516 resultados para ENTERAL STENTS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigates a stent-less local delivery system for anti-restenotic agents utilizing antibodies to cross-linked fibrin (XLF). Heparin and low molecular weight heparin (LMWH) were conjugated to an antibody to cross-linked fibrin D-dinner (1D2). Rabbit right carotid arteries were injured with a balloon catheter, then the animals were given a bolus injection of 40 mug/k,g 1D2-heparin (26-70 mug/kg heparin) or 1D2-LMWH (29-80 mug/kg LMWH) conjugates or controls of saline (0.5 ml/kg), heparin (150 U/kg), LMWH (2 mg), or 1D2 (40 mug/kg), with or without a heparin bolus and sacrificed after 2 weeks (8 groups, n = 6/group). The injured artery of rabbits given 1D2-heparin or 1D2-LMWH conjugates had reduced neointimal development, with decreased luminal narrowing and positive remodelling compared with animals given control drugs. Animals given 1D2-heparin conjugate (with a heparin bolus) had three to five times more endothelial cells than the rabbits given saline or unconjugated heparin, while rabbits given 1D2-LMWH conjugate had up to 59% fewer neointimal cells than those given unconjugated drugs. There was little difference in extracellular matrix organization or composition. Thus cross-linked fibrin-antibodies can site-deliver anti-restenotic agents to injured areas of the artery wall where they influence wall remodelling and endothelial and neointimal cell number, reducing neointimal formation without systemic complications. Local delivery of anti-restenotic agents should minimise systemic effects, bleeding complications and potentially the cost of treatment due to a single, lower dose. (C) 2004 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The Lescol Intervention Prevention Study (LIPS) was a multinational randomized controlled trial that showed a 47% reduction in the relative risk of cardiac death and a 22% reduction in major adverse cardiac events (MACEs) from the routine use of fluvastatin, compared with controls, in patients undergoing percutaneous coronary intervention (PCI, defined as angioplasty with or without stents). In this study, MACEs included cardiac death, nonfatal myocardial infarction, and subsequent PCI and coronary artery bypass graft. Diabetes was the greatest risk factor for MACEs. Objective: This study estimated the cost-effectiveness of fluvastatin when used for secondary prevention of MACEs after PCI in people with diabetes. Methods: A post hoc subgroup analysis of patients with diabetes from the LIPS was used to estimate the effectiveness of fluvastatin in reducing myocardial infarction, revascularization, and cardiac death. A probabilistic Markov model was developed using United Kingdom resource and cost data to estimate the additional costs and quality-adjusted life-years (QALYs) gained over 10 years from the perspective of the British National Health Service. The model contained 6 health states, and the transition probabilities were derived from the LIPS data. Crossover from fluvastatin to other lipid-lowering drugs, withdrawal from fluvastatin, and the use of lipid-lowering drugs in the control group were included. Results: In the subgroup of 202 patients with diabetes in the LIPS trial, 18 (15.0%) of 120 fluvastatin patients and 21 (25.6%) of 82 control participants were insulin dependent (P = NS). Compared with the control group, patients treated with fluvastatin can expect to gain an additional mean (SD) of 0.196 (0.139) QALY per patient over 10 years (P < 0.001) and will cost the health service an additional mean (SD) of 10 (E448) (P = NS) (mean [SD] US $16 [$689]). The additional cost per QALY gained was;(51 (US $78). The key determinants of cost-effectiveness included the probabilities of repeat interventions, cardiac death, the cost of fluvastatin, and the time horizon used for the evaluation. Conclusion: Fluvastatin was an economically efficient treatment to prevent MACEs in these patients with diabetes undergoing PCI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The durability of all forms of open or percutaneous revascularisation is affected by the development of localised stenoses within the bypass graft or at the site of endarterectomy, stent or angioplasty. The reported incidence of significant restenosis has varied dependent on initial procedure, site, case mix and definition, but is greatest during the first 12 months (Table 1).1 Over the last 40 years tens of thousands of studies have been carried out in an effort to understand or reduce the incidence of restenosis, with two major mechanisms identified as being responsible for the luminal narrowing, namely intimal hyperplasia and constrictive remodelling. Intimal hyperplasia is provoked by changes in the balance of local cytokines controlling vascular smooth muscle cell (VSMC) proliferation, apoptosis and migration, brought about by endothelial or medial injury and alterations in haemodynamic forces. The overall vessel diameter reduction that occurs in constrictive remodelling is less well defined, but likely involves matrix turnover under the control of proteinases, particularly metalloproteinases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 52-year-old male with idiopathic hypereosinophilic syndrome (HES) was transferred to our institution following the development of acute respiratory failure and shock. He had previously undergone tricuspid valve replacement with bioprosthetic valves on two occasions: the initial surgery for severe native tricuspid valve stenosis and the redo surgery for severe prosthetic valve stenosis and regurgitation. Conventional imaging assessment using transoesophageal echocardiography was suboptimal and comprehensive assessment of prosthetic valve function was aided by the use of intracardiac echocardiography (ICE). ICE provided high quality 2D imaging of the prosthesis demonstrating thrombus-like material coating the inner surfaces of the prosthetic valve stents effectively forming a tunnel-like obstruction. Unusual hemodynamics secondary to severe tricuspid stenosis were demonstrated by CW Doppler with intermittent signal fusion resulting from blunted respiratory variation in the markedly elevated right atrial pressure relative to right ventricular pressure. Successful balloon valvuloplasty was performed with ICE proving highly valuable in guiding balloon position as well as monitoring the efficacy of the subsequent inflations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis concerns the mechanism through which enteral delivery of glucose results in a larger insulin response than an equivalent parenteral glucose load. Preliminary studies in which mice received a glucose solution either intragastrically or intraperitoneally confirmed this phenomenon. An important regulatory system in this respect is the entero-insular axis, through which insulin secretion is influenced by neural and endocrine communication between the gastrointestinal tract and the pancreatic islets of Langerhans. Using an in vitro system involving static incubation of isolated (by collagenase digestion) islets of Langerhans, the effect of a variety of gastrointestinal peptides on the secretion of the four main islet hormones, namely insulin, glucagon, somatostatin and pancreatic polypeptide, was studied. The gastrointestinal peptides investigated in this study were the secretin family, comprising secretin, glucagon, gastric inhibitory polypeptide (GIP), vasoactive intestinal polypeptide (VIP), peptide histidine isoleucine (PHI) and growth hormone releasing factor (GRF). Gastrin releasing peptide (GRP) was also studied. The results showed that insulin release was stimulated by all peptides studied except PHI, glucagon release was stimulated by all peptides tested, except GRF which suppressed glucagon release, somatostatin release was stimulated by GIP and GRF but suppressed by VIP, PHI, glucagon and secretin, and PP release was stimulated by GIP and GRF, but suppressed by PHI. The insulinotropic effect of GRP was investigated further. A perifusion system was used to examine the time-course of insulin release from isolated islets after stimulation with GRP. GRP was shown to be insulinotropic only in the presence of physiologically elevated glucose concentrations and both first and second phases of insulin release were augmented. There was no effect at substimulatory or very high glucose concentrations. Studies using a cultured insulin-secreting islet cell line, the RINm5F cell line, were undertaken to elucidate the intracellular mechanism of action of GRP. This peptide did not enhance insulin release via an augmentation of glucose metabolism, or via the adenylate cyclase/cyclic AMP secondary messenger system. The pattern of changes of cytosolic free calcium in response to GRP, which involved both mobilization of intracellular stores and an influx of extracellular calcium, suggested the involvement of phosphatidylinositol bisphosphate breakdown as a mediator of the effect of GRP on insulin secretion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Central venous catheters (CVCs) are being utilized with increasing frequency in intensive care and general medical wards. In spite of the extensive experience gained in their application, CVCs are related to the long-term risks of catheter sheath formation, infection, and thrombosis (of the catheter or vessel itself) during catheterization. Such CVC-related-complications are associated with increased morbidity, mortality, duration of hospitalization, and medical care cost [1]. The present study incorporates a novel group of Factor XIIIa (FXIIIa, plasma transglutaminase) inhibitors into a lubricious silicone elastomer in order to generate an optimized drug delivery system whereby a secondary sustained drug release profile occurs following an initial burst release for catheters and other medical devices. We propose that the incorporation of FXIIIa inhibitors into catheters, stents, and other medical implant devices would reduce the incidence of catheter sheath formation, thrombotic occlusion, and associated staphylococcal infection. This technique could be used as a local delivery system for extended release with an immediate onset of action for other poorly aqueous soluble compounds. © 2012 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In obese patients bariatric surgery is increasing in popularity as a strategy to promote, and maintain, weight loss. In obese type 2 diabetes bypass, bariatric surgery improves glycaemic control g€" often to a greater extent than would be anticipated by weight loss alone. Surgical bypass procedures appear to initially offer a greater glucose-lowering effect than surgical restriction procedures. This review considers the rationale for bariatric surgery as a treatment for diabesity and the implications of the different procedures on the secretion and action of enteral hormones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This dissertation presents dynamic flow experiments with fluorescently labeled platelets to allow for spatial observation of wall attachment in inter-strut spacings, to investigate their relationship to flow patterns. Human blood with fluorescently labeled platelets was circulated through an in vitro system that produced physiologic pulsatile flow in (1) a parallel plate blow chamber that contained two-dimensional (2D) stents that feature completely recirculating flow, partially recirculating flow, and completely reattached flow, and (2) a three-dimensional (3D) cylindrical tube that contained stents of various geometric designs. ^ Flow detachment and reattachment points exhibited very low platelet deposition. Platelet deposition was very low in the recirculation regions in the 3D stents unlike the 2D stents. Deposition distal to a strut was always high in 2D and 3D stents. Spirally recirculating regions were found in 3D unlike in 2D stents, where the deposition was higher than at well-separated regions of recirculation. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is projected that by 2020, there will be 138 million Americans over 45, the age at which the increased incidence of heart diseases is documented. Many will require stents. This multi-billion dollar industry, with over 2 million patients worldwide, 15% of whom use Nitinol stents have experienced a decline in sales recently, due in part to thrombosis. It is a sudden blood clot that forms inside stents. As a result, the Food and Drug Administration and American Heart Association are calling for a new generation of stents, new designs and different alloys that are more adaptable to the arteries. The future of Nitinol therefore depends on a better understanding of the mechanisms by which Nitinol surfaces can be rendered stable and inert. In this investigation, binary and ternary Nitinol alloys were prepared and subjected to various surface treatments such as electropolishing (EP), magnetoelectropolishing (MEP) and water boiling & passivation (W&P). In vitro corrosion tests were conducted on Nitinol alloys in accordance with ASTM F 2129-08. The metal ions released into the electrolyte during corrosion tests were measured by Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). Biocompatibility was assessed by observing the growth of human umbilical vein endothelial cells (HUVEC) on the surface of Nitinol alloys. Static and dynamic immersion tests were performed by immersing the Nitinol alloys in cell culture media and measuring the amount of metal ions released in solution. Sulforhodamine B (SRB) assays were performed to elucidate the effect of metal ions on the growth of HUVEC cells. The surfaces of the alloys were studied using Scanning Electron Microscopy (SEM) and X-ray Photoelectron Spectroscopy (XPS) respectively. Finally, wettability and surface energy were measured by Contact Angle Meter, whereas surface roughness was measured by Atomic Force Microscopy (AFM). All the surface treated alloys exhibited high resistance to corrosion when compared with untreated alloys. SRB assays revealed that Ni and Cu ions exhibited greater toxicity than Cr, Ta and Ti ions on HUVEC cells. EP and MEP alloys possessed relatively smooth surfaces and some were composed of nickel oxides instead of elemental nickel as determined by XPS. MEP exhibited lowest surface energy and lowest surface roughness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, an Atomic Force Microscopy (AFM) roughness analysis was performed on non-commercial Nitinol alloys with Electropolished (EP) and Magneto-Electropolished (MEP) surface treatments and commercially available stents by measuring Root-Mean-Square (RMS) , Average Roughness (Ra), and Surface Area (SA) values at various dimensional areas on the alloy surfaces, ranging from (800 x 800 nm) to (115 x 115µm), and (800 x 800 nm) to (40 x 40 µm) on the commercial stents. Results showed that NiTi-Ta 10 wt% with an EP surface treatment yielded the highest overall roughness, while the NiTi-Cu 10 wt% alloy had the lowest roughness when analyzed over (115 x 115 µm). Scanning Electron Microscopy (SEM) and Energy Dispersive Spectroscopy (EDS) analysis revealed unique surface morphologies for surface treated alloys, as well as an aggregation of ternary elements Cr and Cu at grain boundaries in MEP and EP surface treated alloys, and non-surface treated alloys. Such surface micro-patterning on ternary Nitinol alloys could increase cellular adhesion and accelerate surface endothelialization of endovascular stents, thus reducing the likelihood of in-stent restenosis and provide insight into hemodynamic flow regimes and the corrosion behavior of an implantable device influenced from such surface micro-patterns.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Owing to an increased risk of aging population and a higher incidence of coronary artery disease (CAD), there is a need for more reliable and safer treatments. Numerous varieties of durable polymer-coated drug eluting stents (DES) are available in the market in order to mitigate in-stent restenosis. However, there are certain issues regarding their usage such as delayed arterial healing, thrombosis, inflammation, toxic corrosion by-products, mechanical stability and degradation. As a result, significant amount of research has to be devoted to the improvement of biodegradable polymer-coated implant materials in an effort to enhance their bioactive response. ^ In this investigation, magneto-electropolished (MEP) and a novel biodegradable polymer coated ternary Nitinol alloys, NiTiTa and NiTiCr were prepared to study their bio and hemocompatibility properties. The initial interaction of a biomaterial with its surroundings is dependent on its surface characteristics such as, composition, corrosion resistance, work of adhesion and morphology. In-vitro corrosion tests such as potentiodynamic polarization and electrochemical impedance spectroscopic (EIS) studies were conducted to determine the coating stability and longevity. In-vitro hemocompatibility studies and HUVEC cell growth was performed to determine their thrombogenic and biocompatibility properties. Critical delamination load of the polymer coated Nitinol alloys was determined using Nano-scratch analysis. Sulforhodamine B (SRB) assays were performed to elucidate the effect of metal ions leached from Nitinol alloys on the viability of HUVEC cells. Scanning Electron Microscopy (SEM), X-ray Photoelectron Spectroscopy (XPS), contact angle meter and X-ray diffraction (XRD) were used to characterize the surface of the alloys. ^ MEP treated and polymer coated (PC) Nitinol alloys displayed a corrosion resistant polymer coating as compared to uncoated alloys. MEP and PC has resulted in reduced Ni and Cr ion leaching from NiTi5Cr and subsequently low cytotoxicity. Thrombogenicity tests revealed significantly less platelet adhesion and confluent endothelial cell growth on polymer coated and uncoated ternary MEP Nitinol alloys. Finally, this research addresses the bio and hemocompatibility of MEP + PC ternary Nitinol alloys that could be used to manufacture blood contacting devices such as stents and vascular implants which can lead to lower U.S. healthcare spending.^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is projected that by 2020, there will be 138 million Americans over 45, the age at which the increased incidence of heart diseases is documented. Many will require stents. This multi-billion dollar industry, with over 2 million patients worldwide, 15% of whom use Nitinol stents have experienced a decline in sales recently, due in part to thrombosis. It is a sudden blood clot that forms inside stents. As a result, the Food and Drug Administration and American Heart Association are calling for a new generation of stents, new designs and different alloys that are more adaptable to the arteries. The future of Nitinol therefore depends on a better understanding of the mechanisms by which Nitinol surfaces can be rendered stable and inert. In this investigation, binary and ternary Nitinol alloys were prepared and subjected to various surface treatments such as electropolishing (EP), magnetoelectropolishing (MEP) and water boiling & passivation (W&P). In vitro corrosion tests were conducted on Nitinol alloys in accordance with ASTM F 2129-08. The metal ions released into the electrolyte during corrosion tests were measured by Inductively Coupled Plasma Mass Spectroscopy (ICP-MS). Biocompatibility was assessed by observing the growth of human umbilical vein endothelial cells (HUVEC) on the surface of Nitinol alloys. Static and dynamic immersion tests were performed by immersing the Nitinol alloys in cell culture media and measuring the amount of metal ions released in solution. Sulforhodamine B (SRB) assays were performed to elucidate the effect of metal ions on the growth of HUVEC cells. The surfaces of the alloys were studied using Scanning Electron Microscopy (SEM) and X-ray Photoelectron Spectroscopy (XPS) respectively. Finally, wettability and surface energy were measured by Contact Angle Meter, whereas surface roughness was measured by Atomic Force Microscopy (AFM). All the surface treated alloys exhibited high resistance to corrosion when compared with untreated alloys. SRB assays revealed that Ni and Cu ions exhibited greater toxicity than Cr, Ta and Ti ions on HUVEC cells. EP and MEP alloys possessed relatively smooth surfaces and some were composed of nickel oxides instead of elemental nickel as determined by XPS. MEP exhibited lowest surface energy and lowest surface roughness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To identify the inpatient maternal and neonatal factors associated to the weaning of very low birth weight (VLBW) infants. METHODS: One hundred nineteen VLBW (<1500 g) infants were monitored from July 2005 through August 2006, from birth to the first ambulatory visit after maternity discharge. This maternity unit uses the Kangaroo Method and the Baby Friendly Hospital Initiative. Out of 119 VLBW infants monitored until discharge, 88 (75%) returned to the facility, 22 (25%) were on exclusive breastfeeding (EB), and 66 (75%) were weaned (partial breastfeeding or formula feeding). RESULTS: Univariate analysis found an association between weaning and lower birth weight, longer stays in the neonatal intensive care unit (NICU), and longer hospitalization times, in addition to more prolonged enteral feeding and birth weight recovery period. Logistic regression showed length of NICU stay as being the main determinant of weaning. CONCLUSION: The negative repercussion on EB of an extended stay in the NICU is a significant challenge for health professionals to provide more adequate nutrition to VLBW infants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To identify the inpatient maternal and neonatal factors associated to the weaning of very low birth weight (VLBW) infants. METHODS: One hundred nineteen VLBW (<1500 g) infants were monitored from July 2005 through August 2006, from birth to the first ambulatory visit after maternity discharge. This maternity unit uses the Kangaroo Method and the Baby Friendly Hospital Initiative. Out of 119 VLBW infants monitored until discharge, 88 (75%) returned to the facility, 22 (25%) were on exclusive breastfeeding (EB), and 66 (75%) were weaned (partial breastfeeding or formula feeding). RESULTS: Univariate analysis found an association between weaning and lower birth weight, longer stays in the neonatal intensive care unit (NICU), and longer hospitalization times, in addition to more prolonged enteral feeding and birth weight recovery period. Logistic regression showed length of NICU stay as being the main determinant of weaning. CONCLUSION: The negative repercussion on EB of an extended stay in the NICU is a significant challenge for health professionals to provide more adequate nutrition to VLBW infants.