993 resultados para Ultracold atomic gas
Resumo:
Atomic Force Microscope and related techniques have played a key role in the development of the nanotechnology revolution that is taking place in science. This paper reviews the basic principles behind the technique and its different operation modes and applications, pointing out research worksperformed in the Nanometric Techniques Unit of the CCiTUB in order to exemplify the vast array of capabilities of these instruments.
Resumo:
This is volume 1 of 5 and is the Iowa Plan for Atomic Energy Education. It is the orientation to the Iowa plan for atomic energy education. This plan was presented to teachers, students and the lay public of Iowa with the desire to remove fears and assist in pointing the way toward a sensitive consideration of what American citizens can and should know and do about atomic energy.
Resumo:
Up until now, analyses of the international distribution of pollutant emissions have not paid sufficient attention to the implications that, in terms of social welfare, the combined evolution of the global world average entails. In this context, this paper proposes the use of environmental welfare indices, taken and adapted from the literature on social welfare and inequality, in order to make a comprehensive examination of the international equity factor and the mean factor in this field. The proposed methodology is implemented empirically in order to explore the evolution in distributive-based environmental welfare on a global level for the three main pollutants with greenhouse gas effects: CO2, CH4 and NO, both globally and for selected years during the period of 1990- 2005. The main results found are as follows: firstly, typically, the environmental welfare associated with the overall greenhouse gases decreased significantly over the period, due primarily to the role of CO2; secondly, in contrast, the global welfare associated with CH4 and NO improved; and thirdly, typically, the evolutions can be attributed to a greater extent to the mean component than to the distributive component, although there are exceptions. These results would seem to be relevant in policy terms. JEL codes: D39; Q43; Q56. Keywords: environmental welfare: greenhouse gases; environmental equity.
Resumo:
A simple method determining airborne monoethanolamine has been developed. Monoethanolamine determination has traditionally been difficult due to analytical separation problems. Even in recent sophisticated methods, this difficulty remains as the major issue often resulting in time-consuming sample preparations. Impregnated glass fiber filters were used for sampling. Desorption of monoethanolamine was followed by capillary GC analysis and nitrogen phosphorous selective detection. Separation was achieved using a specific column for monoethanolamines (35% diphenyl and 65% dimethyl polysiloxane). The internal standard was quinoline. Derivatization steps were not needed. The calibration range was 0.5-80 μg/mL with a good correlation (R(2) = 0.996). Averaged overall precisions and accuracies were 4.8% and -7.8% for intraday (n = 30), and 10.5% and -5.9% for interday (n = 72). Mean recovery from spiked filters was 92.8% for the intraday variation, and 94.1% for the interday variation. Monoethanolamine on stored spiked filters was stable for at least 4 weeks at 5°C. This newly developed method was used among professional cleaners and air concentrations (n = 4) were 0.42 and 0.17 mg/m(3) for personal and 0.23 and 0.43 mg/m(3) for stationary measurements. The monoethanolamine air concentration method described here was simple, sensitive, and convenient both in terms of sampling and analytical analysis.
Resumo:
The main goal of this special issue was to gather contributions dealing with the latest breakthrough methods for providing value compounds and energy/fuel from waste valorization. Valorization is a relatively new approach in the area of industrial wastes management, a key issue to promote sustainable development. In this field, the recovery of value-added substances, such as antioxidants, proteins, vitamins, and so forth, from the processing of agroindustrial byproducts, is worth mentioning. Another important valorization approach is the use of biogas from waste treatment plants for the production of energy. Several approaches involving physical and chemical processes, thermal and biological processes that ensure reduced emissions and energy consumptions were taken into account. The papers selected for this topical issue represent some of the mostly researched methods that currently promote the valorization of wastes to energy and useful materials ...
Resumo:
The atomic force microscope is not only a very convenient tool for studying the topography of different samples, but it can also be used to measure specific binding forces between molecules. For this purpose, one type of molecule is attached to the tip and the other one to the substrate. Approaching the tip to the substrate allows the molecules to bind together. Retracting the tip breaks the newly formed bond. The rupture of a specific bond appears in the force-distance curves as a spike from which the binding force can be deduced. In this article we present an algorithm to automatically process force-distance curves in order to obtain bond strength histograms. The algorithm is based on a fuzzy logic approach that permits an evaluation of "quality" for every event and makes the detection procedure much faster compared to a manual selection. In this article, the software has been applied to measure the binding strength between tubuline and microtubuline associated proteins.
Resumo:
Due to important alteration caused by long time decomposition, the gases in human bodies buried for more than a year have not been investigated. For the first time, the results of gas analysis sampled from bodies recently exhumed after 30 years are presented. Adipocere formation has prevented the bodies from too important alteration, and gaseous areas were identified. The sampling was performed with airtight syringes assisted by multi-detector computed tomography (MDCT) in those specific areas. The important amount of methane (CH4), coupled to weak amounts of hydrogen (H2) and carbon dioxide (CO2), usual gaseous alteration indicators, have permitted to confirm methanogenesis mechanism for long period of alteration. H2 and CO2 produced during the first stages of the alteration process were consumed through anaerobic oxidation by methanogenic bacteria, generating CH4.
Resumo:
Ethyl glucuronide (EtG) is a minor and direct metabolite of ethanol. EtG is incorporated into the growing hair allowing retrospective investigation of chronic alcohol abuse. In this study, we report the development and the validation of a method using gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS) for the quantification of EtG in hair. EtG was extracted from about 30 mg of hair by aqueous incubation and purified by solid-phase extraction (SPE) using mixed mode extraction cartridges followed by derivation with perfluoropentanoic anhydride (PFPA). The analysis was performed in the selected reaction monitoring (SRM) mode using the transitions m/z 347-->163 (for the quantification) and m/z 347-->119 (for the identification) for EtG, and m/z 352-->163 for EtG-d(5) used as internal standard. For validation, we prepared quality controls (QC) using hair samples taken post mortem from 2 subjects with a known history of alcoholism. These samples were confirmed by a proficiency test with 7 participating laboratories. The assay linearity of EtG was confirmed over the range from 8.4 to 259.4 pg/mg hair, with a coefficient of determination (r(2)) above 0.999. The limit of detection (LOD) was estimated with 3.0 pg/mg. The lower limit of quantification (LLOQ) of the method was fixed at 8.4 pg/mg. Repeatability and intermediate precision (relative standard deviation, RSD%), tested at 4 QC levels, were less than 13.2%. The analytical method was applied to several hair samples obtained from autopsy cases with a history of alcoholism and/or lesions caused by alcohol. EtG concentrations in hair ranged from 60 to 820 pg/mg hair.
Resumo:
Propane can be responsible for several types of lethal intoxication and explosions. Quantifying it would be very helpful to determine in some cases the cause of death. Some gas chromatography-mass spectrometry (GC-MS) methods of propane measurements do already exist. The main drawback of these GC-MS methods described in the literature is the absence of a specific propane internal standard necessary for accurate quantitative analysis. The main outcome of the following study was to provide an innovative Headspace-GC-MS method (HS-GC-MS) applicable to the routine determination of propane concentration in forensic toxicology laboratories. To date, no stable isotope of propane is commercially available. The development of an in situ generation of standards is thus presented. An internal-labeled standard gas (C3DH7) is generated in situ by the stoichiometric formation of propane by the reaction of deuterated water (D2O) with Grignard reagent propylmagnesium chloride (C3H7MgCl). The method aims to use this internal standard to quantify propane concentrations and, therefore, to obtain precise measurements. Consequently, a complete validation with an accuracy profile according to two different guidelines, the French Society of Pharmaceutical Sciences and Techniques (SFSTP) and the Gesellschaft für toxikologische und Forensische Chemie (GTFCh), is presented.
Resumo:
Recent studies show that the composition of fingerprint residue varies significantly from the same donor as well as between donors. This variability is a major drawback in latent print dating issues. This study aimed, therefore, at the definition of a parameter that is less variable from print to print, using a ratio of peak area of a target compound degrading over time divided by the summed area of peaks of more stable compounds also found in latent print residues.Gas chromatography-mass spectrometry (GC/MS) analysis of the initial lipid composition of latent prints identifies four main classes of compounds that can be used in the definition of an aging parameter: fatty acids, sterols, sterol precursors, and wax esters (WEs). Although the entities composing the first three groups are quite well known, those composing WEs are poorly reported. Therefore, the first step of the present work was to identify WE compounds present in latent print residues deposited by different donors. Of 29 WEs recorded in the chromatograms, seven were observed in the majority of samples.The identified WE compounds were subsequently used in the definition of ratios in combination with squalene and cholesterol to reduce the variability of the initial composition between latent print residues from different persons and more particularly from the same person. Finally, the influence of a latent print enhancement process on the initial composition was studied by analyzing traces after treatment with magnetic powder, 1,2-indanedione, and cyanoacrylate.
Resumo:
The atomic force microscope is a convenient tool to probe living samples at the nanometric scale. Among its numerous capabilities, the instrument can be operated as a nano-indenter to gather information about the mechanical properties of the sample. In this operating mode, the deformation of the cantilever is displayed as a function of the indentation depth of the tip into the sample. Fitting this curve with different theoretical models permits us to estimate the Young's modulus of the sample at the indentation spot. We describe what to our knowledge is a new technique to process these curves to distinguish structures of different stiffness buried into the bulk of the sample. The working principle of this new imaging technique has been verified by finite element models and successfully applied to living cells.
Resumo:
Recent ink dating methods focused mainly on changes in solvent amounts occurring over time. A promising method was developed at the Landeskriminalamt of Munich using thermal desorption (TD) followed by gas chromatography / mass spectrometry (GC/MS) analysis. Sequential extractions of the phenoxyethanol present in ballpoint pen ink entries were carried out at two different temperatures. This method is applied in forensic practice and is currently implemented in several laboratories participating to the InCID group (International Collaboration on Ink Dating). However, harmonization of the method between the laboratories proved to be a particularly sensitive and time consuming task. The main aim of this work was therefore to implement the TD-GC/MS method at the Bundeskriminalamt (Wiesbaden, Germany) in order to evaluate if results were comparable to those obtained in Munich. At first validation criteria such as limits of reliable measurements, linearity and repeatability were determined. Samples were prepared in three different laboratories using the same inks and analyzed using two TDS-GC/MS instruments (one in Munich and one in Wiesbaden). The inter- and intra-laboratory variability of the ageing parameter was determined and ageing curves were compared. While inks stored in similar conditions yielded comparable ageing curves, it was observed that significantly different storage conditions had an influence on the resulting ageing curves. Finally, interpretation models, such as thresholds and trend tests, were evaluated and discussed in view of the obtained results. Trend tests were considered more suitable than threshold models. As both approaches showed limitations, an alternative model, based on the slopes of the ageing curves, was also proposed.
Resumo:
Over the last two decades, Atomic Force Microscopy (AFM) has emerged as the tool of choice to image living organisms in a near-physiological environment. Whereas fluorescence microscopy techniques allow labeling and tracking of components inside cells and the observation of dynamic processes, AFM is mainly a surface technique that can be operated on a wide range of substrates including biological samples. AFM enables extraction of topographical, mechanical and chemical information from these samples.