946 resultados para Probe for chromosome translocation
Resumo:
Chromosome behavior in meiosis was studied by air-drying, C-banding and surface-spreading methods in female intersexes of artificial triploid transparent-colored crucian carp (Carassius auratus). Chromosome pairing and contraction were obviously asynchronous. The preferential pairing of two homologous chromosomes was the major pattern of chromosome pairing, and a few triple pairing, repeated pairing, telomer or centromere associating and multiple pairing were also observed in the pachytene cells. The metaphase I cells were mainly composed of univalents, bivalents and trivalents, as well as few of other multivalents, such as tetravalents, pentavalents, hexavalents and heptavalents, were also found in some metaphase I cells. The chromosome elements including uni-, bi-, tri- and other multivalents varied considerably among the metaphase I cells, and the associating patterns of multivalents were also diverse. Some 6 n and 12 n cells, in which premeiotic endomitosis occurred once or twice, were found at the prophase and first metaphase of meiosis, and the pairing and associating patterns were basically similar to that of the triploid cells.
Resumo:
Submitted by zhangdi (zhangdi@red.semi.ac.cn) on 2009-04-13T11:45:31Z
Resumo:
We investigate the dependence of the differential reflection on the structure parameters of quantum dot (QD) heterostructures in pump-probe reflection measurements by both numerical simulations based on the finite-difference time-domain technique and theoretical calculations based on the theory of dielectric films. It is revealed that the value and sign of the differential reflection strongly depend on the thickness of the cap layer and the QD layer. In addition, a comparison between the carrier dynamics in undoped and p-doped InAs/GaAs QDs is carried out by pump-probe reflection measurements. The carrier capture time from the GaAs barrier into the InAs wetting layer and that from the InAs wetting layer into the InAs QDs are extracted by appropriately fitting differential reflection spectra. Moreover, the dependence of the carrier dynamics on the injected carrier density is identified. A detailed analysis of the carrier dynamics in the undoped and p-doped QDs based on the differential reflection spectra is presented, and its difference with that derived from the time-resolved photoluminescence is discussed. (C) 2008 American Institute of Physics.
Resumo:
Silicon-on-insulator (SOI) substrate is widely used in micro-electro-mechanical systems (MEMS). With the buried oxide layer of SOI acting as an etching stop, silicon based micro neural probe can be fabricated with improved uniformity and manufacturability. A seven-record-site neural probe was formed by inductive-coupled plasma (ICP) dry etching of an SOI substrate. The thickness of the probe is 15 mu m. The shaft of the probe has dimensions of 3 mmx100 mu mx15 mu m with typical area of the record site of 78.5 mu m(2). The impedance of the record site was measured in-vitro. The typical impedance characteristics of the record sites are around 2 M Omega at 1 kHz. The performance of the neural probe in-vivo was tested on anesthetic rat. The recorded neural spike was typically around 140 mu V. Spike from individual site could exceed 700 mu V. The average signal noise ratio was 7 or more.
Resumo:
The development of an implantable five channel microelectrode array is presented for neural signal recordings. The detailed fabrication process is outlined with four masked used. The SEM images show that the probe shank is 1.2mm long, 100 mu m wide and 30 mu m thick with the recording sites spaced 200 mu m apart for good signal isolation. The plot of the single recording site impedance versus frequency is shown by test in vitro and the ompedence declines with the increasing frequency. Experiment in vivo using this probe is under way.
Resumo:
A near-field scanning optical microscopy (NSOM) system employing a very-small-aperture laser (VSAL) as an active probe is reported in this Letter. The VSAL in our experiment has an aperture size of 300 nmx300 nm and a near-field spot size of about 600 nm. The resolution of the NSOM system with the VSAL can reach about 600 nm, and even 400 nm. Considering the high output power of the VSAL, such a NSOM system is a potentially useful tool for nanodetection, data storage, nanolithography, and nanobiology.
Resumo:
By analysing the carrier dynamics based on the rate equations and the change of the refractive index due to the efficient carrier capture, we have calculated the carrier capture process in the InAs/GaAs system detected by a simple degenerate pump-probe technique. The calculated results are found to be in good agreement with the experimental findings. Our results indicate that this simple technique, with the clear advantage of being easy to carry out, can be very useful in studying the carrier dynamics for some specific structures such as InAs ultrathin layers embedded in a GaAs matrix described here.
Resumo:
We demonstrate that the carrier capture and relaxation processes in InAs/GaAs quantum dots can be detected by a simple degenerate pump-probe technique. We have observed a rising process in the transient reflectivity, following the initial fast relaxation in a GaAs matrix, and assigned this rising process to the carrier capture from the GaAs barriers to the InAs layers. The assignment was modeled using the Kramers-Kronig relations. The capture time was found to depend strongly on the InAs layer thickness as well as on the excitation density and photon energy. (C) 2000 Elsevier Science Ltd. All rights reserved.
Resumo:
Extracellular neural recording requires neural probes having more recording sites as well as limited volumes. With its mechanical characteristic and abundant process method, Silicon is a kind of material fit for producing neural probe. Silicon on insulator (SOI) is adopted in this paper to fabricate neural probes. The uniformity and manufacturability are improved. The fabricating process and testing results of a series of Multi channel micro neural probes were reported. The thickness of the probe is 15 mu m-30 mu m. The typical impedance characteristics of the record sites are around 2M Omega at 1k Hz. The performance of the neural probe in-vivo was tested on anesthetic rat. The recorded neural spike was typically around 140 mu V. Spike recorded from individual site could exceed 700 mu V. The average signal noise ratio was 7 or more.
Resumo:
Temperature-dependent photoluminescence characteristics of non-polar m-plane ZnO and ZnMgO alloy films grown by metal organic chemical vapor deposition have been studied. The enhancement in emission intensity caused by localized excitons in m-plane ZnMgO alloy films was directly observed and it can be further improved after annealing in nitrogen. The concentration of Zn vacancies in the films was increased by alloying with Mg, which was detected by positron annihilation spectroscopy. This result is very important to directly explain why undoped Zn1-xMgxO thin films can show p-type conduction by controlling Mg content, as discussed by Li [Appl. Phys. Lett. 91, 232115 (2007)].
Resumo:
A kind of optical pH sensor was demonstrated that is based on a pH-sensitive fluorescence dye-doped (eosin) cellulose acetate (CA) thin-film modified microstructured polymer optical fiber (MPOF). It was obtained by directly inhaling an eosin-CA-acetic acid mixed solution into array holes in a MPOF and then removing the solvent (acetic acid). The sensing film showed different fluorescence intensities to different pH solutions in a pH range of 2.5-4.5. Furthermore, the pH response range could be tailored through doping a surfactant, hexadecyl trimethyl ammonium bromide (CTAB), in the sensing film. (c) 2007 Optical Society of America.
Resumo:
In this article, we report an optical fluoride probe based on microstructured polymer optical fibers (MPOFs) which is modified with morin-Al complex doped silica gel film. This probe is fabricated by sol-gel fluxion coating process. Sol solution doped with morin-Al is directly inhaled into array holes of MPOF and then forms morin-Al-gel matrix film in them. The sensing probe shows different fluorescence intensity to different fluoride ion concentrations in the aqueous solution. The range of response is 550 mmol/L, under the condition of pH 4.6. Crown Copyright (C) 2009 Published by Elsevier B.V. All rights reserved.