Effect of blood flow patterns on localized platelet adhesion under physiologic flow conditions using two-dimensional and three-dimensional stent models: An experimental and computational approach


Autoria(s): Duraiswamy, Nandini
Data(s)

01/01/2005

Resumo

This dissertation presents dynamic flow experiments with fluorescently labeled platelets to allow for spatial observation of wall attachment in inter-strut spacings, to investigate their relationship to flow patterns. Human blood with fluorescently labeled platelets was circulated through an in vitro system that produced physiologic pulsatile flow in (1) a parallel plate blow chamber that contained two-dimensional (2D) stents that feature completely recirculating flow, partially recirculating flow, and completely reattached flow, and (2) a three-dimensional (3D) cylindrical tube that contained stents of various geometric designs. ^ Flow detachment and reattachment points exhibited very low platelet deposition. Platelet deposition was very low in the recirculation regions in the 3D stents unlike the 2D stents. Deposition distal to a strut was always high in 2D and 3D stents. Spirally recirculating regions were found in 3D unlike in 2D stents, where the deposition was higher than at well-separated regions of recirculation. ^

Identificador

http://digitalcommons.fiu.edu/dissertations/AAI3206022

Idioma(s)

EN

Publicador

FIU Digital Commons

Fonte

ProQuest ETD Collection for FIU

Palavras-Chave #Engineering, Biomedical
Tipo

text