503 resultados para Saukkonen, Pasi


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS/HYPOTHESIS: To assess the use of paediatric continuous subcutaneous infusion (CSII) under real-life conditions by analysing data recorded for up to 90 days and relating them to outcome. METHODS: Pump programming data from patients aged 0-18 years treated with CSII in 30 centres from 16 European countries and Israel were recorded during routine clinical visits. HbA(1c) was measured centrally. RESULTS: A total of 1,041 patients (age: 11.8 +/- 4.2 years; diabetes duration: 6.0 +/- 3.6 years; average CSII duration: 2.0 +/- 1.3 years; HbA(1c): 8.0 +/- 1.3% [means +/- SD]) participated. Glycaemic control was better in preschool (n = 142; 7.5 +/- 0.9%) and pre-adolescent (6-11 years, n = 321; 7.7 +/- 1.0%) children than in adolescent patients (12-18 years, n = 578; 8.3 +/- 1.4%). There was a significant negative correlation between HbA(1c) and daily bolus number, but not between HbA(1c) and total daily insulin dose. The use of <6.7 daily boluses was a significant predictor of an HbA(1c) level >7.5%. The incidence of severe hypoglycaemia and ketoacidosis was 6.63 and 6.26 events per 100 patient-years, respectively. CONCLUSIONS/INTERPRETATION: This large paediatric survey of CSII shows that glycaemic targets can be frequently achieved, particularly in young children, and the incidence of acute complications is low. Adequate substitution of basal and prandial insulin is associated with a better HbA(1c).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM Depending on intensity, exercise may induce a strong hormonal and metabolic response, including acid-base imbalances and changes in microcirculation, potentially interfering with the accuracy of continuous glucose monitoring (CGM). The present study aimed at comparing the accuracy of the Dexcom G4 Platinum (DG4P) CGM during continuous moderate and intermittent high-intensity exercise (IHE) in adults with type 1 diabetes (T1DM). METHODS Ten male individuals with well-controlled T1DM (HbA1c 7.0±0.6% [54±6mmol/mol]) inserted the DG4P sensor 2 days prior to a 90min cycling session (50% VO2peak) either with (IHE) or without (CONT) a 10s all-out sprint every 10min. Venous blood samples for reference glucose measurement were drawn every 10min and euglycemia (target 7mmol/l) was maintained using an oral glucose solution. Additionally, lactate and venous blood gas variables were determined. RESULTS Mean reference blood glucose was 7.6±0.2mmol/l during IHE and 6.7±0.2mmol/l during CONT (p<0.001). IHE resulted in significantly higher levels of lactate (7.3±0.5mmol/l vs. 2.6±0.3mmol/l, p<0.001), while pH values were significantly lower in the IHE group (7.27 vs. 7.38, p=0.001). Mean absolute relative difference (MARD) was 13.3±2.2% for IHE and 13.6±2.8% for CONT suggesting comparable accuracy (p=0.90). Using Clarke Error Grid Analysis, 100% of CGM values during both IHE and CONT were in zones A and B (IHE: 77% and 23%; CONT: 78% and 22%). CONCLUSIONS The present study revealed good and comparable accuracy of the DG4P CGM system during intermittent high intensity and continuous moderate intensity exercise, despite marked differences in metabolic conditions. This corroborates the clinical robustness of CGM under differing exercise conditions. CLINICAL TRIAL REGISTRATION NUMBER ClinicalTrials.gov NCT02068638.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS/HYPOTHESIS To investigate exercise-related fuel metabolism in intermittent high-intensity (IHE) and continuous moderate intensity (CONT) exercise in individuals with type 1 diabetes mellitus. METHODS In a prospective randomised open-label cross-over trial twelve male individuals with well-controlled type 1 diabetes underwent a 90 min iso-energetic cycling session at 50% maximal oxygen consumption ([Formula: see text]), with (IHE) or without (CONT) interspersed 10 s sprints every 10 min without insulin adaptation. Euglycaemia was maintained using oral (13)C-labelled glucose. (13)C Magnetic resonance spectroscopy (MRS) served to quantify hepatocellular and intramyocellular glycogen. Measurements of glucose kinetics (stable isotopes), hormones and metabolites complemented the investigation. RESULTS Glucose and insulin levels were comparable between interventions. Exogenous glucose requirements during the last 30 min of exercise were significantly lower in IHE (p = 0.02). Hepatic glucose output did not differ significantly between interventions, but glucose disposal was significantly lower in IHE (p < 0.05). There was no significant difference in glycogen consumption. Growth hormone, catecholamine and lactate levels were significantly higher in IHE (p < 0.05). CONCLUSIONS/INTERPRETATION IHE in individuals with type 1 diabetes without insulin adaptation reduced exogenous glucose requirements compared with CONT. The difference was not related to increased hepatic glucose output, nor to enhanced muscle glycogen utilisation, but to decreased glucose uptake. The lower glucose disposal in IHE implies a shift towards consumption of alternative substrates. These findings indicate a high flexibility of exercise-related fuel metabolism in type 1 diabetes, and point towards a novel and potentially beneficial role of IHE in these individuals. TRIAL REGISTRATION ClinicalTrials.gov NCT02068638 FUNDING: Swiss National Science Foundation (grant number 320030_149321/) and R&A Scherbarth Foundation (Switzerland).

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The potential shown by Lean in different domains has aroused interest in the software industry. However, it remains unclear how Lean can be effectively applied in a domain such as software development that is fundamentally different from manufacturing. This study explores how Lean principles are implemented in software development companies and the challenges that arise when applying Lean Software Development. For that, a case study was conducted at Ericsson R&D Finland, which successfully adopted Scrum in 2009 and subsequently started a comprehensible transition to Lean in 2010. Focus groups were conducted with company representatives to help devise a questionnaire supporting the creation of a Lean mindset in the company (Team Amplifier). Afterwards, the questionnaire was used in 16 teams based in Finland, Hungary and China to evaluate the status of the transformation. By using Lean thinking, Ericsson R&D Finland has made important improvements to the quality of its products, customer satisfaction and transparency within the organization. Moreover, build times have been reduced over ten times and the number of commits per day has increased roughly five times.The study makes two main contributions to research. First, the main factors that have enabled Ericsson R&D?s achievements are analysed. Elements such as ?network of product owners?, ?continuous integration?, ?work in progress limits? and ?communities of practice? have been identified as being of fundamental importance. Second, three categories of challenges in using Lean Software Development were identified: ?achieving flow?, ?transparency? and ?creating a learning culture?

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Acknowledgements This paper belongs to the studies carried out by Kuopio Birth Cohort consortium (www.KuBiCo.fi). We thank Ms Pirjo Hänninen for expert laboratory assistance at University of Eastern Finland, Ms Margaret Fraser, Dr Panagiotis Filis and the Proteomics Core Facility at the University of Aberdeen for their expert assistance. We also thank the staff of the Department of Obstetrics and Gynaecology in Kuopio University Hospital for skilful collection of these specimens. This work was supported by the Academy of Finland [122859/2007], the Helena Vuorenmies Foundation, the Emil Aaltonen Foundation, the University of Eastern Finland Doctoral Programme in Drug Research and the Medical Research Council, UK [MR/L010011/1]. The funders played no roles in study design, data collection, data analysis, manuscript preparation and/or publication decisions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ANX7 gene is located on human chromosome 10q21, a site long hypothesized to harbor a tumor suppressor gene(s) (TSG) associated with prostate and other cancers. To test whether ANX7 might be a candidate TSG, we examined the ANX7-dependent suppression of human tumor cell growth, stage-specific ANX7 expression in 301 prostate specimens on a prostate tissue microarray, and loss of heterozygosity (LOH) of microsatellite markers at or near the ANX7 locus. Here we report that human tumor cell proliferation and colony formation are markedly reduced when the wild-type ANX7 gene is transfected into two prostate tumor cell lines, LNCaP and DU145. Consistently, analysis of ANX7 protein expression in human prostate tumor microarrays reveals a significantly higher rate of loss of ANX7 expression in metastatic and local recurrences of hormone refractory prostate cancer as compared with primary tumors (P = 0.0001). Using four microsatellite markers at or near the ANX7 locus, and laser capture microdissected tumor cells, 35% of the 20 primary prostate tumors show LOH. The microsatellite marker closest to the ANX7 locus showed the highest rate of LOH, including one homozygous deletion. We conclude that the ANX7 gene exhibits many biological and genetic properties expected of a TSG and may play a role in prostate cancer progression.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ill. in 1st pt. largely engravings, with some woodcuts; in pt. 2, only woodcuts. Engraved frontispiece, 1st p. It is signed: Alberi' Pasi.' F. Veronae.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

"Prilozhenïe k zhurnalu 'Niva' na 1901 g."

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dendrimers are nonviral vectors that have attracted interest on account of a number of features. They are structurally versatile because their size, shape, and surface charge can be selectively altered. Here we examine the functions of a new family of composite dendrimers that were synthesized with lipidic amino acid cores. These dendrimers are bifunctional because they are characterized by positively charged (lysine) modules for interaction with nucleic acids and neutral lipidic moieties for membrane lipid-bilayer transit. We assessed their structure-function correlations by a combination of molecular and biophysical techniques. Our assessment revealed an unexpected pleitropy of functions subserved by these vectors that included plasmid and oligonucleotide delivery. We also generated a firefly luciferase cell line in which we could modulate luciferase activity by RNA interference. We found that these vectors could also mediate RNA suppression of luciferase expression by delivering double-stranded luciferase transcripts generated in vitro. The structural uniqueness of these lipidic peptide dendrimers coupled with their ease and specificity of assembly and the versatility in their choice of cargo, puts them in a new category of macromolecule carriers. These vectors, therefore, have potential applications as epigenetic modifiers of gene function. (C) 2004 Wiley-Liss, Inc. and the American Pharmacists Association.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Leflunomide has shown promise in the treatment of psoriasis. Objective: To provide an in-depth analysis of the effect of leflunomide on psoriasis in patients with psoriatic arthritis (PsA). Methods: 190 patients with plaque psoriasis (at least 3% skin involvement) and active PsA were randomized to double-blind treatment with leflunomide (100 mg/day loading dose for 3 days followed by 20 mg/day orally) or placebo for 24 weeks. Results: As previously reported, leflunomide resulted in a significantly higher Psoriatic Arthritis Response Criteria response rate than placebo (58.9 vs. 29.7%; p < 0.0001). Significant differences in favor of leflunomide were also observed in the Psoriasis Area and Severity Index (PASI 50 in 30.4% of patients vs. 18.9% for placebo; p = 0.05), target lesion response (46.4 vs. 25.3%; p = 0.0048), combined skin and joint response (27.2 vs. 8.9%; p < 0.0001), Dermatology Life Quality Index (improvement of 1.9 points vs. 0.2; p = 0.0173) and certain SF-36 subdomains. Dermatological responses were observed at the earliest examination (4 weeks) and increased throughout the 24-week study. Conclusion: Once-daily oral leflunomide is an effective and convenient treatment for PsA and plaque psoriasis. Copyright (c) 2006 S. Karger AG, Basel.