932 resultados para GENESIS (Computer system)


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The JModel suite consists of a number of models of aspects of the Earth System. The Java programmes model in detail aspects of the cycles of some major biogeochemical elements that exemplify the range of geochemical processes in marine environments.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Este proyecto de investigación busca usar un sistema de cómputo basado en modelación por agentes para medir la percepción de marca de una organización en una población heterogénea. Se espera proporcionar información que permita dar soluciones a una organización acerca del comportamiento de sus consumidores y la asociada percepción de marca. El propósito de este sistema es el de modelar el proceso de percepción-razonamiento-acción para simular un proceso de razonamiento como el resultado de una acumulación de percepciones que resultan en las acciones del consumidor. Este resultado definirá la aceptación de marca o el rechazo del consumidor hacia la empresa. Se realizó un proceso de recolección información acerca de una organización específica en el campo de marketing. Después de compilar y procesar la información obtenida de la empresa, el análisis de la percepción de marca es aplicado mediante procesos de simulación. Los resultados del experimento son emitidos a la organización mediante un informe basado en conclusiones y recomendaciones a nivel de marketing para mejorar la percepción de marca por parte de los consumidores.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Se presentan dos investigaciones sobre la enseñanza y el aprendizaje de la integral definida y la integral impropia. Se destacan los aspectos relacionados con el uso de los CAS (Computer Algebra System) Derive y Maple. Se hace incapié en el papel que ha jugado cada uno de ellos en la investigación.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A vision system for recognizing rigid and articulated three-dimensional objects in two-dimensional images is described. Geometrical models are extracted from a commercial computer aided design package. The models are then augmented with appearance and functional information which improves the system's hypothesis generation, hypothesis verification, and pose refinement. Significant advantages over existing CAD-based vision systems, which utilize only information available in the CAD system, are realized. Examples show the system recognizing, locating, and tracking a variety of objects in a robot work-cell and in natural scenes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In order to simplify computer management, several system administrators are adopting advanced techniques to manage software configuration of enterprise computer networks, but the tight coupling between hardware and software makes every PC an individual managed entity, lowering the scalability and increasing the costs to manage hundreds or thousands of PCs. Virtualization is an established technology, however its use is been more focused on server consolidation and virtual desktop infrastructure, not for managing distributed computers over a network. This paper discusses the feasibility of the Distributed Virtual Machine Environment, a new approach for enterprise computer management that combines virtualization and distributed system architecture as the basis of the management architecture. © 2008 IEEE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Ticks are classified into three families: Argasidae, Ixodidae, and Nutalliellidae. The taxonomy and phylogeny within Ixodidae are still discussed by the specialists, thus requiring further studies. Amblyomma cajennese and Amblyomma aureolatum (Brazil) belong to two species complexes known as “cajennese” and “ovale”, respectively, and are directly related to the transmission of the Brazilian spotted fever. This confirms the medical and veterinary significance of these species, as well as the need for further morphological studies that will bring a better understanding of their taxonomy, phylogeny, and control. In this context, the present study aimed to characterize the morphology of the male reproductive system of A. cajennese and A. aureolatum when unfed and after 4 days of feeding, thereby seeking to: (a) distinguish the two species or “complexes”, and (b) study an internal system which has the potential to be targeted by acaricides. Therefore, males from both species (unfed and after 4 days of feeding) were cold-anesthetized, dissected, and had their reproductive systems removed for histological analysis. The results showed that the morphology of the male reproductive system is generally similar between both species, like in other Ixodidae ticks, exhibiting a multilobed accessory gland complex related to seminal fluid secretion, a pair of vasa deferentia and a pair of testes housing germ cells (spermatocytes) in different stages. The main differences were found in the development of the accessory gland complex cells and germ cells, showing that the maturation of the male reproductive system starts later in A. aureolatum, when compared to A. cajennese. However, during the blood meal, A. aureolatum development is increased, thus making germ cell maturation and gland complex activity higher than in A. cajennese. This study shows the differences in the development of the male reproductive systems of both species, while providing information that can assist in the establishment of new control methods.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The main problem connected to cone beam computed tomography (CT) systems for industrial applications employing 450 kV X-ray tubes is the high amount of scattered radiation which is added to the primary radiation (signal). This stray radiation leads to a significant degradation of the image quality. A better understanding of the scattering and methods to reduce its effects are therefore necessary to improve the image quality. Several studies have been carried out in the medical field at lower energies, whereas studies in industrial CT, especially for energies up to 450 kV, are lacking. Moreover, the studies reported in literature do not consider the scattered radiation generated by the CT system structure and the walls of the X-ray room (environmental scatter). In order to investigate the scattering on CT projections a GEANT4-based Monte Carlo (MC) model was developed. The model, which has been validated against experimental data, has enabled the calculation of the scattering including the environmental scatter, the optimization of an anti-scatter grid suitable for the CT system, and the optimization of the hardware components of the CT system. The investigation of multiple scattering in the CT projections showed that its contribution is 2.3 times the one of primary radiation for certain objects. The results of the environmental scatter showed that it is the major component of the scattering for aluminum box objects of front size 70 x 70 mm2 and that it strongly depends on the thickness of the object and therefore on the projection. For that reason, its correction is one of the key factors for achieving high quality images. The anti-scatter grid optimized by means of the developed MC model was found to reduce the scatter-toprimary ratio in the reconstructed images by 20 %. The object and environmental scatter calculated by means of the simulation were used to improve the scatter correction algorithm which could be patented by Empa. The results showed that the cupping effect in the corrected image is strongly reduced. The developed CT simulation is a powerful tool to optimize the design of the CT system and to evaluate the contribution of the scattered radiation to the image. Besides, it has offered a basis for a new scatter correction approach by which it has been possible to achieve images with the same spatial resolution as state-of-the-art well collimated fan-beam CT with a gain in the reconstruction time of a factor 10. This result has a high economic impact in non-destructive testing and evaluation, and reverse engineering.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Percutaneous nephrolithotomy (PCNL) for the treatment of renal stones and other related renal diseases has proved its efficacy and has stood the test of time compared with open surgical methods and extracorporal shock wave lithotripsy. However, access to the collecting system of the kidney is not easy because the available intra-operative image modalities only provide a two dimensional view of the surgical scenario. With this lack of visual information, several punctures are often necessary which, increases the risk of renal bleeding, splanchnic, vascular or pulmonary injury, or damage to the collecting system which sometimes makes the continuation of the procedure impossible. In order to address this problem, this paper proposes a workflow for introduction of a stereotactic needle guidance system for PCNL procedures. An analysis of the imposed clinical requirements, and a instrument guidance approach to provide the physician with a more intuitive planning and visual guidance to access the collecting system of the kidney are presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An algorithm for the real-time registration of a retinal video sequence captured with a scanning digital ophthalmoscope (SDO) to a retinal composite image is presented. This method is designed for a computer-assisted retinal laser photocoagulation system to compensate for retinal motion and hence enhance the accuracy, speed, and patient safety of retinal laser treatments. The procedure combines intensity and feature-based registration techniques. For the registration of an individual frame, the translational frame-to-frame motion between preceding and current frame is detected by normalized cross correlation. Next, vessel points on the current video frame are identified and an initial transformation estimate is constructed from the calculated translation vector and the quadratic registration matrix of the previous frame. The vessel points are then iteratively matched to the segmented vessel centerline of the composite image to refine the initial transformation and register the video frame to the composite image. Criteria for image quality and algorithm convergence are introduced, which assess the exclusion of single frames from the registration process and enable a loss of tracking signal if necessary. The algorithm was successfully applied to ten different video sequences recorded from patients. It revealed an average accuracy of 2.47 ± 2.0 pixels (∼23.2 ± 18.8 μm) for 2764 evaluated video frames and demonstrated that it meets the clinical requirements.