967 resultados para bioanalytical method validation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An accurate, sensitive, precise and rapid reversed-phase high-performance liquid chromatographic method was successfully developed and validated for the determination of caffeic acid (CA) in emulsions. The best separation was achieved on a 250 × 4.6 mm, 5.0 µm particle size RP18 XDB Waters column using ethanol and purified water (40:60 v/v) adjusted to pH 2.5 with acetic acid as the mobile phase at a flow rate of 0.7 mL/min. Ultraviolet detection was performed at 325 nm at ambient column temperature (25°C). The method was linear over the concentration range of 10-60 µg/mL (r(2) = 0.9999) with limits of detection and quantification of 1.44 and 4.38 µg/mL, respectively. CA was subjected to oxidation, acid, base and neutral degradation, as well as photolysis and heat as stress conditions. There were no interfering peaks at or near the retention time of CA. The method was applied to the determination of CA in standard and pharmaceutical products with excellent recoveries. The method is applicable in the quality control of CA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A reversed-phase high performance liquid chromatography method was validated for the determination of cefazolin sodium in lyophilized powder for solution for injection to be applied for quality control in pharmaceutical industry. The liquid chromatography method was conducted on a Zorbax Eclipse Plus C18 column (250 x 4.6 mm, 5 μm), maintained at room temperature. The mobile phase consisted of purified water: acetonitrile (60: 40 v/v), adjusted to pH 8 with triethylamine. The flow rate was of 0.5 mL min-1 and effluents were monitored at 270 nm. The retention time for cefazolin sodium was 3.6 min. The method proved to be linear (r2 =0.9999) over the concentration range of 30-80 µg mL-1. The selectivity of the method was proven through degradation studies. The method demonstrated satisfactory results for precision, accuracy, limits of detection and quantitation. The robustness of this method was evaluated using the Plackett–Burman fractional factorial experimental design with a matrix of 15 experiments and the statistical treatment proposed by Youden and Steiner. Finally, the proposed method could be also an advantageous option for the analysis of cefazolin sodium, contributing to improve the quality control and to assure the therapeutic efficacy

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study is to develop and validate a dissolution test for fluconazole, an antifungal used for the treatment of superficial, cutaneous, and cutaneomucous infections caused by Candida species, in capsules dosage form. Techniques by HPLC and UV first derivative spectrophotometry (UV-FDS) were selected for quantitative evaluation. In the development of release profile, several conditions were evaluated. Dissolution test parameters were considered appropriate when a most discriminative release profile for fluconazole capsules was yielded. Dissolution test conditions for fluconazole capsules were 900 mL of HCl 0.1 M, 37 ± 0.5 °C using baskets with 50 rpm for 30 min of test. The developed HPLC and UV-FDS methods for the antifungal evaluation were selective and met requirements for an appropriate and validated method, according to ICH and USP requirements. Both methods can be useful in the registration process of new drugs or their renewal. For routine analysis application cost, simplicity, equipment, solvents, speed, and application to large or small workloads should be observed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The doxycycline (DOX) is a broad-spectrum antibiotic used in several countries. This drug is part of the list of medicines to the SUS (Unified Health System), a model of health care in Brazil. This study describes the development and validation of a microbiological assay, applying the turbidimetric method for the determination of DOX, as well as the evaluation of the ability of the method in determining the stability of DOX in tablets against acidic and basic hydrolysis, photolytic and oxidative degradations, using Escherichia coli ATCC 10536 as micro-organism test and 3×3 parallel line assay design, with nine tubes for each assay, as recommended by the Brazilian Pharmacopoeia. The developed and validated method showed excellent results of linearity, selectivity, precision, accuracy and robustness. The assay is based on the inhibitory effect of DOX using Escherichia coli ATCC 10536. The results of the assay were treated by analysis of variance and were found to be linear (r= 0.9986) in the range from 4.0 to 9.0μg/mL, precise (repeatability R.S.D.= 0.99 and intermediate precision was confirmed by statistical analysis the mean values obtained from analysis by different analysts) and exact (97.73%). DOX solution exposed to direct UV light, alkaline and acid hydrolysis and hydrogen peroxide causing oxidation were used to evaluate the specificity of the bioassay. Comparison of bioassay and liquid chromatography showed differences in results between methodologies. The results showed that the bioassay is valid, simple and useful alternative methodology for DOX determination in routine quality control.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the importance of an innovative analytical technique for drugs and pharmaceuticals quantification, using Fouriertransform infrared (FTIR) transmission spectroscopy. This method does not use organic solvents, which is one great advantage over the most common analytical methods. This fact contributes to minimize the generation of organic solvent waste by the industry and thereby reduces the impact of its activities on the environment. The method involved absorbance measurements of the band corresponding to one of the chosen group in the molecule. Obviously, the method should be validated according to ICH guidelines, showing linearity, precision, accuracy and robustness, over a concentration range, using small amounts to prepare the analyte. The validated method is able to quantify drugs and pharmaceuticals and can be used as an environmentally friendly alternative for the routine analysis in pharmaceutical industry quality control.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Flucloxacillin sodium (FLU) is a semi-synthetic penicillin active against many gram-positive bacteria such as streptococci and penicilinase-producing staphylococci, including methicillin-susceptible S. aureus. This study describes the development and validation of a microbiological assay, applying the diffusion agar method for the determination of FLU, as well as the evaluation of the ability of the method in determining the stability of FLU in capsules against acidic and basic hydrolysis, photolytic and oxidative degradations, using S. aureus ATCC 25923 as micro-organism test and 3 x 3 parallel line assay design (three doses of the standard and three doses of the sample in each plate), with six plates for each assay, according to the Brazilian Pharmacopoeia. The validation method showed good results including linearity, precision, accuracy, robustness and selectivity. The assay is based on the inhibitory effect of FLU using Staphylococcus aureus ATCC 25923. The results of the assay were treated by analysis of variance (ANOVA) and were found to be linear (r = 0.9997) in the range from 1.5 to 6.0 μg/mL, precise (repeatability: R.S.D. = 1.63 and intermediate precision: R.S.D. = 1.64) and accurate (98.96%). FLU solution (from the capsules) exposed to direct UVC light (254 nm), alkaline and acid hydrolysis and hydrogen peroxide causing oxidation were used to evaluate the specificity of the bioassay. Comparison of bioassay and liquid chromatography by ANOVA showed no difference between methodologies. The results demonstrated the validity of the proposed bioassay, which is a simple and useful alternative methodology for FLU determination in routine quality control.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High intake of saturated fat from meats has been associated with cardiovascular disease, cancer, diabetes, and others diseases. In this paper, we are introducing a simple, high-throughput, and non-destructive low-resolution nuclear magnetic resonance method that has the potential to analyze the intramuscular fat content (IMF) in more than 1,000 beef portions per hour. The results can be used in nutritional fact labels, replacing the currently used average value. The method is based on longitudinal (T(1)) and transverse (T(2)) relaxation time information obtained by a continuous wave-free precession (CWFP) sequence. CWFP yields a higher correlation coefficient (r=0.9) than the conventional Carr-Purcell-Meiboom- Gill (CPMG) method (r=-0.25) for IMF in beef and is just as fast and a simpler pulse sequence than CPMG. The method can also be applied to other meat products.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To assess topical delivery studies of glycoalkaloids, an analytical method by HPLC-UV was developed and validated for the determination of solasonine (SN) and solamargine (SM) in different skin layers, as well as in a topical formulation. The method was linear within the ranges 0.86 to 990.00 mu g/mL for SN and 1.74 to 1000.00 mu g/mL for SM (r = 0.9996). Moreover, the recoveries for both glycoalkaloids were higher than 88.94 and 93.23% from skin samples and topical formulation, respectively. The method developed is reliable and suitable for topical delivery skin studies and for determining the content of SN and SM in topical formulations.