1000 resultados para X(3872)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently, modern cross-sectional imaging techniques such as multi-detector computed tomography (MDCT) have pioneered post mortem investigations, especially in forensic medicine. Such approaches can also be used to investigate bones non-invasively for anthropological purposes. Long bones are often examined in forensic cases because they are frequently discovered and transferred to medico-legal departments for investigation. To estimate their age, the trabecular structure must be examined. This study aimed to compare the performance of MDCT with conventional X-rays to investigate the trabecular structure of long bones. Fifty-two dry bones (24 humeri and 28 femora) from anthropological collections were first examined by conventional X-ray, and then by MDCT. Trabecular structure was evaluated by seven observers (two experienced and five inexperienced in anthropology) who analyzed images obtained by radiological methods. Analyses contained the measurement of one quantitative parameter (caput diameter of humerus and femur) and staging the trabecular structure of each bone. Preciseness of each technique was indicated by describing areas of trabecular destruction and particularities of the bones, such as pathological changes. Concerning quantitative parameters, the measurements demonstrate comparable results for the MDCT and conventional X-ray techniques. In contrast, the overall inter-observer reliability of the staging was low with MDCT and conventional X-ray. Reliability increased significantly when only the results of the staging performed by the two experienced observers were compared, particularly regarding the MDCT analysis. Our results also indicate that MDCT appears to be better suited to a detailed examination of the trabecular structure. In our opinion, MDCT is an adequate tool with which to examine the trabecular structure of long bones. However, adequate methods should be developed or existing methods should be adapted to MDCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT : Background : The aim of this study was to evaluate the midterm biocompatibility of a new x-shaped implant made of zirconium in an animal model of glaucoma surgery. Methods : Preoperatively, ultrasound biomicroscopy (UBM), intraocular pressure (IOP) and outflow facility (OF) data were acquired. Upon surgery, one eye was chosen randomly to receive an implant, while the other received none. Ten rabbits went through a 1-, 2-, 3-, 4- and 6-month follow-up. [OP was measured regularly, UBM performed at 1, 3 and 6 months after surgery. At the end of the follow-up, OF was again measured. Histology sections were analyzed. Results : For both groups IOP control was satisfactory, while OF initially increased at month 1 to resume preoperative values thereafter. Eyes with implants had larger filtration blebs which decreased faster than in eyes without the implant. Drainage vessel density, inflammatory cell number and fibrosis were higher in tissues near the implant. Conclusions : The zirconium implant initially promoted the positive effects of the surgery (IOP control, OF increase). Nevertheless, after several months, foreign body reactions and fibrosis had occurred on some implants that restrained the early benefit of such a procedure. Modifications of the zirconium implant geometry could enhance the overall success rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Molar heat capacities of the binary compounds NiAl, NiIn, NiSi, NiGe, NiBi, NiSb, CoSb and FeSb were determined every 10 K by differential scanning calorimetry in the temperature range 310-1080 K. The experimental results have been fitted versus temperature according to C-p = a + b . T + c . T-2 + d . T-2. Results are given, discussed and compared to estimations found in the literature. Two compounds, NiBi and FeSb, are subject to transformations between 460 and 500 K. (C) 1999 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We communicate a detailed study of the epitaxial growth of CeO2 on MgO. The key feature of the growth is the dependence of the in¿plane orientation of the CeO2 epitaxial layer on the MgO surface morphology. Atomic force microscopic (AFM) measurements, x¿ray analyses, as well as high¿resolution transmission electron microscopy (HRTEM) investigations reveal that on rough substrates a cube¿on¿cube growth of CeO2 on MgO occurs while on smooth substrates the CeO2 unit cell is rotated around the surface normal by 45° with respect to the MgO unit cell when the deposition rate is low (~0.3 Å/s) during the first stages of growth. This growth mechanism can be used for a defined fabrication of 45° grain boundaries in the CeO2 layer by controlling the surface roughness of the MgO substrate. This report demonstrates that these 45° grain boundaries may be used to fabricate YBa2Cu3O7¿x Josephson junctions.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peripheral assessment of bone density using photon absorptiometry techniques has been available for over 40 yr. The initial use of radio-isotopes as the photon source has been replaced by the use of X-ray technology. A wide variety of models of single- or dual-energy X-ray measurement tools have been made available for purchase, although not all are still commercially available. The Official Positions of the International Society for Clinical Densitometry (ISCD) have been developed following a systematic review of the literature by an ISCD task force and a subsequent Position Development Conference. These cover the technological diversity among peripheral dual-energy X-ray absorptiometry (pDXA) devices; define whether pDXA can be used for fracture risk assessment and/or to diagnose osteoporosis; examine whether pDXA can be used to initiate treatment and/or monitor treatment; provide recommendations for pDXA reporting; and review quality assurance and quality control necessary for effective use of pDXA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we present a new method to track bonemovements in stereoscopic X-ray image series of the kneejoint. The method is based on two different X-ray imagesets: a rotational series of acquisitions of the stillsubject knee that will allow the tomographicreconstruction of the three-dimensional volume (model),and a stereoscopic image series of orthogonal projectionsas the subject performs movements. Tracking the movementsof bones throughout the stereoscopic image series meansto determine, for each frame, the best pose of everymoving element (bone) previously identified in the 3Dreconstructed model. The quality of a pose is reflectedin the similarity between its simulated projections andthe actual radiographs. We use direct Fourierreconstruction to approximate the three-dimensionalvolume of the knee joint. Then, to avoid the expensivecomputation of digitally rendered radiographs (DRR) forpose recovery, we reformulate the tracking problem in theFourier domain. Under the hypothesis of parallel X-raybeams, we use the central-slice-projection theorem toreplace the heavy 2D-to-3D registration of projections inthe signal domain by efficient slice-to-volumeregistration in the Fourier domain. Focusing onrotational movements, the translation-relevant phaseinformation can be discarded and we only consider scalarFourier amplitudes. The core of our motion trackingalgorithm can be implemented as a classical frame-wiseslice-to-volume registration task. Preliminary results onboth synthetic and real images confirm the validity ofour approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fragile X syndrome (FXS) is characterized by intellectual disability and autistic traits, and results from the silencing of the FMR1 gene coding for a protein implicated in the regulation of protein synthesis at synapses. The lack of functional Fragile X mental retardation protein has been proposed to result in an excessive signaling of synaptic metabotropic glutamate receptors, leading to alterations of synapse maturation and plasticity. It remains, however, unclear how mechanisms of activity-dependent spine dynamics are affected in Fmr knockout (Fmr1-KO) mice and whether they can be reversed. Here we used a repetitive imaging approach in hippocampal slice cultures to investigate properties of structural plasticity and their modulation by signaling pathways. We found that basal spine turnover was significantly reduced in Fmr1-KO mice, but markedly enhanced by activity. Additionally, activity-mediated spine stabilization was lost in Fmr1-KO mice. Application of the metabotropic glutamate receptor antagonist α-Methyl-4-carboxyphenylglycine (MCPG) enhanced basal turnover, improved spine stability, but failed to reinstate activity-mediated spine stabilization. In contrast, enhancing phosphoinositide-3 kinase (PI3K) signaling, a pathway implicated in various aspects of synaptic plasticity, reversed both basal turnover and activity-mediated spine stabilization. It also restored defective long-term potentiation mechanisms in slices and improved reversal learning in Fmr1-KO mice. These results suggest that modulation of PI3K signaling could contribute to improve the cognitive deficits associated with FXS.