975 resultados para Electroencephalogram(ECG)


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Unless effective preventive strategies are implemented, aging of the population will result in a significant worsening of the heart failure (HF) epidemic. Few data exist on whether baseline electrocardiographic (ECG) abnormalities can refine risk prediction for HF. METHODS: We examined a prospective cohort of 2,915 participants aged 70 to 79 years without preexisting HF, enrolled between April 1997 and June 1998 in the Health, Aging, and Body Composition (Health ABC) study. Minnesota Code was used to define major and minor ECG abnormalities at baseline and at year 4 follow-up. Using Cox models, we assessed (1) the association between ECG abnormalities and incident HF and (2) the incremental value of adding ECG to the Health ABC HF Risk Score using the net reclassification index. RESULTS: At baseline, 380 participants (13.0%) had minor, and 620 (21.3%) had major ECG abnormalities. During a median follow-up of 11.4 years, 485 participants (16.6%) developed incident HF. After adjusting for the Health ABC HF Risk Score variables, the hazard ratio (HR) was 1.27 (95% CI 0.96-1.68) for minor and 1.99 (95% CI 1.61-2.44) for major ECG abnormalities. At year 4, 263 participants developed new and 549 had persistent abnormalities; both were associated with increased subsequent HF risk (HR 1.94, 95% CI 1.38-2.72 for new and HR 2.35, 95% CI 1.82-3.02 for persistent ECG abnormalities). Baseline ECG correctly reclassified 10.5% of patients with HF events, 0.8% of those without HF events, and 1.4% of the overall population. The net reclassification index across the Health ABC HF risk categories was 0.11 (95% CI 0.03-0.19). CONCLUSIONS: Among older adults, baseline and new ECG abnormalities are independently associated with increased risk of HF. The contribution of ECG screening for targeted prevention of HF should be evaluated in clinical trials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

SUMMARYAim: The embryonic/fetal heart is highly sensitive to oxygenation level and a transient uteroplacental hypoperfusion can lead to oxyradicals overproduction. Information about the molecular mechanisms underlying ischemia-reperfusion (I-R) injury in the developing heart is lacking. The Janus Kinase 2 / Signal Transducer and Activator of Transcription 3 (JAK2/STAT3) pathway, required for cardiogenesis and involved in protection of the adult heart against I-R, could also play a key role in the response of the fetal myocardium to transient oxygen deprivation. The aim of the study was to characterize the involvement of JAK2/STAT3 pathway and its interaction with other signalling pathways in the developing heart transiently submitted to anoxia. Furthermore, the response of the embryonic heart to an exogenous oxidant stress (H2O2) in comparison to reoxygenation-induced endogenous oxyradicals has been investigated.Methods: Hearts isolated from 4-day-old chick embryos were submitted to anoxia (30min) and reoxygenation (80min) with or without the antioxidant MPG, the JAK2/STAT3 inhibitor AG490 or exposed to H202 (50|iM-lmM). The time course of phosphorylation of STAT3atyr0Sine7 and Reperfusion Injury Salvage Kinase (RISK) proteins (PI3K, Akt, GSK3B, Glycogen Synthase and ERK2) was determined in homogenate" and in enriched nuclear and cytoplasmic fractions. The STAT3 DNA-binding was determined by EMSA and the expression of STAT3 specific target genes by RT-PCR. The chrono-, dromo- and inotropic disturbances were also investigated by ECG and mechanical recordings.Results: Phosphorylation of STATSaP (P-Tyr STAT3a) was increased by reoxygenation and reduced by MPG or AG490. STAT3 and GSK36 were detected both in nuclear and cytoplasmic fractions while PI3K, Akt, GS and ERK2 were restricted to cytoplasm. Reoxygenation led to nuclear accumulation of STAT3 but unexpectedly without DNA- binding. AG490 decreased the reoxygenation-induced phosphorylation of STABa^, Akt, GS and ERK2 and phosphorylation/inhibition of GSK3B in the nucleus, exclusively. Inhibition of JAK2/STAT3 delayed recovery of atrial rate, worsened RR. variability and prolonged arrhythmias compared to control hearts. Cardiac activity was altered only at concentrations >500μΜ of H2O2. Moreover, ImM of H2O2 suppressed atrial activity in 45% of the hearts, atrioventricular conduction in 66% and augmented P-Tyr STAT3awhich led to an increase in the DNA-binding but no change in the expression of three STAT3 specific target genes (iNOS, MnSOD, Cox-2).Conclusion: In the developing heart, besides its nuclear translocation without transcriptional activity, ROS-activated STAT3a can rapidly interact with RISK proteins present in nucleus and cytoplasm and reduce the anoxia-reoxygenation-induced arrhythmias. Moreover, the embryonic heart is highly resistant to H2O2 and the atrial region is the less affected. The role of JAK2/STAT3 in the response to reoxygenation-induced oxyradicals is different from the response to strong exogenous oxidant stress where STAT3 DNA-binding activity is increased. Such findings provide a first step in understanding the modulation of signalling cascades in the fetal heart submitted to transient intrauterine oxygen deprivation.RESUMEIntroduction: Le coeur embryonnaire et foetal est très sensible au manque d'oxygène et une hypoperfusion utéroplacentaire transitoire peut conduire à une surproduction d'espèces radicalaires (ROS). Dans le coeur en développement les mécanismes moléculaires impliqués en situation d'ischémie-reperfusion (I-R) ne sont pas connus. La voie de signalisation JAK2/STAT3 (Janus Kinase 2 / Signal Transducer and Activator of Transcription 3), impliquée aussi bien dans la cardiogenèse précoce que dans la protection du coeur adulte contre l'I-R, pourrait jouer un rôle clé dans la réponse du myocarde foetal à un déficit en oxygène. Cette étude a permis d'étudier le rôle de la voie JAK2/STAT3 et son interaction avec d'autres voies de signalisation dans un modèle de coeur embryonnaire soumis à un épisode anoxique. En outre, les effets du stress oxydant endogène provoqué par la réoxygénation ont été comparés à ceux du stress oxydatif exogène induit par du peroxyde d'hydrogène (H2O2).Méthodes: Des coeurs isolés d'embryons de poulet âgés de 4 jours ont été soumis à une anoxie (30min) suivie d'une réoxygénation (80min) en présence ou non de l'antioxydant MPG et de l'inhibiteur de JAK2/STAT3 AG490 ou exposés à de 1Ή202 (50μΜ-1πιΜ). L'évolution temporelle de la phosphorylation de 8ΤΑΤ3α*ΓΟδίη6705 (P-Tyr STAT3a) et celle de la phosphorylation des protéines de la voie RISK (Reperfusion Injury Salvage Kinase: PI3K, Akt, GSK3B, glycogène synthase GS et ERK2) ont été déterminés dans l'homogénat et dans les fractions nucléaire et cytopiasmique du myocarde. La liaison de STAT3 à l'ADN a été déterminée par EMSA et l'expression de gènes cibles de STAT3 (iNOS, MnSOD, Cox2) par RT-PCR. Les effets chrono-, dromo- et inotropes ont été déterminés par les enregistrements de l'ECG et de l'activité contractile ventriculaire.Résultats: STAT3 et GSK3B étaient présents dans les fractions nucléaire et cytopiasmique tandis que PI3K, Akt, GS et ERK2 n'étaient détectées que dans la fraction cytopiasmique. L'augmentation de P-Tyr STAT3a provoquée par la réoxygénation était significativement réduite par le MPG ou PAG490. La réoxygénation entraînait l'accumulation nucléaire de STAT3, mais étonnamment sans liaison avec l'ADN. A la réoxygénation TAG490 diminuait la phosphorylation d'Akt, GS et ERK2 ainsi que celle de GSK36 mais exclusivement dans la fraction nucléaire. L'inhibition de JAK2/STAT3 retardait également la récupération du rythme cardiaque et prolongeait la durée des arythmies. L'activité cardiaque n'était perturbée par de ΓΗ2Ο2 qu'à des concentrations >500μΜ. A ImM, ΓΗ2Ο2 supprimait l'activité auriculaire dans 45% des coeurs et la conduction auriculo-ventriculaire dans 66% et augmentait la formation de P-Tyr STAT3a et sa liaison à l'ADN sans modifier l'expression des gènes cibles.Conclusion: Les ROS produits par l'anoxie-réoxygénation activent STAT3a qui subit une translocation dans le noyau sans se lier à l'ADN et interagit rapidement avec des protéines de la voie RISK dans les compartiments nucléaire et cytopiasmique du coeur embryonnaire. Ce dernier, en particulier au niveau des oreillettes, se révèle très résistant au puissant stress oxydatif de l'H202 qui se différencie du stress lié à la réoxygénation en favorisant la liaison de STAT3 à l'ADN. Ces résultats originaux permettent une meilleure compréhension des mécanismes qui peuvent améliorer la récupération du coeur en développement après un épisode hypoxique intra-utérin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study evaluates for the first time in dogs, the kinetics of green tea catechins and their metabolic forms in plasma and urine. Ten beagles were administered 173 mg (12·35 mg/kg body weight) of catechins as a green tea extract, in capsules. Blood samples were collected during 24 h after intake and urine samples were collected during the following periods of time: 02, 26, 68 and 824 h. Two catechins with a galloyl moiety and three conjugated metabolites were detected in plasma. Most of the detected forms in plasma reached their maximum plasma concentration (Cmax) at around 1 h. Median Cmax for (2)-epigallocatechin-3-gallate (EGCG), (2)-epicatechin-3-gallate (ECG), (2)-epigallocatechin glucuronide (EGCglucuronide), (2)-epicatechin glucuronide (EC-glucuronide), (2)-epicatechin sulphate (EC sulphate) were 0·3 (range 0·11·9), 0·1 (range 00·4), 0·8 (range 0·23·9), 0·2 (range 0·1 1·7) and 1 (range 0·33·4) mmol/l, respectively. The areas under the plasma concentration v. time curves (AUC0!24) were 427 (range 1021185) mmol/l £ min for EGC-glucuronide, 112 (range 53919) mmol/l £ min for EC-sulphate, 71 (range 26306) mmol/l £ min for EGCG, 40 (range 12258) mmol/l £ min for EC-glucuronide and 14 (range 0·1124) mmol/l £ min for ECG. The values of mean residence time (MRT0!24) were 5 (range 216), 2 (range 111), 10 (range 213), 3 (range 216) and 2·4 (range 118) h for EGCG, ECG, EGC-glucuronide, EC-glucuronide and EC sulphate, respectively. In urine, catechins were present as conjugated forms, suggesting bile excretion of EGCG and ECG. Green tea catechins are absorbed following an oral administration and EGC-glucuronide is the metabolic form that remains in the organism for a longer period of time, suggesting that this compound could suffer an enterohepatic cycle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El proyecto nace de la necesidad de ofrecer un método de análisis de apneas por somnolencia que pueda ser utilizado con señales biológicas adquiridas sin contacto, como por ejemplo el ECG. Obtener señales biológicas con sensores sin contacto es muy importante en la monitorización de conductores, ya que la somnolencia al volante es una de las causas de accidente de tráfico más frecuentes, según el último estudio de la DGT. La apnea es un indicador de que el usuario tiene síntomas de cansancio y por ello, en este proyecto, se hace un estudio de variabilidad de señales derivadas del ECG para detectar zonas de fatiga y después caracterización morfológica de la apnea para localizarlas en las regiones de fatiga.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Résumé Contexte: Bon nombre d'études épidémiologiques concernant les premières crises comitiales ont été effectuées principalement sur des populations générales. Cependant, les patients admis dans un hôpital peuvent présenter des éléments cliniques différents. Nous avons donc mené une étude prospective auprès de sujets dans une population hospitalière ayant subi une première crise d'épilepsie, afin d'étudier leur pronostic et le rôle des examens complémentaires (examen neurologique, imagerie cérébrale, examens sanguins, EEG) dans le choix de l'administration d'une médication antiépileptique. Méthodes : Sur une période d'une année, nous avons suivi 177 patients adultes, admis consécutivement, ayant présenté une crise d'épilepsie dont l'évaluation aiguë a été effectuée dans notre hôpital. Pendant 6 mois, nous avons pratiqué pour chaque patient un suivi du traitement antiépileptique, des récidives de crises et d'un éventuel décès. Résultats : L'examen neurologique était anormal dans 72.3% des cas, l'imagerie cérébrale dans 54.8% et les examens sanguins dans 57.1%. L'EEG a montré des éléments épileptiformes dans 33.9% des cas. L'étiologie la plus fréquemment représentée était constituée par des intoxications. Un traitement antiépileptique a été prescrit chez 51% des patients. 31.6% des sujets suivis à six mois ont subi une récidive ; la mortalité s'est élevée à 17.8%. Statistiquement, l'imagerie cérébrale, l'EEG et l'examen neurologique étaient des facteurs prédictifs indépendants pour l'administration d'antiépileptiques, et l'imagerie cérébrale le seul facteur associé au pronostic. Conclusions : Les patients évalués en aigu dans un hôpital pour une première crise comitiale présentent un profil médical sous-jacent, qui explique probablement leur mauvais pronostic. L'imagerie cérébrale s'est avérée être le test paraclinique le plus important dans la prévention du traitement et du pronostic. Mots-clés : première crise d'épilepsie, étiologie, pronostic, récidive, médication antiépileptique, population hospitalière Summary Background: Epidemiological studies focusing on first-ever seizures have been carried out mainly on community based populations. However, since hospital populations may display varying clinical features, we prospectively analysed patients with first-ever seizure in a hospital based community to evaluate prognosis and the role of complementary investigations in the decision to administer antiepileptic drugs (AED). Methods: Over one year, we recruited 177 consecutive adult patients with a first seizure acutely evaluated in our hospital. During six months' follow-up data relating to AED treatment, recurrence of seizures and death were collected for each patient. Results:. Neurological examination was abnormal in 72.3%, neuroimaging in 54.8% and biochemical tests in 57.1%. Electroencephalogram (EEG) showed epileptiform features in 33.9%. Toxicity represented the most common aetiology. AED was prescribed in 51% of patients. Seizure recurrence at six months involved 31.6% of patients completing the follow-up; mortality was 17.8%. Statistical analysis showed that brain CT, EEG and neurological examination are independent predictive factors for AED administration, but only CT scan is associated with outcome. Conclusions: Patients evaluated acutely for first- ever seizure in a hospital setting have severe underlying clinical conditions apparently related to their relatively poor prognosis. Neuroimaging represents the most important paraclinical test in predicting both treatment administration and outcome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: This study aimed to survey current practices in European epilepsy monitoring units (EMUs) with emphasis on safety issues. METHODS: A 37-item questionnaire investigating characteristics and organization of EMUs, including measures for prevention and management of seizure-related serious adverse events (SAEs), was distributed to all identified European EMUs plus one located in Israel (N=150). RESULTS: Forty-eight (32%) EMUs, located in 18 countries, completed the questionnaire. Epilepsy monitoring unit beds are 1-2 in 43%, 3-4 in 34%, and 5-6 in 19% of EMUs; staff physicians are 1-2 in 32%, 3-4 in 34%, and 5-6 in 19% of EMUs. Personnel operating in EMUs include epileptologists (in 69% of EMUs), clinical neurophysiologists trained in epilepsy (in 46% of EMUs), child neurologists (in 35% of EMUs), neurology and clinical neurophysiology residents (in 46% and in 8% of EMUs, respectively), and neurologists not trained in epilepsy (in 27% of EMUs). In 20% of EMUs, patients' observation is only intermittent or during the daytime and primarily carried out by neurophysiology technicians and/or nurses (in 71% of EMUs) or by patients' relatives (in 40% of EMUs). Automatic detection systems for seizures are used in 15%, for body movements in 8%, for oxygen desaturation in 33%, and for ECG abnormalities in 17% of EMUs. Protocols for management of acute seizures are lacking in 27%, of status epilepticus in 21%, and of postictal psychoses in 87% of EMUs. Injury prevention consists of bed protections in 96% of EMUs, whereas antisuffocation pillows are employed in 21%, and environmental protections in monitoring rooms and in bathrooms are implemented in 38% and in 25% of EMUs, respectively. The most common SAEs were status epilepticus reported by 79%, injuries by 73%, and postictal psychoses by 67% of EMUs. CONCLUSIONS: All EMUs have faced different types of SAEs. Wide variation in practice patterns and lack of protocols and of precautions to ensure patients' safety might promote the occurrence and severity of SAEs. Our findings highlight the need for standardized and shared protocols for an effective and safe management of patients in EMUs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

What we put into our mouths can nourish or kill us. A new study uses state-of-the-art electroencephalogram decoding to detail how we and our brains know what we taste.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study evaluates for the first time in dogs, the kinetics of green tea catechins and their metabolic forms in plasma and urine. Ten beagles were administered 173 mg (12·35 mg/kg body weight) of catechins as a green tea extract, in capsules. Blood samples were collected during 24 h after intake and urine samples were collected during the following periods of time: 0-2, 2-6, 6-8 and 8-24 h. Two catechins with a galloyl moiety and three conjugated metabolites were detected in plasma. Most of the detected forms in plasma reached their maximum plasma concentration (Cmax) at around 1 h. Median Cmax for (2)-epigallocatechin-3-gallate (EGCG), (2)-epicatechin-3-gallate (ECG), (2)-epigallocatechin glucuronide (EGCglucuronide), (2)-epicatechin glucuronide (EC-glucuronide), (2)-epicatechin sulphate (EC sulphate) were 0·3 (range 0·1-1·9), 0·1 (range 0-0·4), 0·8 (range 0·2-3·9), 0·2 (range 0·1 1·7) and 1 (range 0·3-3·4) mmol/l, respectively. The areas under the plasma concentration v. time curves (AUC0!24) were 427 (range 102-1185) mmol/l £ min for EGC-glucuronide, 112 (range 53-919) mmol/l £ min for EC-sulphate, 71 (range 26-306) mmol/l £ min for EGCG, 40 (range 12-258) mmol/l £ min for EC-glucuronide and 14 (range 0·1-124) mmol/l £ min for ECG. The values of mean residence time (MRT0!24) were 5 (range 2-16), 2 (range 1-11), 10 (range 2-13), 3 (range 2-16) and 2·4 (range 1-18) h for EGCG, ECG, EGC-glucuronide, EC-glucuronide and EC sulphate, respectively. In urine, catechins were present as conjugated forms, suggesting bile excretion of EGCG and ECG. Green tea catechins are absorbed following an oral administration and EGC-glucuronide is the metabolic form that remains in the organism for a longer period of time, suggesting that this compound could suffer an enterohepatic cycle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To test the hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously using a single four-dimensional (4D) acquisition. METHODS: A free-running 4D whole-heart self-navigated acquisition incorporating a golden angle radial trajectory was implemented and tested in vivo in nine healthy adult human subjects. Coronary magnetic resonance angiography (MRA) datasets with retrospective selection of acquisition window width and position were extracted and quantitatively compared with baseline self-navigated electrocardiography (ECG) -triggered coronary MRA. From the 4D datasets, the left-ventricular end-systolic, end-diastolic volumes (ESV & EDV) and ejection fraction (EF) were computed and compared with values obtained from conventional 2D cine images. RESULTS: The 4D datasets enabled dynamic assessment of the whole heart with isotropic spatial resolution of 1.15 mm(3) . Coronary artery image quality was very similar to that of the ECG-triggered baseline scan despite some SNR penalty. A good agreement between 4D and 2D cine imaging was found for EDV, ESV, and EF. CONCLUSION: The hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously in vivo has been tested positive. Retrospective and flexible acquisition window selection allows to best visualize each coronary segment at its individual time point of quiescence. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study evaluates for the first time in dogs, the kinetics of green tea catechins and their metabolic forms in plasma and urine. Ten beagles were administered 173 mg (12·35 mg/kg body weight) of catechins as a green tea extract, in capsules. Blood samples were collected during 24 h after intake and urine samples were collected during the following periods of time: 0-2, 2-6, 6-8 and 8-24 h. Two catechins with a galloyl moiety and three conjugated metabolites were detected in plasma. Most of the detected forms in plasma reached their maximum plasma concentration (Cmax) at around 1 h. Median Cmax for (2)-epigallocatechin-3-gallate (EGCG), (2)-epicatechin-3-gallate (ECG), (2)-epigallocatechin glucuronide (EGCglucuronide), (2)-epicatechin glucuronide (EC-glucuronide), (2)-epicatechin sulphate (EC sulphate) were 0·3 (range 0·1-1·9), 0·1 (range 0-0·4), 0·8 (range 0·2-3·9), 0·2 (range 0·1 1·7) and 1 (range 0·3-3·4) mmol/l, respectively. The areas under the plasma concentration v. time curves (AUC0!24) were 427 (range 102-1185) mmol/l £ min for EGC-glucuronide, 112 (range 53-919) mmol/l £ min for EC-sulphate, 71 (range 26-306) mmol/l £ min for EGCG, 40 (range 12-258) mmol/l £ min for EC-glucuronide and 14 (range 0·1-124) mmol/l £ min for ECG. The values of mean residence time (MRT0!24) were 5 (range 2-16), 2 (range 1-11), 10 (range 2-13), 3 (range 2-16) and 2·4 (range 1-18) h for EGCG, ECG, EGC-glucuronide, EC-glucuronide and EC sulphate, respectively. In urine, catechins were present as conjugated forms, suggesting bile excretion of EGCG and ECG. Green tea catechins are absorbed following an oral administration and EGC-glucuronide is the metabolic form that remains in the organism for a longer period of time, suggesting that this compound could suffer an enterohepatic cycle.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The 2013 survey addressed the following objectives: Primary objectives : a) Distribution of health behaviors related to NCDs, particularly tobacco use, alcohol drinking, and physical activity ; b) Distribution of the main modifiable risk factors of NCDs, particularly blood pressure, adiposity markers, diabetes and blood lipids ; c) Rates of awareness, treatment and control of hypertension, diabetes and dyslipidemia ; d) Comparison of findings in the survey 2013 with results in previous similar NCD surveys in 1989, 1994, 2004 ; e) Dietary patterns ; f) Knowledge, attitudes and practices related to NCDs and NCD risk factors. Secondary objectives : g) Assessment of indicators of quality of health (e.g. SF‐12) ; h) Assessment of psychological stress and relation with NCD ; i) Assessment of several indicators of frailty (e.g. handgrip strength test, chair strand test, functional limitations) ; j) Assessment of knowledge and level of agreement with current policies on tobacco control ; k) Use of public and private health care services, particularly for NCDs ; l) Exposure to advice on health behaviors given by health professionals at health care level ; m) Burden of chronic diseases not related to the main NCDs (e.g. musculoskeletal, mental health, etc) ; n) Screening of selected cancers ; o) Assessment of the kidney function ; p) Frequency of heart arrhythmias (one‐lead ECG) and heart murmurs (auscultation) ; q) Assessment of bone mineral density (ultrasound of calcaneus) ; r) Exposure of the population to mass media, particularly in relation to health programs, and use by the population of new communication technologies ; s) Assessment of a number of social variables and their association with the variables measured in the survey ; t) More generally, the survey provides broad information (medical, social, environment, etc) that can be useful for tailoring NCD prevention and control programs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Transcranial magnetic stimulation combined with electroencephalogram (TMS-EEG) can be used to explore the dynamical state of neuronal networks. In patients with epilepsy, TMS can induce epileptiform discharges (EDs) with a stochastic occurrence despite constant stimulation parameters. This observation raises the possibility that the pre-stimulation period contains multiple covert states of brain excitability some of which are associated with the generation of EDs. OBJECTIVE: To investigate whether the interictal period contains "high excitability" states that upon brain stimulation produce EDs and can be differentiated from "low excitability" states producing normal appearing TMS-EEG responses. METHODS: In a cohort of 25 patients with Genetic Generalized Epilepsies (GGE) we identified two subjects characterized by the intermittent development of TMS-induced EDs. The high-excitability in the pre-stimulation period was assessed using multiple measures of univariate time series analysis. Measures providing optimal discrimination were identified by feature selection techniques. The "high excitability" states emerged in multiple loci (indicating diffuse cortical hyperexcitability) and were clearly differentiated on the basis of 14 measures from "low excitability" states (accuracy = 0.7). CONCLUSION: In GGE, the interictal period contains multiple, quasi-stable covert states of excitability a class of which is associated with the generation of TMS-induced EDs. The relevance of these findings to theoretical models of ictogenesis is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L'imagerie par résonance magnétique (IRM) peut fournir aux cardiologues des informations diagnostiques importantes sur l'état de la maladie de l'artère coronarienne dans les patients. Le défi majeur pour l'IRM cardiaque est de gérer toutes les sources de mouvement qui peuvent affecter la qualité des images en réduisant l'information diagnostique. Cette thèse a donc comme but de développer des nouvelles techniques d'acquisitions des images IRM, en changeant les techniques de compensation du mouvement, pour en augmenter l'efficacité, la flexibilité, la robustesse et pour obtenir plus d'information sur le tissu et plus d'information temporelle. Les techniques proposées favorisent donc l'avancement de l'imagerie des coronaires dans une direction plus maniable et multi-usage qui peut facilement être transférée dans l'environnement clinique. La première partie de la thèse s'est concentrée sur l'étude du mouvement des artères coronariennes sur des patients en utilisant la techniques d'imagerie standard (rayons x), pour mesurer la précision avec laquelle les artères coronariennes retournent dans la même position battement après battement (repositionnement des coronaires). Nous avons découvert qu'il y a des intervalles dans le cycle cardiaque, tôt dans la systole et à moitié de la diastole, où le repositionnement des coronaires est au minimum. En réponse nous avons développé une nouvelle séquence d'acquisition (T2-post) capable d'acquérir les données aussi tôt dans la systole. Cette séquence a été testée sur des volontaires sains et on a pu constater que la qualité de visualisation des artère coronariennes est égale à celle obtenue avec les techniques standard. De plus, le rapport signal sur bruit fourni par la séquence d'acquisition proposée est supérieur à celui obtenu avec les techniques d'imagerie standard. La deuxième partie de la thèse a exploré un paradigme d'acquisition des images cardiaques complètement nouveau pour l'imagerie du coeur entier. La technique proposée dans ce travail acquiert les données sans arrêt (free-running) au lieu d'être synchronisée avec le mouvement cardiaque. De cette façon, l'efficacité de la séquence d'acquisition est augmentée de manière significative et les images produites représentent le coeur entier dans toutes les phases cardiaques (quatre dimensions, 4D). Par ailleurs, l'auto-navigation de la respiration permet d'effectuer cette acquisition en respiration libre. Cette technologie rend possible de visualiser et évaluer l'anatomie du coeur et de ses vaisseaux ainsi que la fonction cardiaque en quatre dimensions et avec une très haute résolution spatiale et temporelle, sans la nécessité d'injecter un moyen de contraste. Le pas essentiel qui a permis le développement de cette technique est l'utilisation d'une trajectoire d'acquisition radiale 3D basée sur l'angle d'or. Avec cette trajectoire, il est possible d'acquérir continûment les données d'espace k, puis de réordonner les données et choisir les paramètres temporel des images 4D a posteriori. L'acquisition 4D a été aussi couplée avec un algorithme de reconstructions itératif (compressed sensing) qui permet d'augmenter la résolution temporelle tout en augmentant la qualité des images. Grâce aux images 4D, il est possible maintenant de visualiser les artères coronariennes entières dans chaque phase du cycle cardiaque et, avec les mêmes données, de visualiser et mesurer la fonction cardiaque. La qualité des artères coronariennes dans les images 4D est la même que dans les images obtenues avec une acquisition 3D standard, acquise en diastole Par ailleurs, les valeurs de fonction cardiaque mesurées au moyen des images 4D concorde avec les valeurs obtenues avec les images 2D standard. Finalement, dans la dernière partie de la thèse une technique d'acquisition a temps d'écho ultra-court (UTE) a été développée pour la visualisation in vivo des calcifications des artères coronariennes. Des études récentes ont démontré que les acquisitions UTE permettent de visualiser les calcifications dans des plaques athérosclérotiques ex vivo. Cepandent le mouvement du coeur a entravé jusqu'à maintenant l'utilisation des techniques UTE in vivo. Pour résoudre ce problème nous avons développé une séquence d'acquisition UTE avec trajectoire radiale 3D et l'avons testée sur des volontaires. La technique proposée utilise une auto-navigation 3D pour corriger le mouvement respiratoire et est synchronisée avec l'ECG. Trois échos sont acquis pour extraire le signal de la calcification avec des composants au T2 très court tout en permettant de séparer le signal de la graisse depuis le signal de l'eau. Les résultats sont encore préliminaires mais on peut affirmer que la technique développé peut potentiellement montrer les calcifications des artères coronariennes in vivo. En conclusion, ce travail de thèse présente trois nouvelles techniques pour l'IRM du coeur entier capables d'améliorer la visualisation et la caractérisation de la maladie athérosclérotique des coronaires. Ces techniques fournissent des informations anatomiques et fonctionnelles en quatre dimensions et des informations sur la composition du tissu auparavant indisponibles. CORONARY artery magnetic resonance imaging (MRI) has the potential to provide the cardiologist with relevant diagnostic information relative to coronary artery disease of patients. The major challenge of cardiac MRI, though, is dealing with all sources of motions that can corrupt the images affecting the diagnostic information provided. The current thesis, thus, focused on the development of new MRI techniques that change the standard approach to cardiac motion compensation in order to increase the efficiency of cardioavscular MRI, to provide more flexibility and robustness, new temporal information and new tissue information. The proposed approaches help in advancing coronary magnetic resonance angiography (MRA) in the direction of an easy-to-use and multipurpose tool that can be translated to the clinical environment. The first part of the thesis focused on the study of coronary artery motion through gold standard imaging techniques (x-ray angiography) in patients, in order to measure the precision with which the coronary arteries assume the same position beat after beat (coronary artery repositioning). We learned that intervals with minimal coronary artery repositioning occur in peak systole and in mid diastole and we responded with a new pulse sequence (T2~post) that is able to provide peak-systolic imaging. Such a sequence was tested in healthy volunteers and, from the image quality comparison, we learned that the proposed approach provides coronary artery visualization and contrast-to-noise ratio (CNR) comparable with the standard acquisition approach, but with increased signal-to-noise ratio (SNR). The second part of the thesis explored a completely new paradigm for whole- heart cardiovascular MRI. The proposed techniques acquires the data continuously (free-running), instead of being triggered, thus increasing the efficiency of the acquisition and providing four dimensional images of the whole heart, while respiratory self navigation allows for the scan to be performed in free breathing. This enabling technology allows for anatomical and functional evaluation in four dimensions, with high spatial and temporal resolution and without the need for contrast agent injection. The enabling step is the use of a golden-angle based 3D radial trajectory, which allows for a continuous sampling of the k-space and a retrospective selection of the timing parameters of the reconstructed dataset. The free-running 4D acquisition was then combined with a compressed sensing reconstruction algorithm that further increases the temporal resolution of the 4D dataset, while at the same time increasing the overall image quality by removing undersampling artifacts. The obtained 4D images provide visualization of the whole coronary artery tree in each phases of the cardiac cycle and, at the same time, allow for the assessment of the cardiac function with a single free- breathing scan. The quality of the coronary arteries provided by the frames of the free-running 4D acquisition is in line with the one obtained with the standard ECG-triggered one, and the cardiac function evaluation matched the one measured with gold-standard stack of 2D cine approaches. Finally, the last part of the thesis focused on the development of ultrashort echo time (UTE) acquisition scheme for in vivo detection of calcification in the coronary arteries. Recent studies showed that UTE imaging allows for the coronary artery plaque calcification ex vivo, since it is able to detect the short T2 components of the calcification. The heart motion, though, prevented this technique from being applied in vivo. An ECG-triggered self-navigated 3D radial triple- echo UTE acquisition has then been developed and tested in healthy volunteers. The proposed sequence combines a 3D self-navigation approach with a 3D radial UTE acquisition enabling data collection during free breathing. Three echoes are simultaneously acquired to extract the short T2 components of the calcification while a water and fat separation technique allows for proper visualization of the coronary arteries. Even though the results are still preliminary, the proposed sequence showed great potential for the in vivo visualization of coronary artery calcification. In conclusion, the thesis presents three novel MRI approaches aimed at improved characterization and assessment of atherosclerotic coronary artery disease. These approaches provide new anatomical and functional information in four dimensions, and support tissue characterization for coronary artery plaques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chest pain is a common presenting symptom in emergency departments, and a typical manifestation of acute myocardial infarction (AMI). Recognition of ECG changes in AMI is essential for timely diagnosis and treatment. Right bundle branch block (RBBB) may be an isolated sign of AMI, and was previously considered as a criterion for fibrinolytic therapy. Since the most recent European Society of Cardiology and American Heart Association guidelines in 2013, RBBB alone is no longer considered a diagnostic criterion of AMI, even if it occurs in the context of acute chest pain, as RBBB does not usually interfere with the interpretation of ST-segment alteration. Our case illustrates an acute septal myocardial infarction with an isolated RBBB, and thus the importance of recognising this pattern in order to permit timely diagnosis and treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Electroencephalogram (EEG) background reactivity is a potentially interesting outcome predictor in comatose patients, especially after cardiac arrest, but recent studies report only fair interrater reliability. Furthermore, there are no definite guidelines for its testing. We therefore investigated the EEG effect of standardized noxious stimuli in comatose patients not reactive to auditory stimuli. METHODS: In this prospective study we applied a protocol using three different painful stimuli (bilateral nipple pinching, pinprick at the nose base, finger-nail compression on each side), grouped in three distinct clusters with an alternated sequence, during EEG recordings in comatose patients. We only analyzed recordings showing any reactivity to pain. Fisher and χ2 tests were used as needed to assess contingency tables. RESULTS: Of 42 studies, 12 did not show any background reactivity, 2 presented SIRPIDs, and 2 had massive artefacts; we thus analyzed 26 EEGs recorded in 17 patients (4 women, 24%). Nipple pinching more frequently induced a change in EEG background activity (p<0.001), with a sensitivity of 97.4% for reactivity. Neither the order of the stimuli in the cluster (p=0.723), nor the cluster order (p=0.901) influenced the results. CONCLUSION: In this pilot study, bilateral, synchronous nipple pinching seems to be the most efficient method to test nociceptive EEG reactivity in comatose patients. This approach may enhance interrater reliability, but deserves confirmation in larger cohorts.