886 resultados para labor-wear


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The purpose of this work was to submit the Nitinol files to plasma immersion ion implantation (PIII) and evaluate the effects of the surface treatment. Materials and Methods Wear resistance was determined in vitro by using an equipment for the application of horizontal movements on previously prepared notched plates made of resin. Vickers microhardness was measured in plates and files, before and after surface treatment and the surface chemical composition of the instruments was determined by X-rays photoelectron spectroscopy. Results The hardness values found for the treated Nitinol files were significantly lower than the hardness values measured before the implantation process. The comparison of commercially available instruments shows that the wear resistance of the stainless steel file is higher than the resistance of the Nitinol. Conclusions The results found led to the conclusion that the surface treatment significantly increased the Nitinol files wear resistance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a method of identifying morphological attributes that classify wear particles in relation to the wear process from which they originate and permit the automatic identification without human expertise. The method is based on the use of Multi Layer Perceptron (MLP) for analysis of specific types of microscopic wear particles. The classification of the wear particles was performed according to their morphological attributes of size and aspect ratio, among others. (C) 2010 Journal of Mechanical Engineering. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: A peridural (AP) e a técnica de duplo bloqueio (DB) são utilizadas em analgesia para o trabalho de parto. Este estudo comparou os efeitos na mãe e no feto de ambas as técnicas em analgesia e anestesia para o parto. MÉTODOS: Quarenta parturientes ASA I e II receberam por via peridural 15 ml de ropivacaína a 0,125% (grupo AP) e 5 µg de sufentanil com 2,5 mg bupivacaína por via subaracnóidea (grupo DB). Foram avaliados: intensidade de dor, altura do bloqueio sensitivo, tempo de latência, bloqueio motor, duração da analgesia de parto, tempo para a resolução do parto, hipotensão materna e presença de prurido. Os recém-nascidos foram avaliados pelo índice de Apgar e escore da capacidade adaptativa e neurológica (ECAN), método de Amiel-Tison. RESULTADOS: Não houve diferenças significativas entre os grupos na intensidade da dor, no tempo de latência, no nível do bloqueio sensitivo e no índice de Apgar. O bloqueio motor, a duração da analgesia e o tempo para resolução do parto foram maiores no grupo DB, do qual sete parturientes apresentaram prurido leve. ECAN foi maior no grupo AP após meia hora, duas horas e 24 horas. Noventa e cinco por cento dos recém-nascidos do grupo AP e 60% do grupo DB foram considerados neurologicamente vigorosos ao exame de 24 horas. CONCLUSÃO: As duas técnicas mostraram-se eficazes para analgesia do trabalho de parto. As parturientes do grupo DB apresentaram prurido e trabalho de parto mais prolongado. Recém-nascidos de mães que receberam analgesia de parto via peridural apresentaram melhor ECAN.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXTO E OBJETIVO: A associação entre ropivacaína e clonidina agiria menos que a ropivacaína isolada na mãe e no feto? Foram pesquisados os efeitos materno-fetais de duas técnicas farmacológicas: pequena dose de ropivacaína ou dose menor de ropivacaína mais clonidina na analgesia peridural para parto. TIPO DE ESTUDO E LOCAL: Estudo prospectivo, Departamento de Anestesiologia, Faculdade de Medicina de Botucatu, Universidade Estadual Paulista. MÉTODOS: Trinta e duas parturientes, estado físico de acordo com a American Society of Anesthesiologists I e II, foram aleatoriamente submetidas à analgesia peridural com 15 ml de ropivacaína 0,125% (grupo R) ou 15 ml de ropivacaína 0,0625% mais clonidina, 75 µg (grupo RC). Foram avaliados: intensidade da dor, nível do bloqueio sensitivo, latência, intensidade do bloqueio motor, duração da analgesia de parto e da analgesia peridural. Os neonatos foram avaliados pelo Apgar e método de Amiel-Tison (capacidade neurológica e adaptativa). RESULTADOS: Não houve diferenças significativas entre grupos para dor, nível de bloqueio sensitivo, duração da analgesia peridural e Apgar. Para latência, duração da analgesia de parto e bloqueio motor, grupo R < grupo RC. O escore da capacidade neurológica e adaptativa de meia e duas horas foi maior para o grupo R. Cem por cento dos neonatos do grupo R e 75% dos do grupo RC estavam neurologicamente saudáveis ao exame de 24 horas. CONCLUSÃO: Pequena dose de ropivacaína e dose menor mais clonidina aliviaram a dor materna durante o parto. Neonatos de mães que receberam apenas ropivacaína mostraram melhores escores da capacidade neurológica e adaptativa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study sought to evaluate the effect of repeated implant drilling on the immediate bone-cell viability, and to evaluate drill wear by scanning electron microscopy.Materials and Methods: The tibiae of 10 rabbits were used, divided into 5 groups (G): G1 corresponded to new drills, and G2, G3, G4, and G5 corresponded to drills used 10, 20, 30, and 40 times, respectively. The animals received 10 sequential osteotomies in each tibia. The animals were euthanized immediately after the osteotomies by perfusion with 4% formaldehyde. Samples then underwent immunohistochemistry processing for ordinal qualitative analysis of osteoprotegerin (OPG), the RANK ligant (RANKL; a tumor-related necrosis factor receptor family), and osteocalcin protein immunolabels, as detected by the immunoperoxidase method and revealed with 3,3-diaminobenzidine. Drill wear and plastic deformation were analyzed by scanning electron microscopy (SEM).Results: The proteins were expressed in osteocytes of the superior bone cortical during the 40 drillings. However, in G4 and G5, a discrete increase in the expression of RANKL was observed, when compared with OPG; this increase was statistically significant in G5 (P = .016). The SEM analysis revealed major plastic deformation and drill wear in G4 and G5.Conclusion: Based on the present methodology, it may be concluded that cell viability is preserved if a less traumatic surgical protocol is used. However, the repeated use of drills alters the protein balance as of the thirtieth perforation. (C) 2008 American Association of Oral and Maxillofacial Surgeons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thermal spray WC-based coatings are widely used in the aircraft industry mainly for their resistance to wear, reworking and rebuilding operations and repair of worn components on landing gear, hydraulic cylinders, actuators, propeller hub assemblies, gas turbine engines, and so on. The aircraft industry is also trying to use thermal spray technology to replace electroplating coatings such as hard chromium. In the present work, WC-Co coatings were built up on an AA 7050 aluminum alloy using high velocity oxygen fuel (HVOF) technology and a liquid nitrogen cooling prototype system. The influence of the spray parameters (standard conditions, W19S, increasing the oxygen flux, W19H, and also increasing the carrier gas flux, W19F) on corrosion, friction, and abrasive wear resistance were also studied. The coatings were characterized using optical (OM) and scanning electron (SEM) microscopy, and X-ray diffraction (XRD). The friction and abrasive wear resistance of the coatings were studied using Rubber Wheel and Ball on Disk tests. The electrochemical studies were conducted using open-circuit potential (E(oc)) measurements and electrochemical impedance spectroscopy (EIS). Differences among coated samples were mainly related to the variation of the thermal spray parameters used during the spray process. No significant differences were observed in the wear resistance for the coatings studied, and all of them showed a wear rate around 10 times lower than that of the aluminum alloy. The results of mass loss and wear rate were interpreted considering different mechanisms. Comparing the different spray parameters, the oxygen flux (higher flame temperature) produced the sample which showed the highest corrosion resistance in aerated and unstirred 3.5% NaCl solution. Aluminum ions were detected on the surface almost immediately after the immersion of samples W19S and W19F in chloride solution, showing that the electrolyte reached the substrate and galvanic corrosion probably occurred. For sample W19H, aluminum ions were not detected even after 120 min of immersion in NaCl solution. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)