954 resultados para continuous biometric authentication system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, an Insulin Infusion Advisory System (IIAS) for Type 1 diabetes patients, which use insulin pumps for the Continuous Subcutaneous Insulin Infusion (CSII) is presented. The purpose of the system is to estimate the appropriate insulin infusion rates. The system is based on a Non-Linear Model Predictive Controller (NMPC) which uses a hybrid model. The model comprises a Compartmental Model (CM), which simulates the absorption of the glucose to the blood due to meal intakes, and a Neural Network (NN), which simulates the glucose-insulin kinetics. The NN is a Recurrent NN (RNN) trained with the Real Time Recurrent Learning (RTRL) algorithm. The output of the model consists of short term glucose predictions and provides input to the NMPC, in order for the latter to estimate the optimum insulin infusion rates. For the development and the evaluation of the IIAS, data generated from a Mathematical Model (MM) of a Type 1 diabetes patient have been used. The proposed control strategy is evaluated at multiple meal disturbances, various noise levels and additional time delays. The results indicate that the implemented IIAS is capable of handling multiple meals, which correspond to realistic meal profiles, large noise levels and time delays.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coulometric nanotitrations were realized in a microchannel system using a continuous-flow titration technique with a triangle current-time profile. Redox and acid-base titrations were carried out on Fe(II) and nitric acid samples, respectively, with the same nanotitrator device. A linear relation between the concentration and the coulometric current transferred to the solution was found. The advantages of this universally applicable nanotitrator are fast response, low sample volume, high sensitivity, and high reproducibility as well as the convenience of handling an automated analyzer of the flow-through type.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent outstanding clinical advances with new mechanical circulatory systems have led to additional strategies in the treatment of end-stage heart failure. Heart transplantation can be postponed and for certain patients even replaced by smaller implantable left ventricular assist devices (LVADs). Mechanical support of the failing left ventricle enables appropriate haemodynamic stabilization and recovery of secondary organ failure, often seen in these severely ill patients. These new devices may be of great help to bridge patients until a suitable cardiac allograft is available but are also discussed as definitive treatment for patients who do not qualify for transplantation. Main indications for LVAD implantation are bridge to recovery, bridge to transplantation or destination therapy. An LVAD may be an important tool for patients with an expected prolonged period on the waiting list, for instance those with blood group O or B, with high or low body weight and those with potentially reversible secondary organ failure and pulmonary artery hypertension. However, LVAD implantation means an additional heart operation with inherent perioperative risks and complications during the waiting period. Finally, cardiac transplantation in patients with prior implantation of an LVAD represents a surgical challenge. The care of patients after the implantation of miniaturized LVADs, such as the HeartWare® system, seems to be easier than following pulsatile devices. The explantation of such devices at the time of transplantation is technically more comfortable than after HeartMate II implantation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The intention of an authentication and authorization infrastructure (AAI) is to simplify and unify access to different web resources. With a single login, a user can access web applications at multiple organizations. The Shibboleth authentication and authorization infrastructure is a standards-based, open source software package for web single sign-on (SSO) across or within organizational boundaries. It allows service providers to make fine-grained authorization decisions for individual access of protected online resources. The Shibboleth system is a widely used AAI, but only supports protection of browser-based web resources. We have implemented a Shibboleth AAI extension to protect web services using Simple Object Access Protocol (SOAP). Besides user authentication for browser-based web resources, this extension also provides user and machine authentication for web service-based resources. Although implemented for a Shibboleth AAI, the architecture can be easily adapted to other AAIs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report a case of massive suicidal overdose of meprobamate leading to cardiovascular collapse, respiratory failure, and severe central nervous system depression. We observed first-order elimination kinetics despite significant overdose, and demonstrated effectiveness of continuous venovenous hemodiafiltration (CVVHDF) for extracorporeal removal of meprobamate in this patient. Total body clearance was calculated to be 87 mL/minute, with 64 mL/minute (74%) due to CVVHDF. CVVHDF was stopped after 36 hours, and the patient made an uneventful recovery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The important active and passive role of mineral dust aerosol in the climate and the global carbon cycle over the last glacial/interglacial cycles has been recognized. However, little data on the most important aeolian dust-derived biological micronutrient, iron (Fe), has so far been available from ice-cores from Greenland or Antarctica. Furthermore, Fe deposition reconstructions derived from the palaeoproxies particulate dust and calcium differ significantly from the Fe flux data available. The ability to measure high temporal resolution Fe data in polar ice-cores is crucial for the study of the timing and magnitude of relationships between geochemical events and biological responses in the open ocean. This work adapts an existing flow injection analysis (FIA) methodology for low-level trace Fe determinations with an existing glaciochemical analysis system, continuous flow analysis (CFA) of ice-cores. Fe-induced oxidation of N,N′-dimethyl-p-pheylenediamine (DPD) is used to quantify the biologically more important and easily leachable Fe fraction released in a controlled digestion step at pH ∼1.0. The developed method was successfully applied to the determination of labile Fe in ice-core samples collected from the Antarctic Byrd ice-core and the Greenland Ice-Core Project (GRIP) ice-core.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose. The aim of this research was to evaluate the effect of enteral feeding on tonometric measurement of gastric regional carbon dioxide levels (PrCO2) in normal healthy volunteers. Design and methods. The sample included 12 healthy volunteers recruited by the University Clinical Research Center (UCRC). An air tonometry system monitored PrCO2 levels using a tonometer placed in the lumen of the stomach via orogastric intubation. PrCO2 was automatically measured and recorded every 10 minutes throughout the five hour study period. An oral dose of famotidine 40 mg was self-administered the evening prior to and the morning of the study. Instillation of Isocal® High Nitrogen (HN) was used for enteral feeding in hourly escalating doses of 0, 40, 60, and 80 ml/hr with no feeding during the fifth hour. Results . PrCO2 measurements at time 0 and 10 minutes (41.4 ± 6.5 and 41.8 ± 5.7, respectively) demonstrated biologic precision (Levene's Test statistic = 0.085, p-value 0.774). Biologic precision was lost between T130 and T140 40 when compared to baseline TO (Levene's Test statistic = 1.70, p-value 0.205; and 3.205, p-value 0.042, respectively) and returned to non-significant levels between T270 and T280 (Levene's Test statistic = 3.083, p-value 0.043; and 2.307, p-value 0.143, respectively). Isocal® HN significantly affected the biologic accuracy of PrCO2 measurements (repeated measures ANOVA F 4.91, p-value <0.001). After 20 minutes of enteral feeding at 40 ml/hr, PrCO2 significantly increased (41.4 ± 6.5 to 46.6 ± 4.25, F = 5.4, p-value 0.029). Maximum variance from baseline (41.4 ± 6.5 to 61.3 ± 15.2, F = 17.22, p-value <0.001) was noted after 30 minutes of Isocal® HN at 80 ml/hr or 210 minutes from baseline. The significant elevations in PrCO2 continued throughout the study. Sixty minutes after discontinuation of enteral feeding, PrCO2 remained significantly elevated from baseline (41.4 ± 6.5 to 51.8 ± 9.2, F = 10.15, p-value 0.004). Conclusion. Enteral feeding with Isocal® HN significantly affects the precision and accuracy of PrCO2 measurements in healthy volunteers. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reviews developments in our understanding of the state of the Antarctic and Southern Ocean climate and its relation to the global climate system over the last few millennia. Climate over this and earlier periods has not been stable, as evidenced by the occurrence of abrupt changes in atmospheric circulation and temperature recorded in Antarctic ice core proxies for past climate. Two of the most prominent abrupt climate change events are characterized by intensification of the circumpolar westerlies (also known as the Southern Annular Mode) between similar to 6000 and 5000 years ago and since 1200-1000 years ago. Following the last of these is a period of major trans-Antarctic reorganization of atmospheric circulation and temperature between A. D. 1700 and 1850. The two earlier Antarctic abrupt climate change events appear linked to but predate by several centuries even more abrupt climate change in the North Atlantic, and the end of the more recent event is coincident with reorganization of atmospheric circulation in the North Pacific. Improved understanding of such events and of the associations between abrupt climate change events recorded in both hemispheres is critical to predicting the impact and timing of future abrupt climate change events potentially forced by anthropogenic changes in greenhouse gases and aerosols. Special attention is given to the climate of the past 200 years, which was recorded by a network of recently available shallow firn cores, and to that of the past 50 years, which was monitored by the continuous instrumental record. Significant regional climate changes have taken place in the Antarctic during the past 50 years. Atmospheric temperatures have increased markedly over the Antarctic Peninsula, linked to nearby ocean warming and intensification of the circumpolar westerlies. Glaciers are retreating on the peninsula, in Patagonia, on the sub-Antarctic islands, and in West Antarctica adjacent to the peninsula. The penetration of marine air masses has become more pronounced over parts of West Antarctica. Above the surface, the Antarctic troposphere has warmed during winter while the stratosphere has cooled year-round. The upper kilometer of the circumpolar Southern Ocean has warmed, Antarctic Bottom Water across a wide sector off East Antarctica has freshened, and the densest bottom water in the Weddell Sea has warmed. In contrast to these regional climate changes, over most of Antarctica, near-surface temperature and snowfall have not increased significantly during at least the past 50 years, and proxy data suggest that the atmospheric circulation over the interior has remained in a similar state for at least the past 200 years. Furthermore, the total sea ice cover around Antarctica has exhibited no significant overall change since reliable satellite monitoring began in the late 1970s, despite large but compensating regional changes. The inhomogeneity of Antarctic climate in space and time implies that recent Antarctic climate changes are due on the one hand to a combination of strong multidecadal variability and anthropogenic effects and, as demonstrated by the paleoclimate record, on the other hand to multidecadal to millennial scale and longer natural variability forced through changes in orbital insolation, greenhouse gases, solar variability, ice dynamics, and aerosols. Model projections suggest that over the 21st century the Antarctic interior will warm by 3.4 degrees +/- 1 degrees C, and sea ice extent will decrease by similar to 30%. Ice sheet models are not yet adequate enough to answer pressing questins about the effect of projected warming on mass balance and sea level. Considering the potentially major impacts of a warming climate on Antarctica, vigorous efforts are needed to better understand all aspects of the highly coupled Antarctic climate system as well as its influence on the Earth's climate and oceans.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A float-stopper mechanism was designed to drain fish holding tanks directly from the bottom. Unlike traditional, top-drawn standpipe systems, it allows continuous flushing of settled solid waste. It also prevents the accumulation of these wastes between the two standpipes that are used in bottom-drawn, double-walled standpipe systems. When suspended solids are forced upward between the outer and inner standpipes of such systems, a minimum velocity must be maintained to prevent sediment accumulation. This minimum velocity determines the minimum flow rate through the tank. The system described in this report flushes well over a wide range of flow rates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND No reliable tool to predict outcome of acute kidney injury (AKI) exists. HYPOTHESIS A statistically derived scoring system can accurately predict outcome in dogs with AKI managed with hemodialysis. ANIMALS One hundred and eighty-two client-owned dogs with AKI. METHODS Logistic regression analyses were performed initially on clinical variables available on the 1st day of hospitalization for relevance to outcome. Variables with P< or = .1 were considered for further analyses. Continuous variables outside the reference range were divided into quartiles to yield quartile-specific odds ratios (ORs) for survival. Models were developed by incorporating weighting factors assigned to each quartile based on the OR, using either the integer value of the OR (Model A) or the exact OR (Models B or C, when the etiology was known). A predictive score for each model was calculated for each dog by summing all weighting factors. In Model D, actual values for continuous variables were used in a logistic regression model. Receiver-operating curve analyses were performed to assess sensitivities, specificities, and optimal cutoff points for all models. RESULTS Higher scores were associated with decreased probability of survival (P < .001). Models A, B, C, and D correctly classified outcomes in 81, 83, 87, and 76% of cases, respectively, and optimal sensitivities/specificities were 77/85, 81/85, 83/90 and 92/61%, respectively. CONCLUSIONS AND CLINICAL RELEVANCE The models allowed outcome prediction that corresponded with actual outcome in our cohort. However, each model should be validated further in independent cohorts. The models may also be useful to assess AKI severity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES Left ventricular assist devices are an important treatment option for patients with heart failure alter the hemodynamics in the heart and great vessels. Because in vivo magnetic resonance studies of patients with ventricular assist devices are not possible, in vitro models represent an important tool to investigate flow alterations caused by these systems. By using an in vitro magnetic resonance-compatible model that mimics physiologic conditions as close as possible, this work investigated the flow characteristics using 4-dimensional flow-sensitive magnetic resonance imaging of a left ventricular assist device with outflow via the right subclavian artery as commonly used in cardiothoracic surgery in the recent past. METHODS An in vitro model was developed consisting of an aorta with its supra-aortic branches connected to a left ventricular assist device simulating the pulsatile flow of the native failing heart. A second left ventricular assist device supplied the aorta with continuous flow via the right subclavian artery. Four-dimensional flow-sensitive magnetic resonance imaging was performed for different flow rates of the left ventricular assist device simulating the native heart and the left ventricular assist device providing the continuous flow. Flow characteristics were qualitatively and quantitatively evaluated in the entire vessel system. RESULTS Flow characteristics inside the aorta and its upper branching vessels revealed that the right subclavian artery and the right carotid artery were solely supported by the continuous-flow left ventricular assist device for all flow rates. The flow rates in the brain-supplying arteries are only marginally affected by different operating conditions. The qualitative analysis revealed only minor effects on the flow characteristics, such as weakly pronounced vortex flow caused by the retrograde flow via the brachiocephalic artery. CONCLUSIONS The results indicate that, despite the massive alterations in natural hemodynamics due to the retrograde flow via the right subclavian and brachiocephalic arteries, there are no drastic consequences on the flow in the brain-feeding arteries and the flow characteristics in the ascending and descending aortas. It may be beneficial to adjust the operating condition of the left ventricular assist device to the residual function of the failing heart.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM Depending on intensity, exercise may induce a strong hormonal and metabolic response, including acid-base imbalances and changes in microcirculation, potentially interfering with the accuracy of continuous glucose monitoring (CGM). The present study aimed at comparing the accuracy of the Dexcom G4 Platinum (DG4P) CGM during continuous moderate and intermittent high-intensity exercise (IHE) in adults with type 1 diabetes (T1DM). METHODS Ten male individuals with well-controlled T1DM (HbA1c 7.0±0.6% [54±6mmol/mol]) inserted the DG4P sensor 2 days prior to a 90min cycling session (50% VO2peak) either with (IHE) or without (CONT) a 10s all-out sprint every 10min. Venous blood samples for reference glucose measurement were drawn every 10min and euglycemia (target 7mmol/l) was maintained using an oral glucose solution. Additionally, lactate and venous blood gas variables were determined. RESULTS Mean reference blood glucose was 7.6±0.2mmol/l during IHE and 6.7±0.2mmol/l during CONT (p<0.001). IHE resulted in significantly higher levels of lactate (7.3±0.5mmol/l vs. 2.6±0.3mmol/l, p<0.001), while pH values were significantly lower in the IHE group (7.27 vs. 7.38, p=0.001). Mean absolute relative difference (MARD) was 13.3±2.2% for IHE and 13.6±2.8% for CONT suggesting comparable accuracy (p=0.90). Using Clarke Error Grid Analysis, 100% of CGM values during both IHE and CONT were in zones A and B (IHE: 77% and 23%; CONT: 78% and 22%). CONCLUSIONS The present study revealed good and comparable accuracy of the DG4P CGM system during intermittent high intensity and continuous moderate intensity exercise, despite marked differences in metabolic conditions. This corroborates the clinical robustness of CGM under differing exercise conditions. CLINICAL TRIAL REGISTRATION NUMBER ClinicalTrials.gov NCT02068638.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Despite important advances in psychological and pharmacological treatments of persistent depressive disorders in the past decades, their responses remain typically slow and poor, and differential responses among different modalities of treatments or their combinations are not well understood. Cognitive-Behavioural Analysis System of Psychotherapy (CBASP) is the only psychotherapy that has been specifically designed for chronic depression and has been examined in an increasing number of trials against medications, alone or in combination. When several treatment alternatives are available for a certain condition, network meta-analysis (NMA) provides a powerful tool to examine their relative efficacy by combining all direct and indirect comparisons. Individual participant data (IPD) meta-analysis enables exploration of impacts of individual characteristics that lead to a differentiated approach matching treatments to specific subgroups of patients. METHODS AND ANALYSIS We will search for all randomised controlled trials that compared CBASP, pharmacotherapy or their combination, in the treatment of patients with persistent depressive disorder, in Cochrane CENTRAL, PUBMED, SCOPUS and PsycINFO, supplemented by personal contacts. Individual participant data will be sought from the principal investigators of all the identified trials. Our primary outcomes are depression severity as measured on a continuous observer-rated scale for depression, and dropouts for any reason as a proxy measure of overall treatment acceptability. We will conduct a one-step IPD-NMA to compare CBASP, medications and their combinations, and also carry out a meta-regression to identify their prognostic factors and effect moderators. The model will be fitted in OpenBUGS, using vague priors for all location parameters. For the heterogeneity we will use a half-normal prior on the SD. ETHICS AND DISSEMINATION This study requires no ethical approval. We will publish the findings in a peer-reviewed journal. The study results will contribute to more finely differentiated therapeutics for patients suffering from this chronically disabling disorder. TRIAL REGISTRATION NUMBER CRD42016035886.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study focuses on the impact of a clinic-based intervention program on the immunization status of limited-income urban children. The intervention program consisted of an information session for clinic health care providers and the placement of individualized immunization information labels on clinic notes at the time of each visit. The degree of impact of the intervention on immunization administration was ascertained through a comparison of two similar groups of infants born in the same months of the year immediately before (N = 201) and after (N = 203) the information session and initiation of the labeling system. The timeliness of administration of each diphtheria, pertussis, tetanus and trivalent oral polio vaccine (DPT/TOPV) in the first year series of three was compared pre- to postintervention. Significantly more third immunizations were given the postintervention subjects within ten days of the recommended time of application ( p = .0361). Life table analysis indicated that the probability of an infant's passing one year of age without the administration of the third immunization decreased for postintervention infants (p = .0515). The intervention was most successful in assuring administration of the series of immunizations in those infants who were seen by the health care provider for at least 50% of their first year visits. Results indicate that minor changes in the format of information given a relatively continuous provider can increase completion of immunization series in infants. ^