1000 resultados para determinação de preço
Resumo:
Capillary electrophoresis (CE) encompasses a number of characteristics quite suitable for the simultaneous analysis of small ions such as high efficiency and resolving power, directly associated to its impressively high peak capacity, and short analysis time. In appropriate conditions, it is possible to perform the separation of approximately 36 anions in less than 3 minutes. In this work, the mechanisms by which anion analysis is performed was criteriously discussed, and a thorough review of the literature in the past 5 years, focusing mostly in applications of CE to anion analysis in real matrices, was presented.
Resumo:
Results of two intercomparison exercises are reported. In the first one, the participants were asked to determine Cd, Cu, Pb and Zn, at the sub mg mL-1 level, in an acidified aqueous solution. In the second one, the participants were asked to determine mercury (total) in two homogeneous biological samples, hair and fish. The exercises were considered satisfactory and few reported results were discharged (3s criteria).
Resumo:
A flow system procedure for spectrophotometric determination of ascorbic acid in drugs based on [Fe3+(SCN-)n]+3-n complex decomposition by reduction is described. The flow network was constituted by a set of three-way solenoid valves, controlled by a microcomputer running a software wrote in QuickBasic 4.5 language. The feasibility of the procedure was ascertained by determining ascorbic acid in drug samples with mass ranging from 0.0018 up to 0.0180 g. The results showed an agreement of about 7% when compared with recommended method. Other profitable features such as a standard deviation of 1.5% (n = 7) and a throughput of 120 determinations per hour was also achieved.
Resumo:
In this way it is very important to know the sulfate concentration in vinasse samples before to make the biodigestor design. A previous developed and indirect method (Anal. Chim. Acta. 1996, 329, 197), was used to determine sulfate in samples of vinasse, after previous treatments, done in order to eliminate organic matter with hydrogen peroxide 30% and concentrated nitric acid mixture (3:1), under heating. Interferent cationic ions were isolated by using ion exchange columns. The results obtained for some samples from Araraquara and Penápolis are here presented. The phosphate concentration was also determined.
Resumo:
A method for the determination of phosphorus in steel samples by graphite furnace atomic absorption spectrometry, using the Zeeman effect background correction and the STPF conditions is proposed. The effect of iron (III) on the phosphorus signal was studied. It was verified, through the pyrolysis temperature curves, that iron (III) is an efficient chemical modifier, thermically stabilizing phosphorus up to 1400ºC. The phosphorus signal increases with the iron (III) concentration, but in the range, which corresponds to the usual concentrations of iron in the sample solutions, the increase is small. Phosphorus was determined in three standard reference materials, after its dissolution in a mixture of hydrochloric and perchloric acids in a PTFE bomb. The agreement with the certified concentration values was excellent. Iron (III) was added to the reference analytical solutions prepared in the blank of the dissolution, while the sample solutions were measured directly, since they already contained the modifier. The detection limit (k = 2) was 0.0042% of phosphorus in the steel sample.
Resumo:
The simultaneous determination of cobalt and nickel is a classical analytical problem. A great number of reagents associated with several techniques of analysis have been applied to achieve this determination. In this review 117 references, which appeared between 1996-1980, are described and classified according to the technique applied.
Resumo:
It was identified and quantified several organic compounds in the atmosphere of a site into Amazon Basin with high impact of biomass burning emission. It was important to know the particulate matter composition with respect to n-alkanes and PAH associated with the particulate matter because they provided indication on the main sources contributing to airborne particles, the contribution of natural vs. man-made emission and the aging of the particles. The main classes of compounds observed were n-alkanes, PAH and nitro-PAH. It was observed the formation of nitro-PAH from photochemical reactions. The aerosol mass concentration is mainly associated with fluoranthene, pyrene and benzo(ghi)perylene. Environmental and direct emissions samples (flaming and smoldering) were collected and analysed.
Resumo:
The present work describes a rapid and sensitive method for the determination of carbon monoxide and carbon dioxide at low concentration levels, on line, in ethylene and hydrogen lines. These gases were separated in a column filled with Porapak Q, converted to methane and quantified by a flame ionization detector. Some modifications were made in the injection system and in the lines of the carrier gas. The detection limits of 2,6 ppbV and 4,85 ppbV for CO and CO2, respectively, were reached after modifications.
Resumo:
Results on the optimization of analytical methods for the determination of phosphorus in phosphino-polycarboxylate (PPCA), used frequently as scale inhibitor during oil production, by ICP-AES and ICP-MS are presented. Due to the complex matrix of production waters (brines) and their high concentration in inorganic phosphorus, the separation of organic phosphorus prior to its determination is necessary. In this work, minicolumns of silica immobilized C18 were used. Optimization of the separation step resulted in the following working conditions: (1) prewashing of the column with methanol (80% v/v); (2) use of a flow rate of 5 mL/min and 10 mL/min, respectively, for the preconditioning step and for percolation of the water sample; (3) final elution of organic phosphorus with 7 mL of buffer of H3BO3/NaOH (0.05 M, pH 9) with a flow rate of 1 mL/min. Sample detection limits (3s) for different combinations of nebulizers and spectrometric methods, based on 10 mL water aliquots, are: ICP-AES -Cross flow (47 mg/L) and Ultrasonic (18 mug/L); ICP-MS -Cross flow (1.2 mug/L), Cyclonic (0.7 mug/L) and Ultrasonic (0.5 mug/L). Typical recoveries of organic phosphorus are between 90 and 95% and the repeatability of the whole procedure is better than 10%. The developed methodology was applied successfully to samples from the oil-well NA 46, platform PNA 2, Campos basin, Brazil. Assessment of the PPCA inhibitor was possible at lower concentrations than achieved by current analytical methods, resulting in benefits such as reduced cost of chemicals, postponed oil production and lower environmental impacts.
Resumo:
A new method for determination of potassium in honey samples of different colors was developed as an alternative method for determination of this metal. Analysis of genuine honeys attested by the qualities and quantities tests officially adopted in Brazil, showed that the concentration of potassium ranged from 181 to 315 mg/kg for light honeys, from 393 to 570 mg/kg for medium honeys and from 791 to 915 mg/kg for dark honeys. Recoveries making use of spikes of potassium added to the honey samples and to the deionized distilled water showed results close by hundred percent at pH <= 2,0 under temperature bellow 20°C.
Resumo:
The classical volumetric titration of Fe2+ with MnO4-, used in some routine analysis as well as in undergraduate courses was improved. SnCl2 (to reduce Fe3+ to Fe2+) and HgCl2 (to oxidize excess SnCl2) were substituted by metallic zinc in boiling solutions, thus avoiding the toxic HgCl2 and Hg2Cl2; nitrate ions do not interfere in the improved methodology (it is an interference in the classical one) and the reproducibility of the determinations is increased by using metallic zinc. Determinations by students of undergraduate courses are discussed.
Resumo:
Spectrophotometric determination of total protein is used in several areas such as clinical analysis, food science and technology, biochemistry, protein chemistry, physiology. Five spectrophotometric methods are mostly used: biuret, Lowry, Bradford, Smith and UV absorption. In this review a general overview of these methods is presented (interferences, applications); other methodologies are also discussed.
Resumo:
Selectivity studies for the determination of Cr(VI) using the catalytic oxidation of the o-dianisidine by hydrogen peroxide showed two distincts situations. In the first, when interferents were studied by a univariate procedure, Cr(III) and Cu(II) cause serious interferences even at the 2:1 proportion, relative to Cr(VI), while Fe(III) interfered at the 15:1 ratio and EDTA at the 10:1 ratio. On the other hand, when a multivariate investigation was performed, Cr(III) did not present any significant principal effects and its significant interaction effects were negative, in contrast to EDTA, that presented positive interaction effects although, like Cr(III), did not show significant interaction effects. In view of the interferent's action it become necessary to separate Cr(VI) by extraction with methylisobutylketone in a chloridric acid medium before its determination in vegetals and in wastewater from a cellulose industry samples. Using this procedure, the method precision is ±0,5% at the 10 ng/mL Cr(VI) concentration level. The detection and quantification limits, calculated by means of absorbance measurements of ten replicates of blank reagents were 1,1 and 3,2 ng/mL, respectively. The results obtained with real samples showed a relative standard deviation between 1,2% and 3,0% relative to their reference values.
Resumo:
Cr(III) slowly forms a violet complex with EDTA at pH 2.5-5.0 under normal conditions. The complex formation can be accelerated by irradiating the reacting mixture with microwave energy. The complex Cr(III)-EDTA is completely formed within 3 minutes of microwave irradiation and followed by a simple and rapid method for spectrophotometric determination of chromium. The method may be successfully applied to determination of chromium in catalyst.
Resumo:
Solid-phase microextraction (SPME) has been applied to direct extraction of 11 organophosphorus pesticides in water using a 100 mm fiber polydimethylsiloxane. The method was evaluated with respect time of exposure, detection limits (LODs), linearity and precision. The detection limits (S/N = 3) depend of each pesticide and varie about ng/L levels. The linearity was satisfactory with coefficients of correlation usually greater than 0.993. The precision of the method was determined by extraction from 4.0 mg/L aqueous standard with coefficients of variation between 5.7 to 17.2%.