893 resultados para peak-to-plateau ratio
Resumo:
Objective: The epilepsy associated with the hypothalamic hamartomas constitutes a syndrome with peculiar seizures, usually refractory to medical therapy, mild cognitive delay, behavioural problems and multifocal spike activity in the scalp electroencephalogram (EEG). The cortical origin of spikes has been widely assumed but not specifically demonstrated. Methods: We present results of a source analysis of interictal spikes from 4 patients (age 2–25 years) with epilepsy and hypothalamic hamartoma, using EEG scalp recordings (32 electrodes) and realistic boundary element models constructed from volumetric magnetic resonance imaging (MRIs). Multifocal spike activity was the most common finding, distributed mainly over the frontal and temporal lobes. A spike classification based on scalp topography was done and averaging within each class performed to improve the signal to noise ratio. Single moving dipole models were used, as well as the Rap-MUSIC algorithm. Results: All spikes with good signal to noise ratio were best explained by initial deep sources in the neighbourhood of the hamartoma, with late sources located in the cortex. Not a single patient could have his spike activity explained by a combination of cortical sources. Conclusions: Overall, the results demonstrate a consistent origin of spike activity in the subcortical region in the neighbourhood of the hamartoma, with late spread to cortical areas.
Resumo:
Background and Objective: Drug-induced anaphylaxis is an unpredictable and potentially fatal adverse drug reaction. The aim of this study was to identify the causes of drug-induced anaphylaxis in Portugal. Methods: During a 4-year period a nationwide notification system for anaphylaxis was implemented, with voluntary reporting by allergists. Data on 313 patients with drug anaphylaxis were received and reviewed. Statistical analysis included distribution tests and multiple logistic regression analysis to investigate significance, regression coefficients, and marginal effects. Results: The mean (SD) age of the patients was 43.8 (17.4) years, and 8.3% were younger than 18 years. The female to male ratio was 2:1. The main culprits were nonsteroidal anti-inflammatory drugs (NSAIDs) (47.9% of cases), antibiotics (35.5%), and anesthetic agents (6.1%). There was a predominance of mucocutaneous symptoms (92.2%), followed by respiratory symptoms (80.4%) and cardiovascular symptoms (49.0%). Patients with NSAID-induced anaphylaxis showed a tendency towards respiratory and mucocutaneous manifestations. We found no significant associations between age, sex, or atopy and type of drug. Anaphylaxis recurrence was observed in 25.6% of cases, and the risk was higher when NSAIDs were involved. Conclusions: NSAIDs were the most common cause of anaphylaxis in this study and were also associated with a higher rate of recurrence. We stress the need for better therapeutic management and prevention of recurring episodes of drug-induced anaphylaxis.
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Economics from the NOVA – School of Business and Economics
Resumo:
A retrospective survey done from 1987 till 1990 revealed that 23 patients bitten by pigs sought medical help at a teaching hospital in Uberlândia, in southeastern Brazil. Most cases (21) were from Uberlândia. The cases were evenly distributed by month and by year; most of them (14/16; 87.5%) occurred between 7. OOa.m. and 7.00 p. m. The male to female ratio was 6.7:1. Age ranged from 6 to 73 (mean 38.95 ± SD 22.06, median 36). The bites were more common on the upper limbs, particularly on the forearms. In 11(47.8%) cases the injury was described as deep. In most cases where information was available the injury was related to capture, transport or immobilisation ofthe pigfor slaughter. The following medical procedures were performed: local cleansing in 19(82.6%) cases, rabies vaccine (12; 52.2%), antirabies serum (2; 8.7%), suturing (6; 26.1%) and tetanus vaccine (12; 52.2%). There was no case of infection at the bite site, neither of rabies or tetanus. By our data, the annual incidence of pig bite in Uberlândia can be estimated to be about 1.5/100.000.
Resumo:
Dissertation presented at Faculdade de Ciências e Tecnologia Universidade Nova de Lisboa to obtain a Master Degree in Biomedical Engineering
Resumo:
A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics
Energy-efficient diversity combining for different access schemes in a multi-path dispersive channel
Resumo:
Dissertação para obtenção do Grau de Doutor em Engenharia Electrotécnica e Computadores
Resumo:
The EM3E Master is an Education Programme supported by the European Commission, the European Membrane Society (EMS), the European Membrane House (EMH), and a large international network of industrial companies, research centres and universities
Resumo:
Breast cancer is the most common type of cancer worldwide. The effectiveness of its treatment depends on early stage detection, as well as on the accuracy of its diagnosis. Recently, diagnosis techniques have been submitted to relevant breakthroughs with the upcoming of Magnetic Resonance Imaging, Ultrasound Sonograms and Positron Emission Tomography (PET) scans, among others. The work presented here is focused on studying the application of a PET system to a Positron Emission Mammography (PEM) system. A PET/PEM system works under the principle that a scintillating crystal will detect a gamma-ray pulse, originated at the cancerous cells, converting it into a correspondent visible light pulse. The latter must then be converted into an electrical current pulse by means of a Photo- -Sensitive Device (PSD). After the PSD there must be a Transimpedance Amplifier (TIA) in order to convert the current pulse into a suitable output voltage, in a time period lower than 40 ns. In this Thesis, the PSD considered is a Silicon Photo-Multiplier (SiPM). The usage of this recently developed type of PSD is impracticable with the conventional TIA topologies, as it will be proven. Therefore, the usage of the Regulated Common-Gate (RCG) topology will be studied in the design of the amplifier. There will be also presented two RCG variations, comprising a noise response improvement and differential operation of the circuit. The mentioned topology will also be tested in a Radio-Frequency front-end, showing the versatility of the RCG. A study comprising a low-voltage self-biasing feedback TIA will also be shown. The proposed circuits will be simulated with standard CMOS technology (UMC 130 nm), using a 1.2 V power supply. A power consumption of 0.34 mW with a signal-to-noise ratio of 43 dB was achieved.
Resumo:
Due to the importance and wide applications of the DNA analysis, there is a need to make genetic analysis more available and more affordable. As such, the aim of this PhD thesis is to optimize a colorimetric DNA biosensor based on gold nanoprobes developed in CEMOP by reducing its price and the needed volume of solution without compromising the device sensitivity and reliability, towards the point of care use. Firstly, the price of the biosensor was decreased by replacing the silicon photodetector by a low cost, solution processed TiO2 photodetector. To further reduce the photodetector price, a novel fabrication method was developed: a cost-effective inkjet printing technology that enabled to increase TiO2 surface area. Secondly, the DNA biosensor was optimized by means of microfluidics that offer advantages of miniaturization, much lower sample/reagents consumption, enhanced system performance and functionality by integrating different components. In the developed microfluidic platform, the optical path length was extended by detecting along the channel and the light was transmitted by optical fibres enabling to guide the light very close to the analysed solution. Microfluidic chip of high aspect ratio (~13), smooth and nearly vertical sidewalls was fabricated in PDMS using a SU-8 mould for patterning. The platform coupled to the gold nanoprobe assay enabled detection of Mycobacterium tuberculosis using 3 8l on DNA solution, i.e. 20 times less than in the previous state-of-the-art. Subsequently, the bio-microfluidic platform was optimized in terms of cost, electrical signal processing and sensitivity to colour variation, yielding 160% improvement of colorimetric AuNPs analysis. Planar microlenses were incorporated to converge light into the sample and then to the output fibre core increasing 6 times the signal-to-losses ratio. The optimized platform enabled detection of single nucleotide polymorphism related with obesity risk (FTO) using target DNA concentration below the limit of detection of the conventionally used microplate reader (i.e. 15 ng/μl) with 10 times lower solution volume (3 μl). The combination of the unique optical properties of gold nanoprobes with microfluidic platform resulted in sensitive and accurate sensor for single nucleotide polymorphism detection operating using small volumes of solutions and without the need for substrate functionalization or sophisticated instrumentation. Simultaneously, to enable on chip reagents mixing, a PDMS micromixer was developed and optimized for the highest efficiency, low pressure drop and short mixing length. The optimized device shows 80% of mixing efficiency at Re = 0.1 in 2.5 mm long mixer with the pressure drop of 6 Pa, satisfying requirements for the application in the microfluidic platform for DNA analysis.
Resumo:
Gene therapy presents an ideal strategy for the treatment of genetic as well as acquired diseases, such as cancer and typically involves the insertion of a functioning gene into cells to correct a cellular dysfunction or to provide a new cellular function. Gene delivery vectors are based in two models: viral and non-viral. Viral vectors have high transfection efficiency but their major barrier is immunogenicity. Since the non-viral vectors have no immunogenicity, these have been widely studied. Gold nanoparticles have been proposed as optimal delivery systems of genetic material, due their small size, high surface-to-volume ratio and the ability to be functionalized with multiple molecules. In the present work, an AuNP-based formulation was developed to deliver a plasmid in a colorectal cancer cell line, containing as reporter gene the gene encoding to EGFP. The delivery system resulted from the functionalization of 14 nm AuNP with a PEG layer (4300114 PEG chains/AuNP), which increases stability and biocompatibility of AuNPs; quaternary ammonium groups which provide positive charges that allow electrostatic binding of plasmid, which is considered the therapeutic agent to be transported into cells. The system developed was characterized by UV-vis spectroscopy, DLS, TEM and by electrophoretic mobility, yielding a formulation with 113.5 nm.Transfection efficiency of the formulation developed was evaluated through PCR and through EGFP expression by fluorescence microscopy and fluorescence spectroscopy. The internalization was observed 3h post transfection; however a low level of EGFP expression was achieved. After 24h of incubation, EGFP expression increases just 3 times compared to non-transfected cells. The commercial system (Lipofectamine) expressed EGFP 5 times more than the system developed AuNP@PEG@R4N+@pEGFP. This difference could be related to lower translocation to the nucleus.
Resumo:
A transimpedance amplifier (TIA) is used, in radiation detectors like the positron emission tomography(PET), to transform the current pulse produced by a photo-sensitive device into an output voltage pulse with a desired amplitude and shape. The TIA must have the lowest noise possible to maximize the output. To achieve a low noise, a circuit topology is proposed where an auxiliary path is added to the feedback TIA input, In this auxiliary path a differential transconductance block is used to transform the node voltage in to a current, this current is then converted to a voltage pulse by a second feedback TIA complementary to the first one, with the same amplitude but 180º out of phase with the first feedback TIA. With this circuit the input signal of the TIA appears differential at the output, this is used to try an reduced the circuit noise. The circuit is tested with two different devices, the Avalanche photodiodes (APD) and the Silicon photomultiplier (SIPMs). From the simulations we find that when using s SIPM with Rx=20kΩ and Cx=50fF the signal to noise ratio is increased from 59 when using only one feedback TIA to 68.3 when we use an auxiliary path in conjunction with the feedback TIA. This values where achieved with a total power consumption of 4.82mv. While the signal to noise ratio in the case of the SIPM is increased with some penalty in power consumption.
Resumo:
As the financial crisis hit the Portuguese banks, the profitability of the whole sector squeezed to historical minimums. Reinventing the banking business model in the post-crisis context is an overriding issue to achieve sustainable profits and a low cost-to-income ratio. We propose banks to adopt a true multichannel approach, proceeding to a branch network reformatting and a relocation of services to online channels; adopt a true customer-centric approach and reduce the product and services portfolio complexity; finally, industrialize operations and rationalize the structure. With these measures in place, Portuguese banks will become leaner and more efficient, aspiring to a cost-to-income ratio below 45%.
Resumo:
Double Degree. A Work Project presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics and a Masters Degree in Finance from Louvain School of Management
Resumo:
Ion Mobility Spectrometry coupled with Multi Capillary Columns (MCC -IMS) is a fast analytical technique working at atmospheric pressure with high sensitivity and selectivity making it suitable for the analysis of complex biological matrices. MCC-IMS analysis generates its information through a 3D spectrum with peaks, corresponding to each of the substances detected, providing quantitative and qualitative information. Sometimes peaks of different substances overlap, making the quantification of substances present in the biological matrices a difficult process. In the present work we use peaks of isoprene and acetone as a model for this problem. These two volatile organic compounds (VOCs) that when detected by MCC-IMS produce two overlapping peaks. In this work it’s proposed an algorithm to identify and quantify these two peaks. This algorithm uses image processing techniques to treat the spectra and to detect the position of the peaks, and then fits the data to a custom model in order to separate the peaks. Once the peaks are separated it calculates the contribution of each peak to the data.