561 resultados para Specialty coffees
Resumo:
Purpose – The objective of the present research is to examine the relationship between consumers' satisfaction with a retailer and the equity they associate with the retail brand. Design/methodology/approach – Retail brand equity is conceptualized as a four-dimensional construct comprising: retailer awareness, retailer associations, retailer perceived quality, and retailer loyalty. Then the associative network memory model is applied from cognitive psychology to the specific context of the relationships between customer satisfaction and consumer-based retailer equity. A survey was undertaken using a convenience sample of shopping mall consumers in an Australian state capital city. The questionnaire used to collect data included an experimental design such that two categories of retailers were included in the study: department stores and specialty stores, with three retailers representing each category. The relationship between consumer-based retailer equity and customer satisfaction was examined using multivariate analysis of variance. Findings – Results indicate that retail brand equity varies with customer satisfaction. For department stores, each consumer-based retailer equity dimension varied according to customer satisfaction with the retailer. However, for specialty stores, only three of the consumer-based retailer equity dimensions, namely retailer awareness, retailer associations and retailer perceived quality, varied according to customer satisfaction level with the retailer. Originality/value – The principal contribution of the present research is that it demonstrates empirically a positive relationship between customer satisfaction and an intangible asset such as retailer equity.
Resumo:
Este estudo aborda as matérias edificantes do Jornal Nacional e a maneira como elas são compreendidas pelos grupos de jovens selecionados para esta pesquisa. O objetivo é avaliar se há diferença na percepção das informações dessas matérias por jovens de diferentes estratos sociais e culturais, pretende-se também, verificar se esses jovens percebem nas matérias edificantes algum tipo de ação cidadã. Este estudo se torna relevante visto que as transformações no processo de informação nos meios de comunicação de massa têm proporcionado grande velocidade na transmissão das mensagens. Sendo assim, alguns autores acreditam que o surgimento das novas tecnologias faz com que as pessoas sejam influenciadas por várias mídias, simultaneamente. Nesse sentido, o público jovem é um segmento importante dentro do universo dos receptores. É na juventude que o indivíduo tem sua formação aprimorada pelos meios que cumprem esse papel formador, como a escola, os pais e os meios de comunicação, cada um interagindo de acordo com a sua especificidade. Utilizando a discussão em grupo com alunos do Ensino Médio de uma escola pública e uma particular, foi possível ter a visão de como a amostra selecionada assimila a temática.(AU)
Resumo:
O presente estudo realiza uma análise dos conflitos entre profissionais especialistas na organização escolar especial privada, segundo a percepção e análise dos registros da pesquisadora como docente e coordenadora na área de Educação Especial. Há algum tempo, a organização escolar especial é composta de diversos especialistas para atender às necessidades dos seus alunos. Tais profissionais possuem formações e desempenho de papéis distintos que são combustíveis para conflitos. A pesquisa trata do assunto por meio das teorias: clássica, das relações humanas e teoria estruturalista, da sociologia e psicologia das organizações. Por meio da união dos registros da experiência vivida pela pesquisadora com os estudos bibliográficos confirmou as hipóteses de que os conflitos na organização escolar especial ocorrem por disputa, por legitimidade, por desempenho de papéis, pelas especialidades e por mudanças.
Resumo:
Paediatric intensive care is an expanding specialty that has been shown to improve the quality of care provided to critically ill children. An important aspect of the management of critically ill children includes the provision of effective sedation to reduce stress and anxiety during their stay in intensive care. However, to achieve effective and safe sedation in these children, is recognised as a challenge that is not without risk. Often children receive too much or too little sedation resulting in over sedation or under sedation respectively. These problems have arisen owing to a lack of information regarding altered pharmacokinetics and pharmacodynamics of medicines administered to critically ill children. In addition there are few validated sedation scoring systems in practice with which to monitor level of sedation and titrate medication appropriately. This study consisted of two stages. Stage 1 investigated the reproducibility and practicality of two observational sedation assessment scales for use in critically ill children. The two scales were different in design, the first being simple in design requiring a single assessment of the patient. The second was more complex in design requiring assessment of five patient parameters to obtain an overall sedation score. Both scales were found to achieve good reproducibility (kappa values 0.50 and 0.62 respectively). Practicality of each sedation scale was undertaken by obtaining nursing staff opinion about both scales using questionnaire and interview technique. It was established that nursing staff preferred the second, more complex sedation scale mainly because it was perceived to give a more accurate assessment of level of sedation and anxiety rather than merely level of sedation. Stage 2 investigated the pharmacokinetics and pharmacodynamics of midazolam in critically ill children. 52 children, aged between 0 and 18 years were recruited to the study and 303 blood samples taken to analyse midazolam and its metabolites, I-hydroxyrnidazolam (I-OR) and 4-hydroxymidazolam (4-0H). Analysis of plasma was undertaken using high performance liquid chromatography. A significant correlation was found between midazolam plasma concentration and sedative effect (r=0.598, p=O.OI). It was found that a midazolam plasma concentration of 223ng/ml (±31.9) achieved a satisfactory level of sedation. Only a poor correlation was found between dose of midazolam and plasma concentration of midazolam. Similarly only a poor correlation was found between sedative effect and dose of midazolam. Clearance of midazolam was found to be 6.3mllkglmin (±0.36), which is lower than that reported in healthy children (9.Il-13.3mllkg/min). Age related differences in midazolam clearance were observed in the study. Neonates produced the lowest clearance values (l.63mllkg/min), compared to children aged 1 to 12 months (8.52mllkg/min) who achieved the highest clearance values. Clearance was found to decrease after the age of 12 months to values of 5.34mllkglmin in children aged 7 years and above. Patients with renal (n=5) and liver impairment (n~4) were found to have reduced midazolam clearance (1.37 and 0.74ml/kg/min respectively). Plasma concentrations of I-OH and 4-0H ranged from 0-5 1 89nglml and 0-27 Inglml respectively. All children were found to be capable of producing both metabolites irrespective of age, although no trend was established between age and extent of production of either metabolite. Disease state was found to affect production of l-OH. Patients with renal impairment (n=5) produced the lowest I-OH midazolam plasma ratio (0.059) compared to patients with head injury (0.858). Patients with severe liver impairment were found to be capable of manufacturing both metabolites despite having a severely damaged liver.
Resumo:
Refractive index and structural characteristics of optical polymers are strongly influenced by the thermal history of the material. Polymer optical fibres (POF) are drawn under tension, resulting in axial orientation of the polymer molecular chains due to their susceptibility to align in the fibre direction. This change in orientation from the drawing process results in residual strain in the fibre and also affects the transparency and birefringence of the material (1-3). PMMA POF has failure strain as high as over 100%. POF has to be drawn under low tension to achieve this value. The drawing tension affects the magnitude of molecular alignment along the fibre axis, thus affecting the failure strain. The higher the tension the lower the failure stain will be. However, the properties of fibre drawn under high tension can approach that of fibre drawn under low tension by means of an annealing process. Annealing the fibre can generally optimise the performance of POF while keeping most advantages intact. Annealing procedures can reduce index difference throughout the bulk and also reduce residual stress that may cause fracture or distortion. POF can be annealed at temperatures approaching the glass transition temperature (Tg) of the polymer to produce FBG with a permanent blue Bragg wave-length shift at room temperature. At this elevated temperature segmental motion in the structure results in a lower viscosity. The material softens and the molecular chains relax from the axial orientation causing shrinking of the fibre. The large attenuation of typically 1dB/cm in the 1550nm spectral region of PMMA POF has limited FBG lengths to less than 10cm. The more expensive fluorinated polymers with lower absorption have had no success as FBG waveguides. Bragg grating have been inscribed onto various POF in the 800nm spectral region using a 30mW continuous wave 325nm helium cadmium laser, with a much reduced attenuation coefficient of 10dB/m (5). Fabricating multiplexed FBGs in the 800nm spectral region in TOPAS and PMMA POF consistently has lead to fabrication of multiplexed FBG in the 700nm spectral region by a method of prolonged annealing. The Bragg wavelength shift of gratings fabricated in PMMA fibre at 833nm and 867nm was monitored whilst the POF was thermally annealed at 80°C. Permanent shifts exceeding 80nm into the 700nm spectral region was attained by both gratings on the fibre. The large permanent shift creates the possibility of multiplexed Bragg sensors operating over a broad range. -------------------------------------------------------------------------------------------------------------------- 1. Pellerin C, Prud'homme RE, Pézolet M. Effect of thermal history on the molecular orientation in polystyrene/poly (vinyl methyl ether) blends. Polymer. 2003;44(11):3291-7. 2. Dvoránek L, Machová L, Šorm M, Pelzbauer Z, Švantner J, Kubánek V. Effects of drawing conditions on the properties of optical fibers made from polystyrene and poly (methyl methacrylate). Die Angewandte Makromolekulare Chemie. 1990;174(1):25-39. 3. Dugas J, Pierrejean I, Farenc J, Peichot JP. Birefringence and internal stress in polystyrene optical fibers. Applied optics. 1994;33(16):3545-8. 4. Jiang C, Kuzyk MG, Ding JL, Johns WE, Welker DJ. Fabrication and mechanical behavior of dye-doped polymer optical fiber. Journal of applied physics. 2002;92(1):4-12. 5. Johnson IP, Webb DJ, Kalli K, Yuan W, Stefani A, Nielsen K, et al., editors. Polymer PCF Bragg grating sensors based on poly (methyl methacrylate) and TOPAS cyclic olefin copolymer2011: SPIE.
Resumo:
The inscription of Bragg gratings has been demonstrated in PMMA-based polymer optical fibre. The water affinity of PMMA can introduce significant wavelength change in a polymer optical fibre Bragg grating (POFBG). In polymer optical fibre losses are much higher than with silica fibre. Very strong absorption bands related to higher harmonics of vibrations of the C-H bond dominate throughout the visible and near infrared. Molecular vibration in substances generates heat, which is referred to as the thermal effect of molecular vibration. This means that a large part of the absorption of optical energy in those spectral bands will convert into thermal energy, which eventually drives water content out of the polymer fibre and reduces the wavelength of POFBG. In this work we have investigated the wavelength stability of POFBGs in different circumstances. The experiment has shown that the characteristic wavelength of a POFBG starts decreasing after a light source is applied to it. This decrease continues until equilibrium inside the fibre is established, depending on the initial water content inside the fibre, the surrounding humidity, the optical power applied, and the fibre size. Our investigation has shown that POFBGs operating at around 850 nm show much smaller wavelength reduction than those operating at around 1550 nm in the same fibre; POFBGs with different diameters show different changes; POFBGs powered by a low level light source, or operating in a very dry environment are least affected by this thermal effect.
Resumo:
A new type of fibre-optic biochemical concentration sensor based on a polymer optical fibre Bragg grating (POFBG) is proposed. The wavelength of the POFBG varies as a function of analyte concentration. The feasibility of this sensing concept is demonstrated by a saline concentration sensor. When polymer fibre is placed in a water based solution the process of osmosis takes place in this water-fibre system. An osmotic pressure which is proportional to the solution concentration, will apply to the fibre in addition to the hydraulic pressure. It tends to drive the water content out of the fibre and into the surrounding solution. When the surrounding solution concentration increases the osmotic pressure increases to drive the water content out of the fibre, consequently increasing the differential hydraulic pressure and reducing the POFBG wavelength. This process will stop once there is a balance between the osmotic pressure and the differential hydraulic pressure. Similarly when the solution concentration decreases the osmotic pressure decreases, leading to a dominant differential hydraulic pressure which drives the water into the fibre till a new pressure balance is established. Therefore the water content in the polymer fibre - and consequently the POFBG wavelength - depends directly on the solution concentration. A POFBG wavelength change of 0.9 nm was measured for saline concentration varying from 0 to 22%. For a wavelength interrogation system with a resolution of 1 pm, a measurement of solution concentration of 0.03% can be expected.
Resumo:
We review the state-of-the-art in photonic crystal fiber (PCF) and microstructured polymer optical fiber (mPOF) based mechanical sensing. We first introduce how the unique properties of PCF can benefit Bragg grating based temperature insensitive pressure and transverse load sensing. Then we describe how the latest developments in mPOF Bragg grating technology can enhance optical fiber pressure sensing. Finally we explain how the integration of specialty fiber sensor technology with bio-compatible polymer based micro-technology provides great opportunities for fiber sensors in the field of healthcare.
Resumo:
We propose that specialty store managers, as well as outside sales personnel attached to the store, have selling responsibilities. In addition, we propose that sales personnel, as well as store managers, should have a propensity for leadership, which reflects an individual's enduring disposition to exhibit leadership within the context of his or her organizational roles. In two studies, we develop a new individual difference measure of propensity to lead and investigate its nomological validity within a specialty retail store environment. As predicted, leadership propensity was predictive of self-rated sales performance and a proclivity to identify prospects through cold calls to close sales, to reveal customer orientation, and to exhibit organizational citizenship behavior. We found that propensity to lead did not differ between salespeople and retail store managers, but we found that the respondent's role moderated the relationship between propensity to lead and supervisor performance ratings. Study limitations and managerial implications of this heretofore unidentified trait of salespeople are discussed.
Resumo:
Refractive index and structural characteristics of optical polymers are strongly influenced by the thermal history of the material. Polymer optical fibres (POF) are drawn under tension, resulting in axial orientation of the polymer molecular chains due to their susceptibility to align in the fibre direction. This change in orientation from the drawing process results in residual strain in the fibre and also affects the transparency and birefringence of the material (1-3). PMMA POF has failure strain as high as over 100%. POF has to be drawn under low tension to achieve this value. The drawing tension affects the magnitude of molecular alignment along the fibre axis, thus affecting the failure strain. The higher the tension the lower the failure stain will be. However, the properties of fibre drawn under high tension can approach that of fibre drawn under low tension by means of an annealing process. Annealing the fibre can generally optimise the performance of POF while keeping most advantages intact. Annealing procedures can reduce index difference throughout the bulk and also reduce residual stress that may cause fracture or distortion. POF can be annealed at temperatures approaching the glass transition temperature (Tg) of the polymer to produce FBG with a permanent blue Bragg wave-length shift at room temperature. At this elevated temperature segmental motion in the structure results in a lower viscosity. The material softens and the molecular chains relax from the axial orientation causing shrinking of the fibre. The large attenuation of typically 1dB/cm in the 1550nm spectral region of PMMA POF has limited FBG lengths to less than 10cm. The more expensive fluorinated polymers with lower absorption have had no success as FBG waveguides. Bragg grating have been inscribed onto various POF in the 800nm spectral region using a 30mW continuous wave 325nm helium cadmium laser, with a much reduced attenuation coefficient of 10dB/m (5). Fabricating multiplexed FBGs in the 800nm spectral region in TOPAS and PMMA POF consistently has lead to fabrication of multiplexed FBG in the 700nm spectral region by a method of prolonged annealing. The Bragg wavelength shift of gratings fabricated in PMMA fibre at 833nm and 867nm was monitored whilst the POF was thermally annealed at 80°C. Permanent shifts exceeding 80nm into the 700nm spectral region was attained by both gratings on the fibre. The large permanent shift creates the possibility of multiplexed Bragg sensors operating over a broad range. -------------------------------------------------------------------------------------------------------------------- 1. Pellerin C, Prud'homme RE, Pézolet M. Effect of thermal history on the molecular orientation in polystyrene/poly (vinyl methyl ether) blends. Polymer. 2003;44(11):3291-7. 2. Dvoránek L, Machová L, Šorm M, Pelzbauer Z, Švantner J, Kubánek V. Effects of drawing conditions on the properties of optical fibers made from polystyrene and poly (methyl methacrylate). Die Angewandte Makromolekulare Chemie. 1990;174(1):25-39. 3. Dugas J, Pierrejean I, Farenc J, Peichot JP. Birefringence and internal stress in polystyrene optical fibers. Applied optics. 1994;33(16):3545-8. 4. Jiang C, Kuzyk MG, Ding JL, Johns WE, Welker DJ. Fabrication and mechanical behavior of dye-doped polymer optical fiber. Journal of applied physics. 2002;92(1):4-12. 5. Johnson IP, Webb DJ, Kalli K, Yuan W, Stefani A, Nielsen K, et al., editors. Polymer PCF Bragg grating sensors based on poly (methyl methacrylate) and TOPAS cyclic olefin copolymer2011: SPIE.
Resumo:
In this paper we report, for the first time to our knowledge, an increase of the photosensitivity of a microstructured polymer optical fibre (mPOF) made of undoped PMMA due to applied strain during the fabrication of the gratings. In the work, fibre Bragg gratings (FBGs) have been fabricated in undoped PMMA mPOFs with a hexagonal structure of three rings in the inner cladding. Two sets of FBGs were inscribed at two different resonant wavelengths (827 nm and 1562 nm) at different strains using an UV He-Cd laser at 325 nm focused by a lens and scanned over the fibre. We observed an increase of the reflection of the fibre Bragg gratings when the fabrication strain is higher. The photosensitivity mechanism is discussed in the paper along with the chemical reactions that could underlie the mechanism. Furthermore, the resolution limit of the material was investigated. © 2014 Copyright SPIE.
Resumo:
Step-index polymer optical fiber Bragg gratings (POFBGs) and microstructured polymer optical fiber Bragg gratings (mPOFBGs) present several attractive features, especially for sensing purposes. In comparison to FBGs written in silica fibers, they are more sensitive to temperature and pressure because of the larger thermo-optic coefficient and smaller Young's modulus of polymer materials. (M)POFBGs are most often photowritten in poly(methylmethacrylate) (PMMA) materials using a continuous-wave 325 nm HeCd laser. For the first time to the best of our knowledge, we study photoinduced birefringence effects in (m)POFBGs. To achieve this, highly reflective gratings were inscribed with the phase mask technique. They were then monitored in transmission with polarized light. For this, (m)POF sections a few cm in length containing the gratings were glued to angled silica fibers. Polarization dependent loss (PDL) and differential group delay (DGD) were computed from the Jones matrix eigenanalysis using an optical vector analyser. Maximum values exceeding several dB and a few picoseconds were obtained for the PDL and DGD, respectively. The response to lateral force was finally investigated. As it induces birefringence in addition to the photo-induced one, an increase of the PDL and DGD values were noticed. © 2014 Copyright SPIE.
Resumo:
Unrepeatered 42.7 Gb/s per channel RZ-DPSK transmission over standard SMF-28 fibre with novel URFL based amplification using fibre Bragg gratings is investigated. OSNR and gain performance are studied experimentally and through simulations. Error free transmission for 16 channels across the full C-band with direct detection was experimentally demonstrated for 280 km span length, as well as 6-channel transmission at 340 km and single-channel transmission up to 360 km (75 dB) without employing ROPA or specialty fibres.©2013 Optical Society of America.
Resumo:
We numerically show the possibility of pulse shaping in a mode-locked fiber laser by inclusion of an amplitude-phase spectral filter into the laser cavity. Various advanced temporal waveforms are generated, including parabolic, flat-top and triangular pulses. © 2014 OSA.
Resumo:
The Bragg wavelength of a PMMA based fiber grating is determined by the effective core index and the grating pitch, which, in temperature sensing, depend on the thermo-optic and thermal expansion coefficients of PMMA. These two coefficients are a function of surrounding temperature and humidity. Amorphous polymers including PMMA exhibit a certain degree of anisotropic thermal expansion. The anisotropic nature of expansion mainly depends on the polymer processing history. The expansion coefficient is believed to be lower in the direction of the molecular orientation than in the direction perpendicular to the draw direction. Such anisotropic behavior of polymers can be expected in drawn PMMA based optical fiber, and will lead to a reduced thermal expansion coefficient and larger temperature sensitivity than would be the case were the fiber to be isotropic. Extensive work has been carried out to identify these factors. The temperature responses of gratings have been measured at different relative humidity. Gratings fabricated on annealed and non-annealed PMMA optical fibers are used to compare the sensitivity performance as annealing is considered to be able to mitigate the anisotropic effect in PMMA optical fiber. Furthermore an experiment has been designed to eliminate the thermal expansion contribution to the grating wavelength change, leading to increased temperature sensitivity and improved response linearity. © 2014 Copyright SPIE.