694 resultados para VALVES


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The purpose of this study is to delineate changes in aortic geometry and diameter due to dissection. BACKGROUND Aortic diameter is the major criterion for elective ascending aortic replacement for dilated ascending aortas to prevent aortic dissection. However, recommendations are made on the basis of clinical experience and observation of diameters of previously dissected aortas. METHODS Six tertiary centers on 2 continents reviewed their acute aortic dissection type A databases, which contained 1,821 patients. Included were all non-Marfan patients with nonbicuspid aortic valves who had undergone computed tomography angiography <2 years before and within 12 h after aortic dissection onset. Aortic geometry before and after dissection onset were compared. RESULTS Altogether, 63 patients were included (27 spontaneous and 36 retrograde dissections, median age 68 [57; 77] years; 54% were men). In all but 1 patient, maximum ascending aortic diameter was <55 mm before aortic dissection onset. The largest increase in diameter and volume induced by the dissection were observed in the ascending aorta (40.1 [36.6; 45.3] mm vs. 52.9 [46.1; 58.6] mm, +12.8 mm; p < 0.001; 124.0 [90.8; 162.5] cm(3) vs. 171.0 [147.0; 197.0] cm(3), +47 cm(3); p < 0.001). Mean aortic arch diameter increased from 39.8 (30.5; 42.6) mm to 46.4 (42.0; 51.6) mm (+6.6 mm; p < 0.001) and descending thoracic aorta diameter from 31.2 (27.0; 33.3) mm to 34.9 (30.9; 39.5) mm (+3.7 mm; p < 0.001). Changes in thoracic aorta geometry were similar for spontaneous and retrograde etiology. CONCLUSIONS Geometry of the thoracic aorta is affected by aortic dissection, leading to an increase in diameter that is most pronounced in the ascending aorta. Both spontaneous and retrograde dissection result in similar aortic geometry changes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Numerous designs of bioprosthetic valves exist. The sutureless surgical valve is a newer design concept which combines elements of the transcatheter valve technology with surgical valves. This design aims at shorter and easier implantation. It was the aim of this study to perform hemodynamic and kinematic measurements for this type of valves to serve as a baseline for following studies which investigate the effect of the aortic root on the valve performance. To this end, the Edwards Intuity aortic valve was investigated in a new in vitro flow loop mimicking the left heart. The valve was implanted in a transparent, compliant aortic root model, and the valve kinematics was investigated using a high speed camera together with synchronized hemodynamic measurements of pressures and flows. The valve closure was asynchronous (one by one leaflet), and the valve started to close before the deceleration of the fluid. The aortic root model showed a dilation of the sinuses which was different to the ascending aorta, and the annulus was found to move towards the left ventricle during diastole and towards the aorta during systole.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Immersed boundary simulations have been under development for physiological flows, allowing for elegant handling of fluid-structure interaction modelling with large deformations due to retained domain-specific meshing. We couple a structural system in Lagrangian representation that is formulated in a weak form with a Navier-Stokes system discretized through a finite differences scheme. We build upon a proven highly scalable imcompressible flow solver that we extend to handle FSI. We aim at applying our method to investigating the hemodynamics of Aortic Valves. The code is going to be extended to conform to the new hybrid-node supercomputers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Sutureless aortic valve replacement (SU-AVR) has emerged as an innovative alternative for treatment of aortic stenosis. By avoiding the placement of sutures, this approach aims to reduce cross-clamp and cardiopulmonary bypass (CPB) duration and thereby improve surgical outcomes and facilitate a minimally invasive approach suitable for higher risk patients. The present systematic review and meta-analysis aims to assess the safety and efficacy of SU-AVR approach in the current literature. METHODS Electronic searches were performed using six databases from their inception to January 2014. Relevant studies utilizing sutureless valves for aortic valve implantation were identified. Data were extracted and analyzed according to predefined clinical endpoints. RESULTS Twelve studies were identified for inclusion of qualitative and quantitative analyses, all of which were observational reports. The minimally invasive approach was used in 40.4% of included patients, while 22.8% underwent concomitant coronary bypass surgery. Pooled cross-clamp and CPB duration for isolated AVR was 56.7 and 46.5 minutes, respectively. Pooled 30-day and 1-year mortality rates were 2.1% and 4.9%, respectively, while the incidences of strokes (1.5%), valve degenerations (0.4%) and paravalvular leaks (PVL) (3.0%) were acceptable. CONCLUSIONS The evaluation of current observational evidence suggests that sutureless aortic valve implantation is a safe procedure associated with shorter cross-clamp and CPB duration, and comparable complication rates to the conventional approach in the short-term.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aortic valve replacement (AVR) is the most frequently performed procedure in valve surgery. The controversy about the optimal choice of the prosthetic valve is as old as the technique itself. Currently there is no perfect valve substitute available. The main challenge is to choose between mechanical and biological prosthetic valves. Biological valves include pericardial (bovine, porcine or equine) and native porcine bioprostheses designed in stented or stentless versions. Homografts and pulmonary autografts are reserved for special indications and will not be discussed in detail in this review. We will focus on the decision making between artificial biological and mechanical prostheses, respectively. The first part of this article reviews guideline recommendations concerning the choice of aortic prostheses in different clinical situations while the second part is focused on novel strategies in the treatment of patients with aortic valve pathology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES This report summarizes the 5-year clinical and haemodynamic data from three prospective, European multicentre trials with the Perceval sutureless aortic valve. METHODS From April 2007 to August 2012, 731 consecutive patients (mean age: 78.5 years; 68.1% females; mean logistic EuroSCORE 10.9%) underwent AVR with the Perceval valve in 25 European centres. Isolated AVR was performed in 498 (68.1%) patients. A minimally invasive approach was performed in 189 (25.9%) cases. The cumulative follow-up was 729 patients-years. RESULTS In isolated AVR, mean cross-clamp and cardiopulmonary bypass times were 30.8 and 50.8 min in full sternotomy, and 37.6 and 64.4 min in the minimally invasive approach, respectively. Early cardiac-related deaths occurred in 1.9%. Overall survival rates at 1 and 5 years were 92.1 and 74.7%, respectively. Major paravalvular leak occurred in 1.4% and 1% at early and late follow-up, respectively. Significant improvement in clinical status was observed postoperatively in the majority of patients. Mean and peak gradients decreased from 42.9 and 74.0 mmHg preoperatively, to 7.8 and 16 mmHg at the 3-year follow-up. LV mass decreased from 254.5 to 177.4 g at 3 years. CONCLUSIONS This European multicentre experience, with the largest cohort of patients with sutureless valves to date, shows excellent clinical and haemodynamic results that remain stable even up to the 5-year follow-up. Even in this elderly patient cohort with 40% octogenarians, both early and late mortality rates were very low. There were no valve migrations, structural valve degeneration or valve thrombosis in the follow-up. The sutureless technique is a promising alternative to biological aortic valve replacement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter mitral interventions has been developed to address an unmet clinical need and may be an alternative therapeutic option to surgery with the intent to provide symptomatic and prognostic benefit. Beyond MitraClip therapy, alternative repair technologies are being developed to expand the transcatheter intervention armamentarium. Recently, the feasibility of transcatheter mitral valve implantation in native non-calcified valves has been reported in very high-risk patients. Acknowledging the lack of scientific evidence to date, it is difficult to predict what the ultimate future role of transcatheter mitral valve interventions will be. The purpose of the present report is to review the current state-of-the-art of mitral valve intervention, and to identify the potential future scenarios, which might benefit most from the transcatheter repair and replacement devices under development.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

GOAL We present the development of a boneanchored port for the painless long-term hemodialytic treatment of patients with renal failure. This port is implanted behind the ear. METHODS The port was developed based on knowledge obtained from long-term experience with implantable hearing devices, which are firmly anchored to the bone behind the ear. This concept of bone anchoring was adapted to the requirements for a vascular access during hemodialysis. The investigational device is comprised of a base plate that is firmly fixed with bone screws to the bone behind the ear (temporal bone). A catheter leads from the base plate valve block through the internal jugular vein and into the right atrium. The valves are opened using a special disposable adapter, without any need to puncture the blood vessels. Between hemodialysis sessions the port is protected with a disposable cover. RESULTS Flow rate, leak tightness and purification were tested on mockups. Preoperative planning and the surgical procedure were verified in 15 anatomical human whole head specimens. CONCLUSION Preclinical evaluations demonstrated the technical feasibility and safety of the investigational device. SIGNIFICANCE Approximately 1.5 million people are treated with hemodialysis worldwide, and 25% of the overall cost of dialysis therapy results from vascular access problems. New approaches towards enhancing vascular access could potentially reduce the costs and complications of hemodialytic therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biomechanical forces, such as fluid shear stress, govern multiple aspects of endothelial cell biology. In blood vessels, disturbed flow is associated with vascular diseases, such as atherosclerosis, and promotes endothelial cell proliferation and apoptosis. Here, we identified an important role for disturbed flow in lymphatic vessels, in which it cooperates with the transcription factor FOXC2 to ensure lifelong stability of the lymphatic vasculature. In cultured lymphatic endothelial cells, FOXC2 inactivation conferred abnormal shear stress sensing, promoting junction disassembly and entry into the cell cycle. Loss of FOXC2-dependent quiescence was mediated by the Hippo pathway transcriptional coactivator TAZ and, ultimately, led to cell death. In murine models, inducible deletion of Foxc2 within the lymphatic vasculature led to cell-cell junction defects, regression of valves, and focal vascular lumen collapse, which triggered generalized lymphatic vascular dysfunction and lethality. Together, our work describes a fundamental mechanism by which FOXC2 and oscillatory shear stress maintain lymphatic endothelial cell quiescence through intercellular junction and cytoskeleton stabilization and provides an essential link between biomechanical forces and endothelial cell identity that is necessary for postnatal vessel homeostasis. As FOXC2 is mutated in lymphedema-distichiasis syndrome, our data also underscore the role of impaired mechanotransduction in the pathology of this hereditary human disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulmonary emphysema causes decrease in lung function due to irreversible dilatation of intrapulmonary air spaces, which is linked to high morbidity and mortality. Lung volume reduction (LVR) is an invasive therapeutical option for pulmonary emphysema in order to improve ventilation mechanics. LVR can be carried out by lung resection surgery or different minimally invasive endoscopical procedures. All LVR-options require mandatory preinterventional evaluation to detect hyperinflated dysfunctional lung areas as target structures for treatment. Quantitative computed tomography can determine the volume percentage of emphysematous lung and its topographical distribution based on the lung's radiodensity. Modern techniques allow for lobebased quantification that facilitates treatment planning. Clinical tests still play the most important role in post-interventional therapy monitoring, but CT is crucial in the detection of postoperative complications and foreshadows the method's high potential in sophisticated experimental studies. Within the last ten years, LVR with endobronchial valves has become an extensively researched minimally-invasive treatment option. However, this therapy is considerably complicated by the frequent occurrence of functional interlobar shunts. The presence of "collateral ventilation" has to be ruled out prior to valve implantations, as the presence of these extraanatomical connections between different lobes may jeopardize the success of therapy. Recent experimental studies evaluated the automatic detection of incomplete lobar fissures from CT scans, because they are considered to be a predictor for the existence of shunts. To date, these methods are yet to show acceptable results. KEY POINTS Today, surgical and various minimal invasive methods of lung volume reduction are in use. Radiological and nuclear medical examinations are helpful in the evaluation of an appropriate lung area. Imaging can detect periinterventional complications. Reduction of lung volume has not yet been conclusively proven to be effective and is a therapeutical option with little scientific evidence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Endoscopic lung volume reduction (ELVR) with valves has been shown to improve COPD patients with severe emphysema. However, a major complication is pneumothoraces, occurring typically soon after valve implantation, with severe consequences if not managed promptly. Based on the knowledge that strain activity is related to a higher risk of pneumothoraces, we asked whether modifying post-operative medical care with the inclusion of strict short-term limitation of strain activity is associated with a lower incidence of pneumothorax. METHODS Seventy-two (72) emphysematous patients without collateral ventilation were treated with bronchial valves and included in the study. Thirty-two (32) patients received standard post-implantation medical management (Standard Medical Care (SMC)), and 40 patients received a modified medical care that included an additional bed rest for 48 hours and cough suppression, as needed (Modified Medical Care (MMC)). RESULTS The baseline characteristics were similar for the two groups, except there were more males in the SMC cohort. Overall, ten pneumothoraces occurred up to four days after ELVR, eight pneumothoraces in the SMC, and only two in the MMC cohorts (p=0.02). Complicated pneumothoraces and pneumothoraces after upper lobe treatment were significantly lower in MMC (p=0.02). Major clinical outcomes showed no significant differences between the two cohorts. CONCLUSIONS In conclusion, modifying post-operative medical care to include bed rest for 48 hours after ELVR and cough suppression, if needed, might reduce the incidence of pneumothoraces. Prospective randomized studies with larger numbers of well-matched patients are needed to confirm the data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE The aim of this study was to evaluate the utility of cardiac postmortem magnetic resonance (PMMR) to perform routine measurements of the ventricular wall thicknesses and the heart valves and to assess if imaging measurements are consistent with traditional autopsy measurements. METHODS In this retrospective study, 25 cases with cardiac PMMR and subsequent autopsy were included. The thicknesses of the myocardial walls as well as the circumferences of all heart valves were measured on cardiac PMMR and compared to autopsy measurements. Paired samples T-test and the Wilcoxon-Signed rank test, were used to compare autopsy and cardiac PMMR measurements. For exploring correlations, the Pearson's Correlation coefficient and the Spearman's Rho test were used. RESULTS Cardiac PMMR measurements of the aortic and pulmonary valve circumferences showed no significant differences from autopsy measurements. The mitral and tricuspid valves circumferences differed significantly from autopsy measurements. Left myocardial and right myocardial wall thickness also differed significantly from autopsy measurements. Left and right myocardial wall thickness, and tricuspid valve circumference measurements on cardiac PMMR and autopsy, correlated strongly and significantly. CONCLUSION Several PMMR measurements of cardiac parameters differ significantly from corresponding autopsy measurements. However, there is a strong correlation between cardiac PMMR measurements and autopsy measurements in the majority of these parameters. It is important to note that myocardial walls are thicker when measured in situ on cardiac PMMR than when measured at autopsy. Investigators using post-mortem MR should be aware of these differences in order to avoid false diagnoses of cardiac pathology based on cardiac PMMR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

1. The morphologically complex taxon Cyclotella comensis Grunow had no clear relationship with environmental parameters in a study using sediment surface samples from the Swiss Alps. The morphological heterogeneity of the taxon was investigated by applying a principal component analysis (PCA) to 9000 presence/absence descriptions of valves from surface samples of six lakes from different altitudes (15 characteristics, 100 valves each lake). The PCA allowed the classification of six morphs, which differed mainly in size and length of striae. Photographs of the morphs are shown in this paper. 2. Sixty-eight sediment surface samples were analysed using these newly defined six morphs. Summer temperature explained a major part of the variance between the morphs as assessed by a redundancy analysis (RDA). Summer temperature optima and tolerances were estimated using weighted averaging. 3. The influence of the revised C. comensis taxonomy on the diatom inferred summer temperature of a high alpine lake is discussed in a multiproxy context for the past 800 years.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The pattern of expression of the pro$\alpha$2(I) collagen gene is highly tissue-specific in adult mice and shows its strongest expression in bones, tendons, and skin. Transgenic mice were generated harboring promoter fragments of the mouse pro$\alpha$2(I) collagen gene linked to the Escherichia coli $\beta$-galactosidase or firefly luciferase genes to examine the activity of these promoters during development. A region of the mouse pro$\alpha$2(I) collagen promoter between $-$2000 and +54 exhibited a pattern of $\beta$-galactosidase activity during embryonic development that corresponded to the expression pattern of the endogenous pro$\alpha$2(I) collagen gene as determined by in situ hybridization. A similar pattern of activity was also observed with much smaller promoter fragments containing either 500 or 350 bp of upstream sequence relative to the start of transcription. Embryonic regions expressing high levels of $\beta$-galactosidase activity included the valves of the developing heart, sclerotomes, meninges, limb buds, connective tissue fascia between muscle fibers, osteoblasts, tendon, periosteum, dermis, and peritoneal membranes. The pattern of $\beta$-galactosidase activity was similar to the extracellular immunohistochemical localization of transforming growth factor-$\beta$1 (TGF-$\beta$1). The $-$315 to $-$284 region of the pro$\alpha$2(I) collagen promoter was previously shown to mediate the stimulatory effects of TGF-$\beta$1 on the pro$\alpha$2(I) collagen promoter in DNA transfection experiments with cultured fibroblasts. A construct containing this sequence tandemly repeated 5$\sp\prime$ to both a very short $\alpha$2(I) collagen promoter ($-$40 to +54) and a heterologous minimal promoter showed preferential activity in tail and skin of 4-week old transgenic mice. The pattern of expression mimics that of the $-$350 to +54 pro$\alpha$2(I) collagen promoter linked to a luciferase reporter gene in transgenic mice. ^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A total of eighteen species of marine ostracods, in at least twelve genera, have been recovered from Early and Late Oligocene glacio-marine sediments from boreholes CRP-3 and CRP-2/2A in the Victoria Land Basin, Ross Sea, Antarctica. Faunas are sparse and generally moderately-well preserved. Previously, three species or closely related species have been recorded only from glacial settings (Kuiperiana meridionalislain (Müller), Australicythere polylyca (Müller), Hemicytheridea aff. H. kinggeorgeensis Blaszyk), but palaeotemperatures somewhat higher than at present in the Ross Sea are suggested by the presence of Austrocythere reticulotuberculata Hartmann, Cluthia aff. C. antiqua Ayress & Drapala and Cytherella? sp. 4796. Majungaella sp. 4471 is an enigmatic component, representing a genus previously known only from warm Cretaceous and Eocene, and relatively warm interglacial Pliocene habitats in southern Gondwana and the Antarctic Peninsula. Palaeobiogeographical considerations indicate that during Early Oligocene times, the Ross Sea area had faunal links with both Antarctic Peninsula/South America and southern Australasia. Three species present in the Early Oligocene glacial environments at Cape Roberts have survived to the Recent in the cool-cold Antarctic/Sub-Antarctic region: Austrocythere reticulotuberculata Hartmann, Australicythere polylyca (Müller), and Kuiperiana meridionalis (Müller).