Novel bone-anchored vascular access on the mastoid for hemodialysis: concept and preclinical trials


Autoria(s): Stieger, Christof; Arnold, Andreas Michael; Kruse, Anja; Wiedmer, Simona; Widmer, Matthias; Guignard, Jérémie; Schutz, Daniel; Guenat, Jean-Marc; Bachtler, Matthias; Caversaccio, Marco; Uehlinger, Dominik; Frey, Felix; Häusler, Rudolf
Data(s)

18/09/2015

Resumo

GOAL We present the development of a boneanchored port for the painless long-term hemodialytic treatment of patients with renal failure. This port is implanted behind the ear. METHODS The port was developed based on knowledge obtained from long-term experience with implantable hearing devices, which are firmly anchored to the bone behind the ear. This concept of bone anchoring was adapted to the requirements for a vascular access during hemodialysis. The investigational device is comprised of a base plate that is firmly fixed with bone screws to the bone behind the ear (temporal bone). A catheter leads from the base plate valve block through the internal jugular vein and into the right atrium. The valves are opened using a special disposable adapter, without any need to puncture the blood vessels. Between hemodialysis sessions the port is protected with a disposable cover. RESULTS Flow rate, leak tightness and purification were tested on mockups. Preoperative planning and the surgical procedure were verified in 15 anatomical human whole head specimens. CONCLUSION Preclinical evaluations demonstrated the technical feasibility and safety of the investigational device. SIGNIFICANCE Approximately 1.5 million people are treated with hemodialysis worldwide, and 25% of the overall cost of dialysis therapy results from vascular access problems. New approaches towards enhancing vascular access could potentially reduce the costs and complications of hemodialytic therapy.

Formato

application/pdf

Identificador

http://boris.unibe.ch/76299/1/07272057.pdf

Stieger, Christof; Arnold, Andreas Michael; Kruse, Anja; Wiedmer, Simona; Widmer, Matthias; Guignard, Jérémie; Schutz, Daniel; Guenat, Jean-Marc; Bachtler, Matthias; Caversaccio, Marco; Uehlinger, Dominik; Frey, Felix; Häusler, Rudolf (2015). Novel bone-anchored vascular access on the mastoid for hemodialysis: concept and preclinical trials. IEEE transactions on bio-medical engineering, 63(5), pp. 984-990. Institute of Electrical and Electronics Engineers 10.1109/TBME.2015.2480241 <http://dx.doi.org/10.1109/TBME.2015.2480241>

doi:10.7892/boris.76299

info:doi:10.1109/TBME.2015.2480241

info:pmid:26394413

urn:issn:1558-2531

Idioma(s)

eng

Publicador

Institute of Electrical and Electronics Engineers

Relação

http://boris.unibe.ch/76299/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Stieger, Christof; Arnold, Andreas Michael; Kruse, Anja; Wiedmer, Simona; Widmer, Matthias; Guignard, Jérémie; Schutz, Daniel; Guenat, Jean-Marc; Bachtler, Matthias; Caversaccio, Marco; Uehlinger, Dominik; Frey, Felix; Häusler, Rudolf (2015). Novel bone-anchored vascular access on the mastoid for hemodialysis: concept and preclinical trials. IEEE transactions on bio-medical engineering, 63(5), pp. 984-990. Institute of Electrical and Electronics Engineers 10.1109/TBME.2015.2480241 <http://dx.doi.org/10.1109/TBME.2015.2480241>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed