893 resultados para Feature Extraction Algorithms
Resumo:
A sensitive and reproducible stir bar-sorptive extraction and high-performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of carbamazepine, carbamazepine-10,11-epoxide, phenytoin and phenobarbital in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. Important factors in the optimization of SBSE efficiency such as pH, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) assured recoveries ranging from 72 to 86%, except for phenytoin (62%). Separation was obtained using a reverse phase C-18 column with UV detection (210 nm). The mobile phase consisted of water: acetonitrile (78:22, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.08-40.0 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125-40.0 mu g mL(-1) for phenytoin, The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.0, 4.0 and 20.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 8.8% and all inter-CVs were less than 10%. Limits of quantification were 0.08 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125 mu g mL(-1) for phenytoin. No interference of the drugs normally associated with antiepileptic drugs was observed. Based on figures of merit results, the SBSE/HPLC-UV proved adequate for antiepileptic drugs analyses from therapeutic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
A sensitive and precise stir bar sorptive extraction (SBSE) combined with LC (SBSE/LC) analysis is described for simultaneous determination of methyl, ethyl, propyl, and butyl parabens in commercial cosmetic products in agreement with the European Union Cosmetics Directive 76/768/EEC. Important factors in the optimization of SB SE efficiency are discussed, such as time and temperature of extraction, pH, and ionic strength of the sample, matrix effects, and liquid desorption conditions by different modes (magnetic stirring, ultrasonic). The LOQs of the SBSE/LC method ranged from 30 to 200 ng/mg, with linear response over a dynamic range, from the LOQ to 2.5 mu g/mg, with a coefficient of determination higher than 0.993. The interday precision of the SBSE/LC method presented a coefficient of variation lower than 5%. The effectiveness of the proposed method was proven for analysis of commercial cosmetic products such as body creams, antiperspirant creams, and sunscreens.
Resumo:
A sensitive and reproducible stir bar-sorptive extraction and high performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of rifampicin in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. This miniaturized method can result in faster analysis, higher sample throughput, lower solvent consumption and less workload per sample while maintaining or even improving sensitivity. Important factors in the optimization of SBSE efficiency such as pH, temperature, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) were optimized recoveries ranging from 75 to 80%. Separation was obtained using a reverse phase C(8) column with UV detection (254 nm). The mobile phase consisted of methanol:0.25 N sodium acetate buffer, pH 5.0 (58:42, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.125-50.0 mu g mL(-1). The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.25, 6.25 and 25.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 10% and all inter-CVs were less than 10%. Limits of quantification were 0.125 mu g mL(-1). Stability studies showed rifampicin was stable in plasma for 12 h after thawing; the samples were also stable for 24 h after preparation. Based on the figures of merit results, the SBSE/HPLC-UV proved to be adequate to the rifampicin analyses from therapeutic to toxic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
This paper proposes the use of the q-Gaussian mutation with self-adaptation of the shape of the mutation distribution in evolutionary algorithms. The shape of the q-Gaussian mutation distribution is controlled by a real parameter q. In the proposed method, the real parameter q of the q-Gaussian mutation is encoded in the chromosome of individuals and hence is allowed to evolve during the evolutionary process. In order to test the new mutation operator, evolution strategy and evolutionary programming algorithms with self-adapted q-Gaussian mutation generated from anisotropic and isotropic distributions are presented. The theoretical analysis of the q-Gaussian mutation is also provided. In the experimental study, the q-Gaussian mutation is compared to Gaussian and Cauchy mutations in the optimization of a set of test functions. Experimental results show the efficiency of the proposed method of self-adapting the mutation distribution in evolutionary algorithms.
Resumo:
Introduction. Two-dimensional (2-D) echocardiography is an excellent alternative method to perform endomyocardial biopsies (EB) in special situations, mainly when the patient is in a critical state and cannot go to the catheterization laboratory or when there are contraindications to the use of fluoroscopy as in the pregnancy. Objective. This single-center experience analyzed the last 25 years use of an EB technique guided by echocardiography realized at the bedside on critical patients. Methods. From 1985 to 2010, we performed 76 EB guided by 2-D echocardiography on 59 patients, among whom 38 (64.4%) were critically ill with examinations at the bedside; among 10 (16.9%) subjects, the procedure was carried out simultaneously with fluoroscopy for safety`s sake during the learning period. In addition, 8 (13.6%) were unavailable for fluoroscopy, and 3 (5.1%) required a hybrid method due to an intracardiac tumor. Results. The main adverse effects included local pain (n = 4, 5.6%); difficult out successful puncture due to previous biopsies (n = 4, 5.6%); local hematoma without major consequences (n = 3, 4.2%); failed but ultimately successful puncture on the first try due to previous biopsies or (n = 3, 4.2%); obesity and immediate postoperative period with impossibility to pass the bioptome into the right ventricle; however 2 days later the procedure was repeated successfully by echocardiography (n = 1, 1.4%). All myocardial specimens displayed suitable size. There were no undesirable extraction effects on the tricuspid valve tissue. In this series, there was no case of death, hemopericardium, or other major complication as a direct consequence of the biopsy. Conclusion. 2-D echocardiography is a special feature to guide EB is mainly in critically ill patients because it can be performed at the bedside without additional risk or disadvantages of fluoroscopy. The hybrid method associating 2-D echocardiography and fluoroscopy allows the procedure in different situations such as intracardiac tumor cases.
Resumo:
Extraction of intracellular protein from Escherichia coli is traditionally achieved by mechanical disruption. A chemical treatment that destroys the integrity of the bacterial cell wall and could provide an alternative technique is examined in this study. Treatment with a combination of the chelating agent ethylenediaminetetraacetate (EDTA) (greater than 0.3 mM) and the chaotropic agent urea (6 M) is highly effective at releasing protein from uninduced E. coli. The 6 M urea in the presence of 3 mM EDTA can release cytoplasmic protein from both logarithmic-phase and stationary-phase E. coli cells at levels equivalent to mechanical disruption. The concentrations of the two chemical agents were the major variables affecting the maximum levels of protein release. Several minor variables and interactions were also identified. The kinetics of protein release is first order. For 2, 4, and 6 M urea with 3 mM EDTA, the time constant is approximately 2.5 min independent of urea concentration. Kinetics for 3 mM EDTA without urea is considerably slower, with a time constant of 12.3 min. (C) 1997 John Wiley & Sons, Inc.
Resumo:
A robust semi-implicit central partial difference algorithm for the numerical solution of coupled stochastic parabolic partial differential equations (PDEs) is described. This can be used for calculating correlation functions of systems of interacting stochastic fields. Such field equations can arise in the description of Hamiltonian and open systems in the physics of nonlinear processes, and may include multiplicative noise sources. The algorithm can be used for studying the properties of nonlinear quantum or classical field theories. The general approach is outlined and applied to a specific example, namely the quantum statistical fluctuations of ultra-short optical pulses in chi((2)) parametric waveguides. This example uses a non-diagonal coherent state representation, and correctly predicts the sub-shot noise level spectral fluctuations observed in homodyne detection measurements. It is expected that the methods used wilt be applicable for higher-order correlation functions and other physical problems as well. A stochastic differencing technique for reducing sampling errors is also introduced. This involves solving nonlinear stochastic parabolic PDEs in combination with a reference process, which uses the Wigner representation in the example presented here. A computer implementation on MIMD parallel architectures is discussed. (C) 1997 Academic Press.
Resumo:
Computer modelling has shown that electrical characteristics of individual pixels may be extracted from within multiple-frequency electrical impedance tomography (MFEIT) images formed using a reference data set obtained from a purely resistive, homogeneous medium. In some applications it is desirable to extract the electrical characteristics of individual pixels from images where a purely resistive, homogeneous reference data set is not available. One such application of the technique of MFEIT is to allow the acquisition of in vivo images using reference data sets obtained from a non-homogeneous medium with a reactive component. However, the reactive component of the reference data set introduces difficulties with the extraction of the true electrical characteristics from the image pixels. This study was a preliminary investigation of a technique to extract electrical parameters from multifrequency images when the reference data set has a reactive component. Unlike the situation in which a homogenous, resistive data set is available, it is not possible to obtain the impedance and phase information directly from the image pixel values of the MFEIT images data set, as the phase of the reactive reference is not known. The method reported here to extract the electrical characteristics (the Cole-Cole plot) initially assumes that this phase angle is zero. With this assumption, an impedance spectrum can be directly extracted from the image set. To obtain the true Cole-Cole plot a correction must be applied to account for the inherent rotation of the extracted impedance spectrum about the origin, which is a result of the assumption. This work shows that the angle of rotation associated with the reactive component of the reference data set may be determined using a priori knowledge of the distribution of frequencies of the Cole-Cole plot. Using this angle of rotation, the true Cole-Cole plot can be obtained from the impedance spectrum extracted from the MFEIT image data set. The method was investigated using simulated data, both with and without noise, and also for image data obtained in vitro. The in vitro studies involved 32 logarithmically spaced frequencies from 4 kHz up to 1 MHz and demonstrated that differences between the true characteristics and those of the impedance spectrum were reduced significantly after application of the correction technique. The differences between the extracted parameters and the true values prior to correction were in the range from 16% to 70%. Following application of the correction technique the differences were reduced to less than 5%. The parameters obtained from the Cole-Cole plot may be useful as a characterization of the nature and health of the imaged tissues.
Resumo:
Objective: The study we assessed how often patients who are manifesting a myocardial infarction (MI) would not be considered candidates for intensive lipid-lowering therapy based on the current guidelines. Methods: In 355 consecutive patients manifesting ST elevation MI (STEMI), admission plasma C-reactive protein (CRP) was measured and Framingham risk score (FRS), PROCAM risk score, Reynolds risk score, ASSIGN risk score, QRISK, and SCORE algorithms were applied. Cardiac computed tomography and carotid ultrasound were performed to assess the coronary artery calcium score (CAC), carotid intima-media thickness (cIMT) and the presence of carotid plaques. Results: Less than 50% of STEMI patients would be identified as having high risk before the event by any of these algorithms. With the exception of FRS (9%), all other algorithms would assign low risk to about half of the enrolled patients. Plasma CRP was <1.0 mg/L in 70% and >2 mg/L in 14% of the patients. The average cIMT was 0.8 +/- 0.2 mm and only in 24% of patients was >= 1.0 mm. Carotid plaques were found in 74% of patients. CAC > 100 was found in 66% of patients. Adding CAC >100 plus the presence of carotid plaque, a high-risk condition would be identified in 100% of the patients using any of the above mentioned algorithms. Conclusion: More than half of patients manifesting STEMI would not be considered as candidates for intensive preventive therapy by the current clinical algorithms. The addition of anatomical parameters such as CAC and the presence of carotid plaques can substantially reduce the CVD risk underestimation. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Pattern recognition methods have been successfully applied in several functional neuroimaging studies. These methods can be used to infer cognitive states, so-called brain decoding. Using such approaches, it is possible to predict the mental state of a subject or a stimulus class by analyzing the spatial distribution of neural responses. In addition it is possible to identify the regions of the brain containing the information that underlies the classification. The Support Vector Machine (SVM) is one of the most popular methods used to carry out this type of analysis. The aim of the current study is the evaluation of SVM and Maximum uncertainty Linear Discrimination Analysis (MLDA) in extracting the voxels containing discriminative information for the prediction of mental states. The comparison has been carried out using fMRI data from 41 healthy control subjects who participated in two experiments, one involving visual-auditory stimulation and the other based on bimanual fingertapping sequences. The results suggest that MLDA uses significantly more voxels containing discriminative information (related to different experimental conditions) to classify the data. On the other hand, SVM is more parsimonious and uses less voxels to achieve similar classification accuracies. In conclusion, MLDA is mostly focused on extracting all discriminative information available, while SVM extracts the information which is sufficient for classification. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
INTRODUCTION The management of nonpalpable testicular masses is a challenging task, and coexisting infertility can further complicate the treatment decisions. We present our technique for microsurgical organ-sparing resection of incidental nonpalpable testicular nodules combined with microdissection for testicular sperm extraction and tissue cryopreservation in azoospermic patients. TECHNICAL CONSIDERATIONS Five infertile patients with azoospermia presented with nonpalpable hypoechoic testicular masses that were detected by Ultrasonography and underwent organ-sparing surgery. The testis was delivered through an inguinal incision, and the blood circulation was interrupted with a vascular clamp placed on the spermatic cord. Sludged ice was used to prevent warm ischemia, and a temperature probe was used to control the temperature at 12 degrees-15 degrees C. Real-time reflex ultrasonography was used to locate the tumor, and a stereotaxic hook-shaped needle was inserted under ultrasound guidance. The needle was placed adjacent to the tumor to guide the microsurgical resection. The tunica albuginea was incised over the tumor, which was dissected and removed, along with the adjoining parenchymal tissue. Frozen section studies were performed and, if malignancy was confirmed, biopsies of the tumor cavity margins and remaining parenchyma were obtained to ensure the absence of residual tumor. Microdissection was performed for excision of selected enlarged tubules that were processed and cryopreserved. CONCLUSIONS We present a technique for microsurgical organ-sparing resection of testicular tumor and sperm extraction that can be used in selected infertile patients with azoospermia in whom incidental masses have been diagnosed by ultrasonography. This conservative approach should be especially considered for patients with a solitary testis or bilateral tumors. UROLOGY 73: 887-892, 2009. (C) 2009 Elsevier Inc.
Resumo:
Morbid obesity is highly prevalent in the Western World, and its consequences present a real public health challenge. Voice alterations can represent one of these consequences and represent an opportunity for interference with therapeutic methods. This particularly features of the individual`s voice was the goal of the present study. A group of 45 adult volunteers of both sexes with a BMI greater than 35 Kg/m(2) was selected among patients of the Obesity Ambulatory of the Digestive Surgery Division. The control group consisted of volunteers matched by sex, age (+/- 1 year), and smoking habits, but with a BMI bellow 30 Kg/m(2). All subjects were submitted to laryngoscopic examination, audio perceptive analysis, and voice acoustics determination. Examinations were always performed by the same doctor, and diagnoses were provided by two different physician specialists in laryngology and voice. Obese individuals exhibit the following modifications in voice feature: hoarseness, murmuring, vocal instability, altered jitter and shimmer, and reduced maximum phonation times as well the presence of voice strangulation at the end of emission. The voices of individuals with morbid obesity are different of the voice of nonobese people and demonstrate significant changes in vocal characteristics.
Resumo:
The concept of parameter-space size adjustment is pn,posed in order to enable successful application of genetic algorithms to continuous optimization problems. Performance of genetic algorithms with six different combinations of selection and reproduction mechanisms, with and without parameter-space size adjustment, were severely tested on eleven multiminima test functions. An algorithm with the best performance was employed for the determination of the model parameters of the optical constants of Pt, Ni and Cr.
Resumo:
Aims: Claudins, a large family of essential tight junction (TJ) proteins, are abnormally regulated in human carcinomas, especially claudin-7. The aim of this study was to investigate claudin-7 expression and alterations in oral squamous cell carcinoma (OSCC). Methods and results: Expression of claudin-7 was analysed in 132 cases of OSCC organized in a tissue microarray. Claudin-7 mRNA transcript was evaluated using real-time polymerase chain reaction and the methylation status of the promoter was also assessed. Claudin-7 was negative in 58.3% of the cases. Loss of claudin-7 protein expression was associated with recurrence (P = 0.019), tumour size (P = 0.014), clinical stage of OSCC (P = 0.055) and disease-free survival (P = 0.015). Down-regulation of the claudin-7 mRNA transcripts was observed in 78% of the cases, in accordance with immunoexpression. Analysis of the methylation status of the promoter region of claudin-7 revealed that treatment of O28 cells (that did not express claudin-7 mRNA transcripts) with 5-Aza-2`-Deoxycytidine (5-Aza-dC) led to the re-expression of claudin-7 mRNA transcript. Conclusion: Loss of claudin-7 expression is associated with important subcellular processes in OSCC with impact on clinical parameters.