967 resultados para Measuring instruments.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method for measuring the imaging quality of a projection system with mirror-symmetric FOCAL marks is proposed, and the principle of the method is described. Through experiments, it is demonstrated that not only the axial aberrations but also the lateral aberrations can be measured with high accuracy by the method. The advantages of the method include obtaining more aberrations than the FOCAL technique and making it much simpler to perform a full-scale measurement of the imaging quality of a lithographic projection system. (C) 2006 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A padronização para a fabricação de instrumentos endodônticos em aço inoxidável contribuiu para o desenvolvimento de novos aspectos geométricos. Surgiram propostas de alterações no desenho da haste helicoidal, da seção reta transversal, da ponta, da conicidade e do diâmetro na extremidade (D0). Concomitantemente, o emprego de ligas em Níquel-Titânio possibilitou a produção de instrumentos acionados a motor, largamente empregados hoje. A cada ano a indústria lança instrumentos com diversas modificações, sem, contudo, disponibilizar informações suficientes quanto às implicações clínicas destas modificações. Existe um crescente interesse no estudo dos diferentes aspectos geométricos e sua precisa metrologia. Tradicionalmente, a aferição de aspectos geométricos de instrumentos endodônticos é realizada visualmente através de microscopia ótica. Entretanto, esse procedimento visual é lento e subjetivo. Este trabalho propõe um novo método para a metrologia de instrumentos endodônticos baseado no microscópio eletrônico de varredura e na análise digital das imagens. A profundidade de campo do MEV permite obter a imagem de todo o relevo do instrumento endodôntico a uma distância de trabalho constante. Além disso, as imagens obtidas pelo detector de elétrons retro-espalhados possuem menos artefatos e sombras, tornando a obtenção e análise das imagens mais fáceis. Adicionalmente a análise das imagens permite formas de mensuração mais eficientes, com maior velocidade e qualidade. Um porta-amostras específico foi adaptado para obtenção das imagens dos instrumentos endodônticos. Ele é composto de um conector elétrico múltiplo com terminais parafusados de 12 pólos com 4 mm de diâmetro, numa base de alumínio coberta por discos de ouro. Os nichos do conector (terminais fêmeas) têm diâmetro apropriado (2,5 mm) para o encaixe dos instrumentos endodônticos. Outrossim, o posicionamento ordenado dos referidos instrumentos no conector elétrico permite a aquisição automatizada das imagens no MEV. Os alvos de ouro produzem, nas imagens de elétrons retro-espalhados, melhor contraste de número atômico entre o fundo em ouro e os instrumentos. No porta-amostras desenvolvido, os discos que compõem o fundo em ouro são na verdade, alvos do aparelho metalizador, comumente encontrados em laboratórios de MEV. Para cada instrumento, imagens de quatro a seis campos adjacentes de 100X de aumento são automaticamente obtidas para cobrir todo o comprimento do instrumento com a magnificação e resolução requeridas (3,12 m/pixel). As imagens obtidas são processadas e analisadas pelos programas Axiovision e KS400. Primeiro elas são dispostas num campo único estendido de cada instrumento por um procedimento de alinhamento semi-automático baseado na inter-relação com o Axiovision. Então a imagem de cada instrumento passa por uma rotina automatizada de análise de imagens no KS400. A rotina segue uma sequência padrão: pré-processamento, segmentação, pós-processamento e mensuração dos aspectos geométricos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A review article detailing the background, development and functionality of the Windermere Profiler, a multi parameter environmental monitoring instrument for use in lakes, reservoirs and rivers. The article explains the requirement for regular data collection by the Freshwater Biological Association at Windermere. The article covers the requirements of a profiling instrument, the design considerations, the electronic circuitry, the computer program, the operation of the computer software, the profiler in use and further developments to the design. A number of figures and images accompany the article.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Frequency resolved optical gating (FROG), is an effective technique for characterizing the ultrafast laser pulses. The multi-shot second harmonic generation (SHG) FROG is the most sensitive one in different FROGs. In this paper we use this technique to measure the femtosecond optical pulses generated by a conventional Ti:sapphire oscillator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of digital holographic interferometry on the quantitative measurement of the domain inversion in a RuO2: LiNbO3 crystal wafer is presented. The recorded holograms are reconstructed by the angular spectrum method. From the reconstructed phase distribution we can clearly observe the boundary between the inverted and un-inverted domain regions. Comparisons with the results reconstructed by use of the Fresnel transform method are given. Factors that influence the measurement include the spectrum filter size and the spectrum movement are discussed. The spectrum filter size has an effect on the measurement of the details. Although the spectrum movement affects every single reconstructed image, it has no influence on the final measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report an observation of femtosecond optical fluctuations of transmitted light when a coherent femtosecond pulse propagates through a random medium. They are a result of random interference among scattered waves coming from different trajectories in the time domain. Temporal fluctuations are measured by using cross-correlated frequency optical gating. It is shown that a femtosecond pulse will be broadened and distorted in pulse shape while it is propagating in random medium. The real and imaginary components of transmitted electric field are also distorted severely. The average of the fluctuated transmission pulses yields a smooth profile, probability functions show good agreement with Gaussian distribution. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method for measuring the coma of a lithographic projection system is proposed and the principle of the method is described. By utilizing mirror-symmetry marks, the adverse effects of axial aberrations on the coma measurement are avoided. Experimental results demonstrated that the method has high accuracy. Compared with TAMIS, the conventional technique used for coma measurement, the method is more reliable because the influences of the process factors on the lateral displacements have been considered. (c) 2006 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A parallel plate interferometer with a reflecting mirror for measuring angular displacement is proposed. A deflection angle of a beam caused by an angular displacement is amplified by use of a reflecting mirror to increase the optical path difference (OPD) in the plane-parallel plate, which provides high sensitivity of the phase measurement. Detection of light transmitted through the plane-parallel plate with a position sensitive detector (PSD) enables high accurate measurement of the initial angle of incidence to the plane-parallel plate with insensitivity to stray light. The improved parallel plate interferometer achieves a measurement repeatability of 10(-8) rad. (C) 2007 The Optical Society of Japan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN] Store brands account for and important market share in the Spain and a further increase in expected in the next years due to the downturn. However, there is lack of research on store brand customer-based Brand Equity. This study attempts to propose an integrated model of Brand Equity in store or retailer brands, based on Aaker s well-known conceptual model. We propose a consumer-based model, including the main sources or dimensions of Brand Equity and considering the intention to purchase as a consequence. Based on a sample of 362 consumers and 5 store brands, structural equation modeling is used to test research hypotheses. The results obtained reveal that store brand awareness, loyalty along with store brand perceived quality have a significant influence on consumers intention to purchase store brands. Our study suggests that marketers and marketing managers from retailing companies should carefully consider the Brand Equity components when designing their brand strategies, and develop marketing activities in order to enhance their brands awareness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

在起偏器待测波片检偏器系统基础上提出一种四区域测量波片相位延迟量的方法。调整待测波片和检偏器的方位角,获得相应的四组光强值,通过线性运算得到待测波片的相位延迟量,完全消除了起偏器和检偏器不完全消光带来的误差。由于测量系统中不存在标准波片或其他相位调制元件,允许测量波长仅受偏振棱镜和探测器的限制,因此四区域法可适用于很大波长范围内的波片测量。以λ/4波片为例,理论分析了测量系统利用四区域测量法后的仪器误差为σ≤±3.49065×10-3rad(约0.2°),精度比原算法提高约1个数量级。实验验证了四区域法能有效提高系统精度。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta investigação objetivou a eficácia antimicrobiana de agentes desinfetantes utilizados na desinfecção dos instrumentos endodônticos, durante o período transoperatório do tratamento endodôntico. A atividade antimicrobiana dos desinfetantes álcool isopropílico, acetona e ácido peracético (PAA) foi avaliada sobre microrganismos planctônicos através de teste de contato (time kill assay), utilizando inóculo de 9,9 X 109 a 1,2 X 1012 unidades formadoras de colônia (UFC) e por determinação da concentração bactericida mínima (CBM), usando inóculo de aproximadamente 106 UFC. Os agentes químicos também foram avaliados sobre Enterococcus faecalis (E. faecalis) ATCC 29212 cultivada em matriz de dentina (ex vivo) visando a formação de biofilme. O biofilme (organismos sésseis) microbiano foi removido com limas tipo Kerr (LK), até as lâminas estarem visualmente preenchidas. As LK contaminadas foram usadas como carreadores (logo após a contaminação ou secas dentro de uma câmara de fluxo laminar por 10 minutos). As LK carreadoras foram imersas em álcool isopropílico ou acetona ambos a 80%, ou em Ácido peracético 2%, por 30 ou 60 segundos. As limas foram posteriormente colocadas em tubos de ensaio contendo caldo Enterococcosel para observar o crescimento dos enterococos viáveis. Depois, os experimentos in vivo foram realizados com LK contaminadas por material necrótico pulpar da região cervical de dentes indicados para tratamento endodôntico. As LK contaminadas foram imersas, por 30 ou 60 segundos, em 80% de acetona ou 80% de álcool isopropílico ou 2% de PAA. As limas foram então inoculadas em tubos de ensaio contendo meio tioglicolato. Os organismos que cresceram, foram identificados após o tratamento com PAA. A corrosão mediada pelos agentes químicos também foi testada, após a incubação de LK de aço inoxidável e de NiTi por 60 minutos, medindo o peso das LK antes e depois da imersão e por microscopia eletrônica de varredura (MEV). Todos os agentes químicos foram capazes de eliminar ou reduzir a viabilidade das bactérias de espécies planctônicas Gram-negativas e Gram-positivas, embora a atividade dos produtos químicos sobre E. faecalis sésseis em testes de carreadores de LK demonstrou que o álcool isopropílico ou acetona foram incapazes de eliminar a contaminação bacteriana, especialmente, quando as limas foram secas previamente à exposição aos produtos químicos, por 15 ou 30 segundos. O PAA demonstrou a melhor atividade antimicrobiana e eliminou a viabilidade das células sésseis E. faecalis de ambas as limas endodônticas tipo K úmidas ou secas, após exposição por 15 segundos (100% de eliminação). Os experimentos desenvolvidos in vivo demonstraram que o PAA foi o agente mais eficaz (p<0,05), capaz de eliminar a viabilidade dos organismos em 92% das LK imersas depois de 60 segundos, quando comparado com acetona (64%) ou com álcool isopropílico (50%). O crescimento microbiano após o contato com o PAA demonstrou que somente o grupo dos Lactobacillus sp foi resistente a essa substância química. Os agentes químicos não demonstraram ser corrosivos, após a imersão por 1 hora, tanto por pesagem quanto por MEV. Foi observado que o PAA foi o agente mais eficaz para ser utilizado como desinfetante de instrumentos, durante o período transoperatório do tratamento endodôntico.