991 resultados para Optical characteristics
Resumo:
Measures of vocal intensity, frequency and harshness were compared for 19 hearing-impaired and 21 normal-hearing people over 60 years of age. Significantly greater comfortable intensity levels were found in the hearing-impaired group, but the other measures of frequency and harshness were not significantly different. A large proportion of the subjects in both groups reported a history of gastro-oesophageal reflux (GER), a condition associated with vocal fold pathology and hoarseness. Comparison of the GER and non-GER subjects on the measures of vocal function showed that the female GER speaker exhibited lower frequency on the vowel /u/ than the non-GER subjects. Clinicians need to be aware of the effect of highly prevalent disorders such as hearing impairment and GER on the voices of elderly speakers.
Resumo:
Computer modelling has shown that electrical characteristics of individual pixels may be extracted from within multiple-frequency electrical impedance tomography (MFEIT) images formed using a reference data set obtained from a purely resistive, homogeneous medium. In some applications it is desirable to extract the electrical characteristics of individual pixels from images where a purely resistive, homogeneous reference data set is not available. One such application of the technique of MFEIT is to allow the acquisition of in vivo images using reference data sets obtained from a non-homogeneous medium with a reactive component. However, the reactive component of the reference data set introduces difficulties with the extraction of the true electrical characteristics from the image pixels. This study was a preliminary investigation of a technique to extract electrical parameters from multifrequency images when the reference data set has a reactive component. Unlike the situation in which a homogenous, resistive data set is available, it is not possible to obtain the impedance and phase information directly from the image pixel values of the MFEIT images data set, as the phase of the reactive reference is not known. The method reported here to extract the electrical characteristics (the Cole-Cole plot) initially assumes that this phase angle is zero. With this assumption, an impedance spectrum can be directly extracted from the image set. To obtain the true Cole-Cole plot a correction must be applied to account for the inherent rotation of the extracted impedance spectrum about the origin, which is a result of the assumption. This work shows that the angle of rotation associated with the reactive component of the reference data set may be determined using a priori knowledge of the distribution of frequencies of the Cole-Cole plot. Using this angle of rotation, the true Cole-Cole plot can be obtained from the impedance spectrum extracted from the MFEIT image data set. The method was investigated using simulated data, both with and without noise, and also for image data obtained in vitro. The in vitro studies involved 32 logarithmically spaced frequencies from 4 kHz up to 1 MHz and demonstrated that differences between the true characteristics and those of the impedance spectrum were reduced significantly after application of the correction technique. The differences between the extracted parameters and the true values prior to correction were in the range from 16% to 70%. Following application of the correction technique the differences were reduced to less than 5%. The parameters obtained from the Cole-Cole plot may be useful as a characterization of the nature and health of the imaged tissues.
Resumo:
BACKGROUND Marshall bundles (MBs) are the muscle bundles within the ligament of Marshall. OBJECTIVE This trial sought to the electrophysiological characteristics of the MB and the anatomical connections between MB and left atrium (LA) in patients with persistent atrial fibrillation (AF). METHODS We enrolled 72 patients (male: female 59: 13, age 59.9 +/- 9.4 years) who underwent MB mapping and ablation for AF. MB mapping was done via an endocardial or epicardial approach during sinus rhythm and AF. RESULTS Recordings were successful in 64 of 72 patients (89%). A single connection was noted in 11 of 64 patients between the MB and the coronary sinus (CS) muscle sleeves. The MB recordings showed distinct MB potentials with a proximal-to-distal activation pattern during sinus rhythm. During AF, organized passive activations and dissociated slow MB ectopic activities were commonly observed in this type of connection. Double connections to both CS and LA around left pulmonary veins were noted in 23 of 64 patients (36%). After the ablation of the distal connection, MB recording showed typical double potentials as in single connection. Multiple connections were noted in 30 of 64 patients (47%). During sinus rhythm, the earliest activation was in the middle of the MB. The activation patterns were irregular and variable in each patient. During AF, rapid and fractionated complex activations were noted in all patients of this group. CONCLUSION We documented 3 different types of MB-LA connections. Rapid and fractionated activations were most commonly observed in the MB that had multiple LA connections.
Resumo:
Quantum information theory, applied to optical interferometry, yields a 1/n scaling of phase uncertainty Delta phi independent of the applied phase shift phi, where n is the number of photons in the interferometer. This 1/n scaling is achieved provided that the output state is subjected to an optimal phase measurement. We establish this scaling law for both passive (linear) and active (nonlinear) interferometers and identify the coefficient of proportionality. Whereas a highly nonclassical state is required to achieve optimal scaling for passive interferometry, a classical input state yields a 1/n scaling of phase uncertainty for active interferometry.
Resumo:
OBJECTIVE. The objective of our study was to describe the T1 and T2 signal intensity characteristics of papillary renal cell carcinoma (RCC) and clear cell RCC with pathologic correlation. MATERIALS AND METHODS. Of 539 RCCs, 49 tumors (21 papillary RCCs and 28 clear cell RCCs) in 45 patients were examined with MRI. Two radiologists retrospectively and independently assessed each tumor`s T1 and T2 signal intensity qualitatively and quantitatively (i.e., the signal intensity [SI] ratio [tumor SI/renal cortex SI]). Of the 49 tumors, 37 (76%) were assessed for pathology features including tumor architecture and the presence of hemosiderin, ferritin, necrosis, and fibrosis. MRI findings and pathology features were correlated. Statistical methods included summary statistics and Wilcoxon`s rank sum test for signal intensity, contingency tables for assessing reader agreement, concordance rate between the two readers with 95% CIs, and Fisher`s exact test for independence, all stratified by RCC type. RESULTS. Papillary RCCs and clear cell RCCs had a similar appearance and signal intensity ratio on T1-weighted images. On T2-weighted images, most papillary RCCs were hypointense (reader 1, 13/21; reader 2, 14/21), with an average mean signal intensity ratio for both readers of 0.67 +/- 0.2, and none was hyperintense, whereas most clear cell RCCs were hyperintense (reader 1, 21/28; reader 2, 17/28), with an average mean signal intensity ratio for both readers of 1.41 +/- 0.4 (p < 0.05). A tumor T2 signal intensity ratio of <= 0.66 had a specificity of 100% and sensitivity of 54% for papillary RCC. Most T2 hypointense tumors exhibited predominant papillary architecture; most T2 hyperintense tumors had a predominant nested architecture (p < 0.05). CONCLUSION. On T2-weighted images, most papillary RCCs are hypointense and clear cell RCCs, hyperintense. The T2 hypointense appearance of papillary RCCs correlated with a predominant papillary architecture at pathology.
Resumo:
An ''optical meson'' (two-photon quantum soliton) is proven to exist in a parametric waveguide. This could provide an ideal quantum soliton environment, because of more realistic formation lengths and much larger binding energies than chi((3)) quantum solitons. We estimate the binding energy, radius, and interaction length in comparison to the chi((3)) case in optical fibers.
Resumo:
We propose a simulated-annealing-based genetic algorithm for solving model parameter estimation problems. The algorithm incorporates advantages of both genetic algorithms and simulated annealing. Tests on computer-generated synthetic data that closely resemble optical constants of a metal were performed to compare the efficiency of plain genetic algorithms against the simulated-annealing-based genetic algorithms. These tests assess the ability of the algorithms to and the global minimum and the accuracy of values obtained for model parameters. Finally, the algorithm with the best performance is used to fit the model dielectric function to data for platinum and aluminum. (C) 1997 Optical Society of America.
Resumo:
We consider solutions to the second-harmonic generation equations in two-and three-dimensional dispersive media in the form of solitons localized in space and time. As is known, collapse does not take place in these models, which is why the solitons may be stable. The general solution is obtained in an approximate analytical form by means of a variational approach, which also allows the stability of the solutions to be predicted. Then, we directly simulate the two-dimensional case, taking the initial configuration as suggested by the variational approximation. We thus demonstrate that spatiotemporal solitons indeed exist and are stable. Furthermore, they are not, in the general case, equivalent to the previously known cylindrical spatial solitons. Direct simulations generate solitons with some internal oscillations. However, these oscillations neither grow nor do they exhibit any significant radiative damping. Numerical solutions of the stationary version of the equations produce the same solitons in their unperturbed form, i.e., without internal oscillations. Strictly stable solitons exist only if the system has anomalous dispersion at both the fundamental harmonic and second harmonic (SH), including the case of zero dispersion at SH. Quasistationary solitons, decaying extremely slowly into radiation, are found in the presence of weak normal dispersion at the second-harmonic frequency.
Resumo:
We analyze the properties of light beams carrying phase singularities, or optical vortices. The transformations of topological charge during free-space propagation of a light wave, which is a combination of a Gaussian beam and a multiple charged optical vortex within a Gaussian envelope, are studied both in theory and experiment. We revise the existing knowledge about topological charge conservation, and demonstrate possible scenarios where additional vortices appear or annihilate during free propagation of such a combined beam. Coaxial interference of optical vortices is also analyzed, and the general rule for angular-momentum density distribution in a combined beam is established. We show that, in spite of any variation in the number of vortices in a combined beam, the total angular momentum is constant during the propagation. [S1050-2947(97)09910-1].
Resumo:
Three patients with progressive visual loss, chronic alcoholism and tabagism were submitted to a complete neuro-ophthalmic examination and to retinal nerve fiber layer (RNFL) measurements using optical coherence tomography (OCT) scanning. Two patients showed marked RNFL loss in the temporal sector of the optic disc. However, a third patient presented RNFL measurements within or above normal limits, based on the Stratus-OCT normative database. Such findings may be due to possible RNFL edema similar to the one that may occur in the acute phase of toxic optic neuropathies. Stratus-OCT was able to detect RNFL loss in the papillomacular bundle of patients with tobacco-alcohol-induced toxic optic neuropathy. However, interpretation must be careful when OCT does not show abnormality in order to prevent diagnostic confusion, since overestimation of RNFL thickness measurements is possible in such cases.
Resumo:
PURPOSE: To compare the ability of Fourier-domain (FD) optical coherence tomography (3D OCT-1000; Top, con, Tokyo, Japan) and time domain (TD) OCT (Stratus; Carl Zeiss Meditec Inc, Dublin, California, USA) to detect axonal loss in eyes with band atrophy (BA) of the optic nerve. DESIGN: Cross-sectional study. METHODS: Thirty-six eyes from 36 patients with BA and temporal visual field (VF) defect from chiasmal compression and 36 normal eyes were studied. Subjects were submitted to standard automated perimetry and macular and retinal nerve fiber layer (RNFL) measurements were taken using 3D OCT-1000 and Stratus OCT. Receiver operating characteristic (ROC) curves were calculated for each parameter. Spearman correlation coefficients were obtained to evaluate the relationship between RNFL and macular thickness parameters and severity of VF loss. Measurements from the two devices were compared. RESULTS: Regardless of OCT device, all RNFL and macular thickness parameters were significantly lower in eyes with BA compared with normal eyes, but no statistically significant difference was found with regard to the area under the ROC curve. Structure-function relationships were also similar for the two devices. In both groups, RNFL and macular thickness measurements were generally and in some cases significantly smaller with 3D OCT-1000 than with Stratus OCT. CONCLUSIONS: The introduction of FD technology did not lead to better discrimination ability for detecting BA of the optic nerve compared with TD technology when using the software currently provided by the manufacturer. 3D OCT-1000 FD OCT RNFL and macular measurements were generally smaller than TD Stratus OCT measurements. Investigators should be aware of this fact when comparing measurements obtained with these two devices. (Am J Oplathalmol 2009;147: 56-63. (c) 2009 by Elsevier Inc. All rights reserved.)
Resumo:
Aim To compare the ability of scanning laser polarimeter (SLP) with variable corneal compensation (GDx VCC) and optical coherence tomograph (Stratus OCT) to discriminate between eyes with band atrophy (BA) of the optic nerve and healthy eyes. Methods The study included 37 eyes with BA and temporal visual field (VF) defects from chiasmal compression, and 29 normal eyes. Subjects underwent standard automated perimetry (SAP) and retinal nerve fibre layer (RNFL) scans using GDx VCC and Stratus OCT. The severity of the VF defects was evaluated by the temporal mean defect (TMD), calculated as the average of 22 values of the temporal total deviation plot on SAP. Receiver operating characteristic (ROC) curves were calculated. Pearson`s correlation coefficients were used to evaluate the relationship between RNFL thickness parameters and the TMD. Results No significant difference was found between the ROC curves areas (AUCs) for the GDx VCC and Stratus OCT with regard to average RNFL thickness (0.98 and 0.99, respectively) and the superior (0.94; 0.95), inferior (0.96; 0.97), and nasal (0.92; 0.96) quadrants. However, the AUC in the temporal quadrant (0.77) was significantly smaller (P < 0.001) with GDx VCC than with Stratus OCT (0.98). Lower TMD values were associated with smaller RNFL thickness in most parameters from both equipments. Conclusion Adding VCC resulted in improved performance in SLP when evaluating eyes with BA, and both technologies are sensitive in detecting average, superior, inferior, and nasal quadrant RNFL loss. However, GDx VCC still poorly discriminates RNFL loss in the temporal quadrant when compared with Stratus OCT.
Resumo:
Background: The Rivermead Behavioural Memory Test (RBMT) assesses everyday memory by means of tasks which mimic daily challenges. The objective was to examine the validity of the Brazilian version of the RBMT to detect cognitive decline. Methods: 195 older adults were diagnosed as normal controls (NC) or with mild cognitive impairment (MCI) or Alzheimer`s disease (AD) by a multidisciplinary team, after participants completed clinical and neuropsychological protocols. Results: Cronbach`s alpha was high for the total sample for the RBMT profile (PS) and screening scores (SS) (PS=0.91, SS=0.87) and for the AD group (PS=0.84, SS=0.85), and moderate for the MCI (PS=0.62, SS=0.55)and NC (PS=0.62, SS=0.60) groups. RBMT total scores, Appointment, Pictures, Immediate and Delayed Story, Immediate and Delayed Route, Delayed Message and Date contributed to differentiate NC from MCI. ROC curve analyses indicated high accuracy to differentiate NC from AD patients, and, moderate accuracy to differentiate NC from MCI. Conclusions: The Brazilian version of the RBMT seems to be an appropriate instrument to identify memory decline in Brazilian older adults.
Resumo:
Little is known about the effect of clinical characteristics, parental psychopathology, family functioning, and environmental stressors in the response to methylphenidate in children with attention-deficit/hyperactivity disorder (ADHD) followed up in a naturalistic setting. Data from cultures outside the United States are extremely scarce. This is a longitudinal study using a nonrandom assignment, quasi-experimental design. One hundred twenty-five children with ADHD were treated with methylphenidate according to standard clinical procedures, and followed up for 6 months. The severity of ADHD symptoms was assessed by the Swanson, Nolan, and Pelham rating scale. In the final multivariate model, ADHD combined subtype (P < 0.001) and comorbidity with oppositional defiant disorder (P = 0.03) were both predictors of a worse clinical response. In addition, the levels of maternal ADHD symptoms were also associated with worse prognosis (P < 0.001). In the context of several adverse psychosocial factors assessed, only undesired pregnancy was associated with poorer response to methylphenidate in the final comprehensive-model (P = 0.02). Our study provides evidence for the involvement of clinical characteristics, maternal psychopathology, and environmental stressors in the response to methylphenidate. Clinicians may consider adjuvant strategies when negative predictors are present to increase the chances of success with methylphenidate treatment.