553 resultados para Reprodutibilidade
Resumo:
Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB
Resumo:
Pós-graduação em Engenharia Mecânica - FEG
Resumo:
Pós-graduação em Ciência e Tecnologia de Materiais - FC
Resumo:
This experimental study aimed the evaluation of the use of anthropomorphic phantoms in the analysis of the influence of the acquisition parameters in the contrast of radiographic images. The analyzed factors were the variation of the peak kilovoltage (kVp) and the product of the filament circuit by the time of exposition (mAs). The influence of these factors was verified for different anthropomorphic phantoms: foot, knee and chest. The image contrast behavior with the simulators was compared to values obtained with the use of an aluminum ladder being the behavior of this reference for analysis and discussion. To assure the reproducibility of images, quality control tests were made and evaluation of procedure conditions before the experiments. The results obtained are shown in a scale of images where it was possible to evaluate the impact in the darkness of images. Regions with different compositions were analyzed which were different in image, this way the values of optical density and contrast are represented as charts and graphics. We conclude that the use of anthropomorphic phantoms in the evaluation of the influence of tension of the tube and time of exposition in the contrast of the radiographic images is not indicated for a quantitative analysis through optical density, once they present incompatible results with the data as reference as the aluminum ladder even so these simulators present a great property in qualitative analysis regarding the differentiation of structures and subjective evaluations
Resumo:
The comet assay is a method of DNA damage analysis widely used to quantify oxidative damage, crosslinks of DNA, apoptosis and genotoxicity of chemicals substances as chemical, pharmaceuticals, agrochemicals products, among others. This technique is suitable to detect DNA strand breaks, alkali-labile sites and incomplete excision repair sites and is based on the migration of DNA fragments by microeletroforesis, DNA migrates for the anode forming a “tail”, and the formed image has the appearance of a comet. The slides can be stained with fluorescence or silver, having differences in the microscopy type used for the analysis and the possibility of storage of the slides, moreover, the first one is a stained-method with more difficulties of accomplishment. The image analysis can be performed by a visual way, however, there is a disadvantage as the subjectivity on the results, that can be minimized by an automated method of digital analysis. This process was studied in this report with the aim to perceive the validation of the digital analysis turning it a quantitative method with larger reproductibility, minimizing the variability and imprecision due to the subjective analysis. For this validation we selected 50 comets photographed in a standardized way and printed, afterwards, pictures were submitted to three experienced appraisers, who quantified them manually. Later, the images were processed by free software ImageJ 1.38x, printed and quantified manually by the same appraisers. The intraclass correlation was higher to comet measures after image processing. Following, an algorithm of automated digital analysis from the measures of the comet was developed; the values obtained were compared with those 12 estimated manually after the processing resulting high correlation among the measures. The use of image analysis systems increases ...(Complete abstract click electronic access below)
Resumo:
Technology is growing interest in the use of composites, due to the requirement of lighter materials and more resistant, factors essential to meet the project specifications and reduce the operational cost. In the production of high performance structural composites, considering the aerospace criteria, the domestic industry has shown interest in the process of resin transfer molding (RTM) for reproducibility and low cost. This process is suitable for producing components of polymeric composites with relatively simple geometries, consistent thicknesses, high quality finish with no size limitations. The objective of this work was machined carbon steel to make a matched-die tooling for RTM and produce two composite plates of epoxy resin and carbon fiber fabric with and without induced discontinuities, which were compared towards their impregnation with ultrasound, their properties via tensile tests and thermal analysis. In ultrasonic inspection, it was found good impregnation of the preform of both composites. In the thermal analysis it was possible to check the degradation temperature of the composites, the glass transition temperature and it was found that the composites showed no effective cure cycles, but presented good performance in the tensile test when compared with aluminum alloy 7050 T7451 . The results showed that the injection strategy was appropriate since the laminate exhibited a good quality for the proposed application
Resumo:
Nuclear medicine uses non-sealed sources for exams and treatments, because the movement of these sources, source of patients injected or not, involve a wide range of environmental radiometric levels. To better control of these levels this study was aimed at monitoring points strategically distributed in all environments Sector Technical Nuclear Medicine, Hospital of the Botucatu Medical School, performing two measurements at random times daily for a period of three months, sampling the normal routine of the sector. The detector Geiger-Muller was used for the acquisition of exposure rates of the points, efficiency and reprodutibility test have shown good performance of this equipment for this purpose. The results allowed to make a projection of annual dose for each environment indicating higher risks for Occupationally Exposed Individuals as well as Public Individuals compared with the limits established by the National Commission of Nuclear Energy. Was developed a spatial map of dose that can be used as a visual warning to the regions with the highest exposure to ionizing radiation, enabling reduced risk of a potential exposure
Resumo:
After confirming the high specific mechanical properties of composite materials by scientific studies conducted over the last decades, one of the challenges of this new class of materials is the ability to achieve mass production at a more affordable cost, which has become indispensable. The Resin Transfer Molding (RTM) is an excellent method for manufacturing composite materials. Despite being a process widely used by international companies in the production of high performance structural composites, only a short time the national aviation industry has shown interest in implementing this type of processing to more complex structures and greater structural responsibility. In aeronautical projects, the reproducibility and the relative low cost of this process, several studies have been performed in Brazil for learning and perfecting this technique. This process is suitable for producing polymer components both simple as complex geometry, and allows to achieve consistent thickness, with high quality finish and without limiting range. Polymeric composite components for the high mechanical stress applications such as aircraft structures, satellites, etc., require a strict control of volume fractions of the composite constituents, beyond the knowledge of their mechanical and thermal properties. Therefore, in this experimental work degree study on the mechanical, thermal and of porosity composites processed by RTM processed characterization was performed. This characterization was performed targeting a possible aerospace application of this composite material. For the production of composites, process equipment (RTM RTM injector Radius 2100cc) was used. The processed carbono/epoxy composites were characterized via flexure tests mechanically and thermally analysis via DMA, DSC and TGA. To determine the volume fraction of fibers, the composite samples were analyzed via matrix digestion (ASTM D3171) ... (Complete abstract click electronic access below)
Resumo:
O uso de novas tecnologias para o desenvolvimento de medicamentos constitui uma estratégia promissora no campo da biotecnologia. Nesse sentido, peptídeos com efeito antimicrobiano, produzidos por plantas, animais e microrganismos estão sendo utilizados como modelos para o desenvolvimento de novos medicamentos com aplicações em saúde. Resultados promissores têm sido obtidos em relação à inibição da atividade das enzimas bacterianas DNA girase e topoisomerase IV por derivados peptídicos de toxinas bacterianas, comprovados em ensaios in vitro. Porém, ensaios in vivo não demonstraram reprodutibilidade, basicamente devido à baixa permeabilidade da célula bacteriana a estes compostos. Desta forma, o objetivo deste projeto consiste em aplicar sistemas eficientes para promover o acesso de moléculas peptídicas sintéticas derivadas de toxinas bacterianas, ao meio intracelular e, consequentemente, aos seus alvos intracelulares: as enzimas DNA girase e/ou topoisomerase IV. Com isso, pretendemos solucionar a barreira técnica em que se encontram as aplicações dessa classe de biomoléculas como precursores de novos agentes antibacterianos, o que certamente causaria um importante avanço nas pesquisas desenvolvidas pelo grupo
Resumo:
Delivering to the customers a product or service with the expected quality associated to the huge competitiveness that exists in the market nowadays, has been making organizations increasingly focus on quality planning using techniques which are directed towards the continuous improvement process and production optimization. Thus, this paper aims to improve a machining process using the techniques of experimental design to the optimization and this also includes the analysis of the measurement system. For this purpose, the alloy Nimonic 80A, a nickel base superalloy, was used in the process due to its widespread use for high temperatures, applying this study the robust method proposed by Genichi Taguchi, determining the influence of the factors considered input variables, cutting speed, feed rate, depth of cut, type of tool, lubrication, and material hardness, in the output or response variable, surface roughness, concluding with the use of Taguchi orthogonal array L16 and by analysis of ANOVA that the factor feed rate is significant and offers greater effect on the response variable studied, should be set to 0,12mm/rev. Moreover, the factor type of tool has more influence on the process when compared to other factors, being CP250 the one more suitable to the process. Lastly, the interaction feed rate x cutting speed provides greater significance in the process regarding to surface roughness variable, being the best match between them 0,12mm/rev to the feed rate and 90m/min to the cutting speed. In order to evaluate the measurement system, it was applied the repeatability and reproducibility method (R&R), through which we saw that the system needs improvement (R & R = 88.04% >>> 30%) as the value found in the study was well above compared to the one that classifies the system as inappropriate
Resumo:
Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)
Resumo:
This study aims to determine surface skin doses in dogs (with suspected pulmonary metastasis) submitted to chest X-rays using the technique of thermoluminescence dosimetry. Twenty seven exams from different dogs were performed at the Faculdade de Medicina Veterinária e Zootecnia da Universidade Estadual Paulista (FMVZ-UNESP/Botucatu). The doses were evaluated using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO4:Dy) produced by the Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN). The pulmonary metastasis exams are carried out in three projections, one dorsal-ventral and two lateral-lateral. During the procedures the projection thicknesses and source-skin surface distances were registered. To simulate the dog phantom the dosimeters were positioned in a cubic simulator (30x30x30 cm) of polymethylmethacrylate (PMMA) filled with water and irradiated according to the parameters of projections with the X-ray energies ranging from 45 to 70 kV. To estimate the surface skin dose the dose-response curves were obtained for X-ray energies of 50 and 70 kV using the diagnostic X-ray beam machine of the Instruments Calibration Laboratory of IPEN for doses of 1.5, 2.0, 2.5, 3.5 and 4.0 mGy. The main difficulty of this work was the dog immobilization that is reflected in poor-quality diagnostic imaging and, consequently, demands the repetition of the exams, which contributes to the increase of the doses received by the animals being studied and the clinical staff. The doses evaluated in this type of procedure are between 0.43 and 4.22 mGy. This research has shown to be extremely important for the assessment of doses involved in veterinary diagnostic radiology procedures, and as a parameter in the individual monitoring of pet’s owners who assist the animal positioning and occupationally exposed workers of the Department of Veterinary Radiology
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Anestesiologia - FMB
Resumo:
Pós-graduação em Medicina Veterinária - FCAV