602 resultados para Aparelhos ortodônticos removíveis
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundamentation: The correction of maxillary transverse deficiencies involves orthodontic and surgical procedures that can be performed before or after skeletal maturity. The surgically assisted rapid maxillary expansion (SAR ME) is performed by osteotomies through the lateral walls of the maxilla, zygomatic and canines buttresses, palatal and pterygomaxillary sutures, causing the maxillary disjunction. Followed by activation of the expander to the desired over-expansion in order to correct intercuspal later. Objective: The purpose of this study was to discuss the issues involved in the diagnosis of maxillary atresia, SAR ME indications, as well as surgical technique, through a case study. Methods: The male patient, 19 years old, had severe transverse maxillary deficiency with facial pattern III , Class III , with great lip incompetence. The patient underwent general anesthesia in a hospital environment, the osteotomies was done according to the technique described by Epker and Wolford (1980). Postoperatively, the patient underwent activations daily for 15 days and after 6 months, the orthodontist installed fixed orthodontic appliance to prepare the patient to orthognathic surgery later. Conclusion: The diagnosis by clinical evaluation and models study is essential for the indication of SAR ME and this procedure provides good predictability in the correction of transverse deficiency, with minimal morbidity.
Resumo:
Risk of mechanical injuries contraindicate brushing and elect chemical agents as appropriate for daily cleaning of dentures relined with resilient materials. It was evaluated the effect of denture cleansers on the wettability of denture relining material (Dentusoft, Dental Medrano). We used 20 discs of acrylic resin thermoactivated VipiCril ® with 30mm diameter and 4mm thick, covered by 2mm Dentusoft ®. Divided into 4grupos were stored in artificial saliva at 37 +1 º C for 30 days, immersed daily for 15minutes in distilled water (GI), Corega ® Tabs (GII), a solution of sodium bicarbonate (GIII) or solution of sodium hypochlorite (GIV) after which, on the soft liner were poured 2 ml of type IV gypsum (Durone IV, Dentsply). Reached the final setting of the gypsum specimens were sectioned vertically and medially, settled water with sandpaper No. 400 and mounted on suitable device for reading (in the right and left) of the contact angle Carl Zeiss microscope (precision, 001). The results were submitted to analysis, showed non-normal distribution, opting for non-parametric test. Kruskal Wallis test performed at 5% significance, there was statistical difference between the groups with lower average contact angle for GII. It was concluded that the chemical cleaning Corega Tabs ® allowed a better adaptation of relining the gypsum studied.
Resumo:
The literature has suggested that the association of removable partial dentures with dental implants can improve the quality of life of patients. Thus, the purpose of this study was to present a case report. This case report describes the development of a removable partial denture associated with dental implants bilaterally been monitored for 12 years, and the efficacy of the proposed treatment. The radiographic controls demonstrated no changes on bone tissue. The maxillary arch was rehabilitated with metal-free crowns. The patient was fully satisfied with this technique providing stability, esthetics, and proper function. It was concluded that the technique of using removable partial dentures associated with dental implants is viable and show the advantages of improved function, aesthetics and cost reductions in rehabilitation treatment.
Resumo:
The obstructive sleep apnea syndrome affects millions of people around the world. The mandibular repositioning devices have been indicated in cases of mild/moderate syndrome; however in edentulous patients its use is deficient since there is no retention. Therefore the objective of this study was to conduct a review on the use of this treatment method combined to osseointegrated implants. A search on the theme: Dental implant and sleep apnea syndromewas performed in the Medline/PubMed, ISI, Cochrane, Dentistry Oral Science, Clinical Trials, Controlled Trials, and Bireme-BvS, databases, and 22 articles were found. After anevaluation 2 studies were selected and the review was complemented with an analysis of randomized controlled trials in the previous seven bases using the key-words: Sleep apnea syndrome, Oral appliance and Randomized controlled trial. The search returned 37 articles, and after they were submitted to inclusion criteria 17 studies were selected. There are a small number of studies presenting the use of dental implants as a mean to assist the stabilization of the mandibular repositioning appliances; those that are available are case reports that focusing on the effectiveness of the technique. Studies examining the effect these appliances in dentate patients indicate improvement in the levels of apnea and snoring. The use of mandibular repositioning appliances in dentate patients is an effective technique in treatment of patients with obstructive sleep apnea syndrome mild/moderate. Randomized controlled trialsare required in order to enable an analysis of the use of mandibular repositioning devices with the aid of dental implants .
Resumo:
The modalities of treatment with prostheses over implants for total edentulous patients can be divided in fixed and removable prostheses (overdentures). The fixed prostheses modality has proven to offer better results as to the functional aspects and, results in higher longevity. Overdentures are considered as a modality of rehabilitation utilized to compensate the need for better retention, aside from augmenting chewing efficiency. Its use is justified by its facilitated hygiene, reduced surgical and prosthetic costs, reestablishment of labial support and elimination of the possibility of air escape. However, this option presents psychosocial downside, since the fact that it is considered a removable rehabilitation modality does not please the majority of patients. Although many patients prefer a fixed implant-supported prosthesis to a removable overdenture, frequently it is necessary to utilize an implant retained overdenture as an alternative to the treatment, due to anatomical, physiological, aesthetic, hygienic, and financial limitations regarding the patient. The objective of this study was to discuss a clinical case of a partially edentulous patient treated in the Implantodontic Surgery Post-Graduation Course from the Kenedy Dentistry Institute Mozarteum/Famosp Unit – Goiânia-Brazil), and submitted to osseointegrated implants surgical fixation techniques. A modality of differential diagnosis was established after osseointegration period, it aimed at facilitating the choice of a rehabilitation model that could favor the patient’s and professional`s expectations. Therefore the appreciated aspects were function, comfort, aesthetics, and especially the patient satisfaction.
Resumo:
Nowadays the search for aesthetic in removable dentures is considered a success clinical factor. Besides, both the selection of artificial denture teeth and the characterization of dentures have been based on the facial harmony and cultural factors. But these factors change over time. Therefore, the present study aimed to discuss the selection of artificial denture teeth in relation to patient’s variables such as face shape, skin color, hair color, eye color, age and gender. Moreover, artificial denture teeth’ color, shape and size were presented.
Resumo:
The purpose of this study was to evaluate, in vitro, the chromatic behavior of esthetic brackets stored in potentially staining solutions. The sample were divided into four groups according to the commercial brand and stored in four different solutions (distilled water, cola soda, coffee and mouthrinse) at 37°C for 14 days. Possible color changes measured according to the CIE L*a*b* color system with a spectrophotometer at five intervals of time after storage. The statistical analysis was carried out using ANOVA to 1%, Tukey's tests and decomposition of interactions with a significance level of 5%.The color changes were dependent on the solution, storage time and the brand of brackets. The largest color changes were observed in the G3, followed by G2, G1/G4. The esthetic brackets do not present satisfactory and stable chromatic behavior.
Resumo:
In the last decade mini-screws have gained popularity in orthodontics field and a correct placement of mini-screws is a critical point to the success of the skeletal anchorage. A careful clinical and radiographic diagnostic before insertion mini-screw is an essential requirement to achieve the central point of the radicular septum. The correct application of these pre-surgical procedures should avoid possible iatrogenic damages in periodontal ligament, dental roots, nasomaxillary cavities, or even important vascular tissues. As of today, periapical radiographs is a regular pre surgical procedure during mini-screw insertion technique. Nevertheless, accurate execution of the radiographic parallax technique can offer to us useful and precise radiographic images, to decide the right local insertion of mini-screws in to the septum bone. The purpose of this paper is to describe the ¬application of new positioning circular guides in conjunction with a ¬parallax radiographic protocol before placement of orthodontic mini-screws.
Resumo:
Recent orthodontic bonding materials have aimed to reduce the working time of the clinician, by simplifying the acid etching procedure by applying self-etching primer adhesive systems. However, the adhesion quality of these materials still demands investigation. Thus, the present study aimed to evaluate the bond strengths of three different adhesive systems. A hundred and eighty bovine lower incisors were cut and embebbed in acrylic resin matrices, in which orthodontic brackets were bonded with Transbond XT (2n = 60), Transbond XT Self Etching Primer (2n = 60) e Tyrian (2n = 60). For each composite, bond strength tests were executed immediately (n = 30) and 24 hours (n = 30) after the bonding, in the assay machine Versat 2000 (Pantec), by applying 500 Kgf of load at 1mm/min of velocity. Transbond XT, Transbond XT Self Etching Primer and Tyrian presented, respectively, average values of bond strength of 7.43, 7.09 and 3.41 MPa at the time immediately, and 7.42, 8.81 and 5.35 MPa at 24 hours after the bonding, where differences were statistically significant at 5% between Tyrian and Transbond groups at both observation times. It was concluded that Tyrian was the material that presented significant lower bond strength with regard to Transbond groups that were similar.
Resumo:
O tratamento endodôntico é de fundamental importância para abolir a infecção nos dentes com necrose pulpar. O sucesso desse tratamento depende: da eliminação eficiente da infecção no sistema de canais radiculares (SCR) e do correto selamento pela obturação dos canais radiculares. Devido à complexidade anatômica do SCR, certas áreas podem ser inacessíveis ao preparo biomecânico (PBM), portanto, o emprego de uma medicação intracanal potencializa a redução dos microrganismos (MO) e seus produtos tóxicos no SCR. Mesmo com o avanço técnico e científico da Endodontia, há MO que ainda sobrevivem ao PBM, sendo os principais responsáveis pela manutenção infecção endodôntica. Assim, novos tratamentos devem ser pesquisados. Com o advento dos aparelhos de laser e LED, surgiram alternativas de tratamentos na área da saúde, como a terapia fotodinâmica (TFD), que é um conjunto de procedimentos físicos, químicos e biológicos, que ocorrem após a administração de um agente fotossensibilizador (FS) ativado por meio de uma luz visível de comprimento de onda específico (laser ou LED) para destruir a célula-alvo, ou auxiliar no combate das infecções. Na Endodontia, foram demonstrados em estudos in vitro e in vivo que o emprego da TFD atua como um coadjuvante e potencializa a desinfecção do SCR, além de ser de fácil aplicação e não promover resistência microbiana. O objetivo da presente revisão é apresentar o estado atual da terapia fotodinâmica em Endodontia.
Resumo:
In part I of this article, the factors related to the establishment of a favourable occlusion for the implant prosthodontics as well as its real importance in this kind of rehabilitation were showed up. However, it is known that the occlusal characteristics adopted in implant prosthodontics show specific patterns which must be different between each other in accordance to the type of prosthesis installed. The objective of the second part of this work is to present to the reader, by a literature review, those characteristics, justifying the reason because they must be associated to specific kind of prosthesis for favor the treatment established.
Resumo:
Objetivo: a proposta desse estudo foi avaliar, por meio de microscopia eletrônica de varredura (MEV), a interface adesiva após a descolagem de acessórios ortodônticos, fixados em dentes bovinos com emprego de adesivo hidrofílico e hidrofóbico, em condições distintas de umidade do substrato dentário. Métodos: foram utilizados 20 incisivos inferiores, divididos em quatro grupos (n = 5): Grupo I , empregou-se o sistema de colagem contendo o primer hidrofílico Transbond MIP e a pasta adesiva Transbond XT, aplicados em substrato úmido; Grupo II, empregou-se o sistema de colagem primer hidrofóbico Transbond XT e pasta adesiva em substrato úmido; Grupos III e IV, os braquetes foram colados com os mesmos sistemas de união dos Grupos I e II, porém com esmalte dentário seco. Removidos os acessórios, avaliou-se em MEV, em diferentes magnificações, a interface adesiva e a interação dos sistemas adesivos com o esmalte dentário. As imagens foram avaliadas qualitativamente, observando-se o embricamento mecânico para o adesivo hidrófilo em quaisquer condições de substrato. Resultados: a falta de umidade no esmalte condicionado permitiu uma melhor interação entre os materiais de ligação e a estrutura adamantina. O adesivo hidrofóbico apresentou o pior resultado de interação micromecânica quando aplicado a uma estrutura dentária úmida; já o sistema hidrofílico mostrou-se versátil, obtendo resultados aceitáveis em condições de umidade e excelente interação na ausência de contaminação. Conclusão: os autores afirmam que a melhor condição do esmalte dentário para a aplicação de primers é com a ausência de umidade.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)