The use of Ga-Au alloys of different compositions as metal catalysts for the growth of abrupt SiGe/Si nanowire axial heterostructures has been investigated. The heterostructures grown in a continuous process by just switching the gas precursors, show uniform nanowire diameters, almost abrupt compositional changes and no defects between the different sections. These features represent significant improvements over the results obtained using pure Au.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, a theoretical criterion to calculate the stability of an axial-flow compressor rotor has been presented in the scientific literature. This theoretical criterion was used for determining the locus of the stability line over the rotor map and for predicting the post-stall evolution of the constant-speed line of a rotor. The main objective of this paper is to improve the predictions of such a model. To do that, the paper proposes a different characterization of the characteristic azimuthal length and a calculation of the ratio of specific heats based on a polytropic exponent. Thanks to these new values, the model predicts two bifurcation points in the behaviour of the flow: the inception point of the instability and the surge point. Experimental data from a pure axial compressor are used to validate the model showing that the prediction of the flow coefficient at the surge point has an error inferior to 5%. For the rotor studied, the paper provides a quantitative and qualitative description of the inception of the instability and of the mechanism involved in the instable region of the compressor map. The paper also discusses the role of rotor efficiency in the position of the bifurcations and gives a sensitivity analysis of its position. Finally, it presents a discussion about how the model can explain the different behaviours exhibited by the same rotor when the flow coefficient is reduced

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En este artículo se presenta la aplicación del Método de los Elementos de Contorno a la determinación del campo de desplazamientos y tensiones de sistemas axisimétricos en régimen elástico. Desarrollando asimismo, un procedimiento para la determinación de los coeficientes de las matrices de influencia que aparecen en el tratamiento numérico del problema. El estudio del estado tensional del sistema axisimétrico es de obvio interés en Ingeniería, pudiendo citarse entre otras las siguientes aplicaciones: estudio de vasijas de todo tipo, y cobrando plena actualidad las vasijas de los reactores nucleares; efecto de grietas y entallas; efecto de la colocación de zunchos de pretensado en depósitos de hormigon armado, etc. El tratamiento numérico de este tipo de problemas se produce como consecuencia de la dificultad de encontrar soluciones cerradas para las ecuaciones de campo que definen el problema, ecuaciones que aunque establecidas hace tiempo, sólo han sido resueltas en casos particulares. La ventaja de la utilización del M.E.C.,frente a los métodos de dominio, se pone de manifiesto en el estudio de este tipo de sistemas ya que la consideración de una malla monodimensional es suficiente para representar la discretización del contorno, produciendose una considerable reducción del tiempo de cómputo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The control of the SiGe NW composition is fundamental for the fabrication of high quality heterostructures. Raman spectroscopy has been used to analyse the composition of SiGe alloys. We present a study of the Raman spectrum of SiGe nanowires and SiGe/Si heterostructures. The inhomogeneity of the Ge composition deduced from the Raman spectrum is explained by the existence of a Ge-rich outer shell and by the interaction of the NW with the electromagnetic field associated with the laser beam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dynamics of inviscid, axisymmetric liquid bridges permits a simplified treatment if the bridge is long enough. Under such condition the evolution of the liquid zone is satisfactorily explained through a non-linear one-dimensional model. In the case of breaking, the one-dimensional model fails when the neck radius of the liquid column is close to zero; however, the model allows the calculation of the time variation of the liquid-bridge interface as well as of the fluid velocity field and, because the last part of the evolution is not needed, the overall results such as the breaking time and the volume of each of the two drops resulting after breakage can be calculated. In this paper numerical results concerning the behavior of clinical liquid bridges subjected to a small axial gravitational field are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper the influence of an axial microgravity on the minimum volume stability limit of axisymmetric liquid bridges between unequal disks is analyzed both theoretically and experimentally. The results here presented extend the knowledge of the static behaviour of liquid bridges to fluid configurations different from those studied up to now (almost equal disks). Experimental results, obtained by simulating microgravity conditions by the neutral buoyancy technique, are also presented and are shown to be in complete agreement with theoretical ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En el estudio de la propagación transversal de una radiación luminosa a través de un capilar con cristal líquido nemático, y cuyas moléculas se encuentran orientadas homeotrópicamente con respecto a las paredes internas de dicho capilar es necesario conocer de forma exacta la distribución espacial del director de cada una de las moléculas contenidas en el mismo. Esta distribución ha sido obtenida de forma empírica por Scudieri interpretando los resultados mediante la suposición de "lente delgada". Experimentalmente, mediante técnicas interferométricas, se obtienen dos grupos de franjas correspondiendo uno al índice de refraccción ordinario y siendo el otro función del ordinario y del extraordinario. El análisis de estas franjas es de una gran importancia a la hora de aplicar estructuras como la presente en Optica Integrada, ya que de ellas se puede inferir cuál es la respuesta de las moléculas de cristal líquido frente a campos externos, conocidos los valores del índice de refracción.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report identification of 9-cis-4-oxo-retinoic acid (9-cis-4-oxo-RA) as an in vivo retinoid metabolite in Xenopus embryos. 9-Cis-4-oxo-RA bound receptors (RARs) α, β, and γ as well as retinoid X receptors (RXRs) α, β, and γ in vitro. However, this retinoid displayed differential RXR activation depending on the response pathway used. Although it failed to activate RXRs in RXR homodimers, it activated RXRs and RARs synergistically in RAR-RXR heterodimers. 9-Cis-4-oxo-RA thus acted as a dimer-specific agonist. Considering that RAR-RXR heterodimers are major functional units involved in transducing retinoid signals during embryogenesis and that 9-cis-4-oxo-RA displayed high potency for modulating axial pattern formation in Xenopus, metabolism to 9-cis-4-oxo-RA may provide a mechanism to target retinoid action to this and other RAR-RXR heterodimer-mediated processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os motores de corrente contínua convencionais são muito bem conhecidos pela sua robustez e pelo seu alto nível de controlabilidade, alem do fato de possibilitarem a operação na região de enfraquecimento de campo (modo motor), quando esta situação se fizer necessária. Por estas características, as máquinas de corrente contínua ainda são empregadas nos dias atuais em nichos específicos de utilização. Não obstante, a máquina c.c. apresenta algumas desvantagens, principalmente a intensiva e dispendiosa manutenção eletromecânica necessária para sua operação. Como opção de sanar este problema, surgiram na década de 60, as máquinas elétricas de corrente contínua sem escovas (brushless) com excitação por ímãs permanentes de fluxo trapezoidal. O problema destas máquinas se deve justamente a impossibilidade da variação de fluxo de excitação uma vez que são produzidos puramente pelos ímãs. Sendo assim, este trabalho tem como propósito, o estudo de topologias diferenciadas da máquina elétrica, através de um circuito magnético não convencional para aplicação e utilização em sistemas de tração elétrica para operação na região de enfraquecimento de campo através da variação do fluxo resultante no entreferro. Como objeto de estudo, foi focada a topologia de fluxo axial com excitação híbrida, ou seja, dupla excitação (excitação a ímãs permanentes e excitação elétrica). Para o projeto da topologia proposta, nesta tese, adicionalmente ao método analítico, foram realizadas simulações computacionais para a comparação e refinamento dos resultados das grandezas eletromagnéticas da máquina.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reatores tubulares de polimerização podem apresentar um perfil de velocidade bastante distorcido. Partindo desta observação, um modelo estocástico baseado no modelo de dispersão axial foi proposto para a representação matemática da fluidodinâmica de um reator tubular para produção de poliestireno. A equação diferencial foi obtida inserindo a aleatoriedade no parâmetro de dispersão, resultando na adição de um termo estocástico ao modelo capaz de simular as oscilações observadas experimentalmente. A equação diferencial estocástica foi discretizada e resolvida pelo método Euler-Maruyama de forma satisfatória. Uma função estimadora foi desenvolvida para a obtenção do parâmetro do termo estocástico e o parâmetro do termo determinístico foi calculado pelo método dos mínimos quadrados. Uma análise de convergência foi conduzida para determinar o número de elementos da discretização e o modelo foi validado através da comparação de trajetórias e de intervalos de confiança computacionais com dados experimentais. O resultado obtido foi satisfatório, o que auxilia na compreensão do comportamento fluidodinâmico complexo do reator estudado.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate choroidal thickness in young subjects using Enhanced Depth Imaging Spectral Domain Optical Coherence Tomography (EDI SD-OCT) describing volume differences between all the defined areas of the Early Treatment Diabetic Retinopathy Study (ETDRS). Design: Prospective, clinical study. Methods: Seventy-nine eyes of 95 healthy, young (23.8±3.2years), adult volunteers were prospectively enrolled. Manual choroidal segmentation on a 25-raster horizontal scan protocol was performed. The measurements of the nine subfields defined by the ETDRS were evaluated. Results: Mean subfoveal choroidal thickness was 345.67±81.80μm and mean total choroidal volume was 8.99±1.88mm3. Choroidal thickness and volume were higher at the superior and temporal areas compared to inferior and nasal sectors of the same diameter respectively. Strong correlations between subfoveal choroidal thickness and axial length (AL) and myopic refractive error were obtained, r = -0.649, p<0.001 and r = 0.473, p<0.001 respectively. Emmetropic eyes tended to have thicker subfoveal choroidal thickness (381.94±79.88μm versus 307.04±64.91μm) and higher total choroidal volume than myopic eyes (9.80± 1.87mm3 versus 8.14±1.48mm3). The estimation of the variation of the subfoveal choroidal thickness with the AL was-43.84μm/mm. In the myopic group, the variation of the subfoveal choroidal thickness with the myopic refractive error was -10.45μm/D. Conclusions: This study establishes for the first time a normal database for choroidal thickness and volume in young adults. Axial length, and myopic ammetropy are highly associated with choroidal parameters in healthy subjects. EDI SD-OCT exhibited a high degree of intraobserver and interobserver repeatability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the relationship between different ocular and corneal biomechanical parameters in emmetropic and ametropic healthy white children. Methods: This study included 293 eyes of 293 healthy Spanish children (135 boys and 158 girls), ranging in age from 6 to 17 years. Subjects were divided according to the refractive error: control (emmetropia, 99 children), myopia (100 children), and hyperopia (94 children) groups. In all cases, corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer system. Axial length (AL) and mean corneal power were also measured by partial coherence interferometry (IOLMaster), and central corneal thickness (CCT) and anterior chamber depth were measured by anterior segment optical coherence tomography (Visante). Results: Mean (±SD) CH and CRF were 12.12 (±1.71) and 12.30 (±1.89) mm Hg, respectively. Mean (±SD) CCT was 542.68 (±37.20) μm and mean (±SD) spherical equivalent was +0.14 (±3.41) diopters. A positive correlation was found between CH and CRF (p < 0.001), and both correlated as well with CCT (p < 0.0001). Corneal resistance factor was found to decrease with increasing age (p = 0.01). Lower levels of CH were associated with longer AL and more myopia (p < 0.001 and p = 0.001, respectively). Higher values of CH were associated with increasing hyperopia. Significant differences in CH were found between emmetropic and myopic groups (p < 0.001) and between myopic and hyperopic groups (p = 0.011). There were also significant differences in CRF between emmetropic and myopic groups (p = 0.02). Multiple linear regression analysis showed that lower CH and CRF significantly associated with thinner CCT, longer AL, and flatter corneal curvature. Conclusions: The Ocular Response Analyzer corneal biomechanical properties seem to be compromised in myopia from an early age, especially in high myopia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de mestrado, Nutrição Clínica, Faculdade de Medicina, Universidade de Lisboa, 2015