Resumo

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Processo FAPESP: 05/58363-5

Processo FAPESP: 07/00059-7

The present study evaluated microstructure, microhardness and wear resistance of experimental titanium alloys containing zirconium and tantalum. Alloys were melted in arc melting furnace according to the following compositions: Ti-5Zr, Ti-5Ta and Ti-5Ta-5Zr (%wt). Hemispheres and disks were obtained from wax patterns that were invested and cast by plasma. Microstructures were evaluated using optical microscopy and X-ray diffraction (XRD) analysis and also Vickers microhardness was measured. Hemispherical samples and disks were used for 2-body wear tests, performed by repeated grinding of the samples. Wear resistance was assessed as height loss after 40,000 cycles. The data were compared using ANOVA and post-hoc Tukey test. Ti-5Zr presented a Widmanstatten structure and the identified phases were alpha and alpha' while Ti-5Ta and Ti-5Ta-5Zr presented alpha, beta, alpha' and alpha '' phases, but the former presented a lamellar structure, and the other, acicular. The microhardness of Ti-5Zr was significantly greater than other materials and cp Ti presented wear resistance significantly lower than experimental alloys. It was concluded that wear resistance was improved when adding Ta and Zr to titanium and Zr increased microhardness of Ti-5Zr alloy. (C) 2011 Elsevier Ltd. All rights reserved.

Formato

1873-1879

Identificador

http://dx.doi.org/10.1016/j.jmbbm.2011.06.004

Journal of The Mechanical Behavior of Biomedical Materials. Amsterdam: Elsevier B.V., v. 4, n. 8, p. 1873-1879, 2011.

1751-6161

http://hdl.handle.net/11449/9433

10.1016/j.jmbbm.2011.06.004

WOS:000298764700029

Idioma(s)

eng

Publicador

Elsevier B.V.

Relação

Journal of the Mechanical Behavior of Biomedical Materials

Direitos

closedAccess

Palavras-Chave #Sliding wear #Titanium alloys #Dental applications #Two-body abrasion #Wear testing #Hardness tests
Tipo

info:eu-repo/semantics/article