957 resultados para Nerve Conduction
Resumo:
Some synthetic metals show in addition to good conductivity, high microwave dielectric constants. In this work, it is shown how conduction-electron spin resonance(CESR) lineshape can be affected by these high constants. The conditions for avoiding these effects in the CESR measurements are discussed as well as a method for extracting microwave dielectric constants from CESR lines. (C) 1995 Academic Press, Inc.
Resumo:
CAUDA equina syndrome (CES) has long been recognized as a rare complication of spinal anesthesia.(1) CES has been described after administration of spinal anesthetics with lidocaine(2) and bupivacaine.(3) In 1991,(4) CES was reported after continuous spinal anesthesia with 1% tetracaine. In 1980, at our university hospital, six adult female patients underwent perineal gynecologic surgery using a spinal anesthetic of 2 ml tetracaine, 1.2%, in 10% glucose. The concentration of the injected tetracaine was unknown by the anesthetists. In all cases, lumbar puncture was performed at the L3-L4 interspace with a disposable spinal needle while the patients were in the sitting position. CES was first diagnosed 72 h or later postoperatively; previous diagnosis was not possible because patients had an indwelling urethral catheter. The diagnosis of CES was confirmed in all patients. During the past year, after institutional approval and informed consent, clinical, magnetic resonance imaging, electromyographic examinations, and conduction studies were performed in three of the above patients. Examinations were not possible on the other three patients because one had recently died, another could not be located, and the third refused to participate. T1 and T2 magnetic resonance image readings were obtained with Gadolinium contrast from a 0.5 Tesla General Electric apparatus (General Electric, Tokyo, Japan). Bilateral sensory and motor conduction studies of the sciatic nerve branches were obtained using a two-channel Nihon-Kohden Neuropack 2 (Nihom-Kohden Corporation, Tokyo, Japan). Electromyography was performed in accordance with conventional techniques.(5,6)
Resumo:
Inferior Alveolar Nerve (IAN) transposition is an option for prosthetic rehabilitation in cases of moderate or even severe bone reabsorption for patients that do not tolerate removable dentures. The aim of the present report is to describe an inferior alveolar nerve transposition with involvement of the mental foramen for implant placement. The surgical procedure was performed under local anesthesia, by the inferior alveolar, lingual and buccal nerve blocking technique. Centripetal osteotomy was performed, and bone tissue was removed, leaving the nerve tissue free in the foramen area. After that, transsection of the incisor nerve was performed, and lateral osteotomy was started from the buccal direction, toward the trajectory of the IAN. The procedure was concluded, by making use of a delicate resin spatula to manipulate the vascular-nervous bundle. The drilling sequence for placing the dental implants was performed, and autogenous bone was harvested using a bone collector attached to the surgical suction appliance. After the implants were placed, the bone tissue previously collected during the osteotomies and drilling processes was placed in order to protect the IAN from contact with the implants. The surgical protocol for inferior alveolar nerve transposition, followed by implant placement presented excellent results, with complete recovery of the sensitivity, seven months after the surgical procedure.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
We present an optimistic neural solution to the depressing challenge of decubitus pressure ulcers in the paraplegic patient. This is a limited study of two paraplegic men followed for several years. Sural nerve grafts, performed end-to-side, successfully bridged the sciatic nerve to intercostal nerves with surprising benefits for both men.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
In view of the relevance of the mylohyoid nerve to clinical difficulties in achieving deep analgesia of the lower incisors, a dissection study was undertaken. Dissections from 29 adult cadavers of both sexes were studied with the aid of a dissecting microscope. The following observations were made: a supplementary branch of the mylohyoid nerve entered the mandible through accessory foramina in the lingual side of the mandibular symphysis in 50% of the cases; it generrally arose from the right side (76.9%) and entered the inferior retromental foramen (84.6%); the mylohyoid nerve branch either ended directly in the incisor teeth and the gingiva or joined the ipsilateral or contralateral incisive nerve. In view of this information concerning the high incidence of possible involvement of the mylohyoid nerve in mandibular sensory innervation, it is advisable to block it whenever intervention in the lower incisors is indicated. Routine mylohyoid injection is recommended after mental nerve block. If the inferior alveolar nerve is chosen for anesthetic purposes, additional mylohyoid injection should be given only if pain persists. The mylohyoid injection should be given at the inferior retromental foramen on the median aspect of the inferior border of the mandible through extraoral approach.
Resumo:
Gingival mucosae of man and the adult Cebus apella monkey were fixed for 3 hr in modified Karnovsky fixative containing 2.5% glutaraldehyde, 2% formaldehyde in 0.1 M sodium phosphate buffer (pH=7.4). The specimens were postfixed in 1% osmium tetroxide in 0.1 M sodium phosphate buffer at 4°C for 2 hr, dehydrated in a graded alcohol series and embedded in Epon 812. Thick sections of 1-3 μm and ultrathin sections of 40-80 nm in thickness were cut with glass knives on an LKB ultramicrotome. The thick sections were stained with toluidine blue solution, and the grids were stained with uranyl acetate and lead citrate and examined under a Philips EM-301 electron microscope. Our observations permitted us to conclude that: both gingival mucosae, of man and the Cebus apella monkey, have lamellar nerve endings; these corpuscles are localized in the papillar space of the epithelium and do not contact closely with the basement membrane; the nerve endings are composed of an afferent fiber which subdivides several times and forms irregular flattened or discoidal expansions; the laminae of the lamellar cells are very thin near the terminal axon and are larger and irregular in shape at the peripheral portion of the corpuscle; the terminal axon shows abundant mitochondria, myelin figures, clear vesicles, and multivesicular bodies; between the axoplasm membrane and adjacent cytoplasmic lamina and between the lamellae, small desmosome type junctions are noted; and the cytoplasmic material of the lamellae cells is characterized by the presence of numerous microfilaments, microtubules, mitochondria, rough endoplasmic reticulum, and caveolae.
Resumo:
Compression and section of the facial nerve were performed in 48 rats in order to study the anatomopathological alterations occurring after daily intraperitoneal injections of 100 mg of exogenous gangliosides (Sinaxial®) for 45, 90, 180 days. In groups submitted to nerve compression, the histopathological changes were discrete and in the 180-day subgroups the nerve was practically normal. In animals submitted to section and neurorrhaphy there was formation of an amputation neuroma, a granuloma around the suture, axonal unstructuration and inter and perineural fibrosis. No significant differences were observed between the groups submitted or not to injection of exogenous gangliosides, indicating that the major factors involved in the quality of nerve regeneration were the technique and the formation of fibrosis and of an amputation neuroma.
Resumo:
The Dysonian line in the limit d < or ∼ δ, where d is the thickness and 6 the skin depth, was fitted to a combination of absorption and dispersion Lorentzian lines. This procedure allows one to determine not only microwave conductivity from the Dysonian line but also the true g value, linewidth, and paramagnetic susceptibility by the measurement of five parameters of the ESR absorption-derivative Dysonian line. ©1990 Academic Press, inc.
Resumo:
Nerve regeneration in a sensory nerve was obtained by the application of different techniques: inside-out vein graft (IOVG group) and standard vein graft (SVG group). These techniques provide a good microenvironment for axon regeneration in motor nerves, but their efficiency for regeneration of sensory nerves is controversial. The saphenous nerve was sectioned and repaired by the inside-out and standard vein graft techniques in rats. After 4, 12, and 20 weeks the graft and the distal stump were observed under electron microscopy. In each studied period, the pattern, diameters, and thickness of the myelin sheaths of the regenerated axons were measured in the graft and distal stump. A comparative study about the regenerated nerve fibers by these two different techniques was performed. Regenerated nerve fibers were prominent in both vein grafts 4 weeks after the surgical procedures. On the other hand, in the distal stump, regenerated nerve fibers were observed only from 12 weeks. In both inside-out vein graft and standard vein graft statistical difference was not observed about the diameters and thickness of the myelinated fibers after 20 weeks. On the other hand, the inside-out group had greater regenerated axon number when compared to the standard group. There is a capillary invasion in both graft and distal stump, especially in the IOVG group. The regenerated axons follow these capillaries all the time like satellite microfascicles. After 20 weeks, the diameters of regenerated fibers repaired by the standard vein graft technique were closer to the normal fibers compared to the inside-out vein graft. On the other hand, the pattern of these regenerated axons was better in the IOVG group.
Resumo:
The ulnar-to-median nerve anastomosis in the forearm is a very rare occurrence, not mentioned in many anatomical text books. We found only 4 cases cited in medical literature. Here we describe 2 new cases, for which diagnosis was suspected when the compound muscle action potential of the abductor pollicis brevis muscle (APB), obtained by maximal stimulation of the median nerve at the elbow, was lower than that obtained at the wrist. The diagnosis was confirmed by stimulation of the ulnar nerve at the elbow, which evoked a compound muscle action potential of the APB with a clear negative initial deflection without volume-conducted potential.
Resumo:
Introduction: Children with Moebius syndrome may present paralysis of cranial nerves III, IV, V, VI, VII, VIII, IX, X and XII, compromising motor and sensorial functions. Hands and feet defects (syndactyly, equinovarus and arthrogryposis) are frequently associated. These manifestations can be attributed to the use of misoprostol during pregnancy to induce abortion. Study design: Clinical prospective. Aim: To evaluate the main clinical manifestations, hearing acuity and possible etiologic factors in children with Moebius syndrome. Material and method: The children were submitted to clinical, otolaryngological and hearing acuity assessment. Hearing acuity was evaluated through behavioral tests, pure tone audiometry, tympanometry and auditory brainstem response (ABR). We investigated possible etiologic factors. Results: Three boys and two girls were evaluated. The main manifestations were: facial paralysis, paralysis of masseter muscle, defects in dental occlusion, retraction of tympanic membrane, equinovarus, oblique palpebral fissure and tongue atrophy. Conductive hearing loss was detected in three children and sensorineural hearing loss in one child. The use of misoprostol during pregnancy was reported by four mothers. Conclusions: The children with Moebius syndrome evaluated in the present study manifested palsies of various cranial nerves, especially V, VII and XII nerves, responsible for motor and sensorial alterations. Inadequate eustachian tube function associated to conductive hearing loss was frequent. The use of misoprostol during pregnancy was reported by the mothers and it was considered a possible etiologic factor.
Resumo:
This paper presents a new pre-regulator boost operating in the boundary area between the continuous and discontinuous conduction modes of the boost inductor current, where the switches and boost diode performing zero-current commutations during its turn-off, eliminating the disadvantages related to the reverse recovery losses and electromagnetic interference problems of the boost diode when operating in the continuous conduction mode. Additionally, the interleaving technique is applied in the power cell, providing a significant input current ripple reduction. It should be noticed that the main objective of this paper is to present a complete modeling for the converter operating in the critical conduction mode, allowing an improved design procedure for interleaved techniques with high input power factor, a complete dynamic analysis of the structure, and the possibility of implementing digital control techniques in closed loop.