994 resultados para Vertical displacement measurement
Resumo:
Dissertation for the degree of Doctor of Philosophy in Physics
Resumo:
Adhesive bonding is an excellent alternative to traditional joining techniques such as welding, mechanical fastening or riveting. However, there are many factors that have to be accounted for during joint design to accurately predict the joint strength. One of these is the adhesive layer thickness (tA). Most of the results are for epoxy structural adhesives, tailored to perform best with small values of tA, and these show that the lap joint strength decreases with increase of tA (the optimum joint strength is usually obtained with tA values between 0.1 and 0.2 mm). Recently, polyurethane adhesives were made available in the market, designed to perform with larger tA values, and whose fracture behaviour is still not studied. In this work, the effect of tA on the tensile fracture toughness (View the MathML source) of a bonded joint is studied, considering a novel high strength and ductile polyurethane adhesive for the automotive industry. This work consists on the fracture characterization of the bond by a conventional and the J-integral techniques, which accurately account for root rotation effects. An optical measurement method is used for the evaluation of crack tip opening (δn) and adherends rotation at the crack tip (θo) during the test, supported by a Matlab® sub-routine for the automated extraction of these parameters. As output of this work, fracture data is provided in traction for the selected adhesive, enabling the subsequent strength prediction of bonded joints.
Resumo:
Introdução: O rastreio sistemático para infecções de transmissão vertical durante a gravidez permite melhorar o prognóstico e o seguimento dos doentes eventualmente afectados e facilita o raciocínio do pediatra ou neonatologista. Objectivo: Avaliar a imunidade materna e a evolução nos últimos anos e a estudar a influência da idade e da nacionalidade no estado imunológico para estas doenças. Métodos e doentes: Estudo não probabilístico de prevalência de imunidade e infecção durante a gravidez. Dados obtidos dos processos clínicos dos recém-nascidos da Maternidade do Hospital (Abril, 2004-Diciembro, 2009). Resultados: Em 3162 mulheres recolheram-se 9508 resultados de serología 2639 resultados de rastreio para Streptococcus do grupo B (SGB). A taxa de imunidade para rubéola foi 93,3%, significativamente mais elevada em mães portuguesas e também mais elevada que no período 1988-95; para a toxoplasmosis foi 25,7%, superior nos grupos de mães com mais idade e entre estrangeiras e mais baixa que no período 1988-95; foi encontrada IgG positiva para virus citomegálico humano (CMV) em 62,4% das mulheres. No período 1988-95 era de 85%. As provas não treponémicas foram positivas em 0,5%. O AgHBs foi identificado em 2,3%, com taxa mais elevada entre as estrangeiras. Os anticorpos para o vírus da hepatite C e para o vírus da imunodeficiência humana foram encontrados respectivamente em 1,4% e 2,8% das mulheres rastreadas. Não forma diagnosticados casos de infecção congénita. A taxa de seroconversão para a Toxoplasmose diminuiu de 1988 para o período em estudo. O rastreio para o SGB revelou que 13,9% das mulheres eram portadoras. Conclusão: Em vinte e cinco anos foi possível identificar uma mudança importante na seroprevalência e taxa de seroconversão de algumas doenças infecciosas de transmissão vertical durante a gravidez.
Resumo:
Perinatal bacterial infection may be caused by any microorganism colonizing the vaginal tract. Neonatologists and paediatricians are especially concerned about group B Stretpococcus (GBS). However, Enterobactereacea, mainly E.coli and Proteus, are also responsible for infection. GBS screening may be accomplished in over 90% of pregnant women. In our maternity in 2007-2008, 85% of the mothers had been screened. Screening and prophylaxis were responsible for a decreasing incidence of neonatal infection - from 0.6/1000 to 0.15/1000 live births in Portugal, from 2002 to 2007. However there are some difficulties related to screening. In the second Portuguese study 16/57 NB with early-onset infection (28%) were born to “negative” mothers. Several factors illustrate how difficult is to draw national screening policies: a wide range of carrier’s state rate throughout a country - in Portugal from 12% to 30%. The success of any screening policy may also be affected by additional technical and organizational problems. In countries where home delivery is a tradition or a trend intrapartum GBS prophylaxis requires a very well organized assistance.. Moreover factors usually accepted as protective are not so effective. In the Portuguese study 24/57 infected newborns (42%) were delivery by caesarean section. Another subject deals with the workload in the postnatal ward generated by deficient compliance to the guidelines a problem not confirm by a study of our group. Decreasing the importance of GBS, highlight the importance of E. coli in perinatal infection. From the 16 340 registrations of the National Registry 1676 were newborns with mother-related infection. Applying the same reasoning to E.coli as to GBS and Listeria monocytogenes – that is considering all of them are of maternal origin - 6.7% of these infections were due to E. coli, 4.6% to SGB and 0.5% to Listeria monocytogenes. In conclusion screening and prophylaxis may be not the best way to prevent all GBS neonatal infections but by now it is the only available procedure. The other bacteria continue to demand a high suspicion level and immediate intervention.
Resumo:
Stone masonry is one of the oldest and most worldwide used building techniques. Nevertheless, the structural response of masonry structures is complex and the effective knowledge about their mechanical behaviour is still limited. This fact is particularly notorious when dealing with the description of their out-of-plane behaviour under horizontal loadings, as is the case of the earthquake action. In this context, this paper describes an experimental program, conducted in laboratory environment, aiming at characterizing the out-of-plane behaviour of traditional unreinforced stone masonry walls. In the scope of this campaign, six full-scale sacco stone masonry specimens were fully characterised regarding their most important mechanic, geometric and dynamic features and were tested resorting to two different loading techniques under three distinct vertical pre-compression states; three of the specimens were subjected to an out-of-plane surface load by means of a system of airbags and the remaining were subjected to an out-of-plane horizontal line-load at the top. From the experiments it was possible to observe that both test setups were able to globally mobilize the out-of-plane response of the walls, which presented substantial displacement capacity, with ratios of ultimate displacement to the wall thickness ranging between 26 and 45 %, as well as good energy dissipation capacity. Finally, very interesting results were also obtained from a simple analytical model used herein to compute a set of experimental-based ratios, namely between the maximum stability displacement and the wall thickness for which a mean value of about 60 % was found.
Resumo:
In the absence of intervention, the rate of vertical transmission of HIV can range from 15-45%. With the inclusion of antiretroviral drugs during pregnancy and the choice of delivery route this amounts to less than 2%. However ARV use during pregnancy has generated several questions regarding the adverse effects of the gestational and neonatal outcome. This study aims to analyze the risk factors for vertical transmission of HIV-1 seropositive pregnant women living in Rio Grande and the influence of the use of ARVs in pregnancy outcome. Among the 262 pregnant women studied the rate of vertical transmission of HIV was found to be 3.8%. Regarding the VT, there was a lower risk of transmission when antiretroviral drugs were used and prenatal care was conducted at the referral service. However, the use of ART did not influence the outcome of pregnancy. However, initiation of prenatal care after the first trimester had an influence on low birth weight, as well as performance of less than six visits increased the risk of prematurity. Therefore, the risk factors analyzed in this study appear to be related to the realization of inadequate pre-natal and maternal behavior.
Resumo:
A finding of vertical transmission of the DEN 3 virus in male specimens of Aedes aegypti, collected in the 2009 fall-winter period, in Puerto Iguazú city, Misiones, Argentina, using the RT-PCR technique in a 15-specimen pool is reported. This result is analyzed within the context of the epidemiological situation of Argentina's northeast border.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
A dissertação em apreço resultou da necessidade em otimizar os recursos técnicos, mas sobretudo humanos, afetos às verificações de instrumentos de medição, no âmbito do Controlo Metrológico Legal. Estas verificações, realizadas nos termos do cumprimento das competências outrora atribuídas à Direção de Serviços da Qualidade da então Direção Regional da Economia do Norte, eram operacionalizadas pela Divisão da Qualidade e Licenciamento, na altura dirigida pelo subscritor da presente tese, nomeadamente no que respeita aos ensaios efetuados, em laboratório, a manómetros analógicos. O objetivo principal do trabalho foi alcançado mediante o desenvolvimento de um automatismo, materializado pela construção de um protótipo, cuja aplicação ao comparador de pressão múltiplo, dantes em utilização, permitiria realizar a leitura da indicação de cada manómetro analógico através de técnicas de processamento de imagem, função esta tradicionalmente efetuada manualmente por um operador especializado. As metodologias de comando, controlo e medição desse automatismo foram realizadas através de um algoritmo implementado no software LabVIEW® da National Intruments, particularmente no que respeita ao referido processamento das imagens adquiridas por uma câmara de vídeo USB. A interface com o hardware foi concretizada recorrendo a um módulo de Aquisição de Dados Multifuncional (DAQ) USB-6212, do mesmo fabricante. Para o posicionamento horizontal e vertical da câmara de vídeo USB, recorreu-se a guias lineares acionadas por motores de passo, sendo que estes dispositivos foram igualmente empregues no acionamento do comparador de pressão. Por último, procedeu-se à aquisição digital da leitura do padrão, recorrendo à respetiva virtualização, bem como a uma aplicação desenvolvida neste projeto, designada appMAN, destinada à gestão global do referido automatismo, nomeadamente no que se refere ao cálculo do resultado da medição, erro e incerteza associada, e emissão dos respetivos documentos comprovativos.
Resumo:
O presente projeto foi realizado no âmbito da unidade curricular Dissertação/Estágio/Projeto, e desenvolve um estudo sobre as estruturas porticadas de sinalização vertical em Autoestradas, ao nível da estrutura metálica e das fundações, com o objetivo de analisar três casos diferentes com características distintas. Dois dos casos em estudo são modelos comuns que se encontram facilmente nas autoestradas. O terceiro tem uma configuração diferente, mais gravoso que o habitual. Com estes três casos obtém-se um estudo completo e abrangente deste tipo de estrutura porticada. Ao longo do projeto é seguida a norma EC3 (Eurocódigo 3 – Projeto de estruturas de aço). Dimensionaram-se as estruturas utilizando secções tubulares, mas é também realizado o dimensionamento de uma solução estrutural alternativa recorrendo a perfis laminados I ou H. As estruturas foram modeladas com recurso ao software de cálculo Autodesk Robot Structural Analysis Professional, obtendo-se os esforços e deformações nos vários pontos da estrutura, que permitem realizar o dimensionamento manual das secções dos perfis estruturais, chumbadouros, chapas de fundação e fundações propriamente ditas. Na parte final do projeto apresenta-se uma apreciação global do mesmo, conclusões gerais sobre os resultados obtidos e possíveis desenvolvimentos futuros.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
RESUMO - Introdução: A criação das Unidades Locais de Saúde (ULS) em Portugal reconheceu a necessidade de reorganização do sistema para responder a novas exigências, apostando no caminho da integração vertical e da prestação de cuidados globais. A primeira ULS foi criada em Portugal em 1999, actualmente existem sete. Objectivo: Analisar a influência do modelo organizacional dos prestadores no número e tipo de internamentos por causas sensíveis a cuidados de ambulatório (ICSCA). Metodologia: Foram determinados os ICSCA segundo a metodologia do Canadian Institute for Health Information e respectivas taxas padronizadas nos distritos das unidades seleccionadas, entre 2006 e 2010. Utilizou-se o método da diferença das diferenças para a comparação dos períodos pré e pós-ULS, utilizando como caso controle um distrito em que os prestadores estão organizados no modelo clássico, Hospitais+ACES. Resultados: Foram incluídos no estudo 4.446 ICSCA (6,27% do total de internamentos). Existiram em média 296,4 internamentos anuais por distrito, sendo a taxa média 252,7 int.100.000 hab. Após a criação da ULS 1 evitaram-se, em média, mais 36% internamentos (93,3 int. 100.000 hab.). Na ULS 2, pelo contrário, houve um acréscimo de 7% na taxa de internamento (17,6 int. 100.000 hab.). Discussão e conclusão: Não foi encontrado um padrão na variação nas taxas de ICSCA após a criação das ULS. Será necessário alargar o estudo a um maior número de prestadores. A compreensão das razões destes resultados implica o estudo dos indicadores socioeconómicos, epidemiológicos e geográficos das populações, bem como as características dos prestadores (Hospitais e CSP).
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics
Resumo:
Dissertation to obtain a Master degree in Biotechnology
Resumo:
Disseminated infection with Cryptococcus neoformans was observed in a newborn infant who presented fever and respiratory symptoms since the 52nd day of life. The mother was infected by human immunodeficiency virus and presented pulmonary and meningeal cryptococcal infection. This is a rare case of cryptococcal infection with probable maternal-fetal transmission.