970 resultados para Fixed implant prosthesis
Resumo:
A partial review is proposed on the existing literature for the research performed in orthopedic implant used as drug delivery system. In the first part, an evaluation is given on the clinical need to deliver a drug in the surrounding of an implant. Secondly, a review of the clinical situation is developed for implants already used as drug delivery system. Experimental works performed for local delivery are reported. In particular, a description is given on the in vitro and in vivo studies where the implant is coated with different proteins or drugs. Finally, a conclusion is proposed on the next step in the development of orthopedic implant as drug delivery system mentioning also the industrial situation.
Resumo:
A stochastic nonlinear partial differential equation is constructed for two different models exhibiting self-organized criticality: the Bak-Tang-Wiesenfeld (BTW) sandpile model [Phys. Rev. Lett. 59, 381 (1987); Phys. Rev. A 38, 364 (1988)] and the Zhang model [Phys. Rev. Lett. 63, 470 (1989)]. The dynamic renormalization group (DRG) enables one to compute the critical exponents. However, the nontrivial stable fixed point of the DRG transformation is unreachable for the original parameters of the models. We introduce an alternative regularization of the step function involved in the threshold condition, which breaks the symmetry of the BTW model. Although the symmetry properties of the two models are different, it is shown that they both belong to the same universality class. In this case the DRG procedure leads to a symmetric behavior for both models, restoring the broken symmetry, and makes accessible the nontrivial fixed point. This technique could also be applied to other problems with threshold dynamics.
Resumo:
We report the first case of Corynebacterium bovis shoulder prosthetic joint infection. The organism was isolated from intraoperative tissue culture and from the removed prosthesis using sonication. A 2-stage exchange and 3 months of antibiotic therapy were performed. C. bovis may cause implant-associated infections, which can manifest as low-grade infection.
Resumo:
BACKGROUND: Clinical results of total ankle arthroplasty with early designs were disappointing. Recently-developed ankle prostheses have good mid-term results; however, limited information is available regarding effects of total ankle arthroplasty on ankle laxity. METHODS: Eight cadaveric lower extremities were tested with a custom device which enabled measurement of multi-axial forces, moments, and displacement during applied axial, shear, and rotational loading. Tests consisted of anterior-posterior and medial-lateral translation and internal-external rotation of the talus relative to the tibia during axial loads on the tibia simulating body weight (700 N) and an unloaded condition (5 N). Tests were performed in neutral, dorsiflexion, and plantarflexion. Laxity was determined for the intact ankle, and following insertion of an unconstrained total ankle implant, comparing load-displacement curve. FINDINGS: Laxity after total ankle arthroplasty did not approximate the normal ankle in most conditions tested. Displacement was significantly greater for total ankle arthroplasty in both posterior and lateral translation, and internal rotation, with 5 N axial loading, and anterior-posterior, medial-lateral translation, and internal-external rotation for 700 N axial loading. For the 700 N axial load condition, in the neutral ankle position, total anterior-posterior translation averaged 0.4 mm (SD 0.2 mm), but 6.0 mm (SD 1.5 mm) after total ankle arthroplasty (P<0.01). This study demonstrated more laxity in the replaced ankle than normal ankle for both unloaded and 700 N axially loaded conditions. INTERPRETATION: These data indicate the increased responsibility of the ligaments for ankle laxity after total ankle arthroplasty and suggest the importance of meticulous ligament reconstruction with total ankle arthroplasty operations.
Resumo:
BACKGROUND: Artemisinin-based combination therapy (ACT) has been promoted as a means to reduce malaria transmission due to their ability to kill both asexual blood stages of malaria parasites, which sustain infections over long periods and the immature derived sexual stages responsible for infecting mosquitoes and onward transmission. Early studies reported a temporal association between ACT introduction and reduced malaria transmission in a number of ecological settings. However, these reports have come from areas with low to moderate malaria transmission, been confounded by the presence of other interventions or environmental changes that may have reduced malaria transmission, and have not included a comparison group without ACT. This report presents results from the first large-scale observational study to assess the impact of case management with ACT on population-level measures of malaria endemicity in an area with intense transmission where the benefits of effective infection clearance might be compromised by frequent and repeated re-infection. METHODS: A pre-post observational study with a non-randomized comparison group was conducted at two sites in Tanzania. Both sites used sulphadoxine-pyrimethamine (SP) monotherapy as a first-line anti-malarial from mid-2001 through 2002. In 2003, the ACT, artesunate (AS) co-administered with SP (AS + SP), was introduced in all fixed health facilities in the intervention site, including both public and registered non-governmental facilities. Population-level prevalence of Plasmodium falciparum asexual parasitaemia and gametocytaemia were assessed using light microscopy from samples collected during representative household surveys in 2001, 2002, 2004, 2005 and 2006. FINDINGS: Among 37,309 observations included in the analysis, annual asexual parasitaemia prevalence in persons of all ages ranged from 11% to 28% and gametocytaemia prevalence ranged from <1% to 2% between the two sites and across the five survey years. A multivariable logistic regression model was fitted to adjust for age, socioeconomic status, bed net use and rainfall. In the presence of consistently high coverage and efficacy of SP monotherapy and AS + SP in the comparison and intervention areas, the introduction of ACT in the intervention site was associated with a modest reduction in the adjusted asexual parasitaemia prevalence of 5 percentage-points or 23% (p < 0.0001) relative to the comparison site. Gametocytaemia prevalence did not differ significantly (p = 0.30). INTERPRETATION: The introduction of ACT at fixed health facilities only modestly reduced asexual parasitaemia prevalence. ACT is effective for treatment of uncomplicated malaria and should have substantial public health impact on morbidity and mortality, but is unlikely to reduce malaria transmission substantially in much of sub-Saharan Africa where individuals are rapidly re-infected.
Resumo:
Recent guidelines recommend initiation of antihypertensive therapy with fixed-dose combinations in high-risk patients because such patients usually need two or more blood pressure (BP)-lowering agents in order to normalize their BP. Agents that block the renin-angiotensin system (ACE inhibitors or angiotensin II receptor antagonists [angiotensin receptor blockers; ARBs]) are preferred for the management of hypertension in most patients exhibiting subclinical target organ damage, or established cardiovascular or renal diseases. Unless contraindicated they should be one of the components of fixed-dose combinations, whereas the other component may be either a calcium channel antagonist or a thiazide diuretic. Fixed-dose combinations containing an ACE inhibitor or ARB plus a calcium channel antagonist appear particularly effective in preventing complications of coronary heart disease.
Resumo:
Epistatic effects involving genic combinations of fixed and non fixed genes are shown to contribute to the genotypic mean of any population. These effects define specific additive x additive and additive x dominant epistatic components. As such components are not estimable, their relative importance cannot be assessed. These epistatic effects can cause bias in the estimates of the additive and dominance components to which they are confounded. The magnitude of the bias depends on the relative values of the epistatic effects, comparatively to deviations d and h, type of prevailing epistasis and direction of dominance.
Resumo:
The aim of this study was to prospectively evaluate the accuracy and predictability of new three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction.We analyzed the preoperative and postoperative clinical and radiologic data of 10 patients with isolated blow-out orbital fractures. Fracture locations were as follows: floor (N = 7; 70%), medial wall (N = 1; 1%), and floor/medial wall (N = 2; 2%). The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures. A three-dimensional preformed AO titanium mesh plate (0.4 mm in thickness) was selected according to the size of the defect previously measured on the preoperative computed tomographic (CT) scan examination and fixed at the inferior orbital rim with 1 or 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative CT scan. Coronal CT scan slices were used to measure bony orbital volume using OsiriX Medical Image software. Reconstructed versus uninjured orbital volume were statistically correlated.Nine patients (90%) had a successful treatment outcome without complications. One patient (10%) developed a mechanical limitation of upward gaze with a resulting handicapping diplopia requiring hardware removal. Postoperative orbital CT scan showed an anatomic three-dimensional placement of the orbital mesh plates in all of the patients. Volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 2.5 cm(3). There was no significant difference in volume between the reconstructed and uninjured orbits.This preliminary study has demonstrated that three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction results in (1) a high rate of success with an acceptable rate of major clinical complications (10%) and (2) an anatomic restoration of the bony orbital contour and volume that closely approximates that of the contralateral uninjured orbit.
Resumo:
Purpose: To compare the efficacy and safety of a slowly resorbable glaucoma implant, Healaflow (HF) and Healon 5 (H5) as spacers injected into failing filtration blebs at the time of bleb needlings, augmented with MMC Methods: Eighty-four glaucoma patients with filtration bleb failure following glaucoma surgery (deep sclerectomy/ trabeculectomy) underwent bleb needling using either HF (n=44) or H5 (n=40) as an intrableb viscoelastic spacer. All needlings were augmented by MMC and performed in the operating room, by a single surgeon. The choice between HF and H5 was randomised. Postoperative data for IOP, number of glaucoma medications (GMs), antimetabolite injections (AMIs), bleb morphology and all complications were recorded at day 1 (D1), weeks 1 (W1), 4 (W4), month 6 (M6) and last visit. Success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline Results: Age was comparable between groups (HF vs H5; 66 vs 72 years; p=0.13*). There were no differences in mean postoperative IOP or GMs at any time point between groups (mean IOP = HF vs H5; prior to needling=19.8mmHg vs 18.7mmHg, p=0.48*; D1=10.4mmHg vs 10.2mmHg, p=0.85*; W1=12.3mmHg vs 13.8mmHg, p=0.33*; W4=15.7mmHg vs 15.1mmHg, p=0.69*; M6=14.3mmHg vs 13.8mmHg, p=0.69*. Mean GMs= HF vs H5; prior to needling=1.7 vs 1.7, p=0.96*; M6=0.9 vs 1.1, p=0.66*). Success rates were comparable between HF and H5 groups (74% vs 71%). Requirements for AMIs were similar between groups; post filtration surgery and prior to needling (mean AMIs 1.54 vs 1.65 p=0.82*) and within the first six months following needling ( 0.77 vs 0.65 p=0.70*). Complication rates were infrequent in both groups (9%, HF; 3%, H5) * two-sample t-test Conclusions: The early to mid-term success rates of needlings using intrableb spacers were high. However there were no differences observed between the use of crosslinked and high molecular weight sodium hyaluronate
Resumo:
Rapport de synthèse : Le glaucome à angle ouvert est une neuropathie optique chronique progressive pour laquelle de nombreux traitements tant médicaux que chirurgicaux ont été proposés. La prise en charge chirurgicale s'articule principalement autour de deux chirurgies filtrantes, la trabéculectomie et la sclérectomie profonde avec implant de collagène. Cependant, les complications postopératoires de ces deux interventions étant relativement fréquentes, la recherche s'est orientée vers des traitements alternatifs dont la mise en place de micro-drains. Ces implants de drainage diminuent la pression intraoculaire en créant un court-circuit du flux d'humeur aqueuse de la chambre antérieure vers l'espace sous-conjonctival avec formation d'une bulle de filtration. L'implant Ex-PRESS R-50 est un implant miniature (2.5 mm de long pour 400 µm de diamètre) en acier inoxydable et biocompatible. La présente étude s'est proposée d'étudier l'efficacité et la sécurité de l'implant miniature Ex-Press R-50 lors d'une opération combinée cataracte-glaucome. Trente-cinq yeux de 35 patients (âge moyen: 75 ans) ont été inclus dans l'étude. Tous les patients ont bénéficié d'une opération de la cataracte par phacoemulsification et mise en place d'un implant de chambre postérieure suivie de l'implantation du micro-drain. Les pressions intraoculaires préopératoires et postopératoires, la meilleure acuité visuelle corrigée, le nombre de médicaments anti-glaucomateux ainsi que le type et le nombre de complications ont été évalués mensuellement puis tous les 6 mois pendant 4 ans. Le succès total a été défini par une pression postopératoire finale inférieure à 18mmHg sans traitement médical associé, le succès partiel par une pression postopératoire finale inférieure à 18mmHg avec ou sans traitement médical associé.. Le suivi moyen a été de 36.9 mois avec une baisse de la pression intraoculaire significative d'environ 25%. Une augmentation de l'acuité visuelle a été observée après l'opération de la cataracte et le nombre de médicaments anti-glaucomateux a été réduit de 57%. Dix patients ont bénéficié d'un traitement supplémentaire de la bulle de filtration par injection d'anti-métabolite (mitomycine C). Nous avons observé 8 complications majeures (4 érosions conjonctivales et 4 obstructions de l'orifice interne du micro-drain), toutes suivies de l'ablation de l'implant et de la réalisation d'une chirurgie classique du glaucome. En se basant sur les courbes de Kaplan-Meier à 48 mois, le taux de succès total était de 32.7% et le succès partiel de 53.7%. Nous pouvons conclure suite à ce travail que l'implant miniature Ex-PRESS R-50 est associé à un nombre trop élevé de complications, même si les cas non compliqués ont bénéficié d'une baisse significative de la pression intraoculaire. La modification de l'architecture du micro-drain ainsi que de la technique chirurgicale devrait augmenter le taux de succès.
Resumo:
Purpose: Polyethylene wear is a recurrent problem in joint arthroplasty. Small debris particles are also associated to inflammation reaction of the surrounding bone, eventually leading to the failure of the bound between the implant and the host bone, and implant loosening. The goal of this study was thus to estimate the volume of polyethylene wear of a reversed prosthesis, and compare it to an anatomic prosthesis, during one year of activities of daily living. Material and Methods: A numerical musculoskeletal model of the glenohumeral joint was used for this comparative study. The reversed (RP) and anatomic (AP) Aequalis prostheses were positioned in the numerical model. Eight levels of abduction were considered. Their daily frequency was estimated from in-vivo recorded data on healthy volunteers during activities of daily living. One year of use was simulated to predict the linear and volumetric wear. The volumetric wear was the difference of volume between the original and worn component. Results: With the AP, the contact pattern on the glenoid surface moved rapidly from the inferior to the superior side during the first 30 degrees of abduction, and then went back to the inferior side. With the RP, the contact pattern on the humeral cup surface remained at the inferior side. Contact pressure was 20 times lower with the RP than with the AP. One year of use produced a maximum linear wear of 0.2 mm with the AP, and 0.13 mm with the RP. However, the volumetric wear was 8.4 mm3 with the AP, but reached 44.6 mm3 with the RP. Conclusion: Polyethylene particles are a matter of concern with AP. Infiltration of these particles within the bone-implant interface can induce a implant loosening. This problem should not be underestimated with RP. It might be associated to a higher level of humeral stem loosening reported with RP. The long term survival of RP might be improved by using a highly cross-linked polyethylene, which has a better abrasion resistance but lower plastic resistance.
Resumo:
Introduction: A new ultra congruent, postero-stabilized total knee arthroplasty (TKA) with a mobile bearing, the FIRST knee prosthesis (Free Insert in Rotation Stabilized in Translation, Symbios SA), was designed and expected to significantly reduce polyethylene wear, to improve the range of motion and the overall stability of the knee while ensuring a physiological ligament balance. Gait analysis has proven to give really objective outcome parameters after lower limb surgery. The goal of our study was to compare the subjective and really objective results of this new TKA with two other widespread models of TKA. Methods: A clinical prospective monocentric cohort study of 100 consecutive patients (47-88 yrs) undergoing a FIRST TKA for primary osteoarthritis is currently being done. Pre- and post-operative follow-ups (6 weeks, 4 months and 1 year) were done with well-recognized subjective evaluations (EQ-5D and WOMAC scores) and semi-objective questionnaires (KSS score and radiography evaluation) as well as with a really objective evaluation using gait parameters from 6 walking trials, performed at different speeds (slow, normal and fast) with an ambulatory gait analysis system (Physilog®, BioAGM CH). The outcomes of the first 32 new TKA after one year of follow-up were compared to the results after 1 year of a randomized controlled clinical trial comparing 29 NexGen® postero-stabilized TKA (Zimmer Inc) with a fixed bearing and 26 NexGen® TKA with a mobile bearing using the same methods. Results: Subjective and semi-objective results were similar for the three types of TKA. As for the really objective parameters, the gait cycle time of the FIRST TKA was statistically significantly shorter at normal speed of walk, as well as double-support periods, as compared to both standard models. The extension (in terms of range of motion when walking) of the operated knee was significantly improved for all three types of walk in favour of the FIRST TKAs compared to both NexGen TKAs. The normal walking speed was significantly higher with faster swing speed and stride lengths for the new TKA. Significantly better coordination scores were observed at normal walking speed for the FIRST TKA as compared to the fixed-bearing TKAs. Conclusion: The FIRST TKAs showed statistically significantly better objective outcomes in terms of gait after one year of follow-up with similar subjective and semi-objective results in comparison with widespread TKA designs. These encouraging short-terms results will have to be confirmed at a 5 years follow-up of the FIRST TKAs.
Resumo:
Background: To study the efficacy and safety of a new intravitreal implant (sustained release of dexamethasone, Ozurdex®) recently approved in Switzerland for the treatment of macular edema secondary to retinal vein occlusion in a clinical setting.Patients and Methods: Prospective non-consecutive study of patients with macular edema secondary to central retinal vein occlusion or branch retinal vein occlusion treated with implant of dexamethasone 0.7 mg. Follow-up visits were performed at day 1, week 1 and monthly thereafter. ETDRS best corrected visual acuity, Goldmann tonometry and macular thickness on SD-OCT were registered. Retreatment was carried out on a pro re nata basis starting from month 3.Results: Fifteen eyes of 15 patients were included (8 branch retinal vein occlusions, 7 central retinal vein occlusions). 33 % of the patients achieved 3 lines or more of vision gain. The central retinal vein occlusion subgroup showed a mean decline in visual acuity at month 3. A reduction of 36 % of macular edema was already observed at day 1. All maculae were dry at month 1. The mean time of recurrence of macular edema for both groups was 4.6 months. A similar reduction of macular edema was obtained after a second implantation. An intraocular pressure increase of ≥ 20 % was observed after the first implantation in 53 % of patients.Conclusion: Our study showed efficacy and safety of intravitreal dexamethasone implant in the treatment of macular edema due to retinal vein occlusion. Anatomical efficacy was observed at day 1 but seems to have shorter effect than previously published data. No serious side effects were observed.
Resumo:
Intraclass correlation (ICC) is an established tool to assess inter-rater reliability. In a seminal paper published in 1979, Shrout and Fleiss considered three statistical models for inter-rater reliability data with a balanced design. In their first two models, an infinite population of raters was considered, whereas in their third model, the raters in the sample were considered to be the whole population of raters. In the present paper, we show that the two distinct estimates of ICC developed for the first two models can both be applied to the third model and we discuss their different interpretations in this context.