were observed for the fixed-bearing compared to the mobile-bearing. The same better improvements for fixed-bearing were also found with the range of knee angles (Affected side: 31% vs -5% at 3 months, 47% vs 5% at 6 months), (Unaffected side: 16% vs 5% at 3 months, 15% vs 6% at 6 months) and peak swing speeds of shank (Affected side: 18% vs -2% at 3 months, 30% vs 4% at 6 months), (Unaffected side: 8% vs -3% at 3 months, 7% vs 4% at 6 months). Conclusions: A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Epidermal growth factor receptor (EGFR) and its downstream factors KRAS and BRAF are mutated in several types of cancer, affecting the clinical response to EGFR inhibitors. Mutations in the EGFR kinase domain predict sensitivity to the tyrosine kinase inhibitors gefitinib and erlotinib in lung adenocarcinoma, while activating point mutations in KRAS and BRAF confer resistance to the anti-EGFR monoclonal antibody cetuximab in colorectal cancer. The development of new generation methods for systematic mutation screening of these genes will allow more appropriate therapeutic choices. METHODS: We describe a high resolution melting (HRM) assay for mutation detection in EGFR exons 19-21, KRAS codon 12/13 and BRAF V600 using formalin-fixed paraffin-embedded samples. Somatic variation of KRAS exon 2 was also analysed by massively parallel pyrosequencing of amplicons with the GS Junior 454 platform. RESULTS: We tested 120 routine diagnostic specimens from patients with colorectal or lung cancer. Mutations in KRAS, BRAF and EGFR were observed in 41.9%, 13.0% and 11.1% of the overall samples, respectively, being mutually exclusive. For KRAS, six types of substitutions were detected (17 G12D, 9 G13D, 7 G12C, 2 G12A, 2 G12V, 2 G12S), while V600E accounted for all the BRAF activating mutations. Regarding EGFR, two cases showed exon 19 deletions (delE746-A750 and delE746-T751insA) and another two substitutions in exon 21 (one showed L858R with the resistance mutation T590M in exon 20, and the other had P848L mutation). Consistent with earlier reports, our results show that KRAS and BRAF mutation frequencies in colorectal cancer were 44.3% and 13.0%, respectively, while EGFR mutations were detected in 11.1% of the lung cancer specimens. Ultra-deep amplicon pyrosequencing successfully validated the HRM results and allowed detection and quantitation of KRAS somatic mutations. CONCLUSIONS: HRM is a rapid and sensitive method for moderate-throughput cost-effective screening of oncogene mutations in clinical samples. Rather than Sanger sequence validation, next-generation sequencing technology results in more accurate quantitative results in somatic variation and can be achieved at a higher throughput scale.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study we compared two polymerase chain reaction (PCR) methods using either 16S ribosomal RNA (rRNA) or 23S rRNA gene primers for the detection of different Leptospira interrogans serovars. The performance of these two methods was assessed using DNA extracted from bovine tissues previously inoculated with several bacterial suspensions. PCR was performed on the same tissues before and after the formalin-fixed, paraffin-embedding procedure (FFPE tissues). The 23S rDNA PCR detected all fresh and FFPE positive tissues while the 16S rDNA-based protocol detected primarily the positive fresh tissues. Both methods are specific for pathogenic L. interrogans. The 23S-based PCR method successfully detected Leptospira in four dubious cases of human leptospirosis from archival tissue specimens and one leptospirosis-positive canine specimen. A sensitive method for leptospirosis identification in FFPE tissues would be a useful tool to screen histological specimen archives and gain a better assessment of human leptospirosis prevalence, especially in tropical countries, where large outbreaks can occur following the rainy season.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quantitative or algorithmic trading is the automatization of investments decisions obeying a fixed or dynamic sets of rules to determine trading orders. It has increasingly made its way up to 70% of the trading volume of one of the biggest financial markets such as the New York Stock Exchange (NYSE). However, there is not a signi cant amount of academic literature devoted to it due to the private nature of investment banks and hedge funds. This projects aims to review the literature and discuss the models available in a subject that publications are scarce and infrequently. We review the basic and fundamental mathematical concepts needed for modeling financial markets such as: stochastic processes, stochastic integration and basic models for prices and spreads dynamics necessary for building quantitative strategies. We also contrast these models with real market data with minutely sampling frequency from the Dow Jones Industrial Average (DJIA). Quantitative strategies try to exploit two types of behavior: trend following or mean reversion. The former is grouped in the so-called technical models and the later in the so-called pairs trading. Technical models have been discarded by financial theoreticians but we show that they can be properly cast into a well defined scientific predictor if the signal generated by them pass the test of being a Markov time. That is, we can tell if the signal has occurred or not by examining the information up to the current time; or more technically, if the event is F_t-measurable. On the other hand the concept of pairs trading or market neutral strategy is fairly simple. However it can be cast in a variety of mathematical models ranging from a method based on a simple euclidean distance, in a co-integration framework or involving stochastic differential equations such as the well-known Ornstein-Uhlenbeck mean reversal ODE and its variations. A model for forecasting any economic or financial magnitude could be properly defined with scientific rigor but it could also lack of any economical value and be considered useless from a practical point of view. This is why this project could not be complete without a backtesting of the mentioned strategies. Conducting a useful and realistic backtesting is by no means a trivial exercise since the \laws" that govern financial markets are constantly evolving in time. This is the reason because we make emphasis in the calibration process of the strategies' parameters to adapt the given market conditions. We find out that the parameters from technical models are more volatile than their counterpart form market neutral strategies and calibration must be done in a high-frequency sampling manner to constantly track the currently market situation. As a whole, the goal of this project is to provide an overview of a quantitative approach to investment reviewing basic strategies and illustrating them by means of a back-testing with real financial market data. The sources of the data used in this project are Bloomberg for intraday time series and Yahoo! for daily prices. All numeric computations and graphics used and shown in this project were implemented in MATLAB^R scratch from scratch as a part of this thesis. No other mathematical or statistical software was used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of traffic engineering is to optimize network resource utilization. Although several works have been published about minimizing network resource utilization, few works have focused on LSR (label switched router) label space. This paper proposes an algorithm that takes advantage of the MPLS label stack features in order to reduce the number of labels used in LSPs. Some tunnelling methods and their MPLS implementation drawbacks are also discussed. The described algorithm sets up NHLFE (next hop label forwarding entry) tables in each LSR, creating asymmetric tunnels when possible. Experimental results show that the described algorithm achieves a great reduction factor in the label space. The presented works apply for both types of connections: P2MP (point-to-multipoint) and P2P (point-to-point)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As stated in Aitchison (1986), a proper study of relative variation in a compositional data set should be based on logratios, and dealing with logratios excludes dealing with zeros. Nevertheless, it is clear that zero observations might be present in real data sets, either because the corresponding part is completelyabsent –essential zeros– or because it is below detection limit –rounded zeros. Because the second kind of zeros is usually understood as “a trace too small to measure”, it seems reasonable to replace them by a suitable small value, and this has been the traditional approach. As stated, e.g. by Tauber (1999) and byMartín-Fernández, Barceló-Vidal, and Pawlowsky-Glahn (2000), the principal problem in compositional data analysis is related to rounded zeros. One should be careful to use a replacement strategy that does not seriously distort the general structure of the data. In particular, the covariance structure of the involvedparts –and thus the metric properties– should be preserved, as otherwise further analysis on subpopulations could be misleading. Following this point of view, a non-parametric imputation method isintroduced in Martín-Fernández, Barceló-Vidal, and Pawlowsky-Glahn (2000). This method is analyzed in depth by Martín-Fernández, Barceló-Vidal, and Pawlowsky-Glahn (2003) where it is shown that thetheoretical drawbacks of the additive zero replacement method proposed in Aitchison (1986) can be overcome using a new multiplicative approach on the non-zero parts of a composition. The new approachhas reasonable properties from a compositional point of view. In particular, it is “natural” in the sense thatit recovers the “true” composition if replacement values are identical to the missing values, and it is coherent with the basic operations on the simplex. This coherence implies that the covariance structure of subcompositions with no zeros is preserved. As a generalization of the multiplicative replacement, in thesame paper a substitution method for missing values on compositional data sets is introduced

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Measurement of HbA1c is the most important parameter to assess glycemic control in diabetic patients. Different point-of-care devices for HbA1c are available. The aim of this study was to evaluate two point-of-care testing (POCT) analyzers (DCA Vantage from Siemens and Afinion from Axis-Shield). We studied the bias and precision as well as interference from carbamylated hemoglobin. METHODS Bias of the POCT analyzers was obtained by measuring 53 blood samples from diabetic patients with a wide range of HbA1c, 4%-14% (20-130 mmol/mol), and comparing the results with those obtained by the laboratory method: HPLC HA 8160 Menarini. Precision was performed by 20 successive determinations of two samples with low 4.2% (22 mmol/mol) and high 9.5% (80 mmol/mol) HbA1c values. The possible interference from carbamylated hemoglobin was studied using 25 samples from patients with chronic renal failure. RESULTS The means of the differences between measurements performed by each POCT analyzer and the laboratory method (95% confidence interval) were: 0.28% (p<0.005) (0.10-0.44) for DCA and 0.27% (p<0.001) (0.19-0.35) for Afinion. Correlation coefficients were: r=0.973 for DCA, and r=0.991 for Afinion. The mean bias observed by using samples from chronic renal failure patients were 0.2 (range -0.4, 0.4) for DCA and 0.2 (-0.2, 0.5) for Afinion. Imprecision results were: CV=3.1% (high HbA1c) and 2.97% (low HbA1c) for DCA, CV=1.95% (high HbA1c) and 2.66% (low HbA1c) for Afinion. CONCLUSIONS Both POCT analyzers for HbA1c show good correlation with the laboratory method and acceptable precision.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. This randomized controlled double-blind study included to date 14 patients: the gait signatures of four patients with mobile-bearing were compared to the gait signatures of nine patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this paper is to describe the development and to test the reliability of a new method called INTERMED, for health service needs assessment. The INTERMED integrates the biopsychosocial aspects of disease and the relationship between patient and health care system in a comprehensive scheme and reflects an operationalized conceptual approach to case mix or case complexity. The method is developed to enhance interdisciplinary communication between (para-) medical specialists and to provide a method to describe case complexity for clinical, scientific, and educational purposes. First, a feasibility study (N = 21 patients) was conducted which included double scoring and discussion of the results. This led to a version of the instrument on which two interrater reliability studies were performed. In study 1, the INTERMED was double scored for 14 patients admitted to an internal ward by a psychiatrist and an internist on the basis of a joint interview conducted by both. In study 2, on the basis of medical charts, two clinicians separately double scored the INTERMED in 16 patients referred to the outpatient psychiatric consultation service. Averaged over both studies, in 94.2% of all ratings there was no important difference between the raters (more than 1 point difference). As a research interview, it takes about 20 minutes; as part of the whole process of history taking it takes about 15 minutes. In both studies, improvements were suggested by the results. Analyses of study 1 revealed that on most items there was considerable agreement; some items were improved. Also, the reference point for the prognoses was changed so that it reflected both short- and long-term prognoses. Analyses of study 2 showed that in this setting, less agreement between the raters was obtained due to the fact that the raters were less experienced and the scoring procedure was more susceptible to differences. Some improvements--mainly of the anchor points--were specified which may further enhance interrater reliability. The INTERMED proves to be a reliable method for classifying patients' care needs, especially when used by experienced raters scoring by patient interview. It can be a useful tool in assessing patients' care needs, as well as the level of needed adjustment between general and mental health service delivery. The INTERMED is easily applicable in the clinical setting at low time-costs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The application of the Fry method to measure strain in deformed porphyritic granites is discussed. This method requires that the distribution of markers has to satisfy at least two conditions. It has to be homogeneous and isotropic. Statistics on point distribution with the help of a Morishita diagram can easily test homogeneity. Isotropy can be checked with a cumulative histogram of angles between points. Application of these tests to undeformed (Mte Capanne granite, Elba) and to deformed (Randa orthogneiss, Alps of Switzerland) porphyritic granite reveals that their K-feldspars phenocrysts both satisfy these conditions and can be used as strain markers with the Fry method. Other problems are also examined. One is the possible distribution of deformation on discrete shear-bands. Providing several tests are met, we conclude that the Fry method can be used to estimate strain in deformed porphyritic granites. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: The aim of this study was to compare specificity and sensitivity of different biological markers that can be used in a forensic field to identify potentially dangerous drivers because of their alcohol habits. Methods: We studied 280 Swiss drivers after driving while under the alcohol influence. 33 were excluded for not having CDT N results, 247 were included (218 men (88%) and 29 women (12%). Mean age was 42,4 (SD:12, min: 20 max: 76). The evaluation of the alcohol consumption concerned the month before the CDT test and was considered as such after the interview: Heavy drinkers (>3 drinks per day): 60 (32.7%), < 3 drinks per day and moderate: 127 (51.4%) 114 (46.5%), abstinent: 60 (24.3%) 51 (21%). Alcohol intake was monitored by structured interviews, self-reported drinking habits and the C-Audit questionnaire as well as information provided by their family and general practitioner. Consumption was quantified in terms of standard drinks, which contain approximately 10 grams of pure alcohol (Ref. WHO). Results: comparison between moderate (less or equal to 3 drinks per day) and excessive drinkers (more than 3 drinks) Marker ROC area 95% CI cut-off sensitivity specificity CDT TIA 0.852 0.786-0917 2.6* 0.93 LR+1.43 0.35 LR-0.192 CDT N latex 0.875 0.821-0.930 2.5* 0.66 LR+ 6.93 0.90 LR- 0.369 Asialo+disialo-tf 0.881 0.826-0.936 1.2* 0.78 LR+4.07 0.80 LR-0.268 1.7° 0.66 LR+8.9 0.93 LR-0.360 GGT 0.659 0.580-0.737 85* 0.37 LR+2.14 0.83 LR-0.764 * cut-off point suggested by the manufacturer ° cut-off point suggested by our laboratory Conclusion: With the cut-off point established by the manufacturer, CDT TIA performed poorly in term of specificity. N latex CDT and CZE CDT were better, especially if a 1.7 cut-off is used with CZE

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: In alcohol withdrawal, fixed doses of benzodiazepine are generally recommended as a first-line pharmacologic approach. This study determines the benefits of an individualized treatment regimen on the quantity of benzodiazepine administered and the duration of its use during alcohol withdrawal treatment. METHODS: We conducted a prospective, randomized, double-blind, controlled trial including 117 consecutive patients with alcohol dependence, according to the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, entering an alcohol treatment program at both the Lausanne and Geneva university hospitals, Switzerland. Patients were randomized into 2 groups: (1) 56 were treated with oxazepam in response to the development of signs of alcohol withdrawal (symptom-triggered); and (2) 61 were treated with oxazepam every 6 hours with additional doses as needed (fixed-schedule). The administration of oxazepam in group 1 and additional oxazepam in group 2 was determined using a standardized measure of alcohol withdrawal. The main outcome measures were the total amount and duration of treatment with oxazepam, the incidence of complications, and the comfort level. RESULTS: A total of 22 patients (39%) in the symptom-triggered group were treated with oxazepam vs 100% in the fixed-schedule group (P<.001). The mean oxazepam dose administered in the symptom-triggered group was 37.5 mg compared with 231.4 mg in the fixed-schedule group (P<.001). The mean duration of oxazepam treatment was 20.0 hours in the symptom-triggered group vs 62.7 hours in the fixed-schedule group (P<.001). Withdrawal complications were limited to a single episode of seizures in the symptom-triggered group. There were no differences in the measures of comfort between the 2 groups. CONCLUSIONS: Symptom-triggered benzodiazepine treatment for alcohol withdrawal is safe, comfortable, and associated with a decrease in the quantity of medication and duration of treatment.