861 resultados para Fault Indicators
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The neutral wire in most existing power flow and fault analysis software is usually merged into phase wires using Kron's reduction method. In some applications, such as fault analysis, fault location, power quality studies, safety analysis, loss analysis etc., knowledge of the neutral wire and ground currents and voltages could be of particular interest. A general short-circuit analysis algorithm for three-phase four-wire distribution networks, based on the hybrid compensation method, is presented. In this novel use of the technique, the neutral wire and assumed ground conductor are explicitly represented. A generalised fault analysis method is applied to the distribution network for conditions with and without embedded generation. Results obtained from several case studies on medium- and low-voltage test networks with unbalanced loads, for isolated and multi-grounded neutral scenarios, are presented and discussed. Simulation results show the effects of neutrals and system grounding on the operation of the distribution feeders.
Resumo:
In this article some considerations obtained during the utilization of rotor response analysis techniques in hydraulic powerplants are discussed. An applied research work was carried out in two hydraulic turbines analysing the rotor response both theoretically and experimentally. A developed mathematical model was used to simulate the rotordynamic behaviour of Francis and Kaplan turbines. The main dynamical effects that appear during the operation of the machines are discussed too. A series of measurements were carried out in the turbines using impact hammers to determine the modal behaviour of the units. The tests were carried out with the machine still and in operation. Some results and the comparison with the theory is presented in this article. The improved theoretical model was used for a sensitivity analysis of the different bearings to the main excitations that fake place during the machine operation. From this analysis, the best measuring points for condition monitoring were determined.
Resumo:
Background: Detection of systemic inflammation, which is important for proper diagnosis and prompt treatment, can be challenging.Hypothesis: Measurement of plasma iron concentration is a sensitive method for detecting systemic inflammation in horses compared with measurements of plasma Fibrinogen concentration, a traditional marker for inflammation in the horse.Animals: Ninety-seven horses hospitalized with diseases causing systemic inflammation, 22 horses with localized inflammation, and 12 clinically normal horses were included in this study.Methods: A retrospective study was made on hospitalized horses that had both plasma iron and fibrinogen concentrations measured on hospital admission.Results: Plasma iron concentration was lower in horses with systemic inflammation (64 +/- 45 mu g/dL) than the reference interval minimum (105 mu g/dL) and were significantly lower (P = .001) than the value in a group of horses with local inflammation (123 +/- 45 mu g/dL) and in healthy transported horses (143 +/- 29 mu g/dL). Low plasma iron and high fibrinogen concentrations were both sensitive indicators of systemic inflammation in horses with sensitivity of 90 and 82%, respectively. There was a similar correlation between either continued decreases in iron concentration (R-sp of 0.239) or increases in fibrinogen concentration (R-sp of 0.280) during hospitalization and a worse prognosis.Conclusions and Clinical Importance: Measurement of plasma iron concentration better reflected acute inflammation than did fibrinogen concentration.
Resumo:
An apatite fission track study of crystalline rocks underlying sedimentary basins in northeastern Brazil indicate that crustal blocks that occur on opposite sides of a geological fault experienced different thermal histories. Samples collected on the West block yielded corrected fission-track ages from 140 to 375 Ma, whereas samples collected on the East block yielded ages between 90 and 125 Ma. The thermal models suggest that each block experienced two cooling events separated by a heating event at different times. We concluded that the West block moved downward relative to the East block ca. 140 Ma ago, when sediments eroded from the East side were deposited on the West side. This process represents the early stage of sedimentary basin formation and the opening of the South Atlantic Ocean in the region. Downward and upward movements related to heating and cooling events of these crustal blocks at different periods until recent times are proposed. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
The Precambrian crystalline basement of southeast Brazil is affected by many Phanerozoic reactivations of shear zones that developed during the end of the Neoproterozoic in the Brasiliano orogeny. These reactivations with specific tectonic events, a multidisciplinary study was done, involving geology, paleostress, and structural analysis of faults, associated with apatite fission track methods along the northeastern border of the Parana basin in southeast Brazil.The results show that the study area consists of three main tectonic domains, which record different episodes of uplift and reactivation of faults. These faults were brittle in character and resulted in multiple generations of fault products as pseudotachylytes and ultracataclasites, foliated cataclasites and fault gouges.Based on geological evidence and fission track data, an uplift of basement rocks and related tectonic subsidence with consequent deposition in the Parana basin were modeled.The reactivations of the basement record successive uplift events during the Phanerozoic dated via corrected fission track ages, at 387 +/- 50 Ma (Ordovician); 193 +/- 19 Ma (Triassic); 142 +/- 18 Ma (Jurassic), 126 +/- 11 Ma (Early Cretaceous); 89 +/- 10 Ma (Late Cretaceous) and 69 +/- 10 Ma (Late Cretaceous). These results indicate differential uplift of tectonic domains of basement units, probably related to Parana basin subsidence. Six major sedimentary units (supersequences) that have been deposited with their bounding unconformities, seem to have a close relationship with the orogenic events during the evolution of southwestern Gondwana. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
A single-phase superconducting fault current limiter (SFCL) using a 0.9 m length of YBCO coated conductor (CC) tape was tested in 220 V-60 Hz line for fault current up to 1 kA, operating in 77 K. In this work are presented the IN experimental curves measured under DC and AC currents for the electrical characterization of the CC tape in order to design a low voltage current limiter. The experimental setup is described and the test results are presented for a unit conducting a steady nominal AC current of 50 A and also during the fault time (I to 5 cycles.) the performance of the CC-based SFCL providing the limiting resistance developed in the whole tape length after few milliseconds of the beginning of the fault was analyzed.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A bifilar Bi-2212 bulk coil with parallel shunt resistor was tested under fault current condition using a 3 MVA single-phase transformer in a 220 V-60 Hz line achieving fault current peak of 8 kA. The fault current tests are performed from steady state peak current of 200 A by applying controlled short circuits up to 8 kA varying the time period from one to six cycles. The test results show the function of the shunt resistor providing homogeneous quench behavior of the HTS coil besides its intrinsic stabilizing role. The limiting current ratio achieves a factor 4.2 during 5 cycles without any degradation.
Resumo:
A new genus and species of cricket, Anomaloterga mantiqueirae, here described, is the first representative of Strogulomorphini to be reported from Brazil. The specimens were collected at night from the lower portions of live tree trunks in a summit forest located on the Mantiqueira Fault Escarpment, State of São Paulo.
Resumo:
In this article, an implementation of structural health monitoring process automation based on vibration measurements is proposed. The work presents an alternative approach which intent is to exploit the capability of model updating techniques associated to neural networks to be used in a process of automation of fault detection. The updating procedure supplies a reliable model which permits to simulate any damage condition in order to establish direct correlation between faults and deviation in the response of the model. The ability of the neural networks to recognize, at known signature, changes in the actual data of a model in real time are explored to investigate changes of the actual operation conditions of the system. The learning of the network is performed using a compressed spectrum signal created for each specific type of fault. Different fault conditions for a frame structure are evaluated using simulated data as well as measured experimental data.
Resumo:
Phasor Measurement Units (PMUs) optimized allocation allows control, monitoring and accurate operation of electric power distribution systems, improving reliability and service quality. Good quality and considerable results are obtained for transmission systems using fault location techniques based on voltage measurements. Based on these techniques and performing PMUs optimized allocation it is possible to develop an electric power distribution system fault locator, which provides accurate results. The PMUs allocation problem presents combinatorial features related to devices number that can be allocated, and also probably places for allocation. Tabu search algorithm is the proposed technique to carry out PMUs allocation. This technique applied in a 141 buses real-life distribution urban feeder improved significantly the fault location results. © 2004 IEEE.
Resumo:
Background. Iron-deficiency anemia currently is the most frequently occurring nutritional disorder worldwide. Previous Brazilian studies have demonstrated that drinking water fortified with iron and ascorbic acid is an adequate vehicle for improving the iron supply for children frequenting day-care centers. Objective. The objective of this study was to clarify the role of ascorbic acid as a vehicle for improving iron intake in children in day-care centers in Brazil. Methods. A six-month study was conducted on 150 children frequenting six day-care centers divided into two groups of three day-care centers by drawing lots: the iron-C group (3 day-care centers, n = 74), which used water fortified with 10 mg elemental iron and 100 mg ascorbic acid per liter, and the comparison group (3 day-care centers, n = 76), which used water containing only 100 mg ascorbic acid per liter. Anthropometric measurements and determinations of capillary hemoglobin were performed at the beginning of the study and after six months of intervention. The food offered at the day-care centers was also analyzed. Results. The fo od offered at the day-care center was found to be deficient in ascorbic acid, poor in heme iron, and adequate in non-heme iron. Supplementation with fortified drinking water resulted in a decrease in the prevalence of anemia and an increase in mean hemoglobin levels associated with height gain in both groups. Conclusions. Fortification of drinking water with iron has previously demonstrated effectiveness in increasing iron supplies. This simple strategy was confirmed in the present study. The present study also demonstrated that for populations receiving an abundant supply of non-heme iron, it is possible to control anemia in a simple, safe, and inexpensive manner by adding ascorbic acid to drinking water. © 2005, The United Nations University.